Ceilings C 46
Ceilings C 46
Ceilings C 46
Ceilings C46
Ceiling tiles
Fire class
B15
Dimensions mm
600 x 600
Thickness mm
70
Surface
13.0 kg/sqm
TNF Magic-faced
steel and Rockwool
slab.
Standard tile
70 mm
600 mm
600 mm
Grid system
Part name
Part code
Standard length
mm
Average consumption
of parts per sqm
ceiling.
Cover profile
TNF 619
2400
See below 1)
Carrier
TNF 611
3600
0.39 pcs/sqm
Cross bar
TNF 612
600
2.72 pcs/sqm
TNF 613
190
1.36 pcs/sqm
TNF 614
240
TNF 615
340
TNF 616
440
TNF 617
540
TNF 618
Felt
TNF 610
1.36 pcs/sqm
1.36 pcs/sqm
25 meters
22 mm/sqm
1) Lin. meters equal lin. meters of top profile flanges. Partition walls: double flanges - lining: single flange.
2) If the distance is less than 280 mm the upper part (TNF 615) can be cut to fit.
Cover profile
TNF 619
TNF 426
34 mm
3 mm
Hanger
TNF 446
Galvanized steel
Upper part:
TNF 614
length: 240 mm
TNF 615
length: 340 mm
TNF 616
length: 440 mm
TNF 617
length: 540 mm
Lock pin:
TNF 618
Lower part:
TNF 613
length: 190 mm
TNF 614
TNF 615
TNF 616
TNF 617
TNF 611
38 mm
TNF 618
TNF 613
24 mm
Felt
TNF 610 Black - 25 meters.
38 mm
TNF 612
TNF 610
22 mm
2 mm
24 mm
Edging Tile:
380
Inside wid
th of cabin
600
Max. 600
: 2780 mm
600
600
Max. 1200
600
600
600
*
*
600
*
*
* These tiles need to be cut to fit.
600
Insi
d
e len
gth
600
in : 3
880
m
of ca
b
600
280
Quantity take-out
When the grid system is marked on the drawing for each
room, the quantity take-out can be done simply by adding
up the number of various parts of the grid system.
When specifying the ceiling please observe the following:
A. Ceiling tiles
specifications on the ceiling tiles must include the following:
- Ceiling colour
choose colour from Colour Chart for TNF Ceilings.
- Number of tiles
(size 600 x 600 mm)
D. Approximate quantities
- The colour of the grid system (if nothing is stated, the grid
system will be supplied in standard white).
1) Carrier, TNF 611
The exact quantity can be calculated by adding up total lin.
m. divided by 3.6 (the length of each carrier).
An allowance of an average of 2% to be added to the quantity calculated. This to allow for proper alignment of the cross
bars and corect distance from top profile to first cross bar.
Installation procedure
Step 1: Carriers - Fig. A
These are placed parallel to the length of the room and
spaced 600 mm apart so that the required ceiling tile
layout is achieved.
The total length of each carrier should be equal to the free
distance between the walls less 10 mm (5 mm free space
at each end).
Two carriers are joined by a special tongue system which
locks the profiles when pushed together .
Ensure that the locking is correct and that the two profiles
are alligned completely.
When installing the carriers, it is important to ensure that
the holes for the cross bars have the preplanned distance
to the insides of the top profiles, so that the cross bars can
be installed correctly and according to layout.
Fig. A
Fig. B
Installation procedure
Fig. C
Fig. D
Carrier
TNF 611
Fig. A
Cross bar
TNF 612
- length 600 mm
Adjustable hanger
TNF 613 - Lower part
TNF 617 - Upper part
TNF 618 - Lock pin
Fig. B
Joint betwen carrier and two
cross bars.
Fig. C
INEXA A/S
Hovedgaden 483, DK-2640 Hedehusene, Denmark
Tel: +45 46 56 37 00, Fax: +45 46 56 04 66
Website: www.inexa.com
DK-A/S reg. No: 63 556, CVR-nr: 15 38 34 37