Features:
absolutely maintenance-free design
stepless adjustable output voltage
safety control according to VDE 0104
short-circuit protected by internal current limitation
voltage indication: 2 range analogue meter, ratio 1:3
current measurement: 3 range analogue meter, decadic
thermal overcurrent switch-off
headoffice@baur.at
www.baur.at
T +435522/4941-0
F +435522/4941-3
Id.Nr. 826-040
09/2012 Subject to alteration
350
max. admissable
output voltage 260 kV
300
250
200
max. admissable
output voltage190 kV (RMS)
150
100
50
0
0
10
15
20
Technical data
Mains supply
Mains frequency
Power consumption
Power consumption short-circuit
Nominal output voltage AC rms / DC
Output current cont. AC rms / DC
Short-circuit current AC rms / DC
Relative humidity
Ambient temperature
Precision of the kV-meter
Precision of the mA-meter
Dimensions control unit housing (W x H x D)
Dimensions High Voltage unit (height / diameter)
Weight control unit
Weight High Voltage unit
headoffice@baur.at
www.baur.at
T +435522/4941-0
F +435522/4941-3
PGK 260 HB
220 - 240 V
110 - 120 V with external
autotransformer
45 Hz up to 60 Hz
2600 VA
5000 VA
190 kV / 260 kV
9 mA / 4 mA
20 mA / 20 mA
not condensing
working: 0 ... + 45 C
storage: - 20 ... + 60 C
2,5 %
2,5 %
502 x 241 x 290 mm
2050 mm / 1270 mm
19 kg
280 kg
Id.Nr. 826-040
09/2012 Subject to alteration
headoffice@baur.at
www.baur.at
T +435522/4941-0
F +435522/4941-3
Id.Nr. 826-040
09/2012 Subject to alteration