HTL-04 Thermal Conductivity of Liquid

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Rev no: HTL04/03

Date :01/03/2006

Enriching Engineering Education

HTL-04

EEE THERMAL CONDUCTIVITY OF LIQUID

DESCRIPTION
Thermal conductivity of liquid apparatus is based upon guarded hot plate method. The main

heater in aluminium heating chamber heats a thin layer of liquid. Top portion of this heater is guarded
against heat loss by a top and ring guard heater. A cooling plate removes heat through liquid layer,
ensuring unidirectional heat flow. Temperature is measured across the liquid layer. The apparatus is
insulated by glass wool bags.
FEATURES
1.

Three thermocouples on either sides of the liquid layer enabling to take average temperature.

2.

Ring and top guard heaters ensuring unidirectional heat flow.

3.

Determination of thermal conductivity over wide temperature range.

4.

Electrical input control and measurement with complete panelised instruments.

RANGE OF EXPERIMENTS
1.

Determination of thermal conductivity of liquid.

2.

Study of variation of thermal conductivity with layer thickness and temperature.

3.

Comparison of thermal conductivity of various liquids.

PAGE 1 OF 2

ETERNAL ENGINEERING EQUIPMENT (P) LIMITED


Gat No.382,Mankarwadi Road, Near Sujnil Chemo Industries, Urawade, Pirangoot, 412111 . Tal. Mulshi ,
Dist. Pune Maharashtra State , INDIA.
Tel : +91 20 65600259 / 65600269 / 65600258 / 65600259 / 65600268 Email : mkt@eeepune.com, edquip@gmail.com
WebSite : www.eeepune.com

Enriching Engineering Education

HTL-04

EEE THERMAL CONDUCTIVITY OF LIQUID

SPECIFICATIONS
1.

Hot plate assembly with suitable heater , 100mm diameter

2.

Cold plate assembly with water circulation.

3.

Ring and top guard assembly with suitable heaters.

4.

Glass wool insulation around the apparatus in the housing.

5.

Control panel consisting of:


A) Voltmeter :

0-50/100 volt

B) Ammeter :

0-2 amp

C) Dimmerstats :

0-230 V 2 amp for each heater

D) Digital temperature indicator 0-200c with 0.1c least count using Cr-Al
thermocouples, provided with cold junction compensation
E) Voltmeter and Ammeter selector switch.
SERVICE REQUIRED
230 V ,15 amp electric supply with earthing connection .
Constant head water supply at the rate of about 15 lit/min

FLOOR SPACE
3.5 m x 1 m approximately

INSTRUCTION MANUAL
A manual is supplied with the product which describes the equipment and the test procedure along with
necessary calculations.

Note:
1. Since research and development is an on going activity, the specifications mentioned herein are subject to
Change without notice.
2. Photographs / Illustrations are only indicative in nature and will change with the exact model / specifica
the client.
PAGE 2 OF 2

ETERNAL ENGINEERING EQUIPMENT (P) LIMITED


Gat No.382,Mankarwadi Road, Near Sujnil Chemo Industries, Urawade, Pirangoot, 412111 . Tal. Mulshi ,
Dist. Pune Maharashtra State , INDIA.
Tel : +91 20 65600259 / 65600269 / 65600258 / 65600259 / 65600268 Email : mkt@eeepune.com, edquip@gmail.com