Bladder Tank - Industrial Professionals - Cheresources

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

12/11/2015

BladderTankIndustrialProfessionalsCheresources.comCommunity

Ch er esou r ces.com Com m u n it y Gen er a lCh em ica lEn g in eer in g For u m In du st r ia lPr ofession a ls

Adsby Google

BladderTank

WaterTankDesign

ExpansionTank

HoldingTank

Featured
Articles
Checkoutthe
latestfeatured
articles.
FileLibrary
Checkoutthe
latest
downloads
av ailableinthe
FileLibrary .
NewArticle
Product
Viscosity v s.
Shear

FeaturedFile
Amine
Sweetening
Preliminary
Design
NewBlog
Entry
Deoiling
Hy drocy clones
postedin
Ankur'sblog
Adsby Google

PressureTankDesign
IndustrialTank
LiquidNitrogenTank

BladderTank
Startedby ROGOR,Nov 3 02 01 504 :3 4 AM
bladdertank ,

Sharethistopic:
0

More

Adsby Google TankPumpVesselTankASMETankTankValves

ROGOR

http://www.cheresources.com/invision/topic/23976bladdertank/#entry99854

Post ed3 0 Nov em ber 2 0 1 5 0 4 :3 4 A M

1/4

12/11/2015

BladderTankIndustrialProfessionalsCheresources.comCommunity

(http://www.cheresources.com/invision/uploads/monthly_11_2015/post

2939280704583001448837804.png)

Iamdesigningthesystemdescribedintheattachedschematic.IneedhelpsizingtheBladderTankandtheappropriate
startupprocedurepressurizingthebladdertank.IhavenothadmuchluckworkingwiththeBladderTanksuppliers.Can
someoneprovidemewithdirectiontoaknowledgeable(experienced)source?

Post ed0 4 Dec em ber 2 0 1 5 0 1 :0 1 PM

Chemitofreak
Hopethisishelpful.
AttachedFiles
(http://www.cheresources.com/invision/index.php?
app=core&module=attach&section=attach&attach_id=10596)

ASHRAE_Journal___Understanding_Expansion_T anks_T aylor_Proof.pdf


(http://www.cheresources.com/invision/index.php?
app=core&module=attach&section=attach&attach_id=10596)806.51KB1 3 downloads

Post ed0 4 Dec em ber 2 0 1 5 0 4 :4 8 PM

ArtMontemayor

Rogor:

Idontbelieveanyonecanfurnishyouwithanoperating,startuporshutdownprocedurewithouthavinga
detailed,asbuilt,P&ID(Piping&InstrumentationDiagram)andtheabilitytodiscussadetailedHazop.
YourPFD(ProcessFlowDiagram)istoosimplifiedfortechnicaloroperationaldiscussion.Weareunable
toaccuratelyinterpretwhatistheintent,design,andscopeofthesystemyoushow.

Forexample,youshowsomethingthatcannotbeasteadystateprocess:asteamheatedexchanger
followedbyachilledwatercooler.Noonedoesthisinreallifesteadystate.Youeitherheatthecirculated
waterorthechillthecirculatedwater.Youdontdobothoperationssimultaneouslyundersteadystate
operation.CorrectmeifIamwrong,butIthinkyouroperationinvolveseither/oroperationoftheheating
orchillingexchangers.Ifthatisthecase,itisimportanttoindicatethisonaP&IDandsubjectittoa
Hazopreviewpriortofinaldesign.

IamattachingacopyofthesubjectASMEarticlethatIconvertedtoaWorddocumentforbetterreading.
IhaveusedthisdocumentinpriordesignsandIconsideritagoodoutlineandgeneraltechnicaldescription
ofanexpansion(orbladder)tank.Pleasenotetheimportanceofidentifyingtheproperandsafedesign
pressure.Eachexpansiontankapplicationisauniqueoneandshouldbedesignedindividually.You
cannotlogicallydesignordescribeyourspecificsystemusinggeneralizedequationsordescriptions.Thatis
whyaP&IDandaHazoparerequiredforproper,safedesign,installation,andoperation.Startup,
shutdown,andoperatinginstructionsshouldincorporateHazopfindings.Iamnotfamiliarwith
Pharmaceuticalindustrydesignprocedures,butIwouldcertainlyapplyOSHAandstandardengineering
proceduresandpractices.Forexample,considertheworstcasescenarioforeachoftheexchanger
operations.Whatisthemaximumpressure(andvacuum)possibleineachoperatingcase?Youcertainly
shouldprotecttheexpansiontank(andtheclosedsystem)withapressurereliefvalve.Andthisisnormally
http://www.cheresources.com/invision/topic/23976bladdertank/#entry99854

2/4

12/11/2015

BladderTankIndustrialProfessionalsCheresources.comCommunity

notshownonaPFDsuchasyours,butonaP&ID.And,asexplained,thisdependsonhowyouare
operatingthesystemandhowitisprotected.

(http://www.cheresources.com/invision/index.php?app=core&module=attach&section=attach&attach_id=10597)
UnderstandingExpansionT anks2.docx(http://www.cheresources.com/invision/index.php?
app=core&module=attach&section=attach&attach_id=10597)491.7 KB1 0downloads

Post ed0 7 Dec em ber 2 0 1 5 0 9 :3 6 PM

ROGOR
Art

Thankyouforthefeedback.Iappreciateyoutakingthetimetorespondandtosendthearticle"UnderstandingExpansion
Tanks",tome.Youarecorrectinthinkingtheheatingandcoolingareeither/ortypeoperations.Thetransferwateris
heatedwithsteam(5barg)andinturnthetransferwaterheatstheproductslurryto130C.Thetransferwatertemperatureis
controlledsuchthattheproductslurrytemperatureisheldat130Cforapproximately1hour.Aftertheholdingtime,the
transferwateriscooledwithchilledwater(8C)andthetransferwaterinturncoolstheproductslurryto30C.Iwaslooking
fordirectiontoaknowledgeablesourcetoworkwith.Ijustincludedmaximumandminimumtemperaturesinmysimplified
schematic.ThepressuresinthesystemarewhatIamnotsureof.Iunderstandthebladdertankmustbepressurizedinorder
tokeepthewaterfromboilingduringtheheatupprocess.Istheairsideofthebladdertankpressurizedtosay10%higher
pressurethanthevaporpressureofwateratthehighesttemperature?Isthewatersidepressurizedatallafterbeingcharged
withwaterandpriortoturningonthepump?Nottooworriedaboutthecooldownprocess.Iunderstandwewillrequirea
pressurereliefvalveonthesystem.ThelargeHX1isdisassembledbiweekly(tobecleaned)andthetransferwaterloopis
drainedduringthistime.Iwanttomakesurethetransferwaterloopisstartedupsafelyandproperlyeachtime.

Post ed0 8 Dec em ber 2 0 1 5 0 1 :1 3 A M

BobbyStrain

Withtherequirementsyoudescribe,youmightconsidersomethingotherthanwaterasacirculatingmedium.Tokeepfrom
losingwaterduringthehotcycle,thepressureshouldbemaintainedtokeepfromventingwhateverblankedgasusedto
maintainaminimumpressureduringthecoldcycle.Inanyevent,withtheclosedcyclewillwanttouseaglycolandwater
solutionwithappropriateinhibitors.Maybepureethyleneglycolwouldbemoreapplicabletoavoidhighpressureduringthe
hotcycleorlosingwater.

Bobby

Post ed0 8 Dec em ber 2 0 1 5 0 2 :5 7 A M

ArtMontemayor

Rogor:

Bobby'stipsareverygoodadviceandtheonlythingIcouldaddwouldbetousePropyleneGlycolinthe
eventyouareconcernedwithanyleakageandpossibleslurrycontaminationpertainingtofoodgrade
contamination(sincethisis,Ibelieve,apharmaceuticalapplication).Propyleneglycolisapprovedfor
consumableproducts.

AttachedisanExcelsketchofwhatIenvisionisamoreaccuratedepictionofyoursetup.Ifthesetupis
accurate,youshouldhavenoprobleminsizingtheproperandsafeexpansiontank.Designingtheclosed
systemforamaximumpressureequalto5bargshouldnotbeabigdealand,dependingonthephysical
size,mightbedonewithconventionalpipingandsteelmaterials.safelycontaining5bargina12inch
diameterdrumdoesnotrequireabigtankwallthicknessandIwouldnormallyuseaseamlesspipewith
twoellipsoidalpipecapsforthetank.Thenitrogenchargeyouuseisnotgoingtobeanythingbutasmall
amountofpressureenoughtoallowfortheinertingandfortheexpansionofthethermalliquidfluidwhen
itgetshot.Youcaneasilycalculatetheamountofliquidexpansionvolumebetweenthelowestandhighest
temperatureachievable.

http://www.cheresources.com/invision/topic/23976bladdertank/#entry99854

3/4

12/11/2015

BladderTankIndustrialProfessionalsCheresources.comCommunity

Ishowa3waycontrolvalve,butyoucanusemanualblockvalves.Idon'tshowanynecessarydrain
valvesandbypassesaswellasotherdetails.Ithinkthatisyourjob.

IftheExceldrawingisnotanaccuratedepictionofwhatyouintendoriftherearemistakes,thenuseflags
andExcelcalloutstoshowwhatisdifferentordrawyourownsketchthatcanbeeditedorcommentedon
byourmembers.Thatway,onedocumentisusedforthedurationofthethreadandeverymemberthat
cancontributeisfreetogeneratearevision(aslongasitistaggedappropriately).

Ihopethishelpsyou.

(http://www.cheresources.com/invision/index.php?app=core&module=attach&section=attach&attach_id=10605)
ExpansionT ankApplication.xlsx(http://www.cheresources.com/invision/index.php?
app=core&module=attach&section=attach&attach_id=10605)216.41KB1 4 downloads

Post edY est er da y , 0 7 :4 0 PM

ROGOR
Art

Thankyouforthehelp.ThearticleyousentwasveryhelpfulandIhavemyanswer.Also,thereasonImustuseplainwater
isbecausethelargeHX1isdisassembledeachweekforcleaningfluidcontainedthereinislosttodrain.Thesystemisthen
rechargedwithwaterandawaywego.

BacktoIndustrialProfessionalsNextUnreadTopic

RadarT ankGaugingSystemInaccuracy
Startedby Guest_sam eera9 2 _*,Yesterday ,1 1 :3 3 PM

PhosphoricAcidStorageT ank
Startedby Guest_sham ir_*,1 5Sep2 01 5

MegT ransferIsoT ankT oStorageT ank(OffshorePlatform)


Startedby Guest_grax2 1 3 _*,1 9 Nov 2 01 5

PvrvForACondensate+WaterT ank
Startedby Guest_v anecnr_*,01 Dec2 01 5

PressureDropInHelicalTankCoil
Startedby Guest_jim bo2 8_*,2 5Sep2 01 5

2 replies
4 3 v iews

Today ,06 :02 AM

2 replies
3 05v iews

06 Dec2 01 5

4 replies
2 2 9 v iews

06 Dec2 01 5

4 replies
1 82 v iews

02 Dec2 01 5

6 replies
6 7 0v iews

3 0Nov 2 01 5

Ch er esou r ces.com Com m u n it y Gen er a lCh em ica lEn g in eer in g For u m In du st r ia lPr ofession a ls

http://www.cheresources.com/invision/topic/23976bladdertank/#entry99854

4/4

You might also like