Cairo North I Combined Cycle Project (750

MW)
The facility is designed to include a power block
consisting of two 250 MW (nominal, ISO) combustion
turbine generators (CTGs), each feeding exhaust gases
to its respective heat recovery steam generator
(HRSG).

Steam from the two HRSGs is fed to one 250 MW


(nominal), reheater, condensing steam turbine
generator (STG). The facility's net output is 750 MW
(nominal, ISO).

This output is achieved by burning natural gas in the combustion turbines with no
supplementary firing in the HRSGs. Nitrogen oxides emitted are controlled by dry low nitrogen
oxides combustors.

An inlet air filtration system is included to supply suitable filtered combustion air to the
CTGs.The steam exhausted through the steam turbine is dumped into a once - through
cooling , single – pass, divided water – box condenser. Power is generated at 21 KV in the
CTGs and the STG, stepped - up through main transformers, and fed to the Utility grid via a
220 KV, gas insulated switchgear (GIS) Switchyard . The power plant cooling water is
withdrawn from El Ismailia Canal.    

Technical Details
Cairo North I Combined Cycle Power Plant (750 MW) Main Technical
Parameters
COMPRESSOR TURBINE
MANUFACTURER :                                                          Mitsubishi Heavy Industries.
QUANTITY :                                                                  Two (2).
MODEL :                                                                       M701F.
TYPE :                                                                         Open cycle single shaft.
SPEED :                                                                        3000 rpm
MAXIMUM RATING :                                                        263.3 MW
FUEL :                                                                          Primary: Natural Gas Secondary: No. 2 oil
 
COMPRESSOR
NUMBER OF STAGES :                                                    314 MVA / 15 KV / 50 Hz.
                                                                                   0.85 power factor lag to 0.9 power factor
lead
FREQUENCY :                                                                50 Hz     
TYPE OF COOLING :                                                       Hydrogen cooled.
EXCITATION :                                                                   Static.
 
COMBINED CYCLE
HRSG
MANUFACTURER:                                                           NEM
QUANTITY :                                                                  Two (2)
TYPE :                                                                         Horizontal / Tipple pressures with reheat
MCR FLOW :                                                                  586 Ton/ Hr {HP : 263 HRH: 294 LP:29 }
SUPERHEATER OUTLET :                                                562.50 C & 123.6 Bar
REHEATER OUTLET :                                                      560.70 C& 21.3 Bar
 
STEAM TURBINE
MANUFACTURER :                                                          Hitachi Ltd.
QUANTITY :                                                                  one (1)
POWER :                                                                      259.2 MW
TYPE :                                                                         Indoor single reheat condensing steam.
THROTTLE PRESSURE :                                                  119.5 bars.
THROTTLE TEMPERATURE :                                            559.70 C
 
GENERATOR
RATING :                                                                      326 MVA / 18 KV
                                                                                   0.85 power factor lag- 0.9 power factor lead.
TYPE OF COOLING :                                                       Hydrogen.
 
CONDENSER
QUANTITY :                                                                    One (1)
EFFECTIVE COOLING SURFACE :                                       18.350 m2
COOLING WATER FLOW :                                               54.400 m3 /hr
COOLING WATER TEMPERATURE :                                   270 C
PRESSURE :                                                                   52.4 mm HgA
TUBES :                                                                        316L
 
CIRCULATING WATER PUMPS
QUANTITY :                                                                  Two (2)
TYPE :                                                                         Vertical.
RATING :                                                                      24.228 M3 /Hr & 13.5 M TDH
SUPPLIER :                                                                    KSB
 
PROCUREMENT PACKAGES :                                            16 Packages
 
Cairo North II Combined Cycle Power Plant
(750 MW)
The facility is designed to include a power block
consisting of two 250 MW (nominal, ISO) combustion
turbine generators (CTGs), each feeding exhaust gases
to its respective heat recovery steam generator
(HRSG).

Steam from the two HRSGs is fed to one 250 MW


(nominal), reheat, condensing steam turbine generator
(STG). The facility's net output will be 750 MW
(nominal, ISO).

This output is achieved by burning natural gas in the combustion turbines with no
supplementary firing in the HRSGs. Nitrogen oxides emitted are controlled by dry low nitrogen
oxides combustors.

An inlet air filtration system is included to supply suitable filtered combustion air to the CTGs.
The steam exhausted through the steam turbine is dumped into a once - through cooling,
single – pass, divided water – box condenser. Power is generated at 21 KV in the CTGs and the
STG, stepped - up through main transformers, and fed to the utility grid via a 220 KV, gas
insulated switchgear (GIS) switchyard. The power plant cooling water is withdrawn from El
Ismailia Canal.

Technical Details
CAIRO NORTH II COMBINED CYCLE POWER PLANT (750 MW) Main Technical
Parameters
COMPRESSOR TURBINE
MANUFACTURER :                                                          General Electric.
QUANTITY :                                                                  Two (2).
MODEL :                                                                       9351FA.
TYPE :                                                                         Heavy Duty.
SPEED :                                                                        3000 rpm
MAXIMUM RATING :                                                        256.1 MW
FUEL :                                                                          Primary: Natural Gas Secondary: No. 2 oil
 
COMPRESSOR
NUMBER OF STAGES :                                                    301.3 MVA (max) 15.75 KV 50 Hz.
                                                                                   0.85 power factor lag to 0.9 power factor
lead
FREQUENCY :                                                                50 Hz     
TYPE OF COOLING :                                                       Hydrogen cooled.
EXCITATION :                                                                    Static.
 
COMBINED CYCLE
HRSG
MANUFACTURER:                                                           NEM
QUANTITY :                                                                  Two (2)
TYPE :                                                                         Horizontal / Tipple pressures with reheat
MCR FLOW :                                                                  611 Ton/ Hr {HP : 269 HRH: 314 LP:27 }
SUPERHEATER OUTLET :                                                568.90C & 129.2Bar
REHEATER OUTLET :                                                      560.9 C& 23.29 Bar
 
STEAM TURBINE
MANUFACTURER :                                                          Alstom Power Generation
QUANTITY :                                                                  one (1)
POWER :                                                                      263.4 MW
TYPE :                                                                         Indoor single reheat condensing steam.
THROTTLE PRESSURE :                                                  122.68 bars.
THROTTLE TEMPERATURE :                                            565.840 C
 
GENERATOR
RATING :                                                                      342 MVA / 18 KV
                                                                                   0.85 power factor lag- 0.9 power factor lead.
TYPE OF COOLING :                                                       Hydrogen.
 
CONDENSER
QUANTITY :                                                                    One (1)
EFFECTIVE COOLING SURFACE :                                       18.1040 m2
COOLING WATER FLOW :                                               45.000 m3 /hr
COOLING WATER TEMPERATURE :                                   270 C
PRESSURE :                                                                   52.2 mm HgA
TUBES :                                                                        316L
 
CIRCULATING WATER PUMPS
QUANTITY :                                                                  Two (2)
TYPE :                                                                         Vertical.
RATING :                                                                      24.500 M3 /hr & 14.3 M TDH
SUPPLIER :                                                                    Flowserve.
 
PROCUREMENT PACKAGES :                                            5 Packages
 