Professional Documents
Culture Documents
H 1040 1u-8860
H 1040 1u-8860
H 1040 1u-8860
Pgina 1 de 10
Cerrar SIS
Pantalla anterior
Producto: NO SE HA ESCOGIDO NINGUN EQUIPO
Modelo: NO SE HA ESCOGIDO NINGUN EQUIPO
Configuracin: NO SE HA ESCOGIDO NINGUN EQUIPO
Instruccin Especial
Using the 1U-8860 Large Engine Blowby Pickup Group{0781, 0785}
Nmero de medio -SEHS8984-01
Introduction
The 1U-8860 Large Engine Blowby Pickup Group is an optional pickup for use with the 8T-2701
Blowby/Air Flow Indicator.
It contains a large 38 mm (1.5 in) I.D. pickup which allows it to be used on large engines without increasing
the crankcase pressure.
It is designed to monitor the blowby volume on Caterpillar 3500 and 3600 series engines and the larger
D300 series engines as well as competitive large engines.
The range of this pickup is 94 to 1888 Liters Per Min. (L/min), (200 to 4000 Cubic Feet Per Hour [cfh]).
Due to its all metal construction and large size, it is suitable for permanent installation on engines so blowby
can be continuously monitored, making it useful for dynamometer rooms or marine or gen set installations.
The pickup group can also be used to measure air velocity such as radiator cooling air flow. When connected
to the 8T-2701 Blowby/Air Flow Indicator, it provides a digital display of the blowby value (the volume of
exhaust gas escaping to the crankcase). This blowby value can be used as an indication of engine condition.
However, it should not be used as a stand alone "good/bad" indicator for engine overhaul. It can be used as a
signal that other engine condition indicators such as oil consumption, low power, hard starting, and
excessive fuel consumption should be checked to determine if an engine is in need of maintenance.
The large blowby meter has no moving parts. An ultrasonic sound vortex shedding principle is used to
measure the air flow. This principle makes the pickup reliable and virtually maintenance free.
This unit will be used to replace the smaller 8T-2685 Pickup for the measurement of 3500 series engine
blowby. The 8T-2685 Pickup can be used on these engines, but only for a short duration test since the 50.8
mm (2 in) engine breather tube is reduced to 15.7 mm (.63 in) during the test. The 8T-2701 Blowby/Air
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 2 de 10
Flow Indicator will be used with the larger probe, however a 1U-8863 Conversion Group must be installed
to make it accurate. Refer to Installation of the 1U-8863 Conversion Group.
Refer to Special Instruction SEHS8712 for additional information on the Blowby/Air Flow Indicator.
Adaptability
When used with the 8T-2701 Indicator, the 1U-8860 Pickup can be used to measure the blowby on any
engine within the blowby range of 94 to 1888 L/min (200 to 4000 cfh). This includes the larger Caterpillar
D300 Engines, the 3500 and 3600 series engines.
Smaller D300 and 3500 engines may not have enough blowby at idle or partial load to give a reading when
they are in good condition. Therefore, the indicator display will read zero until the engine is loaded.
Optional Items
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 3 de 10
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 4 de 10
Storage Temperature:
Pickup: -40 to 232C (-40 to 450F)
Probe Size:
Length: 382 mm (15.0 in)
Outside Dia.: 50.8 mm (2.00 in)
Inside Dia.: 38.1 mm (1.50 in)
Width: 113 mm (4.5 in)
Height: 130 mm (5.2 in)
1U-8860 Group Case Size:
432 330 114 mm (17.0 13.0 4.5 in)
Weight:
1U-8860 Group: 6.1 kg (13.50 lb)
1U-8861 Pickup only: 3.0 kg (6.60 lb)
Power:
Provided by the PICKUP connector on the 8T-2701
Blowby/Air Flow Indicator.
A 1U-8863 Blowby V1.20 Conversion Group integrated circuit (1) is packaged with the 1U-8860 Large
Engine Blowby Pickup Group. This integrated circuit contains the program which makes the large pickup
readings accurate.
The integrated circuit must be installed in the 8T-2701 Blowby/Air Flow indicator you will be using. Once
this is completed, the 8T-2701 indicator will be accurate for both the Large Blowby Pickup and the Small
Blowby Pickup.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 5 de 10
The 1U-8863 Conversion Group (1) is the small plastic box packed in the front storage area of the large
pickup case. Open the small plastic case to identify the conversion group integrated circuit memory, but DO
NOT remove it at this time. It should be marked "1U-8863 Blowby Gp. V1.20".
Use the following instructions to install the integrated circuit in the 8T-2701 Indicator which will be used
with the large blowby probe.
NOTICE
The 1U-8863 conversion group integrated circuit memory may be
damaged by static electricity discharge. DO NOT handle in a carpeted,
dry, area where static electricity may be present.
Installation Instructions
1. Remove six screws (2) from the rear cover and remove cover (3).
2. Remove battery (4) from the holder. Use a small screwdriver to pry the old Blowby V1.19 integrated
circuit memory from its socket and remove.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 6 de 10
1. Locate the crankcase breather(s) (1) on the engine. The engine may have more than one crankcase
breather. If there is more than one, the blowby coming from all of them must be measured at the same time.
Most engine installations will already have the breathers connected together with tubing (2). The pickup can
then be installed after the point where they come together (3). If they are not already connected together,
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 7 de 10
they may be connected with hoses or by temporarily plugging all but one breather for a short period during a
temporary test.
If the pickup installation is to be permanent, the breathers must be connected together with adequate sized
tubing to prevent excessive crankcase pressure.
2. The 1U-8861 Large Engine Blowby Pickup (4) can be installed directly into the breather flexible fitting
(5) used on some Caterpillar engines, provided the fitting is the correct size. This installation is suitable for a
temporary check of blowby.
Be sure to install the pickup with the arrow pointing away from the engine in the direction of blowby air
flow. Secure the pickup with a hose clamp. Since the pickup is heavy, it may be necessary to secure the
pickup to keep it from moving during the operation.
3. For installation to the end of a metal blowby tube, a rubber hose (6) is included in the group. It will fit
most tubes which have close to a 50 mm (2.0 in) diameter. Secure the hose with clamps (7).
4. Attach an 8T-5297 Cable or a 6V2198 Cable to the connector on the pickup and the other end to the
pickup connector on the 8T-2701 Indicator. This completes the installation.
Measuring Blowby
NOTE: The large blowby pickup is sensitive to excessive high frequency noise and air currents entering the
open end of the pickup. To prevent inaccurate readings, keep the pickup outlet as far away from the engine
turbocharger as possible, and away from the fan or any wind blowing past the open end of the pickup.
If the pickup must be placed close to the engine or in the air stream, use a length of rubber hose to extend the
outlet away from the source of high frequency noise or air stream.
1. Refer to Special Instruction SEHS8712 for instructions on how to operate the 8T-2701 Indicator.
2. Start and run the engine until normal operating temperature is reached.
3. Blowby readings should be taken with the engine at full rpm. Readings may be taken at no load or full
load, but the engine must be loaded to measure the maximum blowby output of the engine
On smaller 3500 engines the indicator may show zero until the engine is loaded since the blowby is below
the minimum rating of the pickup.
Analyzing Results
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 8 de 10
NOTE: Blowby should be used as a guide only to indicate engine condition and not as an absolute good/bad
indicator. DO NOT use the blowby data alone to determine if the engine should be rebuilt. If the blowby
value is high, check the other indicators, such as oil consumption, low power, etc.
Approximate blowby rates for Caterpillar large engines are shown in the chart. The values listed are the
typical maximum rates for an engine in new condition. These values are typical ONLY and not absolute.
NOTE: Additional valves can be found in the Technical Marketing Information.
It is recommended to always check the blowby by the same method for better comparison of future tests.
Record the blowby rate and the load on the engine during the test for later reference.
It is suggested that new engines initially be checked for blowby and thereafter during all maintenance
checks.
As the engine rings and cylinder walls wear, the blowby will gradually increase. The blowby on a worn
engine will be considerably higher than for a new engine. By keeping a record of the results, a gradual
increase in the amount of blowby will be noted until the amount of blowby has become excessive.
Usually, high oil consumption and other problems associated with high blowby will not be experienced until
the blowby is considerably higher than the values shown in the chart. (Approximately two times or more.)
After a new engine is used for a short time, the blowby can decrease as the rings are seated. Also, a newly
rebuilt engine can have a high blowby rate due to the rings not being properly seated, or worn parts which
were not changed, ie. valve guides.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup G... Pgina 9 de 10
The components required for the following test are the 8T-2701 Indicator, the 8T-5297 or 6V-2198 Cable
and the 1U-8861 Pickup.
1. Connect the 1U-8861 Pickup to the indicator with the cable.
2. Press the ON switch, then the FT/MIN, ACTUAL, and the NORM RATE switches. An arrow should
appear on the display and point to the same name as the switch pressed. The display should read zero.
3. Blow into the pickup in the direction of the arrow on the side. Observe the reading on the indicator
display. It should read approximately 862 to 1439 FT/MIN, depending on how hard you blow.
4. Press the M/MIN switch and the arrow should point to M/MIN. Blow into the pickup again and the
indicator should read approximately 262 to 438 M/MIN, depending on how hard you blow.
5. Press the FT3/HR switch and the arrow should point to the FT3/HR. Blow into the pickup again and the
indicator should read approximately 635 to 1059 FT3/HR, depending on how hard you blow.
6. Press the L/MIN switch and the arrow should point to L/MIN. Blow into the pickup again and the
indicator should read approximately 300 to 500 L/MIN depending on how hard you blow.
7. Press the OFF switch and the display should be blank.
This completes the test for the 1U-8863 pickup.
Repair Information
If the large blowby probe does not operate correctly, use the procedure, "Checking Operations of the
Pickup", to determine if the problem is in the pickup or the indicator.
If the pickup is found to be faulty, contact Caterpillar Service Technology Group for service or warranty
information.
Units less than one year old will be repaired under warranty (except for abuse). Cost of out of warranty
repairs will be charged to the owner.
Phone - Toll Free Numbers
Outside Illinois ... 1-800-542-8665
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009
Bsqueda del medio - SEHS8984 - Using the 1U-8860 Large Engine Blowby Pickup... Pgina 10 de 10
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 02-02-2009