Quantity Measured / Instrument Range/ Frequency Calibration Measurement Capability ( ) Remarks

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

Laboratory

Authentic Instrument & Automation Pvt. Ltd., 31, RIICO Industrial Area,
Jhotwara, Jaipur, Rajasthan

Accreditation Standard ISO/IEC 17025:2005


Discipline

Electro-Technical Calibration

Issue Date

24.04.2015

Certificate Number

C-0686

Valid Until

23.04.2017

Last Amended on

Page

1 of 4

Quantity Measured /
Instrument

Range/ Frequency

* Calibration
Measurement
Capability ()

Remarks

SOURCE
1.

AC VOLTAGE

50 Hz
10 mV to 200 mV
200 mV to 2 V
2 V to 20 V
20 v to 200 V
200 V to 750 V

143 % to 1.13 %
1.13 % to 0.37 %
0.37 % to 1.13 %
1.13 % to 0.33 %
0.33 % to 0.25 %

Using 5 Digit Multifunction


Calibrator, by Direct Method

2.

DC VOLTAGE

1 mV to 200 mV
200 mV to 2 V
2 V to 20 V
20 V to 200 V
200 V to 1000 V

2.02 % to 0.42 %
0.42 % to 0.21 %
0.21 %
0.21 % to 0.62 %
0.62 % to 0.22 %

3.

AC CURRENT

50 Hz
0.2 mA to 2 mA
2 mA to 20 mA
20 mA to 200 mA
200 mA to 2 A
2 A to 10 A
10 A to 100 A
100 A to 1000 A

2.95 % to 0.98 %
0.98 % to 0.55 %
0.55 % to 0.75 %
0.75 %
0.75 %
0.75 % to 2.4 %
2.4 % to 1.22 %

Using 5 Digit Multifunction


Calibrator by Direct Method

1.1 mA to 2 mA
2 mA to 20 mA
20 mA to 200 mA
200 mA to 2 A
2 A to 10 A
10 A to 100 A
100 A to 1000 A

3.12 % to 0.87 %
0.87 % to 0.45 %
0.45 % to 0.64 %
0.64 % to 0.75 %
0.75 % to 0.76 %
0.76 % to 0.80 %
0.80 %

Using 5 Digit Multifunction


Calibrator by Direct Method

4.

DC CURRENT

Naveen Jangra
Convenor

Using 5 Digit Multifunction


Calibrator, by Direct Method

Using 5 Digit Multifunction


Calibrator & Current Coil by
Direct Method

Using 5 Digit Multifunction


Calibrator & Current Coil by
Direct Method
Avijit Das
Program Manager

Laboratory

Authentic Instrument & Automation Pvt. Ltd., 31, RIICO Industrial Area,
Jhotwara, Jaipur, Rajasthan

Accreditation Standard ISO/IEC 17025:2005


Discipline

Electro-Technical Calibration

Issue Date

24.04.2015

Certificate Number

C-0686

Valid Until

23.04.2017

Last Amended on

Page

2 of 4

Quantity Measured /
Instrument

5.

FREQUENCY$

6.

RESISTANCE (4 W)

RESISTANCE (2 W)
7.

8.

9.

10.

CAPACITANCE

INDUCTANCE

Range/ Frequency

* Calibration
Measurement
Capability ()

Remarks

45 Hz to 1 kHz

0.6 % to 0.03 %

Using 5 Digit Multifunction


Calibrator by Direct Method

1 m
10 m
100 m
1 to 100
100 to 1 M
1 M to 900 M

1.15 %
1.15 %
1.51 %
1.18 %
1.16 %
1.16 %

Using Decade Micro Ohm Box


by Direct Method
Using Standard Resistance Box
by Direct Method

2 G
20 G

3%
3.10 %

Using Standard Resistance Box


by Direct Method

1 kHz
10 pF to 1nF
1 nF to 1 F
1 F to 10 F

2.58 %
2.58 %
2.58 %

Using Standard Capacitance


Box by Direct Method

1 kHz
10 H to 1mH
1 mH to 1 H
1 H to 9 H

1.40 %
1.40 %
1.40 %

TEMPERATURE SIMULATION
(INDICATOR/ CONTROLLER/ RECORDER )
RTD Type (PT-100)
(-) 200 C to 800 C

3.36 C

J Type

(-) 200 C to 1100 C

3.74 C

K Type

(-) 200 C to 1200 C

4.68 C

POWER (1 )
Naveen Jangra
Convenor

50 w to 1 kw

0.8 %

Using Standard Inductance Box


by Direct Method

Using Temperature Calibrator


by Direct Method

Using Process Meter Calibrator


Avijit Das
Program Manager

Laboratory

Authentic Instrument & Automation Pvt. Ltd., 31, RIICO Industrial Area,
Jhotwara, Jaipur, Rajasthan

Accreditation Standard ISO/IEC 17025:2005


Discipline

Electro-Technical Calibration

Issue Date

24.04.2015

Certificate Number

C-0686

Valid Until

23.04.2017

Last Amended on

Page

3 of 4

Quantity Measured /
Instrument

Range/ Frequency

* Calibration
Measurement
Capability ()

Remarks

by Direct Method
11.

POWER (3 )

50 w to 1 kw

0.8 %

Using Process Meter Calibrator


by Direct Method

50 Hz
10 mV to 100 mV
100 mV to 750 V

0.54 % to 0.18 %
0.18 %

Using 6 Digit Multimeter, by


Direct Method

MEASURE
1.

AC VOLTAGE

2.

DC VOLTAGE

1mV to 100 mV
100 mV to 1000 V

0.41 % to 0.12 %
0.12 %

Using 6 Digit Multimeter, by


Direct Method

3.

AC CURRENT

0.5 mA to 1 mA
1 mA to 100 mA
100 mA to 1 A
1 A to 10 A

1.03 % to 0.6 %
0.6 % to 0.3 %
0.30 % to 0.17 %
0.17 % to 0.46 %

Using 6 Digit Multimeter, by


Direct Method

4.

DC CURRENT

0.1 mA to 1 mA
1 mA to 1 A
1 A to 10 A

0.36 % to 0.17 %
0.17 %
0.17 % to 0.28 %

Using 6 Digit Multimeter, by


Direct Method

5.

TIME/ STOP WATCH

1 s to 3600 s

1.17 % to 0.11 %

Using Time Calibrator/ Counter


Calibrator by Comparison Method

7.

AC HIGH VOLTAGE
TESTER

1 kV to 25 kV

2.05 % to 3 %

Using High Voltage Probe Fluke


with Fluke Multimeter by
Comparison Method

8.

DC HIGH VOLTAGE
TESTER
Naveen Jangra
Convenor

1 kV to 10 kV

3.07 % to 4.4 %

Using High Voltage Probe Fluke


with Fluke Multimeter by
Avijit Das
Program Manager

Laboratory

Authentic Instrument & Automation Pvt. Ltd., 31, RIICO Industrial Area,
Jhotwara, Jaipur, Rajasthan

Accreditation Standard ISO/IEC 17025:2005


Discipline

Electro-Technical Calibration

Issue Date

24.04.2015

Certificate Number

C-0686

Valid Until

23.04.2017

Last Amended on

Page

4 of 4

Quantity Measured /
Instrument

Range/ Frequency

* Calibration
Measurement
Capability ()

Remarks

Comparison Method
* Measurement Capability is expressed as an uncertainty () at a confidence probability of 95%
#
The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual
environmental conditions and master equipment used.

Naveen Jangra
Convenor

Avijit Das
Program Manager