Professional Documents
Culture Documents
Tautwire MK 15B
Tautwire MK 15B
Tautwire MK 15B
Installation Manual
Bandak Light Weight Taut Wire
Mk 15B
Kongsberg Part no.: 702788
This document describes the installation of the Light
Weight Taut Wire Mk 15B supplied by Bandak.
The Mk 15B version has an electronic cabinet that is
located indoors, separate from the main unit of the Light
Weight Taut Wire.
178539/D
Document revisions
Rev.
A
B
C
D
Written by
Date
Sign.
23.09.04
SL
30.09.05
SL
07.02.07
HHO
08.06.07
PLB
Checked by
Date
Sign.
25.09.04
HT
06.10.05
HT
08.02.07
TH
08.06.07
TH
Approved by
Date
Sign.
25.09.04
SL
12.10.05
SL
08.02.07
TF
08.06.07
TH
The original signatures are recorded on the companys logistic data system.
Document history
Rev. A
Rev. B
Rev. C
Rev D
Initial Issue.
New type of Remote Control (RC).
Air connection type added in sections 2 and 3.5.4.
Note added to Electrical specifications in section 2, new drawing 4-0893 Rev. B
added and drawing 3-7728 updated to Rev..B.
178539/D
Installation Manual
Table of contents
1
INTRODUCTION....................................................................................................5
SPECIFICATIONS..................................................................................................6
INSTALLATION ...................................................................................................10
3.1
General information.........................................................................................10
3.2
Location of the units ........................................................................................10
3.2.1
3.2.2
3.4.2
3.5.2
3.5.3
3.5.3.1
General ........................................................................................................13
3.6.1.1
PG-glands ........................................................................................... 13
3.6.1.2
Tension relief...................................................................................... 13
3.6.1.3
3.6.1.4
3.6.1.5
Cable terminations.............................................................................. 15
3.6.2
3.6.2.1
3.6.2.2
3.6.2.3
3.6.3
3.6.4
3.6.4.1
178539/D
INSTALLATION DRAWINGS............................................................................17
178539/D
Installation Manual
1 INTRODUCTION
The Light Weight Taut Wire Mk 15B is a position reference
system designed for use in a deck-mounted port or starboard
position on surface vessels. The purpose of the Light Weight
Taut Wire system is to provide accurate data of the vessel's
movements, relative to a known point, in the fore/aft (alongship) and port/starboard (athwart-ships) directions.
WARNING
Caution
Note
178539/D
2 SPECIFICATIONS
Mechanical specifications
Light Weight Taut Wire Mk 15B:
Height: .....................3550 mm (Parked), 1665 mm (Operational)
Width: ............................................................................ 1400 mm
Depth (Length): .......1700 mm (Parked), 5115 mm (Operational)
Weight (excluding Depressor weight): .............................2200 kg
Electrical Cabinet:
Height: ........................................................................... 1900 mm
Width: .............................................................................. 800 mm
Depth: .............................................................................. 510 mm
Weight.................................................................................250 kg
Depressor:
Volume: ............................................................................. 50 dm3
Weight: ...............................................................................360 kg
Depressor (optional):
Volume: ............................................................................. 65 dm3
Weight: ...............................................................................460 kg
Drop-in Remote Control Unit (optional):
Height: ............................................................................. 102 mm
Width: .............................................................................. 202 mm
Depth (exclusive cable gland): .......................................... 50 mm
Weight: ...................................................................................2 kg
Electrical specifications
Input voltage:
440 VAC, +20%, -27%, 3-phase, 50 to 60 Hz (50 A fuses)
Note
178539/D
Installation Manual
Power consumption:
440 VAC: 18 kW / 37 A continuous load
220 VAC: 500 W
Batteries: ......................................PLC; lithium size AA, 3.6 V
Cable specifications
See Table 1 on page 14.
Air specifications
Pressure:............................. 10 bar (maximum), 6 bar (minimum)
Flow: ............................................................. 5 Nm3/h (minimum)
Purity: ..................................................... according to ISO8573-1
Solid contamination:....................................................class 5
Maximum particle size..................................... 40 m
Maximum concentration ............................. 10 mg/m3
Water: ..........................................................................class 3
Dew point......................................................... -20 C
Oil: ...............................................................................class 5
Maximum concentration:............................ 25 mg/m3
Connection:...............................................................GE12LR 3/8"
178539/D
Environmental specification
Light Weight Taut Wire Mk 15B:
Enclosure material: ....................Surface treated and painted steel
Enclosure protection (located on open deck): ....................... IP56
Operational temperature range: ................-15 to +65 C, no icing
Operational humidity:........... 20 to 100 % RH with condensation
Operational Wind Strength .......................................0 to 80 knots
Storage temperature range: ......................................-25 to +70 C
Storage humidity: .............0 to 100 % RH, sealed aluminium foil
Electrical Cabinet:
Mounting plates: ..........................................................Zinc plated
Enclosure protection (indoor location): ................................. IP22
Operational temperature range (indoor location): ...... 0 to +55 C
Operational humidity:........... 20 to 93% RH (none condensation)
Storage temperature range: ......................................... 0 to +65 C
Storage Humidity:................. 20 to 80% RH (none condensation)
178539/D
Installation Manual
178539/D
3 INSTALLATION
This chapter presents the procedures for installation of the Light
Weight Taut Wire Mk 15B supplied by Bandak AS.
Note
Ensure that the electrical cabinet has sufficient space both for
mounting and for service area, see Figure 5.
10
178539/D
Installation Manual
3.3 Logistics
Safety:
Personnel qualifications:
Three.
Ship location:
No recommendations.
None.
3.4 Handling
WARNING
178539/D
11
The frame shall be mounted in such a way that the Light Weight
Taut Wire Unit be standing horizontally levelled and 90 on the
along-ship axis.
12
178539/D
Installation Manual
Note
PG-glands for cable number 7 and 8 which are going into the
junction box of the Servo Motor at the Light Wire Taut Wire
Unit.
178539/D
13
1
2
Proposed
PG-gland at
Electrical
Cabinet
Delivered by Bandak AS
N/A
2
PG-16
PG-16
PG-21
PG-21
PG-16
PG-21
PG-21
PG-16
10
PG-16
11
PG-21
12
13
PG-21
PG-16
14
Installation Manual
Caution
178539/D
15
16
178539/D
Installation Manual
4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:
Title
Figure 1
N/A
Figure 2
N/A
Figure 3
N/A
Figure 4
N/A
Figure 5
N/A
Figure 6
N/A
Figure 7
N/A
Figure 8
N/A
Figure 9
N/A
Figure 10
N/A
Figure 11
N/A
Figure 12
N/A
Figure 13
N/A
Figure 14
NA
4-0893
3-7543
3-7728
Options
Remote Control Unit, Outline Drawing
S-03205
NA
S-03660
NA
178539/D
17
Figure 1 Light Weight Taut Wire Mk 15B - Side View (Deployed Position)
Figure 2 Light Weight Taut Wire Mk 15B - Plan View (Deployed Position)
18
178539/D
Installation Manual
Figure 3 Light Weight Taut Wire Mk 15B - Side View (Stowed Position)
178539/D
19
Wire
Operational
Area
Vessel side
Plan view
Taut Wire
Gimbal Head
Vessel side
max.
23o
Inboard
angle
max.
23o
Outboard angle
(Limited by
the horizontal
distance of the
gimbal head
from the
vessel side) Wire
Operational Area
Depressor Weight
(Cd2596a)
Side view
Figure 4 Operational Area and Angles of the Wire
20
178539/D
Installation Manual
800
5
1
0
Cabinet
Service
Area
(CD2685)
1
3
1
0
All dimensions in mm
21
800 mm
31 mm
4 ea. 10 mm
(max.) holes
500
mm
39
mm
22
178539/D
Installation Manual
0 25
555
1675
1160
625
25
12 x 18.5
(CD2600)
25
3 x 18.3kN
3 x 5kN
3 x 10kN
3 x 23kN
(CD2619)
178539/D
23
Between arms,
around shaft
24
178539/D
Installation Manual
Cable Entrances.
Recommended
Cable Sequence
(top-down): 6, 4, 9,
5. Recommended
PG-gland (topdown): 21, 21, 16,
16.
Cable no.
13
178539/D
25
X42
Termination
Rack
X12
Termination
Rack
TSXSCA62
Junction Box
Cable no. 5
Cable no. 4
Cable no. 9
Terminal Rack
PG-
26
178539/D
Installation Manual
178539/D
27
Pos
Part List
Name
Qty
Item
Art.no.
Manufacturer
Power
EMB 9343-E
Lenze
Controller
EVS 9828-ES
Lenze
KM
Contactor
LC1D65P7
Telemecanique
F1
Element automatic
C60H/C50-3
Merlingerin
F6K6
Thermic relay
GV2 ME08+GVAN 20
Telemecanique
F7
Thermic relay
GV2 ME02+GVAN 20
Telemecanique
K6
Contactor
LC1D 12P7
Telemecanique
K7
Contactor
LC1D 09P7
Telemecanique
F12
Fuses automatic
GB2-CD12
Telemecanique
10
PLC Display
EMZ 9371 BB
Lenze
11
Earth
SZ 2364
Rital
12
49+24
Terminal point
M 4/6D2
Entralec
13
PSU3
Power
9522 24V
Mascot
Terminal box
TSX PA CC01
Telemecanique
14
15
X71
Card keeper
SKB 164/C64
16
K11
Contactor
CA2KN40M7+LA1KN11
Telemecanique
17
K10
Contactor
CA2KN40M7+LA1KN11
Telemecanique
18
K9
Contactor
CA2KN40M7+LA1KN11
Telemecanique
19
K8
Contactor
CA2KN40M7+LA1KN11
Telemecanique
20
KR
Relay module
ABR2E111M
Telemecanique
21
K102
Relay
RM111 12VDC
Entralec
22
K101
Relay
RM111 12VDC
Entralec
23
Z1
Drossel
ELN3 0075H045
Lenze
Battery
TSX PL P01
Telemecanique
24
25
06
PLC module
Analogue out 0-10 v
Telemecanique
26
05
PLC module
Analogue in 0-10 v
Telemecanique
27
01-02
16 in / 12 out
TSX DMZ 28 DR
Telemecanique
28
00
TSX 372110 Y
Telemecanique
28
178539/D
Installation Manual
178539/D
29
30
178539/D
LCD
Contrast
+5V DC
RS-422
RS-232