Automatic

Valves

Actuators

Accessories

bar

3-position actuator
with additional pistons
twin-piston actuator,
type GTD/GTE and type GCD/GCE
Product description
Two additional pistons make a third (intermediate) position possible. The intermediate position is exactly reproducible. To use for multiple-way valves and pig
valves. Safety function with spring-centered central position.

Technical data
Type

Construction
features
Variants
(functional diagram
see page 2)

pneumatic twin piston actuator, single-acting and doubleacting version with two additional pistons,
pivoting angle 90+ 90 (180)
respectively 120+ 120 (240)
tooth rack and pinion technique with
self-centering piston guidance in the casing;
single-acting: with bar-safety springs
Standard version
Chemical version
with fixed intermediate positions
type GTD-. . / 90+90GCD-. . / 90+90type GTD-. . /120+120GCD-. . /120+120with adjustable indexing and central position = EZE
type GTD-. . / 90+90- EZE
GCD-. . / 90 +90- EZE
type GTD-. . /120+120- EZE
GCD-. . /120+120- EZE

Mounting position
Materials,
Mounting variations,
Spare parts
Ambient temperature
Torques
Control pressure
Control medium,
Quality
Control

with spring-centered and central position


type GTE-. . / 90+90GCE-. . / 90+90random
versions GTD/GTE respectively GCD/GCE
see respective leaflets Actuators
20 to + 95 C
12 to 2370 Nm, on request to 5430 Nm
see leaflets Actuators
2 to 10 bar
filtered air concerning residual oil, residual dust and
water according to
DIN ISO 8573-1/class 4 at least
valve combinations (preferably 3/2-way)
corresponding safety conception respectively
requirements.
- we appreciate to support you concerning the control -

Special features:
several safety conceptions with
different controls are possible
universal mounting possibility
of all signal units to normed
interface points
easy and not dangerous
handling because of
bar-safety springs

Leaflet No.

S1.4-01e-134

3-position actuator
with additional pistons
twin-piston actuator,
type GTD/GTE and type GCD/GCE
Connection C
at GTD/GCD../90+90 and 120+120
Connection C
at GTD/GCD../90+90 and 120+120- EZE

Actuator size

Designation

* 66
A B C D

* 76
E

* 86

A B C D

A B C D

* 96
E

A B C D

GTD/GCD* /90+90-

289 70 118 344 83 130 391 91 138 441 100 147

GTD/GCD * /120+120-

338 70 118 410 83 130 467 91 138 528 100 147

GTD/GCD* /90+90- EZE 391 91 138


GTD/GCD* /120+120-EZE 410 83 130 63 467 91 138
GTE/GCE * /90+90

Designation

333 70 118 11 405 83 130 16 455 91 138 15,5 514 100 147 20

A B C D

Connection C= G 1/8 at actuator size 66 to 86


Connection C= G 1/4 at actuator size 96 to 210

Actuator size
* 163

* 110

* 127
E

A B C D

A B C D

* 210
E

A B C D

GTD/GCD* /90+90-

458 120 170 631 137 190 734 172 228 955 224 285

GTD/GCD * /120+120-

545 120 170 756 137 190 938 172 228 1144 224 285

GTD/GCD* /90+90- EZE 458 120 170 74 631 137 190 92,5
GTD/GCD* /120+120- EZE 545 120 170 82 756 137 190 105 938 172 228 116
GTE/GCE

* /90+90

556 120 170 11,5 751 137 190 18 937 172 228 22,5

Functional diagram
(central position represented)
GTD/GCD-.../90 + 90- and 120 + 120-...-EZE
(with adjustable indexing and central position)

Functional diagram
(central position represented)
GTE/GCE-.../90 + 90
(with spring-centered central position)

bar GmbH
Auf der Hohl 1
53547 Dattenberg / Germany
Phone: +49 (0) 26 44 - 96 07-0
Fax: +49 (0) 26 44 - 96 07 35

www.bar-gmbh.com
eMail: sales@bar-gmbh.com

certificated acc. to DIN EN ISO 9001

bar

Subject to changes in line with technological advances and data variations. by bar GmbH13.04/kb

Functional diagram
(central position represented)
GTD/GCD-.../90 + 90 and 120 + 120
(with fixed intermediate position)