Professional Documents
Culture Documents
Catalogo Optisonic 7300
Catalogo Optisonic 7300
Catalogo Optisonic 7300
OPTISONIC 7300
OPTISONIC 7300
37
6 Notes
www.krohne.com
35
5 Application form
4.4.1
4.4.2
4.4.3
4.4.4
Safety instructions.......................................................................................................... 29
Signal cable (remote versions only)............................................................................... 29
Power supply .................................................................................................................. 30
Inputs and outputs, overview ......................................................................................... 31
29
4 Electrical connections
4.1
4.2
4.3
4.4
25
3.4.1
3.4.2
3.4.3
3.4.4
3.4.5
3.4.6
3.4.7
3.1
3.2
3.3
3.4
3 Installation
2 Technical data
1.1
1.2
1.3
1.4
1 Product features
CONTENTS
PRODUCT FEATURES 1
www.krohne.com
The OPTISONIC 7300 offers an ultrasonic measurement system dedicated for process gas flow
applications. The OPTISONIC 7300 does not have the limitations that are usually associated with
traditional gas flow meters like periodical recalibrations, maintenance, pressure loss and a
limited flow range. The OPTISONIC 7300 combines the advantages of ultrasonic measurement in
a way that it is efficient, reliable and easy to use.
OPTISONIC 7300
FEATURES
Chemicals
Petrochemicals
Power plants
Oil & Gas
www.krohne.com
Applications
OPTISONIC 7300
Industries
Highlights
1 PRODUCT
1.2 Variants
OPTISONIC 7300
www.krohne.com
Connection options
Standard flange range available up to
ASME 900 lb / PN 40. Others on request.
Version
Available as compact or remote version
PRODUCT FEATURES 1
FEATURES
8! '4!&EV
1.3 Features
1 PRODUCT
www.krohne.com
Diagnostics
Important information about both the process and
sensor can be provided by diagnostic values.
Examples are gain for information about pollution in
the sensor, velocity of sound for changes in the gas
composition and signal to noise ratio for changes in
the process.
Transducer design
With the innovative patented design of the
transducers, the OPTISONIC 7300 offers a superior
application range. This new design allows not only a
larger flow and diameter range, but also an
extended range of gases that can be measured.
OPTISONIC 7300
PRODUCT FEATURES 1
www.krohne.com
Like canoes crossing a river, acoustic signals are transmitted and received along a diagonal
measuring path.
A sound wave going downstream with the flow travels faster than a sound wave going
upstream against the flow.
The difference in transit time is directly proportional to the mean flow velocity of the medium.
OPTISONIC 7300
Application range
Volume flow, corrected volume flow, mass flow, molar mass, flow speed, flow
direction, speed of sound, gain, signal to noise ratio, reliability of flow
measurement, quality of acoustic signal
Secondary measured
values
OPTISONIC 7300 C
OPTISONIC 7000 F with GFC 300 F signal converter
1 path: DN50...80 / 2...3"
Compact version
Remote version
Nominal diameter
Self diagnostics
Communication
interfaces
Counters
www.krohne.com
Current (incl. HART), pulse, frequency and/or status output, limit switch
and/or control input (depending on the I/O version)
Inputs / outputs
Signal converter
Measurement range
Modular construction
2 path all welded flow sensor with o-ring fitted titanium transducers.
Features
Design
Transit time
OPTISONIC 7300
Measured value
Measuring principle
Measuring system
2 TECHNICAL DATA
Units
Storage temperature
Ambient temperature
Process temperature
Temperature
Operating conditions
Repeatability
Gas calibration
Theoretical calibration
(standard)
Reference conditions
(for gas calibration)
www.krohne.com
-50+70C / -58+158F
Carbon steel flanges acc. to ASME, min. process temperature: -29C / -20F
-40...+180C / -40...+356F
Remote version
-40...+125C / -40...+257F
Compact version
< 0.2%
DN50...80 / 23": < 2% of actual measured flow rate, for 1...30 m/s
DN100...600 / 424": < 1% of actual measured flow rate, for 1...30 m/s
DN50...80 / 23": < 3% of actual measured flow rate, for 1...30 m/s
DN100...600 / 424": < 2% of actual measured flow rate, for 1...30 m/s
Medium: Air
Language of display
texts
Measuring accuracy
All DTM's and drivers will be available at the internet homepage of the
manufacturer.
4 optical keys for operator control of the signal converter without opening the
housing.
TECHNICAL DATA 2
Menu
Display functions
Remote control
Graphic display
OPTISONIC 7300
10
2...14": 900 lb RF
224: 600 lb RF
224: 300 lb RF
224: 150 lb RF
DN50...80: PN 40
DN100150: PN 16
DN200600: PN 10
Standard
Density
10 DN
20 DN
on page 25.
Transducer holders
(wetted)
Transducers (wetted)
Transducer o-rings
(wetted)
www.krohne.com
Polyurethane
Coating
Option: FFKM
on page 19.
3 DN
DN100:
DN80:
Nozzles transducer
holders (wetted)
Tube
(wetted)
Flanges
(wetted)
Sensor
Materials
Outlet run
Inlet run
Installation
Dry gas
Physical condition
Installation conditions
OPTISONIC 7300
All sensor designs at full rating acc. to below flange standards for standard
materials.
ASME B16.5
EN 1092-1
Pressure
2 TECHNICAL DATA
Cable entries
Signal cable
(remote version only)
Power consumption
Power supply
Electrical connections
Field version
Converter housing
Converter
Connection box
(remote version only)
OPTISONIC 7300
www.krohne.com
5 m / 16 ft
DC: 12 W
AC: 22 VA
Stainless steel
11
TECHNICAL DATA 2
12
Description of used
abbreviations
Passive
www.krohne.com
4V
22 mA
32 VDC
U I = 30 V
I I = 100 mA
PI = 1 W
CI = 10 nF
LI = 0 mH
U0
1.8 V
U0
U ext
22 mA
32 VDC
450
U 0 = 21 V
I 0 = 90 mA
P0 = 0.5 W
C0 = 90 nF / L0 = 2 mH
C0 = 110 nF /
L0 = 0.5 mH
Uext
1k
RL
RL
22 mA
22 mA
U int = 20 VDC
Active
Modular I/Os
Basic I/Os
Uint = 24 VDC
Operating data
Q = 100%: 1020 mA
Q = 0%: 415 mA
With HART
Q = 100%: 1020 mA
Ex-i
Without HART
Settings
Q = 0%: 015 mA
Measurement of volume flow, corr. volume flow, mass flow, molar mass, flow
speed, velocity of sound, gain, diagnostics 1, 2, 3, HART communication.
Output data
Current output
All in-and outputs are galvanically isolated from each other and from all other
circuits.
OPTISONIC 7300
General
2 TECHNICAL DATA
Device drivers
Function
Settings
Active
Basic I/Os
Operating data
www.krohne.com
20 mA
10 k for f 1 kHz
1 k for f 10 kHz
20 mA
open:
I 0.05 mA
closed:
U0,nom = 22.5 V at
I = 1 mA
U0,nom = 21.5 V at
I = 10 mA
U0,nom = 19 V at
I = 20 mA
RL
RL
open:
I 0.05 mA
closed:
U0,nom = 24 V at
I = 20 mA
RL, max = 47 k
Unom = 24 VDC
Modular I/Os
Ex-i
Volume flow, corr. volume flow, mass flow, molar mass, flow speed,
velocity of sound, gain, diagnostics 1,2,3.
Output data
Multidrop
HART version: V5
13
TECHNICAL DATA 2
Load
Description
HART
OPTISONIC 7300
14
NAMUR
Passive
2 TECHNICAL DATA
32 VDC
100 mA
20 mA
www.krohne.com
open:
I nom = 0.43 mA
closed:
I nom = 4.5 mA
open:
Inom = 0.6 mA
closed:
Inom = 3.8 mA
U I = 30 V
I I = 100 mA
PI = 1 W
CI = 10 nF
LI = 0 mH
Passive to
EN 60947-5-6
Passive to
EN 60947-5-6
open:
I 0.05 mA at Uext = 32 VDC
closed:
U0, max = 1.5 V at I 1mA
U0, max = 2.5 V at I 10 mA
U0, max = 5.0 V at I 20 mA
RL 10 k for f 1 kHz
RL 1 k for f 10 kHz
RL, max = (Uext - U0) / Imax
open:
I 0.05 mA at Uext = 32 VDC
closed:
U0, max = 0.2 V at I 10 mA
U0, max = 2 V at I 100 mA
RL, max = 47 k
RL, max = (Uext - U0) / Imax
Uext
OPTISONIC 7300
www.krohne.com
open:
I nom = 0.43 mA
closed:
I nom = 4.5 mA
open:
Inom = 0.6 mA
closed:
Inom = 3.8 mA
U I = 30 V
I I = 100 mA
PI = 1 W
CI = 10 nF
LI = 0 mH
Passive to
EN 60947-5-6
Ex-i
Passive to
EN 60947-5-6
open:
I 0.05 mA at
Uext = 32 VDC
closed:
U0, max = 0.2 V at
I 10 mA
U0, max = 2 V at
I 100 mA
100 mA
open:
I 0.05 mA at
Uext = 32 VDC
closed:
U0, max = 0.2 V at
I 10 mA
U0, max = 2 V at
I 100 mA
Uext = 32 VDC
open:
I 0.05 mA
closed:
U0, nom = 24 V at
I = 20 mA
RL, max = 47 k
RL, max = (Uext - U0) /
Imax
100 mA
20 mA
RL, max = 47 k
Uint = 24 VDC
RL, max = 47 k
RL, max = (Uext - U0) /
Imax
Uext
Passive
32 VDC
Active
Modular I/Os
NAMUR
15
TECHNICAL DATA 2
Operating data
OPTISONIC 7300
16
NAMUR
www.krohne.com
U I = 30 V
I I = 100 mA
PI = 1 W
CI = 10 nF
LI = 0 mH
0.5 mA
4mA
6 mA at U ext = 24 V
6.6 mA at Uext = 32 V
On:
U 0 5.5 V or I
Off:
U 0 3.5 V or I
I
I
U ext
Contact open:
U0, nom = 8.7 V
Active to
EN 60947-5-6
Imax = 9.5 mA at
Uext 32 V
Imax = 8.2 mA at
Uext 32 VDC
Imax = 9.5 mA at
Uext 24 V
32 VDC
Imax = 6.5 mA at
Uext 24 VDC
Uext
Off:
U0 10 V with
Inom = 1.9 mA
On:
U0 12 V with
Inom = 1.9 mA
Terminals bridged:
Inom = 4 mA
Terminals open:
U0, nom = 22 V
Uint = 24 VDC
32 VDC
Uext
Passive
32 VDC
Active
Ex-i
Basic I/Os
Operating data
Modular I/Os
Set value of the outputs to "zero", counter and error reset, range change.
OPTISONIC 7300
Function
Control input
2 TECHNICAL DATA
0...9.999 m/s; 0...19.0%, settable in 0.1% steps, separately for each current
and pulse output.
Off
Time setting
www.krohne.com
Passive
Active
22 mA
No HART
U0, max = 5 V at
I 22 mA
Imax 26 mA
(electronically limited)
32 VDC
22 mA
32 VDC
No HART
U I = 30 V
I I = 100 mA
PI = 1 W
CI = 10 nF
LI =0 mH
No HART
U 0, max = 4 V at I
U ext
17
22 mA
U 0 = 24.1 V
I 0 = 99 mA
P0 = 0.6 W
C0 = 75 nF / L0 = 0.5 mH
No HART
Uext
No HART
U0, min = 19 V at
I 22 mA
No HART
U 0, min = 14 V at
I 22 mA
Imax 26 mA
(electronically limited)
22 mA
22 mA
U int = 20 VDC
Uint = 24 VDC
Ex i
Basic I/Os
Operating data
Modular I/Os
Function
Current input
Can be set together for all flow indicators and outputs, or separately for:
current, pulse and frequency output, limit switches and the 3 internal
counters.
Function
Time constant
0...9.999 m/s; 0...20.0%, settable in 0.1% steps, separately for each current
and pulse output.
TECHNICAL DATA 2
On
Low-flow cutoff
OPTISONIC 7300
18
Volume flow, corr. volume flow, mass flow, molar mass, enthalpy flow,
spec. enthalpy, density, flow speed, process temperature, process pressure,
electronic temperature, velocity of sound (av.), gain (av.), SNR (av.),
velocity of sound 1-3, gain 1-3, SNR 1-3
Output data
Transmission procedure
Address range
Supported function
codes
Broadcast
Supported Baudrate
Production module H
Fluid group 1
Directive: 97/23/EC
Directive: 2006/95/EC
Signal converter
IEC 68-2-64
Vibration resistance
www.krohne.com
IEC 68-2-27
Shock resistance
IP67 (NEMA 6)
Standard
ATEX
Hazardous areas
Non-Ex
Pressure Equipment
Directive
Electromagnetic
compatibility
CE
Description
MODBUS
OPTISONIC 7300
Function blocks
Discription
FOUNDATION Fieldbus
2 TECHNICAL DATA
www.krohne.com
Compact version
Remote version
OPTISONIC 7300
Total height = H + a
c = 260 mm / 10.2"
b = 230 mm / 9.1" 1
a = 155 mm / 6.1"
Total height = H + a
c = 106 mm / 4.2"
b = 139 mm / 5.5" 1
a = 77 mm / 3.1"
19
TECHNICAL DATA 2
20
PN 10
PN 10
PN 10
PN 10
PN 10
PN 10
PN 10
PN 10
200
250
300
350
400
450
500
600
PN [Bar]
790
670
620
640
610
580
530
460
784
678
625
575
519
473
423
368
Dimensions [mm]
PN 16
PN 16
PN 16
100
125
150
PN [Bar]
540
520
490
315
283
254
Dimensions [mm]
387
359
337
PN 40
PN 40
PN 40
50
65
80
PN [Bar]
480
350
320
230
216
196
Dimensions [mm]
324
313
300
www.krohne.com
82.5
70.3
54.5
Di 1
159
133
107
19
14
11
Approx
weight
[kg]
35
32
24
Approx
weight
[kg]
278
202
170
141
109
81
66
46
DN
Nominal size
Di 1
593
780
442
392
341
310
261
207
493
DN
Nominal size
Di 1
Approx
weight
[kg]
OPTISONIC 7300
670
623
583
542
517
474
429
DN
Nominal size
EN 1092-1
2 TECHNICAL DATA
15.0
20.5
21.7
23.2
24.4
21.2
24.0
26.4
28.7
30.3
30.7
32.7
35.8
2"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
24"
910
830
780
770
730
670
610
540
620
590
550
520
380
360
[mm]
31.5
27.3
25.0
23.3
21.0
19.4
16.9
14.5
12.2
11.2
10.1
8.9
8.3
7.5
[inch]
801
693
635
591
534
492
428
369
312
285
258
226
210
190
[mm]
32.0
27.5
25.0
23.5
21.3
20.4
18.7
16.9
15.2
14.1
13.3
12.8
12.2
11.8
[inch]
Dimensions
W
813
699
635
597
540
512
474
429
387
364
337
324
310
300
[mm]
15.4
21.3
22.4
24.0
25.2
22.0
25.2
28.0
29.9
31.9
33.1
36.6
38.2
2"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
24"
970
930
840
810
760
710
640
560
640
610
570
540
390
380
[mm]
33.5
28.8
26.5
24.3
22.0
20.1
17.6
15.3
13.0
11.7
10.7
9.3
8.5
7.7
[inch]
851
731
673
616
559
511
448
388
331
298
271
235
217
196
[mm]
36.0
30.5
28.0
25.5
23.0
20.5
18.3
16.6
15.0
14.1
13.3
12.8
12.2
11.8
[inch]
914
775
711
648
584
521
474
429
387
364
337
324
310
300
[mm]
Dimensions [inches]
22.6
18.8
16.9
15.0
13.1
11.9
10.0
8.0
6.1
5.1
4.0
3.1
2.5
2.1
[inch]
www.krohne.com
15.0
[inch]
2"
Nominal
size
ASME 300 lb
575
478
428
381
333
303
255
203
154
128
102
78
63
53
[mm]
591
489
441
391
340
311
260
206
154
128
102
78
63
53
[mm]
Di 1
23.3
19.3
17.5
15.4
13.4
12.2
10.3
8.1
6.1
5.1
4.0
3.1
2.5
2.1
[inch]
Di 1
1715
1237
926
785
609
452
309
207
146
115
86
53
38
27
[lb]
21
778
561
420
356
276
205
140
94
66
52
39
24
17
12
[kg]
411
304
259
210
160
121
84
59
41
38
29
20
15
10
[kg]
Approx
weight
904
607
570
462
352
266
185
130
90
84
64
44
33
22
[lb]
Approx
weight
TECHNICAL DATA 2
14.2
[inch]
2"
Nominal
size
ASME 150 lb
OPTISONIC 7300
22
16.1
22.0
24.4
26.0
27.2
24.4
27.2
28.3
29.9
32.7
34.6
35.4
38.2
2"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
24"
970
900
880
830
760
720
690
620
690
660
620
560
410
400
[mm]
34.0
29.5
27.1
25.0
22.4
20.9
18.3
16.1
13.8
12.7
11.1
9.3
8.5
7.7
[inch]
864
750
689
635
568
530
479
408
350
323
281
235
217
196
[mm]
37.0
32.0
29.3
27.0
23.7
22.0
20.0
16.5
15.0
14.1
13.1
12.5
12.0
11.5
[inch]
640
813
743
686
603
559
508
421
374
359
337
324
310
300
[mm]
Dimensions [inches]
18.1
23.6
26.8
26.8
28.7
26.8
29.9
31.9
33.9
2"
3"
4"
5"
6"
8"
10"
12"
14"
860
810
760
680
730
680
640
600
460
450
[mm]
23.1
21.9
19.6
17.0
14.3
12.6
11.4
9.9
9.6
8.7
[inch]
588
556
498
433
363
333
290
251
244
222
[mm]
25.2
24.0
21.5
18.5
15.0
13.7
13.0
12.5
12.0
11.5
[inch]
641
610
546
470
381
359
337
324
310
300
[mm]
Dimensions [inches]
11.8
10.7
9.1
7.2
5.5
4.6
3.4
2.6
2.3
1.7
[inch]
www.krohne.com
300
273
230
183
140
116
87
67
59
43
[mm]
548
456
409
364
317
289
243
194
146
122
97
74
59
49
1106
1382
1168
838
545
335
240
157
119
86
64
[lb]
769
630
501
362
297
241
151
101
83
54
30
20
15
[kg]
627
530
380
247
152
109
71
54
39
29
[kg]
Approx
weight
2438
1695
1389
1105
798
655
531
333
223
183
119
66
44
33
[lb]
Approx
weight
OPTISONIC 7300
17.7
[inch]
2"
Nominal
size
ASME 900 lb
Di 1
21.6
17.9
16.1
14.3
12.5
11.4
9.6
7.6
5.8
4.8
3.8
2.9
2.3
1.9
[mm]
Di 1
[inch]
15.7
[inch]
2"
Nominal
size
ASME 600 lb
2 TECHNICAL DATA
202
b
120
120
c
155
155
7.75
7.75
F
a
C
Version
4.75
4.75
260
www.krohne.com
6.10
6.10
10.20
137
5.40
Dimensions [inches]
Dimensions [mm]
202
F
a
C
Version
OPTISONIC 7300
11.60
295.8
277
10.90
23
12.60
9.30
Weight
[lb]
5.7
4.2
Weight
[kg]
TECHNICAL DATA 2
24
[inches]
0.4
3.9
2.4
OPTISONIC 7300
100
www.krohne.com
60
[mm]
a
2 TECHNICAL DATA
INSTALLATION 3
www.krohne.com
For exchanging the transducers, please keep a free space of 1 m / 39" around the transducer.
25
The OPTISONIC 7300 is designed for the measurement dry gasflow. Excess of liquids may
disturb the acoustic signals and should thus be avoided.
The following guidelines should be observed in case occasional small amounts of liquids are to
be expected:
To secure the optimum functioning of the flowmeter, please note the following observations.
Allow 1020 cm / 3.97.9" of space at the sides and rear of the signal converter to permit
free air circulation.
Protect signal converter against direct solar radiation, install a sunshield if necessary.
Signal converters installed in switchgear cabinets require adequate cooling, e.g. by fan or
heat exchanger.
Do not expose the signal converter to intense vibration.
The overall functionality of the OPTISONIC 7300 gas flowmeter is the continuous measurement
of actual volume flow, mass flow, molar mass, flow speed, velocity of sound, gain, SNR and
diagnosis value.
OPTISONIC 7300
20 DN
3 DN
10 DN
3 DN
26
DN100/4"
DN80/3"
www.krohne.com
1
2
2 path flowmeter
1
2
1 path flowmeter
3 INSTALLATION
OPTISONIC 7300
10 DN
www.krohne.com
27
INSTALLATION 3
To avoid distorted flow profiles and interference caused by valve noise in the sensor, control
valves or pressure reducers should not be installed in the same pipeline as the flowmeter. In
case this is required, please contact the manufacturer.
3.4.5 Vibration
3.4.4 T-section
1 Lmax
2 Lmin
OPTISONIC 7300
28
1 Vent holes
3.4.7 Insulation
3 INSTALLATION
www.krohne.com
OPTISONIC 7300
1
2
3
4
5
www.krohne.com
29
ELECTRICAL CONNECTIONS 4
The flow sensor is connected to the signal converter via the signal cable(s). A flow sensor with
one acoustic path, 1 cable is required. A flow sensor with two acoustic paths, 2 cables are
required.
OPTISONIC 7300
30
OPTISONIC 7300
www.krohne.com
24 VAC/DC
Connect the protective ground conductor PE of the mains power supply to the separate
terminal in the terminal compartment of the signal converter.
Connect the live conductor to the L terminal and the neutral conductor to the N terminal.
100230 VAC
4 ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS 4
www.krohne.com
31
For hazardous areas, all of the input/output variants for the housing designs with terminal
compartment in the Ex d (pressure-resistant casing) or Ex e (increased safety) versions can
be delivered.
Please refer to the separate instructions for connection and operation of the Ex-devices.
Ex option
The device allows intrinsically safe and non intrinsically safe bus interfaces in combination
with additional modules.
For connection and operation of bus systems, please note the separate documentation.
Bus systems
Depending on the task, the device can be configured with various output modules.
Modular version
Depending on the task, the device can be configured with various output modules.
Current outputs can be active or passive.
Optionally available also with Foundation Fieldbus and Profibus PA
Ex i version
Has 1 current output, 1 pulse output and 2 status outputs / limit switches.
The pulse output can be set as status output/limit switch and one of the status outputs as a
control input.
Basic version
OPTISONIC 7300
ID number: 6
ID number: 0 = standard
Power supply option
Display (language versions)
Input/output version (I/O)
1st optional module for connection terminal A
2nd optional module for connection terminal B
OPTISONIC 7300
100...230 VAC & standard display; modular I/O: I a & PN/SN and optional module PN/SN & CN
24 VDC & standard display; modular I/O: Ia & Pa/Sa and optional module P p/Sp & Ip
CG 360 11 7FK
CG 360 81 4EB
A
B
C
E
F
G
K
H
P
R
8
0
Ia
Ip
P a / Sa
P p / Sp
P N / SN
Ca
Cp
CN
IIna
IInp
-
32
Abbreviation
www.krohne.com
Passive pulse output, frequency output, status output or limit switch acc.
to NAMUR (changeable)
Description
100...230 VAC & standard display; basic I/O: I a or Ip & Sp/Cp & Sp & Pp/S p
CG 360 11 100
The last 3 digits of the CG number (5, 6 and 7) indicate the assignment of the terminal
connections. Please see the following examples.
1
2
3
4
5
6
7
Figure 4-2: Marking (CG number) of the electronics module and input/output variants
4 ELECTRICAL CONNECTIONS
A+
Connection terminals
A-
Ia + HART active 1
Ip + HART passive 1
Ip passive
Ip passive
220
320
Ia active
310
www.krohne.com
PN / SN NAMUR
Cp passive 2
PN / SN NAMUR
Cp passive 2
I p + HART passive
I a + HART active
I p + HART passive
I a + HART active
Ia active
210
PN / SN NAMUR
Cp passive 2
I p + HART passive
C-
300
Sp passive
I a + HART active
PN / SN NAMUR
Cp passive 2
Sp / Cp passive 2
B-
200
100
D-
PN / SN NAMUR 2
PN / SN NAMUR 2
PN / SN NAMUR 2
PN / SN NAMUR 2
PN / SN NAMUR 2
PN / SN NAMUR 2
Pp / Sp passive 2
The grey boxes in the tables denote unassigned or unused connection terminals.
In the table, only the final digits of the CG no. are depicted.
Connection terminal A+ is only operable in the basic input/output version.
CG-No.
33
ELECTRICAL CONNECTIONS 4
OPTISONIC 7300
A+
Connection terminals
6__
B__
7__
C__
34
www.krohne.com
H__ 3
1 Changeable
2 Not activated bus terminator
3 Activated bus terminator
G__ 2
Modbus (Option)
B-
8__
A-
4__
CG
no.
C-
Sign. B
(D1)
Sign. B
(D1)
Sign. A
(D0)
Sign. A
(D0)
PN / SN NAMUR 1
PN / SN NAMUR 1
Pp / Sp passive 1
Pp / Sp passive 1
Pa / Sa active 1
Pa / Sa active 1
Common
Common
I p + HART passive
I a + HART active
I p + HART passive
I a + HART active
I p + HART passive
I a + HART active
D-
OPTISONIC 7300
The grey boxes in the tables denote unassigned or unused connection terminals.
In the table, only the final digits of the CG no. are depicted.
Term. = (connection) terminal
4 ELECTRICAL CONNECTIONS
Maximum:
Minimum:
Normal:
Pressure
Maximum:
Minimum:
Normal:
Temperature
Maximum:
Minimum:
Normal:
Flowrate
Velocity of sound:
Density:
H2 content:
CO2 content:
Gas composition:
Medium
Measurement objective:
New application
Existing application, currently using:
www.krohne.com
E-mail:
Fax:
Telephone:
Address:
Company:
Submitted by:
Date:
Customer information:
35
APPLICATION FORM 5
Please fill in this form and fax or email it to your local representive. Please include a sketch of
the pipe layout as well, including the X, Y, Z dimensions.
OPTISONIC 7300
36
Accessories:
Options:
Digital protocol:
Accuracy requested
(percentage of rate):
Hardware requirements:
Additional details:
Hazardous area:
Nuclear (radiation):
Sea water:
Corrosive atmosphere:
Environment details
www.krohne.com
Upstream situation
(elbows, valves, pumps):
Liner thickness:
Liner material:
Pipe material:
Outer diameter:
Piping details
5 APPLICATION FORM
OPTISONIC 7300
OPTISONIC 7300
www.krohne.com
37
NOTES 6
38
6 NOTES
www.krohne.com
OPTISONIC 7300
OPTISONIC 7300
www.krohne.com
39
NOTES 6
KROHNE 02/2012 - 4001344702 - TD OPTISONIC 7300 R02 en - Subject to change without notice.
Analysis products
Pressure meters
Temperature meters
Level meters
Flow controllers
Vortex flowmeters
Mass flowmeters
Ultrasonic flowmeters
Electromagnetic flowmeters
The current list of all KROHNE contacts and addresses can be found at: