One Shape

One single file in continuous rotation

Your Endo Specialist

Ne

One Shape P. 4

One Shape Apical P. 12

Advertising + Protocol for use

Advertising + Protocol for use

0459

0459

Year of CE-marking: 2012


Medical device class IIA according
to directive 93/42/EEC
Certifying body: LNE/G-MED
Medical device for dental care,
meant for professional dental
use only.
See product labelling and, where
applicable, instructions for use.
Sterility guaranteed unless package
open or damaged.
Maximum number of uses
indicated on the product labeling.

Year of CE-marking: 2014


Medical device class IIA according
to directive 93/42/EEC
Certifying body: LNE/G-MED
Medical device for dental care,
meant for professional dental
use only.
See product labelling and, where
applicable, instructions for use.
Sterility guaranteed unless package
open or damaged.
Maximum number of uses
indicated on the product labeling.

Sterility guaranteed if package


is unopened and undamaged.

Sterility guaranteed if package


is unopened and undamaged.

One Shape GP Points &


One Shape Paper Points
P. 14

MMcontrol P. 16

Advertising

Year of CE-marking: 2014


Medical device class IIA according
to directive 93/42/EEC
Certifying body: LNE/G-MED
Medical device for dental care,
meant for professional dental
use only.
See product labelling and, where
applicable, instructions for use.

0459

Year of CE-marking: 2013


Medical device class IIA according
to directive 93/42/EEC
Certifying body: LNE/G-MED
Medical device for dental care,
meant for professional dental
use only.
See product labelling and, where
applicable, instructions for use.

Advertising
0459

Supporting you
MICRO-MEGA, whose history dates back to 1905, has always been at the
forefront of technology and holds internationally recognized know-how in the design,
manufacture and marketing of medical devices for use by Dental Specialists around
the world (root canal instruments, obturation, handpieces and instrument hygiene).
Through our technical expertise, our capacity for innovation and our commitment to
quality we continue to offer solutions based on high-tech medical products.

4 Quality
q

Discover
MICRO-MEGA
solutions,
developed for you
and with you

Our main aim is to


satisfy our customers
by offering them
products and services
that always meet
their expectations.
All our savoir-faire
for your comfort and
that of your patients!

The single file in continuous rotation


with more benefits
Simplifying your endodontic procedures with complete safety
and effectiveness is our primary concern.
MICRO-MEGA now offers you the new One Shape, the one
and only NiTi instrument in continuous rotation for quality root
canal shaping.

19
m
20 m
mm
22
mm

MICRO-MEGA innovation: the instrument presents a variable


asymmetrical cross-section along the blade.

n 
Asymmetrical cross-section
MICRO-MEGA patent since 1999.
n 
Longer pitch.
n 
Variable cross-section along the instrument.
n 
Depth identifications on the file.

One Shape provides simplicity to practitioners:


n Simplicity of use: 1 single instrument for canal shaping.
n Productivity: sterile instrumentation saves time.
n Flexibility: superior ability to negotiate curves.
n Efficiency: in continuous rotation.
n Safety: single use.
n Innovation: new asymmetrical cross-section with longer pitch.

One Shape provides


simplicity
that practitioners
are looking for
in endodontics

Product benefits
4 Simplicity of use
q
n S implification of the instrumentation sequence: 1

single reference to manage stock.


n N o instrument change during canal shaping: only

1 sterile and single-use instrument.


n F acilitated instrument handling for assistants.

Literature
references
Comfortable results are shown also by
innovative single-use One Shape file. [...]
This means that the goal of simplifying the
technique and reducing the overall duration
of the treatment is respected. If the irrigating
protocol is correct, One Shape permits
a quick treatment with the same efficacy
in bacterial reduction as conventional
Ni-Ti instruments.
Antibacterial efficiency of conventional
and single-use Ni-Ti endodontic instruments:
an in vitro microbiological evaluation.
Alberto DAGNA, Carla Renata Arciola, Livia
Visai, Laura Selan, Marco Colombo, Stefano
Bianchi, Claudio Poggio / The International
journal of artificial organs 10/2012

Literature
references

4 Efficiency
q

The use of One Shape decreased the preparation


time by up to () 59% compared with Mtwo. The
use of the other single-file system F360 decreased
the preparation time by about 30%. These results
are in agreement with a previous report, in as far as
the use of Reciproc decreased the preparation time
by 60% compared with Mtwo (Brklein et al. 2012).
The fact that preparation time was decreased
by about 6230% when using the single-file
systems is a clinically relevant finding in as far as,
simultaneously, the time available for irrigation
and chemical debridement of the root canal system
is also markedly reduced. To compensate the
decreased irrigation time when using single-file
systems, larger volumes of irrigant and additionally
activation of the irrigants seem to be advisable
to improve chemical dissolution of residual debris
and disinfection of the root canal system (Brklein
et al. 2012).
Shaping ability of different single-file systems in
severely curved root canals of extracted teeth.
Brklein S, Benten S, Schfer E. / International
Endondontic Journal June 2013

n T ime saving: sterile instrument, ready for use.


n Economic: no prior sterilization before use.
n Rapid treatment: a root canal treatment is approximately 60%

faster than a conventional treatment.


n Asymmetrical cross-section + longer pitch increase the available

volume for upward debris elimination: high-quality shaping.


n Overall duration of treatment shortened, leaving more time for

irrigation*.

* It is imperative to let the irrigant act for at least 15 minutes for optimal root canal disinfection.

and even more!


4 Security
q
n C ontrols risk of infection due to sterile

blister packaging: safety for patients and


staff.
n R espect of office hygiene.
n T he variable pitch reduces the screwing

effect.
n T he quantity of apically extruded debris is

less with continuous rotation.


n M inimal fatigue along the length of the file

virtually eliminates the risk of separation.


n S ingle use: It is recommended to use the

One Shape instrument for the treatment


of only one tooth*.

* Dispose of all instruments that show a sign of unwinding, wear or


premature fatigue after the treatment of one or two root canals.

Literature
references
The behavior of instruments is linked to their geometry and their design.
Producing an asymmetric instrument modify the file behavior. In the present
study, the axial stresses decreased, but the torque did not change with
an asymmetric triple helix cross-section. These results may encourage
manufacturers to propose asymmetric instruments to increase safety.
Effect of Asymmetry on the Behavior of Prototype Rotary Triple Helix Root
Canal Instruments.
Franck Diemer, DDS, MS, PhD, Jrome Michetti, DDS, MS, Jean-philippe
Mallet, DDS, MS, and Robert Piquet, PhD / JOE Volume 39, Number 6,
June 2013
Rotary instrumentation was associated with less debris extrusion compared
to reciprocal instrumentation. () Reciproc produced significantly more debris
compared to all other systems.
Quantitative evaluation of apically extruded debris with different single-file
systems: Reciproc, F360 and OneShape versus Mtwo. Burklein, Shaefer
& Benten / IEJ 2013 July 6

4 Flexibility
q
n M ore flexibility due to the longer instrument

pitch.
n E rgonomics maximum comfort, safety

and efficiency.
n E asy progression superior ability to

negotiate curves.
n I mproved working comfort the longer

pitch makes an easier progression of the


instrument to the apex.

l tests

n
Based o

more

clinica
than 200

Operating Protocol
Access Cavity
Preparation

1
n


Take
a preoperative radiograph
to assess canal anatomy
and establish Estimated
Working Length (EWL).


Establish
straight-line access
preparation to expose canal
orifices.


Remove
coronal constrictions
with ENDOFLARE (or use
your current flaring technique).
Canal
penetration
of
ENDOFLARE is limited to
3 mm below the pulp
chamber floor.

Establishing the Glide Path


Scout each root canal with small diameter hand files which provide information about the
root canal anatomy complementary to that obtained by the preoperative X-rays.
Prepare the glide path using #10 Stainless Steel K-type hand file (for example MMC 10).

K-File
- If the #10 K file easily
reaches the EWL and if it
is possible to take a #15
K file down to this EWL:
Copiously irrigate the canal
and use One Shape
according to the established
protocol.

K-File

(MMC)
N10

(MMC)
N15

NaOCl

NaOCl

EWL


Irrigate
thoroughly with
sodium hypochlorite.

EWL

Or
- If canal constrictions prevent the #10 K file from easily reaching the EWL, complete glide
path preparation using G-Files, NiTi files for glide path development in continuous rotation. Use
G1 to EWL followed by G2 to EWL according to the recommended protocol. Copiously irrigate
after each instrument passage. Use the #15 K file to determine Working Length (WL).

ENDOFLARE

K-File

G1

(MMC)
N10

3 mm

NaOCl
EWL

10

10

G2

NaOCl

NaOCl
EWL

NaOCl
EWL

Shaping the Root Canal

Irrigate thoroughly with sodium hypochlorite.


A
 chelating gel (MM-EDTA Cream) can also be used during the root canal shaping.
a) Place One Shape down to the 2/3 of the WL using an in and out movement without pressure.
Perform an upward circumferential filing movement in order to pre-enlarge the canal.
Withdraw the One Shape instrument from the root canal and clean it. Irrigate and check canal
patency with a #10 K file.
b) Reintroduce the One Shape instrument into the root canal and place it down to 3 mm from WL
using an in and out movement without pressure.
Withdraw the One Shape instrument from the canal and clean it. Irrigate and re-check the
canal patency with a #10 K file.

Note

It is highly
recommended,
at a minimum, to
use One Shape
on an extracted
tooth or to receive
training regarding
this product prior
to using it for root
canal treatment.

c) Reintroduce the One Shape instrument into the root canal and take it down to the WL by
performing the recommended in and out movement.
The WL can be reached in one or more passages (file withdrawal, cleaning of the file, irrigation
and patency check) depending on the complexity of the canal anatomy.
An upward circumferential filing movement can then be performed if necessary and according
to the root canal anatomy.
Remove and clean the instrument and irrigate the canal when apical resistance or a slight apical pull is encountered. Repeat steps
until the WL is reached.

One Shape

One Shape

One Shape

NaOCl

NaOCl

NaOCl

2/3 WL

WL-3 mm

Speed of rotation: 350-450 rpm

Maxi torque: 2.5 N.cm

WL

WL: Working Length

11

11

Optional

Apical finishing
MICRO-MEGA offers an optional solution with specific apical finishing files, One Shape
Apical. One Shape Apical files are sterile and single use instruments which can be used
after shaping with One Shape to apically enlarge the root canal.

instruments

One Shape Apical 1: N30 - .06

One Shape Apical 2: N37 - .06

12

12

n
n
n
n
n
n

19
20 mm
mm
22
mm

are proposed:

19
20 mm
mm
22
mm

 terile and single-use files.


S
Efficient enlargement of the apical zone after One Shape instrumentation.
Apical preparation shaping respecting the path.
Respect of the apical constriction.
Superior debris removal.
Minimal fatigue along the length of the file virtually eliminates the risk of separation.

Operating Protocol
One Shape
One Shape

One Shape Apical 1


One Shape Apical 1

One Shape Apical 2

NaOCl

NaOCl

WL

Rotation speed: 350-450 rpm


Maxi torque: 2.5 N.cm

NaOCl

WL

Rotation speed: 350-450 rpm

WL

Maxi torque: 1 N.cm

Working movement identical to One Shape technique: in and out movement without pressure in the apical zone.
n

One Shape Apical 1 for use after One Shape WL.

One Shape Apical 2 for use after One Shape Apical 1 WL.

In case of resistance or slight apical pull remove and clean the instrument and irrigate the root canal.
This instrument is for single use and intended for the treatment of only one tooth.
Check the condition of the instrument after the treatment of each canal and dispose of all instruments which show signs
of unwinding, wear or premature fatigue. In case of reutilization the instrument presents a risk of separation. The root canal
must be irrigated using sodium hypochlorite after each instrument passage.

13

13

Obturation
Whether it is temporary or permanent, obturation is an essential stage of every endodontic
treatment. MICRO-MEGA developed reliable and practical filling solutions for use after
root canal preparation is performed with One Shape.
MICRO-MEGA presents you the One Shape Oburation range, which is the ideal complement
of One Shape.

n O
 ne Shape Gutta Percha Points:
Shaping, Apical 1, Apical 2
n O ne Shape Paper Points:
Shaping, Apical 1, Apical 2

14

14

G ai n in
si m pl ic ity :
O ne fi le =
o ne p o in t!

One Shape Gutta Percha Points


n S pecific adapted tapers for obturation after using the One Shape file.
n T he One Shape GP Points are radiopaque. Highest precision for all filling
techniques: cold, warm or thermomechanical condensation techniques.
n F lexible for perfect adjustment to all root canal anatomies without bending.
One Shape Paper Points
n Q uick and efficient drying.
n E asy-to-identify sizes due to the same color code.
n S haped for easy and reliable placement to the apex.

15

15

MMcontrol
Zoom on your safety asset: motor with torque and speed control + integrated apex locator,
MMcontrol is an indispensable tool in order to achieve optimal safety in the daily practice
of endodontics.

n Proven reliability
n Simplicity of implementation
n Safe endodontic procedure

16

MMcontrol
+ One Shape
Solution Kit
Ref. 51400104

MMC

Apic

al

G-Fil

es

n
n

n
n
n

END

OFL

ARE

1 MMcontrol
 blister MMC 08 (sterile - L25 mm)
1
+ 1 blister MMC 10 (sterile - L25 mm)
+ 1 blister MMC 15 (sterile - L25 mm)
1 blister ENDOFLARE (sterile - L25 mm)
1 blister G-Files G1 (sterile - L25 mm)
+ 1 blister G-Files G2 (sterile - L25 mm)
5 blisters One Shape (sterile - L25 mm)

n
n

1 blister One Shape Apical 1 (sterile L25 mm) + 1 blister One Shape Apical 2
(sterile - L25 mm)
1 box Gutta Percha One Shape ShapingL29 mm
1 box Paper Points One Shape ShapingL29 mm

17

Total solution

18

18

One Shape is
the complete solution
for endodontics!

Testimonials

Dr Tobias Mackert,
Germany

The innovative One Shape New Generation


files brings simplicity to the endodontic
procedure. The flexibility and the new
design of the files brings better cutting
efficiency, less screwing effect and higher
safety of instrument fractures. I also
appreciate to have the possibility to use
the new One Shape Apical files in cases
with lager apical foramina. All files respect
the original root canal anatomy really well
and the reduction of the shaping time gives
me more valuable time for irrigation.

The One Shape


Concept (including
the G Files) allows
me to simplify the
mechanical shaping
protocol for anatomical Dr. Liviu Steier,
Germany
non complicated root
canals. The addition
of the Apical Shaping
Files addresses exclusively the apical third
of the root canal and replaces earlier
practice of hybrid techniques.
I personally sense the application of
conventional (clockwise) kinematics with
the One Shape File Concept more gentle
and less fatiguing to the muscles
of the operators hand when compared
to reciprocation file systems.

They have tried it And they love it!

Dr. Alberto Dagna,


Italy

One Shape is really a smart, efficient


and helpful instrument. I love it, since
it was introduced in 2012. The One
Shape New Generation has lost
the sucking effect inside the root
canal and give a good feeling during
the treatment. It's able to negotiate
the root canal and its curvatures.
It reaches the apex easily and with
no resistance. It's useful for a lot
of cases and helpful for each dentist.
Single-file technique with single-use
instrument in continuous rotation

is a great help in simplifying daily


endodontics. All the endodontist
and the general practitioner should
be not yet scared by fracture of
the instrument: no sterilization and
stocking procedures are needed,
no stresses are accumulated. For
each treatment a new file is used
and discarded at the end of shaping.
In my personal opinion, I think that
One Shape introduced a new
"philosophy" of root canal treatment:
single, safe and simple use.

19

19

Clinical cases
Dr. Alberto DAGNA
University of Pavia - ITALY

Pre-operative x-ray

Access cavity

Orifices opening
with ENDOFLARE

Canal scouting with


MMC n15 and preflaring

20

Clinical cases realized by Dr. Alberto DAGNA

Root canal shaping


with One Shape and
control of apical diameter
with K File n25

One Shape Apical 1


in palatal root canal

Final rinse with NaOCI and


drying with One Shape
Paper Points (One Shape
Paper Points Shaping
and Apical 1)

21

Gutta Percha master cone


(One Shape GP Points
Shaping) and apical sealing
with continuous wave
technique of buccal root
canals

Gutta Percha master cone


(One Shape GP Points
Apical 1) and apical sealing
of patatal root canal
and backfilling

Post-operative x-ray

22

22

Bibliography
Rui Liu, Ben Xiang Hou, Paul R. Wesselink,
Min-Kai Wu, Hagay Shemesh
The Incidence of Root Microcracks
Caused by 3 Different Single-file
Systems versus the ProTaper System
JOE Volume 39, Number 8,
August 2013
Brklein S., Benten S., Schfer E.
Shaping ability of different single-file
systems in severely curved root canals
of extracted teeth
International Endondontic Journal
June 2013
Anil Dhingra, Punit Srivastava,
Dipti Chadda, Satyabrat Banerjee
Simplify your Endodontics with Single
File Systems - Case Reports
IOSR Journal of Dental and Medical
Sciences (IOSR-JDMS), Vol. 6, Issue 6
(May - Jun. 2013), PP 44-51
One Shape for Endodontic
Instrumentation
INSIDE DENTISTRY February 2013

Dr A. Gaudin, Prof Fabienne Perez


Comment rationaliser la mise
en forme canalaire ?
Dentoscope N120 - 04/11/2013

Dr. Alexandre Viteaux


Wurzelkanalaufbereitung mit nur
einem Instrument
Endo Tribune Swiss Edition - 06.11.2013

Dr Nicolas Guernier
Linstrumentation unique en rotation
continue
Dental Tribune - Octobre 2013

C. Gernhardt
One Shape, ein vollrotierendes
Einfeilensystem fr die effiziente
und sichere Wurzelkanalaufbereitung
Eine bersicht
ZWR - Oktober 2013

Dr Alexandre Viteaux
Linstrumentation unique en rotation
continue
Dental Tribune - Juin 2013
Dr Serge Bal
Du HERO 642 au One Shape
Clinic - Mars 2013

Dr. Jrome Elias, Dr. Jean-Jacques Bonnin


Sichere Wurzelkanalaufbereitung
mit nur einem Intrument
Dental Inside - Dezember 2012

Dr Jrome Elias, Dr Jean-Jacques Bonnin


One Shape MICRO-MEGA :
Scuriser la prparation canalaire
avec un instrument unique
Alpha Omega - Juin 2012

Alberto Dagna, Carla Renata Arciola,


Livia Visai, Laura Selan, Marco Colombo,
Stefano Bianchi, Claudio Poggio
Antibacterial efficacy of
conventional and single-use Ni-Ti
endodontic instruments: an in vitro
microbiological evaluation
The International journal of artificial
organs 10/2012

23

23

Join us
on Facebook

06/14

Rf. 60301645-E

Pictures non contractual MICRO-MEGA reserves the right to modify the characteristics of its instruments without notice.

www.micro-mega.com

JC.AUG n www.jcauge.com

Micro-Mega
5-12, rue du Tunnel
25006 Besanon Cedex - France
Tel.: +33 (0)3 81 54 42 34
Fax: +33 (0)3 81 54 42 39
mmid@micro-mega.com

You might also like