10.08
Grooved ends allow fast, easy installation with just
two Victaulic couplings or the valve may be mounted
to flanged (ANSI CL.150) equipment using either to
Victaulic Style 741 Vic-Flange or Style 744 FireLock
flange adapters on either end.
Series 717
(2 3"/65 80 mm)
Series 717
(4 12"/100 300 mm)
Series 717H
High Pressure Check Valve
(2 3"/50 80 mm)
Approvals/Listings:
Job/Owner
Engineer
System No.
Spec Section
Location
Paragraph
Contractor
Approved
Submitted By
Date
Date
Housing:
Shaft Plug:
Body Coating:
Pipe Plug:
Body Seat:
Series 717H Nitrile O-ring installed into an electroless
nickel plated endface
Series 717 (2 3"): PPS Coated ductile iron
Series 717 (4 12"): Electroless Nickel plated
Disc Seal or Coating: (specify choice1)
Grade T nitrile (Series 717H Only)
Nitrile (Orange color code). Temperature range 20F to
+180F/29C to +82C. Recommended for petroleum
products, air with oil vapors, vegetable and mineral oils
within the specified temperature range; except hot, dry air
over +140F/+60C and water over +150F/+66C.
NOT RECOMMENDED FOR HOT WATER SERVICES.
Discs:
Series 717H (2 3"/50 80 mm): CF8M Cast
Stainless Steel
Series 717 (2 3"): Aluminum bronze with
elastomer seal
Series 717 (4 12"/100 300 mm): Elastomer
encapsulated disc with electroless nickel plated seat
Shaft:
Series 717H (2 3"/50 -80 mm): Brass
Series 717 (2 3"): Type 416 Stainless Steel
Series 717 (4 12"/100 300 mm) Type 316
Stainless Steel
victaulic.com
cULus
FM
LPCB
Vds
2"/50mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
2"/65mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
76.1mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
3"/80mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365psi/2517kPa
4"/100mm
n/a
n/a
n/a
n/a
5"/125mm
n/a
n/a
n/a
n/a
139.7mm
n/a
n/a
n/a
n/a
6"/150mm
n/a
n/a
n/a
n/a
165.1mm
n/a
n/a
n/a
n/a
8"/200mm
n/a
n/a
n/a
n/a
10"/250mm
n/a
n/a
n/a
n/a
12"/300mm
n/a
n/a
n/a
n/a
cULus
FM
LPCB
Vds
2"/50mm
n/a
n/a
n/a
n/a
2"/65mm
up to 250psi/1725kPa
n/a
up to 365 psi/2517kPa
n/a
76.1mm
up to 250psi/1725kPa
n/a
up to 365 psi/2517kPa
up to 16bar/232psi
3"/80mm
up to 250psi/1725kPa
n/a
up to 365 psi/2517kPa
up to 16bar/232psi
4"/100mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365 psi/2517kPa
up to 16bar/232psi
5"/125mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365 psi/2517kPa
n/a
139.7mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365 psi/2517kPa
up to 16bar/232psi
6"/150mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365 psi/2517kPa
up to 16bar/232psi
165.1mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 365 psi/2517kPa
n/a
8"/200mm
up to 365psi/2517kPa
up to 365psi/2517kPa
up to 348 psi/2400kPa
up to 16bar/232psi
10"/250mm
up to 250psi/1725kPa
up to 250psi/1725kPa
up to 1725kPa/250psi
n/a
12"/300mm
up to 250psi/1725kPa
up to 250psi/1725kPa
up to 1725kPa/250psi
n/a
victaulic.com
D E
A
1
2
3
inches
mm
21/2
65
76.1mm
3
80
4
100
5
125
139.7mm
6
150
165.1mm
8
200
10
250
12
300
K
B
Typical 2 3"/65 80 mm
Nominal
Size
K
J
B
" NPT Upstream Drain
" NPT Downstream Drain
2" NPT (Drain Optional)
D E
2
Actual
Outside
Diameter
E to E
A
inches
mm
2.875
73.0
3.000
76.1
3.500
88.9
4.500
114.3
5.563
141.3
5.500
139.7
6.625
168.3
6.500
165.1
8.625
219.1
10.750
273.0
12.750
323.9
inches
mm
3.88
99
3.88
99
4.25
108
9.63
245
10.50
267
10.50
267
11.50
292
11.50
292
14.00
356
17.00
432
19.50
495
inches
mm
4.26
108
4.26
108
5.06
129
6.00
152
6.80
173
6.80
173
8.00
203
8.00
203
9.88
251
12.00
305
14.00
356
inches
mm
3.57
91
3.57
91
4.17
106
3.88
99
4.50
114
4.50
114
5.00
127
5.00
127
6.06
154
7.09
180
8.06
205
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
2.75
70
3.50
89
4.17
106
4.17
106
4.50
114
4.50
114
5.65
144
6.69
170
7.64
194
2.00
51
2.15
55
2.15
55
2.38
61
2.38
61
2.15
55
2.15
55
2.51
64
4.50
114
5.88
149
5.88
149
6.67
169
6.67
169
8.85
225
10.92
277
12.81
925
3.50
89
4.08
104
4.08
104
4.73
120
4.73
120
5.65
144
6.73
171
7.73
196
3.35
85
3.98
101
3.98
101
3.89
99
3.89
99
5.75
146
5.05
128
5.96
151
6.91
176
Approx.
Weight
Each
lbs.
kg
3.6
1.6
3.6
1.6
4.5
2.0
20.0
9.1
27.0
12.3
27.0
12.3
38.0
17.2
38.0
17.2
64.0
29.0
100.0
45.4
140.0
63.5
B
C
D
E to E
A
Approx.
Weight
Each
inches
mm
2
50
21/2
65
inches
mm
8.66
219.8
9.37
238.0
inches
mm
6.46
164.1
6.94
176.3
inches
mm
3.23
82.1
3.31
84.1
inches
mm
1.48
37.5
1.66
42.2
inches
mm
3.02
76.7
3.40
86.4
inches
mm
2.80
71.0
3.38
85.9
inches
mm
inches
mm
inches
mm
4.25
108.0
4.38
111.3
lbs.
kg
10.7
4.9
13.8
6.3
9.37
238.0
9.62
244.3
6.94
176.3
7.44
189.0
3.31
84.1
3.53
89.7
1.66
42.2
1.91
48.5
3.40
86.4
3.65
92.7
3.38
85.9
3.38
85.9
4.38
111.3
4.63
117.6
13.8
6.3
20.0
9.1
76.1mm
3
80
victaulic.com
The charts below express the flow of water at 60F/16C through valve.
S717H / 717HR
S717H / 717HR
10
PRESSURE
LOSS - P.S.I.
Pressure Loss (psi)
10
11
2
0.1
0.1
10
10
"&
50
m
"&
2
m
76
"&
80
1000
1000
100
100
Flow (GPM)
FLOW
RATE
- G.P.M.
2"
3"
2.5"
S717H / 717HR
S717H / 717HR
1.00
1.00
100
100
m
80
76
m
50
&
"&
2
"&
10.00
10.00
3"
100.00
100.00
1000
1000
FLOW2"RATE 2.5"
(Litres/Min)
3"
victaulic.com
10000
10000
The charts below express the flow of water at 60F/16C through valve.
S717 / 717R
S717 / 717R
0.1
0.1
10
10
4"
&2
00
mm
10
"&
2
50
12
mm
"&
30
0m
m
8"
&
13
9m
m"
16
5m
m"
100
100
6"
5"
&
mm
4"
&
80
10
0m
m
m
76m
11
3"
&
2
"&
10
10
1000
1000
10000
10000
Flow (GPM)
5"
6"
8"
10"
12"
100000
100000
2-1/2"
3"
S717 / 717R
S717 / 717R
100.00
1.00
1.00
10
10.00
8"
10"
30
&
10000
10000
5"
0m
5"
&1
39m
6"
m
&1
65
mm
8" &
20 0
mm
10"
&2
5 0m
12
m
"
m
0m
4"
&
&8
10
0
76m
1000
1000
100
100
4"
3"
2
"&
10.00
10.00
mm
100.00
12"
2.5"
100000
100000
3"
Installation
Reference should always be made to the I-100 Victaulic Field Installation Handbook for
the product you are installing. Handbooks are included with each shipment of Victaulic
products for complete installation and assembly data, and are available in PDF format
on our website at www.victaulic.com.
Note
This product shall be manufactured by Victaulic or to Victaulic specifications. All products
to be installed in accordance with current Victaulic installation/assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard
equipment without notice and without incurring obligations.
Warranty
Refer to the Warranty section of the current Price List or contact Victaulic for details.
Trademarks
Victaulic and FireLock are registered trademarks of Victaulic Company.