Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 6

SPECIFICATIONS DIGEST

FOR THE

PROPOSED 3- BEDROOM RESIDENCE


BRGY. JULIANA, CITY OF SAN FERNANDO, PAMPANGA

PREPARED BY:
ENGR. RUDY L. PATAWARAN
PRC Reg. No. 38785

PROPOSED 3-BEDROOM RESIDENCE


PAMPANGA

B RGY. JULIANA, CITY OF SAN FERNANDO,


1

I.

GENERAL

II.

The works under this specification in conjunction with the plans and drawings call for the
complete construction of the PROPOSED THREE (3) BEDROOM RESIDENCE located
at Brgy. Juliana, City of San Fernando, Pampanga. This specification shall apply to every
trade involved and shall be carefully read and complied with by all parties furnishing
materials and executing works.
The materials to be used and involved in this work shall be of the approved quality, free from
defects that may impair the strength, appearance and proper functioning of the structure.

REINFORCED CONCRETE WORKS

III.

IV.

3000psi concrete with intermediate and structural grade deformed reinforcing bars shall be
used for all structural columns, footings, beams, canopies and suspended slabs.
2000psi concrete with structural grade deformed reinforcing bars shall be used for all slabs on
grade, wall footings, counters, stiffener columns and stiffener beams.
Use Intermediate Grade Deformed Reinforcing Steel Bars with aluminum yield stress (Fy) of
414 MPa or 60ksi for sizes 12mm dia. And larger securely tied by ga. 16 G.I. wire.
Use Structural Grade Deformed Reinforcing Steel Bars with minimum yield stress (Fy) of
276 MPa or 40ksi for sizes 10mm dia. And smaller securely tied by ga. 16 G.I. wire

STRUCTURAL STEEL AND MISCELLANEOUS METAL WORKS


Use A36 steel for all sections for miscellaneous grille works unless otherwise specified on the
plans and details. All steel sections shall be epoxy primed upon delivery on site and upon
completion of site fabrication. All surfaces shall be thoroughly cleaned of dusts, burrs, rust
scales and other deleterious materials prior to application of epoxy primer and two (2) top
coats. Use E60 series welding electrodes.

GRILLES

V.

2x2x thk. angle bar on 2x3x1.2 C-Purlins for Trusses


Tubular Bars for window grills and accents at facade in QDE finish.
Stainless Steel Bars for balcony and stair railings.

MASONRY WORKS

350psi 6 thick CHB with structural grade deformed reinforcing bars and cement-sand mortar
shall be used for all perimeter walls.
350psi 4 CHB with structural grade deformed reinforcing bars and cement-sand mortar shall
be used for interior walls, partitions and catch basins.
All exposed sides of CHB masonry walls and structural members shall be provided with at
least 15mm thick cement-sand plaster.
Use 1:3 ratio cement-sand mortar for CHB laying, fillers and plastering works.

PROPOSED 3-BEDROOM RESIDENCE


PAMPANGA

B RGY. JULIANA, CITY OF SAN FERNANDO,


2

VI.

FINISHES
A. FLOOR FINISHES
Living Area / Dining Area / Kitchen
60cm x 60cm granite tiles as per architects approved color and design.
Porch / Veranda / / Balcony
40cm x 40cm non-skid floor tiles with pebble border as per architects approved color and
design
Masters Bedroom / Walk-in Closet @ Ground Floor
40cm x 40cm granite tiles as per architects approved color and design.
Bedroom01/Bedroom02/Bedroom03/Bedroom04/Family Hall/Hallway @ 2nd Floor
Laminated Flooring by Pergo or approved equal as per architects approved color and
design.
Dirty Kitchen & Laundry Area
40cm x 40cm non-skid ceramic tiles as per architects approved color and design.
Powder / Toilet & Shower Area
30cm x 30cm non-skid floor tiles as per architects approved color and design.
B. WALL FINISHES
Interior Concrete Walls
smooth cement plaster finish with two (2) topcoats of semi-gloss latex paint finish as per
architects color schedule.
Exterior Concrete Walls
smooth cement plaster finish with two (2) topcoats of semi-gloss latex paint finish as per
architects color schedule with Stone Cladding finish on portions as shown on plans and
details.
Powder / Toilet & Shower Area
30cm x 30cm glazed wall tiles as per architects approved color and design.
C. CEILING FINISHES
Second Floor
9mm thick Boral board on metal framing system.
Powder Room / Toilet and Shower Area
9mm thick Moisture Resistant (MR) Boral board on metal framing system.
Underslab

PROPOSED 3-BEDROOM RESIDENCE


PAMPANGA

B RGY. JULIANA, CITY OF SAN FERNANDO,


3

smooth cement in flat latex finish as per architects color schedule.

D. KITCHEN COUNTER TOP


Reinforced concrete countertop with polished granite top, fascia and splashboard.

VII.

PLUMBING, DRAINAGE AND WATER LINES

A. PIPES AND FITTINGS


PPR pipes and fittings shall be used for all waterline works by Pilsa or approved
equivalent. They shall be set squarely and perpendicularly to the wall of the building. All
joints shall be carefully done to ensure water tightness.
PVC pipes and fittings shall be used for all sanitary and drainage works fittings by
Crown or approved equivalent.
Gate valves and water meters shall be bronze as approved by the engineer.

B. FIXTURES

Water closets shall be by HCG, Pozzi or approved equivalent

Shower head shall be chromium plated by HCG, Pozzi or approved equivalent.

Lavatories shall be pedestal type by HCG, Pozzi or approved equivalent.


Floor drains and hose bibbs shall be stainless steel as approved by the architect.

VIII. TERMITE PREVENTION

IX.

Use BILFEX 2.5 EC brands for soil poisoning or approved equivalent. Apply
BILFEX 2.5 ECD wood preservative natural color or approved equivalent to all lumber
component of the structure.

DOORS AND WINDOWS


A. DOORS
Main Entrance
Panel swing type door by Pateco on 2x 6 yakal or tanguile door jamb as per architects
approved design.
Bedrooms
Zen series molded Flush door by Patecoon 2x5 yakal or tanguile door jamb as per
architects approved design.
Toilet and Bath
Zen series molded Flush door by Patecoon 2x5 yakal or tanguile door jamb as per
architects approved design.
B. WINDOWS

PROPOSED 3-BEDROOM RESIDENCE


PAMPANGA

B RGY. JULIANA, CITY OF SAN FERNANDO,


4

X.

Analok sliding type windows with 6mm thick glass on aluminum frame as per architects
approved design.

ROOFING

XI.

Roofing shall be 0.40mm thick rib-type long span roofing sheets by Colorsteel or
approved equivalent with complete ridge, valleys, end accessories, complete moisture
barriers and leak protections. Brand, design and color of roofing system shall be approved
by the architect.

ELECTRICAL SYSTEM & FIXTURES

XII.

CARPENTRY AND JOINERY WORKS

XIII.

Use galvanized rigid metal conduit and entrance cap for service entrance.
Use Moldflex flexible PVC pipe or approved equivalent for wiring installation on
concrete walls and ceilings.
Use rigid PVC utility and junction boxes manufactured by Moldex Products Inc. or
approved equivalent.
Use Omni or approved equivalent for flushed wall switches, convenience outlets and
other type of wiring devices.
Use stranded type electrical wires and conductors by Phelps Dodge or approved
equivalent.
Use Nema 1or enamel painted panel boards and breakers manufactured by Fujihaya
Electric or approved equivalent.
Use Ikhea brand or approved equivalent for lighting fixtures.

Lumber shall be approved quality, free from large loose knots any other imperfections that
may affect its appearance and/or impair its strength and durability.
Rough lumber shall be used for all studs and nailers treated with BIFEX 2.5 EC wood
treatment
Smooth kiln dried lumber for ceiling cornices, baseboards, doors jambs and panel doors
shown on schedule.

FINISHING HARDWARES

Locksets
Main Entrance Knob type with dead lock by Direct Hardware or approved equal .
Bedrooms / T&B Knob type by Direct Hardware or approved equal.
Hinges
Loose pin by Direct Hardware or approved equal.
Concealed hinges Direct Hardware or approved equal for cabinets & closets.
Door Stopper
Direct Hardware or approved equal.
Wood pull-out handle
PROPOSED 3-BEDROOM RESIDENCE
PAMPANGA

B RGY. JULIANA, CITY OF SAN FERNANDO,


5

Direct Hardware or approved equal.


Drawer Guide
Direct Hardware or approved equal

XIV. PAINTING AND VARNISHING

Firewalls, ledges and canopies apply Wall Guard top coat paint finish by Boysen or
approved equal.
Exterior walls of the structure - Semi-gloss Latex paint finish by Boysen or
approved equal.
Interior walls of the structure Semi-gloss Latex paint by Boysen or approved equal.
Ceilings Flat Latex paint by Boysen or approved equal.
Underslab - Flat Latex paint by Boysen or approved equal.
Closets and cabinets Wood Stain Finish by Boysen or approved equal.

- end of specification-

Conforme:

MR. & MRS. MARCELINO L. PATAWARAN


Owner

PROPOSED 3-BEDROOM RESIDENCE


PAMPANGA

B RGY. JULIANA, CITY OF SAN FERNANDO,


6