Professional Documents
Culture Documents
Convection Section Cleaning
Convection Section Cleaning
Convection Section Cleaning
html
Table 2
Coil
Fouling
Duty
Percent Potentlal Selected for
Savings
Factor
Cleaning
MM Btu/Hr
Fouling Impact
Factor
Energy
Mixed Feed
13.5
0.011365
45.85
0.5211
13.5
HT Proc Air
0.011529
15.94
0.1838
4.8
92.67
1.3945
36.2
75.70
0.6653
17.2
Feed Prht
0.007754
29.90
0.2318
6.0
BFW Prht
19.8
0.009868
77.57
0.7655
19.8
Fuel Prht
0.004771
8.60
0.0410
1.1
LT Proc Air
0.004306
12.62
Total
86.7
0.0543
3.8573
1.4
100.0
Base
Clean Entire
Clean MixedConvection
Feed, HT/LT Stm
Section - 50%
and BFW Coils
Reduced
50% Reduced
Fouling
Fouling
Furnace Fired Fuels
Nat Gas Fuel, SCFH
923814
NG Btu/SCF LHV/HHV
932.92 / 1034.4
Cryo Fuel, SCFH
182805
Cryo Fuel Btu/SCF LHV/HHV
245.54 / 288.18
Low Press Purge, SCFH
19540
LP Purge Btu/SCF LHV/HHV
345.46 / 404.82
937897
932.92 / 1034.4
182805
245.54 / 288.18
19540
345.46 / 404.82
922247
932.92 / 1034.4
182805
245.54 / 288.18
19540
345.46 / 404.82
860.38
Cryo Fuel
44.88
44.88
44.88
LP Purge
6.75
6.75
926.61
912.01
88.70
90.13
Base
-1.57%
6.75
Total
913.47
Furnace Eff, %, LHV
89.99
Fired Fuel Reduction, %
-1.42
Base
14.60
Base
16.19
Base
0.217
Base
$680,000