Professional Documents
Culture Documents
Proposal ETP
Proposal ETP
AT
Express Dairy Company Ltd.
- ---------------------------------------
Proposal by:
Headwheel System & Services Pvt. Ltd.
1.1
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
2.0
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.
3.0
Primary Clarifier
i.
ii.
iii.
iv.
v.
vi.
vii.
4.0
Aeration Tank
Assumption: Inlet BOD 140 mg/l
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.
x.
xi.
5.0
i.
ii.
iii.
iv.
v.
6.0
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.
Overall volume - 18 m3
Hydraulic residence time - 0.3days (Or, 7.4 hrs.)
Size of the Aeration Tank 3 (L) X 2 m (B) X 3 m (SWD) [Free board = 0.5 m]
Oxygen requirement & diffuser calculation will be provided latter.
Secondary Clarifier
Design flow rate- 1.5 m3/ hr.
Surface Area 1.02 m2
Diameter 1.15 m
Effective Volume - 2.25 m3
Sludge Loading Rate 52.91 kg/m2/day
Overall volume - 2.75 m3
Hydraulic residence time 1.5 hrs.
SWD - 2.7 m
Free board - 0.5 m
pH 7.5
TSS less than 30 mg/l
BOD - less than 20 mg/l
COD - less than 70 mg/l
O&G less than 1 mg/l