4 PRINCIPLE

4 FEATURES AND APPLICATIONS

The capacitance level sensor measuring principle is


base on the " capacitance effects " , when this level
sensor is set on a silo, it will be formed a condenser
between the detector electrode and the silo wall.
The capacitance of this condenser varies
proportional to the change of material specific
inductivity ( DK value) of the material stored in the
silo , when the more material substances increased
in the silo, the more capacitance value added
simultaneously, then it will let his interior circuit 's
resonant signal to create a bigger amplitude ,and
such a signal amplitude become more or less than
factory default threshold value, the relay device will
be energized.
when the sensor probe is not covered, the dielectric
constant =1 ( air enviroment is usually = 1), when
the detected probe is covered by substance
material, and the changes of its capacitance will be
increased and dectected, whereby the liquid or
powdery level is detected.

Because the Capacitance Level Sensor has no


moving parts inside the device, it will not be affected by friction. It is suitable for powder or liquid
application easy to install. The customer can
choose the types for his requirements.

1. Standard Type (SA110 & SA111 A/B/C)


Suitable for general use.
2. Hi-Temp Type (SA120 & SA128 A/B/C)
Suitable for high temperature environment.
3. Anti-Corrosion Type (SA130 & SA132 A/B/C)
Suitable for corrosive environment.
4. Remote Probe Type (SA140 A/B/C)
For use with vibrator equipped with tank.
5. Wire-Probe Type (SA150 A/B/C)
Suitable for silo or deeper tank.
6. Plate-Probe Type (SA160 A/B/C)
Suitable for granules and at lower position of tank
side.

C
e

7. Explosion-Proof Type (SA170D ~ SA178D)


Equipped with SA-75U signal conditioner can be
used in hazardous areas.
8. Anti-Static Type (SA180 & SA181 A/B/C)
Suitable for electrostatic environment
(It won't be damaged by the electrostatic discharge)

2r
2R
C= e l/log(R/r)

4 CONSTRUCTION

1. Probe : SUS304 or SUS316


2. Insulation : UPE or PTFE
3. Grounding Sleeve : SUS304 or SUS316
4. Connection : SUS304 or SUS316
1"PT (default) or 3/4"PT(option)

5. Housing : ADC-12 Aluminum IP65


6. Conduit opening : 1/2"PF or 3/4"PF
7. O-RING : NBR
8. PC board : A, B, C, D Type
9. Sensitivity adjustment : 10pf (std.), 20pf, 40pf
10.Cover ADC-12 Aluminum

TYPE

f118

f118
f118

1/2"PF
1/2"PF

f88

60

1/2"PF
25
1"PT

Dimension

1"PT

25

25

302

1"PT

80

462

402

f21

50

80
f21

50 150(L...)

material

UPE

50

material

UPE

250(L...)

50

material

250(L...)

PTFE

50

120

f27

120

f12.7
f12.7

SA110 A/B/C

SA111 A/B/C

SA120 A/B/C

[ STANDARD TYPE ]

[ STANDARD TYPE ]

[ HI-TEMP. TYPE ]

Operating
Temp.

-20LC~80LC

-20LC~80LC

-20LC~200LC

Probe
Material

SUS 304

SUS 304

SUS 304

Insulated
Material

UPE

UPE

PTFE

Connection

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

Order No.

Sensitivity
Range
Weight

10pf (std.)
20pf, 40pf (option)

10pf (std.)
20pf, 40pf (option)

Approx. 1.9kg

Approx. 1.9kg

10pf (std.)
20pf, 40pf (option)
Approx. 2.4kg

Housing
Spec.

Aluminum IP65

Supply
Voltage

110/220VacK10% or 24Vdc

Delay
Time

0~6 seconds

Power
Consumption

2W

Output
Rating

Relay: 5A/240Vac or 5A/30Vdc, SPDT or Transistor: NPN 100mA

If length of sensing probes longer than 3 meters, please chose 20pf or 40pf sensitivity type.

STANDARD TYPE

f118

f118

f118

1/2"PF

1/2"PF
1/2"PF

f140

f140

145

Dimension

14

f155

25
620

105

413

4- f19

130

4- f15

4- f19

105

material

255(L...)

250

PVDF

material

UPE

330(L...)

f55

Material

PP

40

material

CERAMIC

40
f40

f28

f25

SA128 A/B/C

SA130 A/B/C

SA132 A/B/C

[SUPER HI-TEMP. TYPE ]

[ CORROSION-PROOF TYPE ]

[ CORROSION-PROOF TYPE ]

Operating
Temp.

-20LC~800LC

-20LC~80LC

-20LC~120LC

Probe
Material

SUS 304

SUS 304
Wetted part: PP coating

SUS 304
Wetted part: PVDF coating

Insulated
Material

CERAMIC

UPE

UPE

Connection

3"x5kg/cm2 Flange (SUS)

1-1/2"x10kg/cm2 Flange (PP)

1-1/2"x10kg/cm2 Flange (SUS)


with PVDF Washer (5mm)

Order No.

Sensitivity
Range
Weight

10pf (std.)
20pf (option)

10pf (std.)

Approx. 6.5kg

Approx. 2kg

10pf (std.)
20pf (option)
Depend on the length

Housing
Spec.

Aluminum IP65

Supply
Voltage

110/220VacK10% or 24Vdc

Delay
Time

0~6 seconds

Power
Consumption

2W

Output
Rating

Relay: 5A/240Vac or 5A/30Vdc, SPDT or Transistor: NPN 100mA

If length of sensing probes longer than 3 meters, please chose 20pf or 40pf sensitivity type.

STANDARD TYPE

112

f65

f118

Deep = 77

STD.:1.8M
Max.:5M
1/2"PF
material

195

25
1"PT

1"PT

1/2"PF
2- f7.5

80

356
f21

UPE

80

f155

f21

25

Dimension

290

50
material

250(L...)

f118

f 96

70

UPE
3M(L...)

50

f75

4-f15
f130

f9

1/2"PF

material

UPE

150

120

189
M8

150

f12.7

f28

SA140 A/B/C

SA150 A/B/C

SA160 A/B/C

[ REMOTE PROBE TYPE ]

[ WIRE-PROBE TYPE ]

[ PLATE TYPE ]

Operating
Temp.

-20LC~100LC

-20LC~80LC

-20LC~80LC

Probe
Material

SUS 304

SUS304 cable

SUS 304

Insulated
Material

UPE

UPE

UPE

Connection

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

2-1/2"x 5kg/cm2 Flange (SUS)

Sensitivity
Range

10pf (std.)

10pf (std.)
20pf, 40pf (option)

10pf (std.)
20pf, 40pf (option)

Weight

Approx. 3kg

Approx. 4.1kg

Approx. 3.2kg

Order No.

Housing
Spec.

Aluminum IP65

Supply
Voltage

110/220VacK10% or 24Vdc

Delay
Time

0~6 seconds

Power
Consumption

2W

Output
Rating

Relay: 5A/240Vac or 5A/30Vdc, SPDT or Transistor: NPN 100mA

If length of sensing probes longer than 3 meters, please chose 20pf or 40pf sensitivity type.

INTRINSICALLY SAFE EXPLOSION PROOF TYPE

f118

f118

f118

1/2"NPT

1/2"NPT
1/2"NPT

f88

25
60

1"PT

25
1"PT
1"PT

80
f21

material
PTFE

80
f21

250(L...)

PTFE

50

material

250(L...)

PTFE

f12.7

120

70

3M(L...)

50

material

50

462

402

80

f21

25

Dimension

290

f9

120
M8

f12.7

150
f28

EXPLOSION PROOF

Order No.

SA170D (with SA-75U)

EXPLOSION PROOF

SA172D (with SA-75U)

EXPLOSION PROOF

SA175D (with SA-75U)

[ STANDARD TYPE ]

[ HI-TEMP. TYPE ]

[ WIRE-PROBE TYPE ]

Operating
Temp.

-20LC~80LC

-20LC~200LC

-20LC~80LC

Probe
Material

SUS 304 / SUS 316

SUS 304 / SUS 316

SUS 304 / 316 cable

Insulated
Material

PTFE or UPE

PTFE

PTFE or UPE

Connection

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

10pf (std.)
20pf, 40pf (option)

10pf (std.)
20pf, 40pf (option)

Sensitivity
Range
Weight

10pf (std.)
20pf, 40pf (option)
Approx. 1.9kg

Approx. 2.4kg

Housing
Spec.

Aluminum IP65

Supply
Voltage

16~24Vdc

Enclosure
Protection

NEPSI Ex (ia) IIC

Power
Consumption

2W

Output
Rating

Transistor: NPN 100mA

If length of sensing probes longer than 3 meters, please chose 20pf or 40pf sensitivity type.

Approx. 4.1kg

INTRINSICALLY SAFE EXPLOSION PROOF TYPE

f118

f118

1/2"NPT

material

UPE

1/2"NPT

f88

60
25

f155

Dimension

1"PT

f 96

f75

f118

25
80

4-f15
f130

412

472

260(L...)
150

1/2"NPT

189

EXPLOSION PROOF

Order No.

80

1"PT

SA176D (with SA-75U)

260(L...)

material

PTFE
f21

material
PTFE

f21

EXPLOSION PROOF

SA177D (with SA-75U)

EXPLOSION PROOF

SA178D (with SA-75U)

[ PLATE TYPE ]

[ ANTI-STATIC TYPE ] HI-TEMP.

[ ANTI-STATIC TYPE ]

Operating
Temp.

-20LC~80LC

-20LC~200LC

-20LC~80LC

Probe
Material

SUS 304 / SUS 316

PTFE coating

PTFE or UPE coating

Insulated
Material

PTFE or UPE

PTFE

PTFE or UPE

Connection

2-1/2"x 5kg/cm2 Flange (SUS)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

Sensitivity
Range

10pf (std.)
20pf, 40pf (option)

10pf (std.)
20pf, 40pf (option)

10pf (std.)
20pf, 40pf (option)

Weight

Approx. 3.2kg

Approx. 3.1kg

Housing
Spec.

Aluminum IP65

Supply
Voltage

16~24Vdc

Enclosure
Protection

NEPSI Ex (ia) IIC

Power
Consumption

2W

Output
Rating

Transistor: NPN 100mA

If length of sensing probes longer than 3 meters, please chose 20pf or 40pf sensitivity type.

Approx. 2kg

ANTI-STATIC TYPE

f118

f118

1/2"PF
1/2"PF

f88

60
25
1"PT

25

80

Dimension

1"PT

412

80

472

260(L...)
material
UPE

260(L...)

material

PTFE
f21

f21

SA180 A/B/C

SA181 A/B/C

[ ANTI-STATIC TYPE ]

[ ANTI-STATIC TYPE ] HI-TEMP.

Operating
Temp.

-20LC~80LC

-20LC~200LC

Probe
Material

UPE coating

PTFE coating

Insulated
Material

UPE

PTFE

Connection

1"PT screw (SUS)(default)


or
3/4" NPT(option)

1"PT screw (SUS)(default)


or
3/4" NPT(option)

Sensitivity
Range

10pf (std.)
20pf (option)

10pf (std.)
20pf (option)

Weight

Approx. 2kg

Approx. 2.5kg

Order No.

Housing
Spec.

Aluminum IP65

Supply
Voltage

110/220VacK10% or 24Vdc

Delay
Time

0~6 seconds

Power
Consumption

2W

Output
Rating

Relay: 5A/240Vac or 5A/30Vdc, SPDT or Transistor: NPN 100mA

If length of sensing probes longer than 3 meters, please chose 20pf or 40pf sensitivity type.

SA-75U INTRINSIC SAFE SIGNAL CONDITIONER


16Vdc
SIGNAL INPUT

0V

SA-75U Zener barriers inside provide intrinsic safety


to SA179D type level sensor. The unit works via a
current-limiting feature which protects the device
from damage by emission of sparks.

PWR
ON

75

SA-75U

1. Supply voltage :

110 / 220Vac

2. Power consumption : 2W
3. Input signal :
4. Output voltage :

NPN transistor
resistance Ri= 500W

0V 220V COM
110V NC NO

16~24 Vdc

45

5. Short circuit current : 25mA max.


6. Relay output :

SPDT
10A /30Vdc
10A /220Vac

7. Operating temp. :

-20BC ~ 60BC

8. Weight :

0.3 kg

9. Enclosure rating :

Ex (ia) IIC T6

110

4 WIRING CONFIGURATION
Wall

(Hazardous area)
SA179D

(Non-hazardous area)

SA-75U

16Vdc

AWG 18H3C electric cable

IN

SA-75U

Remote Control Room

ADJUSTMENT

4 COARSE CALIBRATION

4 DELAY FUNCTION CALIBRATION

Set the "Sensitive ADJ. " to the "H" position. Then


use a screw driver to adjust the "Coarse" until
indicator is lighted. At last check "Indicator" is light
or not by adjust the "Sensitivity Adj" knob, if not,
repeat procedure.

The default setting is 0 second, here at the


material is in contact with probe will illuminate
"Indicator" lamp and energize relay. When the
user need to use this delay function, please set
timer in clockwise. The relay will energized after
"Indicator" illuminate for several seconds if set
timer more than 0 second. The delay function is
suitable for variable material level. e.g. liquid tank
equip with agitator.

4 SENSITIVITY ADJUSTMENT
When the material is out of contact with probe will
extinguish the "Indicator". When the material is in
contact with probe will illuminated the "Indicator "
lamp, at this time please adjust "Sensitivity ADJ."
until lamp is in extinction. And then set "Sensitivity
ADJ." in the middle between "H" and extinction
position. e.g. If extinction position is 10p, you
should set "Sensitivity ADJ." in "75" position.

SENSITIVITY ADJ.
60

50

40

70

30

80

20

90

10
L

SA140
LEVLE SENSOR

INDICATOR

SERIES No.

DELAY

SENSITIVITY-No.

COARSE

0V

110V 220V

SA-TYPE LEVEL SENSOR


SERIES No.
SENSITIVITY-No.

10

90

20

80

SENSITIVITY ADJ
60 50 40 3
0
70

Braided shield

INDICATOR

DELAY

To sensor
coaxial cable
C=120 ~ 135

COARSE
NC

NO COM

AC0V 110V 220V

Remote Probe Type (SA140 A/B/C)


Normal close
Normal open
Common

Power
Source

SA110, 120, 130, 150, 160, 179, 180 A/B/C/D

Power
Source
Normal close
Normal open
Common

INSTALLATION NOTICE

A
Connecting pipe

25mm max.

a
B

f100
L
L>30mm

SA110

The insensible portion should


be mounted to protrude 30mm
from the vessel wall. That's to
prevent malfunction from a fill
material or an insufficient clearance between probe and connection pipe.

SA160

SA160 to be mounted properly,


the vessel walls should not exceed 25mm.

To prevent false readings, users


have to make sure the material
flows symmetrically. If the inlet is
not located in the center portion
of the tank roof, check the flow
pattern (a angle) of your material
and place the probe in the appropriate location.

SA150

300mm

SA140

SA160

If the probe is mounted on the


top, make sure the length of
probe long enough to touch the
highest level of raw material.
SA150 type must have at least
300mm from the electrode
probe to the silo wall.
SA160 type is usually installed
at the lower of tank side.

For Non-Stationary or vibrating


environment, a separate control
unit such as the SA140 is suggested.

10

It is suggested to install the


probe away from the inlet to reduce the risk of inflowing material damaging the probe. If the
probe is near an inlet, it is recommended to place a protective
cover 200mm above the probe.
The cover should be parallel to
the probe and the same length.

INSTALLATION NOTICE

300mm

300mm

If two parallel probes are


mounted, they must be
installed separately at least 300
mm to minimize interference .

The probe should not be


mounted underneath a liquid
inlet, otherwise it will switch on
erroneously.

If the tank equips with agitator,


please use the time-delay type
(SA999 -A~D) to prevent
fault level detection.

Mounting the probe at a 20B


incline will optimize the results
and increase sensitivity. It also
won't be damaged by the
inflowing material.

Mounting the probe at top of


tank can avoid material bridges
from forming. It's helpful to
record accurate measurements.

20L

The cable inlet should face


downward to avoid rain
damage. Tighten the cable with
the connecting part.

11

ORDER INFORMATION

SA 1 1 0 A D Q 0 2 5 0
Model
110 --- Standard Type
120 --- Hi-temp. Type
130 --- Corrosion Proof Type
140 --- Remote Probe Type
150 --- Wire Probe Type
160 --- Plate Type
170 --- Explosion Proof Type
180 --- Anti-static Type

Terminal Arrangement
A---110/220Vac, Relay output
B---24Vdc, Relay output
C---24Vdc, NPN transistor output
D---Designed for use with SA-75U

0 110 220

SA999 A

0 24

SA999 B

110V/220VAC

DC24V

Relay output

Relay output

SA999 C
DC24V
Transistor npn output

0V 24V OUT

16~

0V 24V OUT

SA999 D
Ex (ia) IIC
Control unit output

0V

NO
COM
NC
220V
110V
0V

INPUT
16VDC
0V

R
+24Vdc

RELAY OUTPUT

AC SUPPLY

SA-75U

External power supply

Connection
C---3/4"(20A)
D---1"(25A)
E---1-1/2"(40A)
F---2"(50A)
G---2-1/2"(65A)
H---3"(80A)
I ---4"(100A)
J---5"(125A)
K---6"(150A)
S---Others

M---5kg/cm 2
N---10kg/cm 2
O---150 Lbs
P---300 Lbs
Q---PT
R---PF
T---BSP
U---NPT
V---GAS
S---Others

W---PN 10
X---PN 16
Y---PN 25
Z---PN 40

Probe Length (mm)


Q Tolerance of the total product length is K5mm.
Q Characteristics, specifications and dimensions are subject to change without notice.
Q Please contact your nearest distributor office for further informations.

12

You might also like