Exhibit C  

 
BuildSmart Checklist 
To receive a Build Smart Home certification the home shall contain 75%   of the below checklist.  All “Mandatory” items must be 
implemented to receive certification. Some items may not be applicable and will not be included in total percentage tallies. 
(Modifications and additions still in process) 
 
Action Items   Application   Verification  Voluntary 
  (V) or 
Mandatory 
(M) 
Water Conservation  
Locate water heaters so that kitchen and all bathrooms are within  Tankless water heaters, also called instantaneous or demand  Checked during  V 
35' of total pipe per run or fixtures more than 35 feet from water  water heaters, provide hot water only as it is needed.   plan review and at 
heater use tankless water heater.    final inspection. 
 
Tankless water heaters heat water directly without the use of   
a storage tank, and deliver a constant supply of hot water. 
Gas‐fired models must have a minimum Energy Factor of 
0.82. BS 
Install on‐demand hot water recirculation system controlled by    Checked during  V 
occupancy sensor or user activated switch.  plan review and at 
final inspection. 
Install Energy Star dishwasher and laundry machine. ENERGY  Appliance ENERGY STAR labels must remain on the  Checked at C of O  M 
STAR dishwasher and laundry machines use 50% less water.  equipment. 

Toilets, urinals, faucets and showerheads all conform to EPA  WaterSense Label  are tested, certified, and approved by a  Documenting  M 


water sense standards or use 20% less water than the current  third party laboratory to ensure they meet EPA water  materials to 
federal standard  efficiency and performance criteria of 20% more efficient  building 
than the federal standard.   department prior to 
C of O. 
Install composting and/or waterless toilets and urinals.    Checked at final  V 
inspection.  
 
Install excess water flow shutoff, leak detection system or alarm    Checked at final  V 
based shutoff sensor.  inspection.  
 
Draft Checklist_04_13_10
Non turf landscape is irrigated by drip irrigation, bubblers or    Check C of O  V 
soaker hose  
Non turf landscaping is controlled by a smart controller    Check C of O   M 
incorporating rain sensor and/or soil sensor. 
Irrigate turf areas with subsurface irrigation system    Check at  C of O  V 
All irrigated turf landscaping is controlled by a smart controller    Site inspection.  M 
incorporating rain sensor and/or soil sensor. 
Install whole house water filtration system.    Inspected at plan  V 
review and site 
inspection. 
Grey and rain water harvesting and reuse.    Inspect at C of O.  V 
Material Resource Efficiency  
ICF or SIPS replace wood framing  or other Alternatives to Wood  Incorporating SIP construction requires that stamped plans be  Submit plans or  V 
Framing At least 50 percent of exterior walls or AFT   submitted from a designer.   designs certified by 
    a structural 
engineer prior to 
plan review. 
Inspected in field. 
Advanced Framing Techniques: Use advanced framing techniques  At least two of the options listed must be incorporated to  Advanced framing  M  
to minimize the amount of framing products used waste  receive credit for this checklist item.  techniques must be  Each year the 
generated to construct a building while maintaining the structural  • 24‐inch On‐Center Framing  specified in building  number of 
integrity of the building.   • Resource Efficient Insulated Headers  required 
permit plans with 
  • Trusses with energy heel  options will 
Advanced framing uses up to 25% less wood, increases overall  • Building dimensions designed on 24" or 48"  details called out  increase.  
insulation R‐values by 5 to 10%, and costs less to build.  modules  for framing 
• Stack rafters and joists above studs on 24" centers  carpenters and 
• replace double trimmers with appropriate  verified at site 
engineered building hardware  inspection 
• use of engineered lumber 
• ladder framing at interior wall intersections with 
exterior walls 
• eliminate built up corners that don't allow for any 
insulation everywhere engineering allows 
• value engineer headers and other load bearing 
structural elements 
Reuse Existing Building  Incorporate portions of existing structures in remodel and  Applicant submits  V 
Preserving as much of the existing building as possible extends  addition projects according to the following:   documentation at 
the life‐cycle of the existing housing stock, reduces waste and  Save 50% of exterior walls (external sheathing and framing)  final inspection. 
conserves the embodied energy of the existing building materials 
by reducing the amount of new materials needed, because 
resource extraction, energy use, and pollution due to the 
Draft Checklist_04_13_10
transportation of construction materials are reduced.  
Built in recycle center in kitchen and dedicated space in garage or    Checked during  M 
covered outdoor space for recycling receptors.   plan review and at 
final inspection 
Construction waste management plan is developed and posted at  • "Track and keep a summary log of all construction  Submitted prior to  M 
jobsite and implemented with a target of salvaging a minimum of  waste generated by type, the quantities of each  building permit 
50% of construction waste.  type that were diverted and landfilled, and the total  issuance. Inspected 
  percentage of waste diverted from landfill disposal. 
at the first site visit.  
• A project's construction waste management plan 
should, at a minimum, identify the diversion goals, 
relevant construction debris and materials to be 
diverted, implementation protocols, and parties 
responsible for implementing the plan." 
Individual bins or large crates on site for clean wood, cardboard,    Inspected in the  V 
metal, and other recyclables.  The bins can then be loaded by  field. 
forklift on a truck and hauled to the recycling center.   
Implement recycle program on site for glass, plastic, cans, paper  • "Provide an easily‐accessible dedicated area or areas for  Inspected in the  M 
and cardboard  the collection and storage of materials for recycling for  field. 
the entire building. Materials must include, at a 
minimum: paper, corrugated cardboard, glass, plastics 
and metals." 
Sustainable and Locally Sourced Products
Use of exterior trim products that don't require any paint or  • includes fascia, soffit, door and window surrounds,  Checked at C of O.  V 
stain:    corner trims, band boards etc.  
• Use of exterior doors and windows that don't require any 
paint or stain.  
• Use of exterior finishes that require no maintenance 
includes walls, decking and railings. 
Wood or wood‐based products are  certified to requirements of  Applicant submits from one of the following programs:  Certification  V 
one of the following recognized product programs:  • American Forest Foundation's American Tree Farm System  submitted at of 
• 2 BF (board feet) of certified lumber per square foot (SF) of  • Canadian Standards Association's Sustainable Forest 
management System Standards 
final inspection.  
floor area (2 BF/SF) or 50%  more of dimensional lumber in 
total BF is certified lumber, excluding engineered wood  • Forest Stewardship Council 
• Program for Endorsement of Forest Certification Systems 
products 
• Sustainable Forestry Initiative Program 
 
 
Indoor Air Quality 
All particleboards and MDF’s contain No Added Formaldehyde.     Checked  at C of O  V 
Install an electric (hard wired) or ac/dc CO detector, located    Checked at C of O   
according to manufacturers recommendations 

Draft Checklist_04_13_10
nd
Install HRV or Mechanical Ventilation system   Integrated systems use the furnace fan to bring in outside air  Inspected at  final  V – M (2  year) 
  through a dampered duct, and should be equipped with  mechanical 
controls to regulate air volume.   inspection 
Heat recovery ventilators (HRVs) and energy recovery 
ventilators (ERVs) employ heat exchangers to recover heat.   
The unit must be integrated into the HVAC system. 
Ventilation is particularly appropriate with blower door test 
results of less than 0.35 natural air changes per hour (NACH). 
A timer or humidistat requirement for bathroom fans ensures 
proper run‐time to adequately remove moisture from the 
room.  
Site Disturbance 
Orient longer dimension of the structure to face within 20    Applicant provides  V 
degrees of south  supporting 
  information or a 
solar analysis at 
plan review. 
Construction fencing is on site prior to commencing construction    Check at initial  M 
activities. Fencing shall be placed to limit disturbance to sensitive  inspection.. 
areas and previous non‐disturbed areas not associated with 
landscaping or BE. 
Restrict disturbance to native soils/plants to no more than twice    Applicant provides  V 
the total sq. footage of the proposed building footprint and  supporting 
construction fencing  to ensure areas are not disturbed during  information at plan 
construction activities.  
review and 
inspected at final..  
 
 
 

Draft Checklist_04_13_10