HExcle

You might also like

Download as txt, pdf, or txt
Download as txt, pdf, or txt
You are on page 1of 5

Site level: can apply grep to all commands (| grep "yyyy-mm-dd")(| grep DXU0040)

amos site#
hget rbs rbslocalcell|localcellid|maxDlPowerCapability
te log read | grep ERROR (gives log on site with errors)
readclock
hget . fq|cellid (to check freq of sectors)
get . enna DL attuenation)
get . internal (gives if tma is powered internally or externally)
get tma
get tma dl (gives TMA DL attenuation)
get tma ul (gives TMA UL attenuation)
lst aal (aal congestion)
cabx | grep RAX (Shows all RAX boards installed in the NodeB)
st aux (Check the Status of Auxillary Units, this will show whether you are deal
ing with an RRU or RU/FUs. With RRU, the interface card is the OBIF and the stan
dard RU/FUs utilise the RUIF)
st ruif/st obif (When the interface hardware is an RUIF, a Status Check of the R
UIF will provide the slot position you will need to allow for polling the board,
If aux shows that the Site has RRUs, then command line will be st obif, Usually
slot convention falls into: macro=12, RRU/Combo Cab=9 and micro=6)
lh ru fui get devstat (gives current, volt, Ulgain, sensitivity=49 means supervi
sion on and txfreq)
lh ru fui get vswr (gives vswr- shud be in 12 to 24 dB range, higher is better 2
0dB is good)
lh ru fui get faults
lhsh 001200/port_4_dev_12 fui get vswr or devstat (gives device status and vswr
for respective port# and dev#) (dualband tma if current ~280mA)
lhsh 001200 ps | grep -i hang (hanging board)
lhsh 001200 ps | grep FU (will give the remote RUIF board for all processes grou
ped by FU- first row will usually be carrier 1 alpha sector and so on)
st rax (checking individual borads and their slot numbers and operational state)
st tx (checking individual borads and their slot numbers and operational state)
st cbu (checking individual borads and their slot numbers and operational state)
lhsh 000slot#00 te log read (gives logs on that particular slot-000600 is slot 6
)
pgets (giv during live monitoring, shows all counters related to power utilizati
on)
lget utrancell=CNU1732 frequencyrelationtype 0 (gives all the INTRA defined nbrs
for a site)
lget utrancell=CNU1732 frequencyrelationtype 1 (gives all the INTER defined nbrs
for a site)
lget cnu3229A frequencyrel (same as above)
get utrancell=DXU0040 maximumtransmissionpower
get utrancell=DXU0040 hoType
get utrancell=cnu1970 adminis (gives unlocked)
get utrancell=cnu1970 cellreserve (gived reserved)
get UTRANcell=cnu1970 qrxlevmin|usedFreqThresh2dEcno|sIntersearch|cpich|usedFreq
Thresh2dRscp|MaximumTransmissionPower (counters can ce clubbed, can check any po
ssible counters)
lki (will show consistent and in-consistent Iub links all)
h lki (help on lki)
str | grep DXU5850A (Shows the status of the cell DXU5850A)
get utrancell=HXU0470 scr (scrambling code)
Pmx -m 2 aal2ap=b265 pmUnSuccOutConnsRemoteQosClass (getting Iub congestion -rem
ote last 2 hours)

get PRSJU0033 rbsid (gives the bnum of the site)


get utrancel
pmx utrancell=TXU0275 pmtotnorrcconnect(req$|reqsuccess)|pmNoRabEstablishSuccess
Speech|pmNoRabEstablishAttemptSpeech -m 0.25 -a
pmx TXU0237|TXV4237 pmnosystemrabreleasespeech|pmNoSysRelSpeechSoHo|pmNoSysRelSp
eechNeighbr|pmNoSysRelSpeechUlSynch -m 0.25 -a
pmx -m 2 cell=TXU61188 pmCellDowntime -to check downtime

lget . defaulthotype
pmom . counter name
mom . Cpich ()
llog(restart info)
lhsh 000100 te log read | grep -i err
lhsh 000100 te log read | grep error
lhsh 000100 te log read | grep synchronizationFailure
pmxh . pmCapAllocIubHsLimitingRatioSpi03|pmHsDataFramesLostSpi03 -m 5-Transport
issues

pmx UtranCell=HXU2531 pmNoFailedAfterAdm -m 48 -a (Failed after admission)


get . outputpower
get externalTMA
lget utrancell=HXU4182 hsiflsmarginusers|hsiflsthreshusers|iflsmode|pathlossthre
shold
lget coveragerelation ref
lget utrancell=HXU25551 coveragerelation
get UtranCell=HXU25551,CoverageRelation
lh rax ter 3600
lh tx ter 3600
external defined or not
AUSUTXNIRNC003> lget HXV43777 external
RL attempts from OSS
pmx UtranCell=HXU0043 pmRlAddAttemptsBestCellSpeech -m 240

Hardware:
Main RBS Cabinet for macrocells contains: FU, RU, RUIF

for drpdue to others


board errors
CBU errors
RSSI
overshooting
pilot pollution in the area
vswr
transport issues
SC collision
IFHO failures

NON HS
ok so you have total power and than you have power used each cell for cs traffic
. the ideally is to keep that power as low as possible. and whateever the power
used on cs traffic rest are for the hs. the graph that shows the power utilizati
on for yoru cs are called the non-hs power utilization
you look into this to make judgement if you cell is heavily congested or not. if
it is not than you can cahnge your admission parameters cause many cases they a
re set to very high

Date: 2013-07-19
Object
Counter
15:00 16:00 17:00
UtranCell=HXU52511 pmNoFailedRabEstAttemptLackDlHw
0
0
0
UtranCell=HXU52511 pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
UtranCell=HXU52512 pmNoFailedRabEstAttemptLackDlHw
0
0
0
UtranCell=HXU52512 pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
UtranCell=HXU52513 pmNoFailedRabEstAttemptLackDlHw
0
0
0
UtranCell=HXU52513 pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
UtranCell=HXU52514 pmNoFailedRabEstAttemptLackDlHw
10
6
0
UtranCell=HXledRabEstAttemptLackDlHwBest
0
0
0
UtranCell=HXU5251C pmNoFailedRabEstAttemptLackDlHw
0
0
0
UtranCell=HXU5251C pmNoFailedRabEstAttemptLackDlHwBest
0
0
0
UtranCell=HXV62511 pmNoFailedRabEstAttemptLackDlHw
9
6
0
UtranCell=HXV62511 pmNoFailedRabEstAttemptLackDlHwBest
9
8
0
UtranCell=HXV62512 pmNoFailedRabEstAttemptLackDlHw
15
36
0
UtranCell=HXV62512 pmNoFailedRabEstAttemptLackDlHwBest
14
32
0
UtranCell=HXV62513 pmNoFailedRabEstAttemptLackDlHw
8
6
0
UtranCell=HXV62513 pmNoFailedRabEstAttemptLackDlHwBest
6
6

********************************************************************************
****************************************************
UtranCell hsdschInactivityTimerCpc long
----------------------------------------------------------------------------------------------------------------------------------Time after which a CPC activated connection with low throughput is downswitched
from CELL_DCH to CELL_FACH. This parameter is used instead of hsdschInactivityTi
mer for CPC activated connections.
Special value
-1: corresponding parameter on MOC ChannelSwitching is used
Resolution: 5
Dependenciesmeter on MOC ChannelSwitching is used
7200: only for internal use.

Dependencies: Used if the feature InactivityTimerCellConfig is activated and if


the parameter value is <> -1. If not the corresponding parameter on MOC ChannelS
witching is used.
Feature: InactivityTimerCellConfig
Change takes effect: New connections
Unit: s
Range: -1, 1 to 255, 7200, Default=-1
********************************************************************************
****************************************************

for parameters
mom MO parametername
for counters
pmom MO countername
HOW TO MOBATCH
mobatch sitelist.txt 'lt all;get . rbslocalcell; get . localcellid;get . maxDlPo
werCapability' Parameters
in some cases when you need something but that parameter needs pass (like cabx)
you need to add a password in the sitelist
CVU2066 password=rbs2066
CNU6108 password=rbs6108
CVU0407 password=rbs0407
CVU4366 password=rbs4366
egrep -i (optional) 'maxdl|localcellid|rbs' ./*.log > dump.txt
for multiple lookups in Parameter CR
VLOOKUP(B2,Sheet1!A:V,MATCH(D2,Sheet1!A$1:V$1,0),0)

lgaes -s 20130901-alarms,event,crashes
llog
lgd-downtime
st t1
pmr -m 3 -r 25-report no 25 to show the packetloss
lh rax te log read | grep -i error-RAX check
lh tx te log read | grep -i error-Tx Check
s+

HW/SW load
MOC
Parameter
AT&T Gold Standard
Initial Value
(Only to be used by Ericsson when building a new site)
W12B
Eul=1900
pathlossThresholdEulTti2
95..170 120
W12B
Eul=850 pathlossThresholdEulTti2
95..170 95
W12B
Eul
threshEulTti2Ecno
-8

AAL2 BO
Jose A

pmx HXU5216|HXV6216 pmOutHsIflsHhoAtt|pmOutHsIflsHhoSucc -m 2


for Eutranfreq- get HXU2547.*,eutranfreqrelation Id

You might also like