AUDIT CRITERIA
161Thorn Hill Road
Warrendale, PA 15086-7527
Issued 1997-07
Revised 2015-04
Superseding AC7114/1 Rev G
1.
SCOPE
These Audit Criteria define the requirements for suppliers seeking
Nadcap accreditation in Penetrant and are to be used as supplement to
PRI AC7114. These criteria and the applicable User Prime
Supplemental Checklists will ensure that NDT suppliers meet the
requirements for Nadcap accreditation in Penetrant.
2.
GENERAL INFORMATION
In completing this assessment, auditors are instructed to respond with
a "Yes or No" to address compliance with each statement of
requirement. For any negative responses, the auditor must clearly
indicate in the NCR if the No" reflects noncompliance with respect to
existence, adequacy, and/or compliance. Existence relates to evidence
of a documented procedure or policy, adequacy relates to the
completeness of the procedure or policy, and compliance relates to
evidence of effective implementation. This checklist includes the use of
the word shall which indicates a clear requirement that must be met
at all times. The word, may indicates a possible resolution to a
requirement or one recommended method to achieve a given
requirement, but does not represent the only way to meet that
requirement. In addition the checklist includes the term Compliance
Assessment Guidance. This term is used to reflect the Task Groups
expectation when answering the checklist question as YES or NA.
The auditor must verify the list of procedures provided by the supplier
at the time of the audit. Any corrections or updates to the list must be
identified using notes inserted at the applicable criterion.
PRI operating procedures provide that "This report is published by PRI to advance the state of technical, engineering, and quality
sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, includi ng any patent
infringement arising there from, is the sole responsibility of the user."
PRI values your input. To provide feedback on this document, please contact the appropriate commodity staff engineer.
(Contact information is located at http://www.eauditnet.com under Contact Us.)
Copyright 2015 Performance Review Institute. All rights reserved.
t-frm-15
19-Apr-2015
PRI
AC7114/1 Rev. H
All negative responses require a Nonconformance Report (NCR). Not
Applicable (NA) responses do not require an explanation unless
otherwise noted. There is only one plausible reason for an NA, which
is, that a particular operation or issue is not being used at the supplier.
There are no NAs simply for a lack of a customer requirement. If a
system is in use, then all questions pertaining to that system are
applicable. If verification of results require documentation it shall be so
noted in this checklist.
The audit results shall not include any customer proprietary
information. Technical information on parts which have been
designated Export Controlled License Required (EC-LR) cannot be
input into eAuditNet. If auditors have any questions about this, they
should contact the Staff Engineer for directions.
GO FORWARD PLAN Any new or revised procedure made after 4
December 2006 requires compliance to the following requirements.
Procedures written prior to this date shall be acceptable; however a
system needs to be in place to ensure that changes reflect the current
Nadcap requirements.
2.1
References:
SAE Publications: Available from SAE, 400 Commonwealth Drive,
Warrendale, PA 15086-0001
AMS 2644
QPL-SAE-AMS-2644
3.
ASTM-E-1417
ASTM-E-1135
ASTM-D 95
-2-
PRI
3.1
AC7114/1 Rev. H
-3-
3.2
Material Certification
3.2.1
ATTACHMENT
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Material Identification
3.3.1
3.4
Equipment Arrangement
3.4.1
4.
PROCEDURES
4.1
4.1.1
4.2
Approval
4.2.1
4.3
Procedure / Technique
Does the written procedure, general or specific, contain the following
information as a minimum?
Compliance Assessment Guidance:
The term, procedure may be synonymous with a traveler or a route
card, etc. All non-technical requirements that have been flowed down
PRI
AC7114/1 Rev. H
-4-
YES
NO
YES
NO
4.3.3
YES
NO
4.3.4
YES
NO
4.3.5
YES
NO
4.3.5.1
YES
NO
4.3.5.2
YES
NO
NA
YES
NO
4.3.7
YES
NO
NA
YES
NO
4.3.9
YES
NO
4.3.10
YES
NO
4.3.11
YES
NO
NA
PRI
AC7114/1 Rev. H
-5-
YES
NO
4.3.13
YES
NO
YES
NO
NA
All required process control tests and checks called out in section 5 of
this checklist?
5.
The following tests marked re-used are required when, and if, the
materials are used from a tank, container or are sprayed and
recovered. If materials are not recovered in any way, tests marked
as re-used are not applicable and shall be noted as such.
5.1
SECTION NA
5.1.1
YES
NO
5.1.2
YES
NO
5.1.3
YES
NO
5.1.4
Are records of this test on file and do they indicate acceptable results?
YES
NO
PRI
AC7114/1 Rev. H
-6-
SECTION NA
5.2.1
YES
NO
5.2.2
YES
NO
5.2.3
YES
NO
5.2.4
Are records of this test on file and do they indicate acceptable results?
YES
NO
SECTION NA
5.3.1
YES
NO
5.3.2
YES
NO
5.3.3
YES
NO
YES
NO
Are records of this test on file and do they indicate acceptable results?
Compliance Assessment Guidance: The test results may indicate the
exact percentage or simply state acceptable or some other term that
denotes acceptance.
5.4
SECTION NA
5.4.1
YES
NO
5.4.2
YES
NO
5.4.3
YES
NO
5.4.4
Are records of this test on file and do they indicate acceptable results?
YES
NO
SECTION NA
PRI
AC7114/1 Rev. H
5.5.1
5.5.1.1
-7-
SECTION NA
YES
NO
YES
NO
5.5.1.3
YES
NO
5.5.1.4
YES
NO
YES
NO
5.5.1.6
YES
NO
5.5.1.7
Are records of this test on file and do they indicate acceptable results?
YES
NO
YES
NO
PRI
AC7114/1 Rev. H
-8-
5.5.2
SECTION NA
5.5.2.1
YES
NO
5.5.2.2
YES
NO
5.5.2.3
YES
NO
5.5.2.4
YES
NO
YES
NO
5.5.2.6
Are records of this test on file and do they indicate acceptable results?
YES
NO
YES
NO
5.6
5.6.1
SECTION NA
YES
NO
YES
NO
Does the check for recycled dry developer ensure the developer has
not picked up excessive fluorescent material (10 or more fluorescent
specks observed in a 4 inch/10cm circle), when tested utilizing the
same method used for applying developer to hardware?
NA
PRI
AC7114/1 Rev. H
-9-
Does the check ensure that the developer is not caked? (applicable to
recycled and closed systems)
YES
NO
5.6.4
Are records of this test on file and do they indicate acceptable results?
YES
NO
YES
NO
5.7
5.7.1
YES
NO
5.7.2
Is a hydrometer and a specific gravity chart being used for this test?
YES
NO
5.7.3
YES
NO
5.7.4
Are records of this test on file and do they indicate acceptable results?
YES
NO
YES
NO
SECTION NA
5.8
5.8.1
YES
NO
5.8.2
YES
NO
5.8.3
YES
NO
5.8.4
Are records of this test on file and do they indicate acceptable results?
YES
NO
SECTION NA
PRI
AC7114/1 Rev. H
- 10 -
YES
NO
5.8.6
YES
NO
5.9
5.9.1
YES
NO
YES
NO
YES
NO
5.9.3
Are records of this test on file and do they indicate acceptable results?
Compliance Assessment Guidance: Results of the system performance
NA
PRI
AC7114/1 Rev. H
- 11 -
test, utilizing the in-use materials, must indicate the same number and
appearance (e.g. size, etc.) of the flaws detected originally when the
baseline was established. Example: If 4 stars of a certain size and
appearance are originally detected, then the same number and
appearance of the stars is expected each subsequent test and the
actual number must be recorded. This comparison shall be made
utilizing a color photograph (approximately 1:1, whose back ground
does not interfere with the comparison) or by direct comparison of used
versus unused materials.
5.9.4
YES
NO
YES
NO
YES
NO
YES
NO
5.10
5.10.1
5.10.2
NA
PRI
AC7114/1 Rev. H
5.10.3
Is the stated tolerance for the degradation check +/- 30% of the
baseline measurement?
5.11
5.11.1
- 12 -
YES
NO
NA
SECTION NA
YES
NO
YES
NO
5.12
Dryer Controls
5.12.1
SECTION NA
YES
NO
YES
NO
YES
NO
5.12.3
PRI
AC7114/1 Rev. H
- 13 -
YES
NO
5.12.5
YES
NO
5.12.6
YES
NO
YES
NO
YES
NO
5.12.8
5.13
5.13.1
YES
NO
5.13.2
YES
NO
5.13.3
YES
NO
YES
NO
PRI
AC7114/1 Rev. H
- 14 -
YES
NO
5.13.6
YES
NO
YES
NO
5.13.8
YES
NO
YES
NO
YES
NO
5.13.10
5.13.11
Are the black light reflectors and filters clean and in good condition?
YES
NO
5.13.12
Where battery powered lamps are used does the procedure address
consistency of U/V output and the controls used to ensure adequate
output during all inspection activity?
YES
NO
5.14.1
YES
NO
5.14.2
YES
NO
NA
PRI
5.14.3
AC7114/1 Rev. H
- 15 -
YES
NO
YES
NO
5.14.5
YES
NO
YES
NO
Is ambient white light level in the inspection area, controlled for Type I
penetrant, not to exceed 2 ft candles (20 lux) as measured at the
examination surface?
Compliance Assessment Guidance: This measurement is taken in the
darkened inspection area to include the examination surface with the
black lights operating in the fixed position of 15 inches (38 cm).
5.14.7
Is this check being performed at least weekly, prior to use and after
equipment maintenance?
YES
NO
5.14.8
YES
NO
YES
NO
5.14.10
YES
NO
NA
YES
NO
NA
YES
NO
NA
YES
NO
5.14.12
5.15
Timing Devices
5.15.1
Are timing devices that are used to monitor penetrant, emulsifier and
developer dwell times calibrated at a minimum of one point at least
PRI
AC7114/1 Rev. H
- 16 -
5.16.1
YES
NO
NA
YES
NO
NA
YES
NO
NA
Pressure Monitors
5.17.1
5.17.2
6.
COMPLIANCE
Compliance Assessment Guidance: The supplier shall perform
representative inspections from current production to determine
compliance with these requirements. These parts shall be selected to
represent a variety of Nadcap participating customer requirements and
several different types of processing equipment if more than one
penetrant line is in use at this facility. Borrowing hardware from one
company to another to demonstrate compliance is not acceptable;
unless there is objective evidence the design authority has authorized
movement of the hardware to the company undergoing the audit.
Investigate the purchase order specifications to identify any customer
unique acceptance, process control, or procedure requirements
applicable to these parts. Witness the facilitys ability to perform
inspection of these parts in accordance with the requirements.
It is expected that the auditor shall review and follow traceability from
the purchase order to completion of the NDT process or final
certification by reviewing as a minimum the items listed below. The
auditor shall verify that the process applied complies with the
procedural system established by the company in terms of flow down,
customer specification retrieval (as applicable), inspection
PRI
AC7114/1 Rev. H
- 17 -
identification, etc.
a) Purchase Order
b) Drawing (if applicable)
c) Work Order
d) Process Specifications and Revision
e) Internal Procedures and Revision
f) Lot / Batch / Serial Number:
g) Applicable Procedures / Techniques / Work Instructions
h) Travelers / Route Cards
i) Inspection Log
6.1
Provide the following documentation for auditor review for each of the
parts being tested during the compliance portion of the audit: Note: ECLR materials shall not leave the suppliers facility.
a.Copy of completed technique card or supplier procedure with
evidence of customer approval if required.
b.Copy of the applicable shop traveler or work order.
c.If neither a or b above indicate the process and acceptance standard
and their revision status, then the document that shows the link to this
data shall also be reviewed.
A.
Compliance
Customer
End User
Process Specification(s):
Revision(s)
Internal Procedure(s):
Revision(s)
YES
NO
NA
PRI
AC7114/1 Rev. H
Revision(s)
- 18 -
Part Description:
Part Number:
Penetrant Type:
Revision
Method:
Sensitivity Level:
Developer Form:
Inspectors
B.
Level(s):
Compliance
Customer
End User
Process Specification(s):
Revision(s)
YES
NO
NA
PRI
AC7114/1 Rev. H
Internal Procedure(s):
- 19 -
Revision(s)
Revision(s)
Part Description:
Part Number:
Penetrant Type:
Revision
Method:
Sensitivity Level:
Developer Form:
Inspectors
C.
Level(s):
Compliance
Customer
End User
YES
NO
NA
PRI
AC7114/1 Rev. H
- 20 -
Process Specification(s):
Revision(s)
Internal Procedure(s):
Revision(s)
Revision(s)
Part Description:
Part Number:
Penetrant Type:
Revision
Method:
Sensitivity Level:
Developer Form:
Inspectors
Level(s):
PRI
6.2
AC7114/1 Rev. H
- 21 -
NA
Compliance
Customer
YES
NO
End User
Process Specification(s):
Revision(s)
Internal Procedure(s):
Revision(s)
Revision(s)
PRI
AC7114/1 Rev. H
- 22 -
Part Description:
Part Number:
Penetrant Type:
Revision
Method:
Sensitivity Level:
Developer Form:
Inspectors
B.
Level(s):
Date Performed:
Compliance
Customer
End User
Process Specification(s):
Revision(s)
Internal Procedure(s):
Revision(s)
YES
NO
NA
PRI
AC7114/1 Rev. H
Acceptance Specification(s) / Drawing Notes:
- 23 -
Revision(s)
Part Description:
Part Number:
Penetrant Type:
Revision
Method:
Sensitivity Level:
Developer Form:
Inspectors
C.
Level(s):
Date Performed:
Compliance
Customer
End User
Process Specification(s):
Revision(s)
YES
NO
NA
PRI
AC7114/1 Rev. H
- 24 -
Internal Procedure(s):
Revision(s)
Revision(s)
Part Description:
Part Number:
Penetrant Type:
Revision
Method:
Sensitivity Level:
Developer Form:
Inspectors
Level(s):
Date Performed:
PRI
6.3
AC7114/1 Rev. H
- 25 -
Customer Specifications
Compliance Assessment Guidance: The auditor shall verify compliance
to each of these requirements by direct observation.
6.3.1
YES
NO
YES
NO
YES
NO
YES
NO
NA
NA
NA
6.3.4
6.3.5
YES
NO
6.3.6
YES
NO
6.3.7
YES
NO
Inspection Process
Compliance Assessment Guidance: The auditor shall verify compliance
NA
PRI
AC7114/1 Rev. H
- 26 -
6.4.1.1
YES
NO
6.4.1.2
Specification reference?
YES
NO
6.4.1.3
YES
NO
6.4.1.4
YES
NO
6.5
Pre-Cleaning
YES
NO
YES
NO
6.5.2
6.6
Pre-Penetrant Etching
SECTION NA
YES
NO
6.6.2
YES
NO
NA
YES
NO
NA
YES
NO
NA
6.6.4
PRI
AC7114/1 Rev. H
- 27 -
Penetrant Application
Compliance Assessment Guidance: The auditor shall verify compliance
to each of these requirements by direct observation.
6.7.1
YES
NO
YES
NO
6.7.3
YES
NO
YES
NO
YES
NO
6.7.5
6.7.6
YES
NO
6.7.7
YES
NO
6.7.8
YES
NO
6.8
Use of Emulsifier
SECTION NA
NA
YES
NO
PRI
6.8.2
AC7114/1 Rev. H
- 28 -
YES
NO
YES
NO
6.8.4
YES
NO
YES
NO
NA
Was the entire part flooded with water prior to reaching the maximum
emulsification time?
6.9
Penetrant Removal
Compliance Assessment Guidance: The auditor shall verify compliance
to each of these requirements by direct observation. Some questions
will be NA if only method C is utilized.
6.9.1
YES
NO
NA
6.9.2
YES
NO
NA
6.9.3
YES
NO
NA
6.9.4
YES
NO
NA
YES
NO
NA
YES
NO
6.9.6
PRI
AC7114/1 Rev. H
- 29 -
If used, is the air pressure on the hydro air nozzle controlled to 25 psi
(170 kPa) maximum and monitored at least daily or prior to use?
YES
NO
NA
Developer Application
SECTION NA
YES
NO
YES
NO
YES
NO
YES
NO
6.10.3
6.10.4
PRI
6.10.5
AC7114/1 Rev. H
- 30 -
Are dwell times (in minutes) used by the supplier within the ranges
noted below? Please note all used. An explanation is not required for
not used.
Compliance Assessment Guidance: 20 to 120 minutes is between 10
to 240 minutes. The auditor shall include materials utilized for the wipeoff technique when completing section 6.10.5. If form d is utilized for
wipe-off only, the auditor should answer yes with an explanation.
6.11
Form: a
YES
NO
NA
Form: b
YES
NO
NA
Form: c
YES
NO
NA
Form: d
YES
NO
NA
SECTION NA
YES
NO
YES
NO
6.11.3
YES
NO
6.12
SECTION NA
Was the excess water removed from the parts prior to developer
application?
YES
NO
6.12.2
YES
NO
YES
NO
NA
PRI
AC7114/1 Rev. H
- 31 -
dryer is used, the set temperature used shall take into consideration
the tolerance of the dryer.
6.13
SECTION NA
YES
NO
YES
NO
6.14
Inspection Area
Compliance Assessment Guidance: The auditor shall verify compliance
to each of these requirements by direct observation.
6.14.1
YES
NO
6.14.2
YES
NO
YES
NO
YES
NO
6.15
Evaluation
Compliance Assessment Guidance: The following evaluation process
shall be determined by direct observation, and by researching the
specifications, procedures and other customer documents that are
applicable and required to reach an educated answer to each question.
6.15.1
PRI
AC7114/1 Rev. H
- 32 -
YES
NO
For Type I inspection, was the light intensity at the inspection surface
at the time of this survey at least 1200 W/cm2?
YES
NO
6.15.4
YES
NO
NA
YES
NO
NA
6.15.6
YES
NO
NA
6.15.7
YES
NO
NA
6.15.8
YES
NO
6.15.9
YES
NO
YES
NO
6.16
Post Cleaning
PRI
AC7114/1 Rev. H
- 33 -
YES
NO
NA
6.16.2
YES
NO
NA
6.17
Inspector Qualification
6.17.1
Were the inspection personnel certified to the correct levels for the
work they were performing?
YES
NO
YES
NO
NA
YES
NO
NA
6.17.3
Were all personnel who require near vision correction to pass the
visual acuity exam wearing vision correction for detection and
evaluation purposes during testing/inspections?
Compliance Assessment Guidance: The auditor shall verify that
corrective lenses were used if required. NA only where none of the
inspection personnel witnessed working required correction lenses.
6.18
Inspection Status
6.18.1
YES
NO
6.18.2
YES
NO