Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

FPI 20.

3P
Output Power Rating
rpm
1500
1800

Prime

Frequency
50 Hz
60 Hz

Voltage
400
480

Kva
20.3
24.2

Standby***
Kw
16.2
19.3

Kva
22.3
26.6

Kw
17.8
21.3

Switch able speed 1500/1800 rpm


The above kW rating are at 0.8 pf
Guarantied within condition equivalent to those specification in ISO 8528-1,ISO 3046-1 and BS 5514-1.
* Prime power rating of the generating set is where a varible load and unlimited hours usage are applied
on the generating set with an average load factor of 80% of the prime rating over each 24 hours period.
Nothing that a 10% overload is availble for 1 hour in every 12 hours operation
** Standby power rating of the generating set is where a varible load limited to an annual usage up to 500
hours is applied, with 300 hours of which may be continous running. Noting that no overload is permitted

Engine Technical Data


Engine Make and Model
Cylinder
Aspiration
Combustion System
Displacement
Governor
Emissions Regulation
Electrical Starting System

Perkins 404D-22G
4 Vertical In-Line
Naturally Aspirated
Indirect Injection
2.216 Liters
Mechanical
EU stage IIIA & US EPA Tier 4
12 Volt Starter Motor and 12 Volt 15 Amp Alternator DC Output

Air System
Air Filter Type
Combustion Air
Flow
Cm/min(cfm)

Prime

Standby
Max Air Filter Intake Restriction

Split Element (Replaceable)


50 Hz
1.45 (51.20)
1.45 (51.20)
6.4 kpa

60 Hz
1.74 (61.44)
1.74 (61.44)
6.4 kpa

Fuel System
Fuel Filter Type
Recommended Fuel
Engine Speed
Standby
Fuel Consumption
Prime Power
l/hr(US gal/hr)
75% of Prime Power
50% of Prime Power
Fuel Tank: Open / Close

Split Element (Replaceable)


Class A2 Diesel
1500 rpm
6.1 (1.61)
5.3 (1.40)
4.0 (1.06)
2.9 (0.77)
97 L / 114 L

1800 rpm
6.9 (1.82)
6.2 (1.64)
4.8 (1.27)
3.5 (0.92)

Lubrication System
API-CH-4 or ACEA E5 SAE 15W40 (-10OC to 50OC Ambient Temperature)
10.6 L
8.9 L
Spin-On Full Flow
N/A

Lube Oil
Lube Oil Capacity
Oil Pan
Oil Filter Type
Oil Cooling Method

Cooling System
Coolant Capacity
Cooling System
Cooling Fan Air Flow m3/min (cfm)
Heat Radiation to
Room

Prime
Standby

7.0 L
Mounted Radiator, Water Cooled
40.2 (1419.65)
52.2 (1843.42)
50 Hz
60 Hz
3.3 kW
3.8 kW
4.4 kW
4.6 kW

Exhaust system
Grade
Size
QTY
Exhaust gas flow
Prime
m3/min (cfm)
Standby
Max Allowable Backpressure
Silencer

Exhaust Gas Max


Temperature

Prime
Standby

Industrial
2"
1
3.64 (128.54)
3.94 (139.13)
10.2 kpa
50 Hz
445OC
505OC

4.34 (153.26)
4.76 (168.09)
10.2 kpa
60 Hz
440OC
510OC

FPI 20.3P
Alternator Technical Data

Stamdford / or L.S

Model Number
No. of Poles
Number of terminals (leads)
A.V.R & Excitation
Regulation
Ingress Protection
Insulation Class
TIF
THD at Full Load %
THD at No Load %
Cooling Air flow-@50 Hz m3 / min (cfm)
Cooling Air flow-@60 Hz m3 / min (cfm)

BC1164E
4
12
SX 460
1%
IP-23
H
<45
2/2
3.7 / 3.7
5.3 (187.16)
45.8 (204.82)

Output Voltage

50 Hz

V
kVA
kW

60 Hz

380
17
13.6

400
17
13.6

415
17
13.6

440
15.5
12.4

415
17.5
14

440
18.6
14.9

460
20.4
16.3

480
20.4
16.3

217.2
18.73
12.74

196
16.9
11.5

182.7
15.70
10.68

182.1
15.70
10.68

224.9
19.38
13.2

212.7
18.34
12.48

213.4
18.34
12.48

196
16.9
11.5

32.5

42.5

51.0

26

35

35

52.5

Alternator performance data


Reactance (f.l.cl.f)

xd %
xd' %
xd'' %

Motor starting capacity based on 30%


voltage dip and 0.8 pf (kVA)

Controller features

DSE

Controller Make and Model

Auto mains failure (AMF) applications including remote communication,


user configuration and complete gen-set monitoring and protection.
Ready for generators with 3 ph 4 wire / 3ph 3 wire/ Mono ph

Engine Protection

Generator Protection

Inputs and Outputs

Event and Performance Log

* Oil Pressure
* Coolant Temperature
* Over / Under Voltage
* Over / Under Frequency
* Phases Frequency
* 3 No's Configurable Analog Inputs
* 4 No's Binary Inputs
* Gen-set text Alarm Log
* For More Features we can use
High Controller

* Fuel Level (Optional)


* Over Current
* Charging Alternator Fault
* 6 No's Binary Outputs
* D+ Pre-Excitation Terminal
* Engine Hours History Log

Gen-set Enclosure specification (optional)


Enclosure Type
Anticorrosive Protection
Access Doors
Drainage
Transportation
Noise Level (@ Free-Field Conditions)
Water Fill
Cable Access
Emergency stop
Canopy RAL Color
Chassis RAL Color

Acoustic and Weatherproof


Polyester Powder Coated Galvanized Sheet
4
Fuel and Water Drainage Provision
Tested Single Point Lifting Facility & Forklift Pockets
66 dBA @ 7 meter
Radiator Water Filling Provision
Cable Inlet and Outlet Provision
External Emergency Push Button
RAL 2000
RAL 9011

Shipping Data
Type
Open
Enclosed

Length (mm)
1624
2212

Width (mm)
750
912

Height (mm)
1220
1402

Notes:
All Generators carry a one year or (1,000) hour's manufacturer's warranty
In line with our policy of continuous, FPI reserves the right to change specification without notice.

Weight (kg)
488
786