Professional Documents
Culture Documents
854984catalogue HEP 2011
854984catalogue HEP 2011
854984catalogue HEP 2011
Commercial/Industrial
Company Profile
Chemine Lining started out as a sales company that provided customers with quality products and installation. Our manufacturing
arose from the certitude that we could supply superior products and
services at a reasonable price.
With more than 15 years experience, our principles based on business
integrity, first class customer service, reliable delivery and engineering
services have established our reputation as a market leader for the
supply of chimneys, grease duct and gas venting products.
Personnel
Chemine Lining can count on qualified and highly professional employees. We are continually seeking to develop superior quality products at a competitive price.
Our engineering department will supply the answers you need either for a project involving our standard line of products or a uniquely
designed response to a specific requirement. We have developed
specialized design systems for highly efficient results on sizing analysis
and CAD design.
Our capabilities not only encompass the design and manufacturing
of gas venting products, but also include full range engineering expertise to assist you in your projects, from specification to installation.
Chemine Lining sales personnel work in an environment that promotes entrepreneurship. Their experience in the field allows them to
utilize their resources to provide our clients with the best technical
and economical solutions.
Manufacturing
Chemine Lining combines the craftsmanship of a seasoned labor
force with state of the art fabrication, delivering the highest quality
products in the industry.
Our stainless steel precision cut using state of the art equipment for
quality, speed and accuracy resulting in reduced manufacturing
lead times.
An innovative engineering staff ensures continuing research and
design, so that Chemine Lining can offer the latest in gas venting
products.
CONTENTS
SECTIONA
LISTING ANDAPPLICATIONS..............................................................................4
SECTIONB
FEATURESANDBENEFITS.....................................................................................5
SECTIONC
TECHNICALDATA................................................................................................7
SECTIOND
C
OMPONENTS
Lengths.............................................................................................................9
Lengths.
................................................................................................................ 9
Tees..................................................................................................................10
Tees.
.......................................................................................................................
Elbows.................................................................................................................
12
Elbows..............................................................................................................11
Fittings.
.................................................................................................................
15
Fittings.
.............................................................................................................14
Support.
............................................................................................................... 17
Support............................................................................................................15
Guides................................................................................................................. 18
Adapters.........................................................................................................17
Firestops............................................................................................................... 19
Guides.............................................................................................................18
Bands................................................................................................................... 21
Firestops...........................................................................................................19
Collars.................................................................................................................. 22
Bands...............................................................................................................21
Flashings..............................................................................................................
22
Flashings..........................................................................................................22
Terminations.
....................................................................................................... 24
Collars..............................................................................................................23
Terminations....................................................................................................25
SECTIONE
SPECIAL PARTS....................................................................................................27
SECTIONF
INSTALLATION.....................................................................................................28
LISTINGANDAPPLICATIONS
LISTINGS
CHEMINEE LINING.E inc. venting systems models HEP, HEPL and HEPL2 are listed by Underwriters Laboratories inc. (UL) under file
MH10081 and tested in accordance with UL 1738 and ULC-S636-95 standard for Venting Categories II, III and IV appliances.
TEMPERATURE
SIZE
550F continuous
6 to 48 I.D.
APPLICATIONS
1. Models HEP, HEPL and HEPL2 venting systems are not intended for use in one or two-family
dwellings.
2 . Where the venting system extends through any zone of a building outside the area in which the
heating appliance connected to it is located, it shall be provided with an enclosure having a
fire resistance rating equal to or greater than the fire rating of the floor, wall or roof assemblies
through which it passes.
3. Models HEP, HEPL and HEPL2 venting systemss may penetrate a combustible roof or wall
using the Ventilated Roof Flashing assembly. For wall penetrations, the use of the Wall Firestop
assembly is required. This is the only part intended for use with combustible construction. All
other parts, such as Anchor Plate and Wall Support, Wall Guide and Floor Guide are for attachment to non-combustible construction.
4. Where, according to local code, no chase enclosure is necessary, models HEP, HEPL and
HEPL2 may be placed adjacent to, in a corner or in an enclosure made of walls of combustible
materials at the clearance specified on each pipe section and in the individual listing; see
CLEARANCES. Contact local building or fire officials about restrictions and installation inspection in your area.
www.chemineelining.com
his unique method for jointing components together is very efficient either in horizontal or in vertical
installations. Our simple jointing concept along with the wide variety of components and accessories
allows a quick and simple installation, thus permitting you to save both time and money.
Chemine Lining is proud to present you with our HEP (High Efficiency Pressure) venting systems and can
assure you that it is the structurally strongest system of its category.
These chimney systems permit the exhaust of combustion gases, under positive, negative or neutral
pressure, emanating from a variety of appliances including:
Models HEP, HEPL and HEPL2 provide a wide variety of components and accessories, suitable for all
kinds of site conditions, thus allowing for quick and simple installation. Each component is packed and
shipped complete, with (1) one assembly band and (1) one finishing band for those having female
ends. Sufficient tubes of appropriate sealant are also included in the shipment for completing the
assembly.
www.chemineelining.com
MATERIALS
MODEL HEP
Inner wall: Stainless Steel as per UL 1738 (24ga - 6(305mm) to 48(1219mm) diameter)
MODEL HEPL
Inner wall: Stainless steel as per UL1738(24ga - 6(152mm) to 12(305mm) diameter; 24ga - 12(305mm) to 48(1219mm) diameter)
Outer wall: Stainless steel 301, 304, 316 OR 430 (24 ga - 6(152mm) to 42 1067mm) diameter; 20 ga - 42(1067mm) to
48(1219mm) diameter)
Insulation: 2(51mm) air space
MODEL HEPL2
Inner wall: Stainless Steel as per UL1738 (24ga - 6(152mm) to 12(305mm) diameter; 24ga - 12(305mm) to 48(1219mm) diameter)
Outer wall: Stainless steel 301, 304, 316 OR 430 (24 ga - 6(152mm) to 40(1016mm) diameter; 20 ga - 42(1067mm) to
48(1219mm) diameter)
Insulation: 2(51mm) high temperature insulation
COMPONENTS
ANCHOR PLATE
ASSEMBLY BAND
COLLARS, FLASHING
DRAIN SECTION
ELBOWS
EXHAUST CONE
FAN ADAPTER
FINISHING BAND
FIRESTOP, WALL FIRESTOP
HANGER BRACKET
INCREASER/REDUCER
INSULATED SLEEVE, INSULATED WALL FIRESTOP
LENGTHS, ADJUSTABLE LENGTH, VARIABLE LENGTH
RADIANT FIRESTOP
RAIN CAP, RAINSHIELD, CLOSURE SECTION
ROOF BAND, GUY WIRE BAND
ROOF SUPPORT, GUIDING SPACER
STARTING ADAPTER, STARTING DRAIN ADAPTER
STARTING SLEEVE
TEES
TEE CAPS
WALL BAND, SUSPENSION BAND
WALL/FLOOR GUIDES
WALL/HORIZONTAL SUPPORTS
www.chemineelining.com
materials
STANDARD AVAILABLE
3
---
---
---
---
---
---
---
3
3
---
3
---
3
---
1
3
3
3
---
---
3
3
3
1, 2 and 4
--1 and 2
----------1 and 2
1, 2 and 4
--1 and 2
--1 and 2
--2, 3 and 4
1, 2 and 4
1,2 and 4
1, 2 and 4
----1, 2 and 4
1,2 and 4
1, 2 and 4
I.D.
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
LINEAR WEIGHT
O.D.
mm
152
203
254
302
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
in2
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
1000mm2
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
1270
1321
AREA
lb/ft
28
50
79
113
154
201
254
314
380
452
531
616
707
804
908
1018
1134
1257
1385
1521
1662
1810
HEP
kg/m
18.2
32.4
50.7
73.0
99.3
129.7
164.2
202.7
245.2
291.9
342.5
397.3
456.0
518.9
585.8
656.7
731.7
810.7
893.8
981.0
1072.2
1167.5
lb/ft
2.2
2.9
3.6
4.3
5.1
5.8
6.5
7.2
7.9
8.7
9.4
10.1
10.8
11.5
12.3
13.0
13.7
14.4
15.2
15.9
16.6
17.3
HEPL
kg/m
3.2
4.3
5.4
6.4
7.5
8.6
9.7
10.7
11.8
12.9
14.0
15.0
16.1
17.2
18.3
19.3
20.4
21.5
22.6
23.6
24.7
25.8
lb/ft
5.1
6.3
7.6
8.9
10.2
11.5
12.8
14.1
15.4
16.7
18.0
19.3
20.6
21.9
23.2
24.5
25.8
27.1
35.0
36.6
38.2
39.8
HEPL2
kg/m
7.5
9.4
11.4
13.3
15.2
17.2
19.1
21.0
23.0
24.9
26.8
28.8
30.7
32.6
34.6
35.4
36.5
40.4
52.1
54.5
56.8
59.2
lb/ft
8.0
10.0
12.0
14.1
16.1
18.1
20.2
22.2
24.2
26.3
28.3
30.3
32.4
34.4
36.4
38.5
40.5
42.5
51.1
53.5
55.8
58.1
kg/m
11.9
14.9
17.9
21.0
24.0
27.0
30.0
33.0
36.1
39.1
42.1
45.1
48.2
51.2
54.2
57.2
60.3
66.3
76.1
79.5
83.0
86.4
MODEL
INSIDE
Unenclosed
vertical DIAMETER
(IN)
0.5 1
HEP
1.5
6
8 to 10 12 to 14 16 to 20 22 to 24 26 to 28 30 to 32 34 to 38 40 to 44 46 to 48
HEPL
HEPL2
6 8 to 10 12 to 14 16 to 20 22 to 24 26 to 30 32 to 36 38 to 40 42 to 48
HEP
6 to 10 12 to 14 16 to 20 22 to 30 32 to 38 40 to 42 44 to 48
HEPL
6 to 10 12 to 14
16 to 20 22 to 28 30 to 32 34 to 38 40 to 42 44 to 48
HEPL2
6 to 10 12 to 14 16 to 20 22 to 30
INSIDE
Unenclosed
Horizontal DIAMETER
(IN)
10
8 to 10 12 to 14 16 to 18 20 to 24 26 to 28 30 to 32 34 to 36 38 to 42 44 to 48
32
34 to 44 46 to 48
Diameter
6 to 16
18 to 32
Enclosed
vertical
HEPL
HEPL2
1
1
1
1
Enclosed
horizontal
HEPL
HEPL2
3
2
---
---
Minimum opening when installing a chimney through a floor or wall made of combustible construction.
O.D. + 2 X (min. clearance air space) Ex.: HEPL2, B.H.A., O.D. = 12
12 + (2 X 2) = 16
Minimum opening when installing a chimney through a floor or wall made of non combustible construction.
O.D. + 1 Ex.: HEPL2, B.H.A., O.D. = 12 12 + 1 = 13
www.chemineelining.com
l
OFFSET dimension is known
l
Effective length is to be determined using equation 1, 2 or
3 depending on elbows used
15 elbows
30 elbows
45 elbows
EXAMPLE:
An 8 ID IPPL2 chimney with a known offset
width of 44.75(A)using 2-45 elbows.
3. L(A) = 1.414(A) - 0.414D - 13
L(A) = 1.414(44.75) - 0.414(8) - 13
L(A) = 47 in effective length choose a 48
length (48L)
A
KNOWN
l
HEIGTH dimesnion is known
l
Effective length is to be determined using equation 4, 5 or
6 depending on elbows used
B
KNOWN
15 elbows
30 elbows
45 elbows
45 TEEAND45 ELBOWASSEMBLY
HEP l HEPL l HEPL2
I.D.
A
i n
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
O.D.
in mm
10 254
12 305
14 356
16 406
18 457
20 508
22 559
24 610
26 660
28 711
30 762
32 813
34 864
36 914
38 965
40 1016
42 1067
44 1118
46 1168
48 1219
50 1270
52 1321
in
26.471
28.885
31.299
33.713
36.127
38.542
40.956
43.370
45.784
48.198
50.613
53.027
55.441
57.855
60.270
62.684
65.098
67.512
69.926
72.341
74.755
77.169
mm
672
734
795
856
918
979
1040
1102
1163
1224
1286
1347
1408
1470
1531
1592
1653
1715
1776
1837
1899
1960
www.chemineelining.com
in mm
27.471 698
29.885 759
32.299 820
34.713 882
37.127 943
39.542 1004
41.956 1066
44.370 1127
46.784 1188
49.198 1250
51.613 1311
54.027 1372
56.441 1434
58.855 1495
61.270 1556
63.684 1618
66.098 1679
68.512 1740
70.926 1802
73.341 1863
75.755 1924
78.169 1985
in
35.213
38.042
40.870
43.698
46.527
49.355
52.184
55.012
57.841
60.669
63.497
66.326
69.154
71.983
74.811
77.640
80.468
83.296
86.125
88.953
91.782
94.610
mm
894
966
1038
1110
1182
1254
1325
1397
1469
1541
1613
1685
1757
1828
1900
1972
2044
2116
2188
2259
2331
2403
in
18.728
20.728
22.728
24.728
26.728
28.728
30.728
32.728
34.728
36.728
38.728
40.728
42.728
44.728
46.728
48.728
50.728
52.728
54.728
56.728
58.728
60.728
mm
476
526
577
628
679
730
780
831
882
933
984
1034
1085
1136
1187
1238
1288
1339
1390
1441
1492
1542
LENGTHS
STRAIGHTLENGTHS 36L 24L 12L
Available in 22 diameters from 6 to 48 (152 to
1219mm). Standard lengths: 36 (914mm), 24
(610mm) and 12 (305mm).
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
K = 0.30 L/D
Where
I.D
O.D
EFFECTIVE
LENGTHS A
11
23
35
LENGTHS
12
24
2.250
36
(57mm)
ADJUSTABLELENGTH AL
Used to complete on site installation precisely. It is not designed to compensate for
linear expansion nor to support the vertical
load of the chimney.
Includes:
1 Assembly band (AB)
1 Outer wall 36 (914mm) long
1 Strip of insulation for HEPL2 systems
K = Same as pipe length
O.D
I.D.
7.250
(184mm)
to
21.750
(552mm)
VARIABLE LENGTH VL
DRAINSECTION DS
Used to collect rainwater or condensation water from inside
vertical or horizontal flue. To be connected to a drain of 3/4
(19mm) - NPT.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
O.D
I.D.
7.250
(184mm) TO
21.750
(552mm)
I.D.
11.000
(279mm)
6.250
(159mm)
O.D.
2.500
(64mm)
www.chemineelining.com
Section D Components
TEES
45 TEE T45
For connection of vertical and horizontal lengths at a 45 angle. It provides low resistance to facilitate gas discharge. A tee cap
(TC) or drain-tee cap (DC) may be used to block one of the cleaning or drainage openings.
Includes:
1 Assembly band (AB)
HEPL l HEPL2
I.D
1 Finishing band (FB)
I.D.
A
B
C
B
K = 0.4
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
45
2.500
(64mm)
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
in
27.485
30.314
33.142
35.971
38.799
41.627
44.456
47.284
50.113
52.941
55.770
58.598
61.426
64.255
67.083
69.912
72.740
75.569
78.397
81.225
84.054
86.882
mm in
698 8.743
770 9.157
842 9.571
914 9.985
985 10.399
1057 10.814
1129 11.228
1201 11.642
1273 12.056
1345 12.471
1417 12.885
1488 13.299
1560 13.713
1632 14.127
1704 14.542
1776 14.956
1848 15.370
1919 15.784
1991 16.198
2063 16.613
2135 17.027
2207 17.441
mm in
mm
222 18.743 476
233 21.157 537
243 23.571 599
254 25.985 660
264 28.399 721
275 30.814 783
285 33.228 844
296 35.642 905
306 38.056 967
317 40.471 1028
327 42.885 1089
338 45.299 1151
348 47.713 1212
359 50.127 1273
369 52.542 1335
380 54.956 1396
390 57.370 1457
401 59.784 1519
411 62.198 1580
422 64.613 1641
432 67.027 1702
443 69.441 1764
90 TEE T90
For connection of vertical and horizontal lengths. May be used for the installation of a draft regulator at the point of connection
between the flue and the appliance. A tee cap (TC) or drain-tee cap (DC) may be used to block one of the cleaning or drainage
openings.
HEPL l HEPL2
Includes:
1 Assembly band (AB)
I.D.
A
B
1 Finishing band (FB)
K = 1.25
O.D.
2.500
(64mm)
A
B
2.500
(64mm)
10
www.chemineelining.com
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
in
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
61
mm
438
533
584
635
686
737
787
838
889
940
991
1041
1092
1143
1194
1245
1295
1346
1397
1448
1499
1549
in
9.5
10.5
11.5
12.5
13.5
14.5
15.5
16.5
17.5
18.5
19.5
20.5
21.5
22.5
23.5
24.5
25.5
26.5
27.5
28.5
29.5
30.5
mm
241
267
292
318
343
368
394
419
445
470
495
521
546
572
597
622
648
673
699
724
749
775
Section D Components
ELBOWS
5 ELBOW E5
Used to offset the flue or chimney by 5. May be used to slope a
flue to facilitate condensation water run-off.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
K = 0.04
A
A
2.500
(64mm)
I.D.
HEPL l HEPL2
A
B
I.D.
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
in
6.631
6.675
6.718
6.762
6.806
6.849
6.893
6.937
6.980
7.024
7.068
7.111
7.155
7.199
7.242
7.286
7.330
7.373
7.417
7.461
7.504
7.548
mm in
168 26.473
170 26.648
171 26.822
172 26.996
173 27.171
174 27.345
175 27.519
176 27.694
177 27.868
178 28.042
180 28.217
181 28.391
182 28.595
183 28.740
184 28.914
185 29.088
186 29.262
187 29.437
188 29.611
189 29.785
191 29.960
192 30.134
C
mm
672
677
681
686
690
695
699
703
708
712
717
721
726
730
734
739
743
748
752
757
761
765
in
mm
1.156 29
1.163 30
1.171 30
1.179 30
1.186 30
1.194 30
1.202 31
1.209 31
1.217 31
1.224 31
1.232 31
1.240 31
1.247 32
1.255 32
1.262 32
1.270 32
1.278 32
1.285 33
1.293 33
1.300 33
1.308 33
1.316 33
15 ELBOW E15
Used to offset the flue or chimney by 15.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
K = 0.06
2.500
(64mm)
I.D.
HEPL l HEPL2
A
B
I.D.
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
www.chemineelining.com
in
6.895
7.027
7.158
7.290
7.422
7.553
7.685
7.817
7.948
8.080
8.211
8.343
8.475
8.606
8.738
8.870
9.001
9.133
9.265
9.396
9.528
9.660
mm
175
178
182
185
189
192
195
199
202
205
209
212
215
219
222
225
229
232
235
239
242
245
in
27.110
27.628
28.145
28.663
29.181
29.698
30.216
30.733
31.251
31.769
32.804
32.322
33.322
33.839
34.357
34.875
35.392
35.910
36.427
36.945
37.463
37.980
mm
689
702
715
728
741
754
767
781
794
807
820
833
846
860
873
886
899
912
925
938
952
965
C
in
mm
3.569 91
3.637 92
3.705 94
3.774 96
3.842 98
3.910 99
3.978 101
4.046 103
4.114 105
4.182 106
4.251 108
4.319 110
4.387 111
4.455 113
4.523 115
4.591 117
4.659 118
4.728 120
4.796 122
4.864 124
4.932 125
5.000 127
11
Section D Components
ELBOWS
30 ELBOW E30
Used to offset the flue or chimney by 30.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
K = 0.12
2.500
(64mm)
I.D
I.D.
I.D
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
HEPL l HEPL2
A
B
in
7.304
7.572
7.894
8.108
8.376
8.644
8.912
9.179
9.447
9.715
9.983
10.251
10,519
10.787
11.055
11.323
11,591
11.859
12.127
12.395
12.663
12.931
mm in
186 27.258
192 28.258
199 29.258
206 30.258
213 31.258
220 32.258
226 33.258
233 34.258
240 35.258
247 36.258
254 37,258
260 38.258
267 39.258
274 40.258
281 41.258
288 42.258
294 43.258
301 44.258
308 45.258
315 46.258
322 47.258
328 48.258
mm in
692 7.304
718 7.527
743 7.840
769 8.108
794 8.376
819 8.644
845 8.912
870 9.179
896 9.447
921 9.715
946 9.983
972 10.251
997 10.519
1023 10.787
1048 11.055
1073 11.323
1099 11.591
1124 11.859
1150 12.127
1175 12.395
1200 12.663
1226 12.931
mm
186
192
199
206
213
220
226
226
240
247
254
260
267
274
281
288
294
301
308
315
322
328
45 ELBOW E45
Used to offset the flue or chimney by 45.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
K = 0.15
A
B
I.D
12
I.D
2.500
(64mm)
I.D.
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
www.chemineelining.com
HEPL l HEPL2
A
B
in
26.235
19.064
31.892
34.721
37.549
40.377
43.206
46.034
48.863
51.691
54.520
57.348
60.176
63.005
65.833
68.662
71.490
74.319
77.147
79.975
82.804
85.632
mm in
666 6.993
738 7.407
810 7.821
882 8.235
954 8.649
1026 9.024
1097 9.478
1169 9.892
1241 10.306
1313 10.721
1385 11.135
1457 11.549
1528 11.963
1600 12.377
1672 12.792
1744 13.206
1816 13.260
1888 14.034
1960 14.448
2031 14.863
2103 15.277
2175 15.691
mm in
mm
178 19.243 489
188 21.657 550
199 24.071 611
209 26.485 673
220 28.889 734
230 31.314 795
241 33.728 857
251 36.142 918
262 38.556 979
272 40.971 1041
283 43.385 1102
293 45.799 1163
304 48.213 1225
314 50.627 1286
325 53.042 1347
335 55.456 1409
346 57.870 1470
356 60.284 1531
367 62.628 1593
378 65.113 1654
388 67.527 1715
399 69.941 1777
Section D Components
ELBOWS
90 ELBOW 2 x E45
Used to change orientation of flue or chimney by 90.
Includes:
2 45 Elbows (E45)
2 Assembly bands (AB)
2 Finishing bands (FB)
K = 0.3
HEPL l HEPL2
I.D.
A
in mm
in
6 152 18.692
8 203 19.692
10 254 20.692
12 305 21.692
14 356 22.692
16 406 23.692
18 457 24.693
20 508 25.692
22 559 26.692
24 610 27.692
26 660 28.692
28 711 29.692
30 762 30.692
32 813 31.692
34 864 32.692
36 914 33.692
38 965 34.692
40 1016 35.692
42 1067 36.692
44 1118 37.692
46 1168 38.692
48 1219 36.692
mm
475
500
526
551
576
602
627
653
678
703
729
754
780
805
830
856
881
907
932
957
983
1008
HEPL l HEPL2
I.D.
A
in mm
in
6 152 12.328
8 203 13.328
10 254 14.328
12 305 15.328
14 356 16.328
16 406 17.328
18 457 18.328
20 508 19.328
22 559 20.328
24 610 21.328
26 660 22.328
28 711 23.328
30 762 24.328
32 813 25.328
34 864 26.328
36 914 27.328
38 965 28.328
40 1016 29.328
42 1067 30.328
44 1118 31.328
46 1168 32.328
48 1219 33.328
mm
313
339
364
389
415
440
466
491
516
542
567
593
618
643
669
694
720
745
770
796
821
847
I.D
2.500
(64mm)
www.chemineelining.com
13
Section D Components
FITTINGS
REDUCER R
INCREASER I
Used to increase the diameter of the flue or chimney.
Specify the diameter of the inlet and outlet of the fitting.
Includes:
1 Assembly band (I.D. 2) (AB)
1 Finishing band (O.D. 2) (FB)
Used to reduce the diameter of the flue. Specify the diameter of the inlet and outlet of the fitting.
Includes:
1 Assembly band (I.D. 2) (AB)
1 Finishing band (O.D. 2) (FB)
K = 0.5 1- I.D.1
I.D.2
K = 0.5 1- I.D.1
I.D.2
( ( ))
2
( ( ))
2
I.D 2
I.D 2
2.500
(64mm)
I.D 1
I.D 1
Difference
between
I.D 2 - I.D. 1
2
4
6
8
10
2.500
(64mm)
Difference
between
I.D 2 - I.D. 1
2
4
6
8
10
TEE CAP TC
DRAIN-TEE CAP DC
Used to cover one of the vertical openings of tee. For collection of rainwater or condensation water. Removable, it facilitates access for inspection and maintenance of the chimney.
To be connected to a drain of 3/4 (19mm) - NPT.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
I.D.
I.D.
5.500
(140mm)
5.500
(140mm)
DRAIN 1 (25mm)
HANDLE
14
14
www.chemineelining.com
Section D Components
SUPPORTS
WALLSUPPORT WS
Used to support the chimney in vertical runs. It keeps the chimney at an adjustable
distance between 4 (102mm) and 10 (254mm) from the wall. The oblique braces may
be attached to the wall either above or below the supporting surface.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
2 Adjustable angles
2 Braces
4 Wall brackets
K = Same as pipe length
AJUSTABLE
4.000 TO 10.000
(102mm TO 204mm)
11.000
(279mm)
I.D.
2.500
(64mm)
HEPL l
I.D.
in
mm
6
152
8
203
10
254
12
305
14
356
16
406
18
457
20
508
22
559
24
610
26
660
28
711
30
762
32
813
34
864
36
914
38
965
40
1016
42
1067
44
1118
46
1168
48
1219
HEPL l
I.D.
in
mm
6
152
8
203
10
254
12
305
14
356
16
406
18
457
20
508
22
559
24
610
26
660
28
711
30
762
32
813
34
864
36
914
38
965
40
1016
42
1067
44
1118
46
1168
48
1219
HEPL2
A
in
14.000
16.000
18.000
20.000
22.000
24.000
26.000
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
46.000
48.000
50.000
52.000
54.000
56.000
mm
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
1270
1321
1372
1422
HORIZONTALSUPPORT HS
Used to support the flue in horizontal runs. It keeps the flue at an adjustable distance
from the ceiling. The oblique braces (not included) may be attached to the ceiling
either ahead of or behind the supporting surface.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
4 Wall brackets
K = Same as pipe length
BY OTHERS
2.500
(64mm)
I.D.
11.000
(279mm)
www.chemineelining.com
HEPL2
A
in
14.000
16.000
18.000
20.000
22.000
24.000
26.000
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
46.000
48.000
50.000
52.000
54.000
56.000
mm
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
1270
1321
1372
1422
15
Section D Components
SUPPORTS
ANCHOR PLATE AP
Used to support the chimney in vertical runs. It is attached to the floor by means of anchors
(not included). It is designed to be supported on four (4) sides. Structural angles may be
used to support sides that are unsupported.
Includes:
1 Assembly band (AB)
1 Finishing band (FB)
K = Same as pipe length
I.D.
11.000
(279mm)
2.500
(64mm)
AxA
ROOF SUPPORT RS
HANGER BRACKET HB
O.D.
2.500 (64mm)
A
I.D.
in
mm
6 to 14
152 to 356
16 to 22
406 to 559
24 to 32
610 to 813
34 to 42
965 to 1067
44 to 48 1118 to 1219
16
in
5.250
7.250
9.250
1.250
13.250
2.500
(64mm)
A
mm
133
184
235
286
337
www.chemineelining.com
O.D. + 0.250
(O.D. + 6mm)
1.500
(38mm)
Section D Components
VARIABLE
VARIABLE
I.D.
TEST PLUG
1/2 (13mm) NPT
I.D.
TEST PLUG
1/2 (13mm) NPT
GUIDING SPACER GS
FLOOR GUIDE FG
Used as a guide at floor penetrations. It is attached to
the floor by means of four (4) angles. It keeps a minimum
distance between the chimney and combustible floor
materials.
Used to guide the flue or the chimney against the inner wall
of the sleeves it passes through. It holds the chimney at a
distance of 2 (51mm) from the wall firestop (WFS), insulated
wall firestop (IFS) or an insulated sleeve (IS).
O.D. + 0.250
(O.D. + 6mm)
O.D.
2.250 (57mm)
A
I.D.
in
mm
6 to 14
152 to 356
16 to 22
406 to 559
24 to 32
610 to 813
34 to 42
965 to 1067
44 to 48 1118 to 1219
in
5.250
7.250
9.250
1.250
13.250
A
mm
133
184
235
286
337
in
I.D.
mm
to 16 152 to 406
6
18 to 36 457 to 914
38 to 48 965 to 1219
www.chemineelining.com
in
mm
4.000
6.000
8.000
102
152
203
17
Section D Components
GUIDES
WALL GUIDE WG
Used as a guide and to allow for expansion of the flue or chimney.
It may be used either horizontally or vertically. The oblique braces
(not included) may be attached above or below the guide plate.
in
Includes:
6
4 Wall brackets
BY OTHERS
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
I.D.
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
HEPL l HEPL2
A
in
10.250
12.250
14.250
16.250
18.250
20.250
22.250
24.250
26.250
28.250
30.250
32.250
34.250
36.250
38.250
40.250
42.250
44.250
46.250
48.250
50.250
52.250
mm
260
311
362
413
464
514
565
616
667
718
768
819
870
921
972
1022
1073
1124
1175
1226
1276
1327
B
in
14.000
16.000
18.000
20.000
22.000
24.000
26.000
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
46.000
48.000
50.000
52.000
54.000
56.000
STORM COLLAR SC
VENTILATED COLLAR VC
O.D.
4.000
(102mm)
O.D.
6.000
(152mm)
4.000
(102mm)
STANDARD
O.D. + 8.000
(O.D. + 203mm)
WITH INSULATED SLEEVE (IS)
O.D. + 14 (O.D. + 356mm)
O.D. + 4.000
(O.D. + 102mm)
18
mm
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1068
1118
1168
1219
1270
1321
1372
1422
www.chemineelining.com
Section D Components
FIRESTOPS ANDGUIDES
WALL FIRESTOP WFS
Used to keep a minimum clearance from combustible materials where the flue passes through a wall.
18.000 max.
(457mm)
O.D.+.125
(105mm)
A
17.625
(448mm)
HEP, HEPL,HEPL2
A = O.D + 2*Clearance + 4
B = O.D + 2*Clearance
C = O.D + 2*Clearance + 12
www.chemineelining.com
19
Section D Components
FIRESTOPS
FIRESTOP FS
Used to keep space between any combustible material of a wall, floor or roof, where a flue or chimmey penetrates.
O.D. + 0.125
(3mm)
ASSEMBLY BAND AB
FINISHING BAND FB
I.D. +1
I.D +25mm
O.D
7.250
(184mm)
2.150
(55mm)
20
www.chemineelining.com
Section D Components
BANDS
SUSPENSION BAND SB
WALL BAND WB
Used to stabilize the chimney along a vertical wall. The maximum recommended spacing between wall bands is 10-0
(3048mm).
Includes:
1 Wall brackets
1 Stabilizing angles
O.D.
O.D.
00
2.5 mm)
(64
8.000
(203mm)
ROOF BAND RB
Used to stabilize a chimney laterally where it extends more than 10-0 (3048mm) above the roof or for locations exposed to
strong winds. It is attached to the chimney and the roof curb and does not require anchoring to the roof.
O.D.
2.500
(64mm)
www.chemineelining.com
21
Section D Components
2.500
(64mm)
O.D.
ADJUSTABLE FLASHING AF
Used to seal the space between the chimney and the roof. Specify the roof slope when ordering.
Includes:
1 Storm collar (SC)
O.D.
VA
R.
VA
R.
22
www.chemineelining.com
Section D Components
VARIABLE
O.D.
5.250
(133mm)
2.500
(64mm)
I.D.
4.000
(102mm)
O.D. + 4.000
(O.D. + 102mm)
O.D.
4.000
(102mm)
6.000
(152mm)
STANDARD
O.D. + 8.000
(O.D. + 203mm)
WITH INSULATED SLEEVE (IS)
O.D. + 14 (O.D. + 356mm)
www.chemineelining.com
23
Section D Components
FLASHINGS
FLATFLASHING F
Used to seal the space between the chimney and
the roof.
Includes:
1 Storm collar (SC
O.D.
SEE STROM
COLLAR (SC)
A
B
I.D.
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
457
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
HEPL l HEPL2
A
in
13.000
15.000
17.000
19.000
21.000
23.000
25.000
27.000
29.000
31.000
33.000
35.000
37.000
39.000
41.000
43.000
45.000
47.000
49.000
51.000
53.000
55.000
mm
300
381
432
483
533
584
635
686
737
787
838
889
940
991
1041
1092
1143
1194
1245
1295
1346
1397
in
12.000
12.000
12.000
12.000
12.000
12.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
16.000
mm
305
305
305
305
305
305
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
406
VENTILATEDFLASHING VF
Used to seal and ventilate the space between the chimney and the roof. It
reduces the temperature around the roof opening and it prevents excessive
accumulation of heat near combustible materials.
Includes:
1 Ventilated collar (VC)
10.000
(254mm)
SEE VENTILATED
COLLAR (VC)
12.000
(305mm)
A
24
www.chemineelining.com
HEPL l HEPL2
I.D.
A
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
in
14.000
16.000
18.000
20.000
22.000
24.000
26.000
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
46.000
48.000
50.000
52.000
54.000
56.000
mm
356
406
457
508
559
610
660
711
762
813
864
914
964
1016
1067
1118
1168
1219
1270
1321
1372
1422
Section D Components
TERMINATIONS
RAIN CAP RC
HEPL l HEPL2
I.D.
K = 0.5
I.D. x 2
I.D./2
I.D.
in mm
6 152
8 203
10 254
12 305
14 356
16 406
18 457
20 508
22 559
24 610
26 660
28 711
30 762
32 813
34 864
36 914
38 965
40 1016
42 1067
44 1118
46 1168
48 1219
A
in
mm
11.500 292
13.500 343
15.500 394
17.500 445
19.500 495
21.500 546
23.500 597
25.500 648
27.500 699
29.500 749
31.500 800
33.500 851
35.500 902
37.500 953
39.500 1003
41.500 1054
43.500 1105
45.500 1156
47.500 1207
49.500 1257
51.500 1308
53.500 1359
EXHAUSTCONE EC
Installed at the top of the chimney. It improves the draft and
increases the speed of exhaust gases by 50%. Installation of a
drain-tee cap (DC) or a drain section (DS) at the base of the
chimney is required for use of an exhaust cone.
K = 1.25
B
A
I.D.
I.D.
in
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
mm
152
203
254
305
356
406
457
508
559
610
660
711
762
813
864
914
965
1016
1067
1118
1168
1219
www.chemineelining.com
HEPL l HEPL2
A
B
in
mm in
mm in
mm
5.000 127 9.000 229 17.750 451
7.000 178 11.000 279 17.750 451
8.000 203 12.000 305 17.750 451
10.000 254 14.000 356 17.750 451
12.000 305 16.000 406 23.500 497
14.000 356 18.000 457 23.500 497
16.000 406 20.000 508 23.500 497
16.000 406 20.000 508 23.500 497
18.000 457 22.000 559 23.500 497
20.000 508 24.000 610 23.500 497
22.000 559 26.000 660 29.500 749
24.000 610 28.000 711 29.500 749
24.000 610 28.000 711 29.500 749
26.000 660 30.000 762 35.500 902
28.000 711 32.000 813 35.500 902
30.000 762 34.000 864 35.500 902
30.000 762 34.000 864 41.500 1054
32.000 813 36.000 914 41.500 1054
34.000 864 38.000 965 41.500 1054
36.000 914 40.000 1016 41.500 1054
38.000 965 42.000 1067 41.500 1054
40.000 1016 44.000 1118 41.500 1054
25
Section D Components
TERMINATIONS
CLOSURE SECTION CS
MITER SECTION MS
5.500
(140mm)
2.500
(64mm)
1/2 (13mm)
STAINLESS STEEL
BIRD SCREEN
I.D.
2.500
(64mm)
I.D.
I.D.
7.500
(191mm)
RAINSHIELD RSH
FAN ADAPTER FA
Installed at the top of the chimney. It prevents rain penetration when the chimney is installed at a location subject to
high wind conditions. Installation of a drain-tee cap (DC) or
drain section (DS) at the base of the chimney is required for
use of a rainshield. Available from 6 (152mm) to 16 (406mm)
diameter.
O.D + 2
5.000
(127mm)
2.500
(64mm)
26
I.D.
I.D.
in
6
8
10
12
14
16
A
in
43.500
49.500
55.500
61.500
67.500
74.500
I.D.
mm
152
203
254
305
356
406
A
mm
1105
1257
1410
1592
1715
1892
www.chemineelining.com
VARIABLE
5.250
(133mm)
2.500
(64 mm)
I.D.
SPECIAL PART
Several special parts are available upon request.
See some examples below.
I.D. 2
C
B
I.D. 1
C
B.C.
I.D.
O.D.
HOLES
B.C.
O.D.
B
A
D
B
C
B
Special Elbow
Finishing Cone
A
A
Double 45 Tee
DRAIN
D
B
BXC
www.chemineelining.com
27
Section F Installation
INSTALLATIONGUIDE
Guide to Component Parts
MATERIALS
CODE
PAGE
ADJUSTMENT/EXPANSION
Adjustable Length
Increaser
Reducer
Variable Length
AL
I
R
VL
9
14
14
9
COMPONENT
Drain Section
Drain-Tee Cap
Tee Cap
DS
DC
TC
9
14
14
SAD
SA
17
17
CONNECTION/OFFSET
5 Elbow
15 Elbow
30 Elbow
45 Elbow
90 Elbow
90 Short Radius Elbow
45 Tee
90 Tee
E5
E15
E30
E45
2 xE45
E90
T45
T90
11
11
12
12
13
13
10
10
FIRE PROTECTION
Firestop
Radiant Firestop
Wall Firestop
FS
RFS
WFS
20
19
19
JOINTING
Assembly Band
Finishing Band
AB
FB
20
20
MATERIALS
CODE
PAGE
LENGTH
12 Length
24 Length
36 Length
12L
24L
36L
9
9
9
SEALING AT ROOF
Adjustable Flashing
Flashing for Flat Roof
Ventilated Flashing
AF
F
VF
22
23
23
GWB
RB
WB
22
21
21
SUPPORT/GUIDE
Anchor Plate
Floor Guide
Guiding Spacer
Hanger Bracket
Horizontal Support
Roof Support
Suspension Band
Wall Guide
Wall Support
AP
FG
GS
HB
HS
RS
SB
WG
WS
16
17
17
16
15
16
21
18
15
TERMINATIONS
Closure Section
Exhaust Cone
Fan Adapter
Miter Section
Rain Cap
Rainshield
CS
EC
FA
MS
RC
RSH
25
24
25
25
24
25
SIDE STABILITY
Guy Wire Band
Roof Band
Wall Band
7. FOR OUTDOOR INSTALLATION AND BAD WEATHER PROTECTION, AN EXTERIOR SEALANT (ES)
IS APPLIED AT THE JOINT BETWEEN THE FINISHING BAND (FB) AND THE OUTER WALL OF THE CHIMNEY.
28
www.chemineelining.com
Section F Installation
Part No.
Dynaflames df-750
HELPSAD1004-STD
HEPLAL1004
HEPLE91004
HEPL24L1004
HEPLAL1004
HEPLE451004
HEPLT451004
HEPLTC1004
HEPLT45101604
HEPL101604
HEPLSB1604
HEPLAL1604
HEPLHB1004-04
HEPL36L1604
HEPLHB1004-04
HEPLHB1604-04
HEPLVC1604-04
HEPLVF1604-04
HEPLFG1604-04
HEPLRC1604
HEPLT451604
HEPLE451604
HEPL12L1604
HEPLHS1604-04
HEPLDC1604
Description
Page
Boiler (by others) --Starting Adapter 17
Adjustable Length 9
90 Elbow
13
24 Length
9
Adjustable length 9
45 Elbow
12
45 Tee
14
Tee Cap
14
Special Tee 45 --Increaser
14
Suspension Band 21
Adjustable Length 9
Hanger Bracket
16
36 Length
9
Hanger Bracket
16
Hanger Bracket
16
Ventilated Collar 18
Ventilated Flashing 23
Floor guide
17
Rain cap
24
Tee 45
9
45 Elbow
12
12 Length 9
Horizontal Support 15
Drain Tee Cap
14
21
15
18
17
19
14
15
10
15
11
20
13
22
8
25
16
26
23
15
24
5
6
www.chemineelining.com
12
29
Section F Installation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Part no.
Description
Page
--17
9
13
9
9
12
14
14
9
9
25
19
16
16
21
12
9
7
13
11
11
15
14
14
11
7
10
16
4
1
30
www.chemineelining.com
warranty
This warranty is limited to repair or replacement of any component which has been proven de
fective by a factory-authorized inspector by Chemine Lining.e inc. This warranty does not cover
any labour cost or freight charge for removal or replacement of the defective product, nor does
this warranty cover any system component not furnished by Chemine Lining.e inc. and installed
as part of the system. The warranty on any repaired or replacement component shall be for a
duration no longer than the remaining or unexpired term of the original warranty.
Factory-built
Positive Pressure Piping System
Boiler and Engine Exhaust
Special gas vents
Restaurant Grease Duct
Freestanding
Steel Stacks
Breeching Systems
MODELS
STS STS2 STS3 STSR
Accessories
Control Dampers
Expansion Joints
Professional Services
Engineering Services
Quality Control
Sales and Customer
Reliable Delivery services
Tests Facilities
CAD design
Research and
Distribution Network in
development Canada and in the US