Professional Documents
Culture Documents
KSB Amacan K Literature
KSB Amacan K Literature
Amacan K
50 Hz
Legal information/Copyright
Type Series Booklet Amacan K
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a
third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
KSB Aktiengesellschaft, Frankenthal 19.09.2013
Contents
Contents
Water: Water Transport .................................................................................................................................... 4
Submersible Pump in Discharge Tube ........................................................................................................................... 4
Amacan K ................................................................................................................................................................... 4
Main applications ................................................................................................................................................ 4
Fluids handled ...................................................................................................................................................... 4
Operating data ....................................................................................................................................................4
Designation .......................................................................................................................................................... 4
Design details ....................................................................................................................................................... 4
Materials ..............................................................................................................................................................5
Coating and preservation ...................................................................................................................................5
Product advantages / customer benefits ............................................................................................................ 5
Acceptance tests / Warranties ............................................................................................................................. 5
Selection information .......................................................................................................................................... 5
Overview of product features / selection tables ................................................................................................ 6
Table of fluids handled .................................................................................................................................6
Overview of product features ....................................................................................................................... 7
Pump/motor combinations ............................................................................................................................ 8
On all enquiries/orders please specify ................................................................................................................ 9
Material variants ................................................................................................................................................ 10
Related documents ............................................................................................................................................ 10
Selection chart ...................................................................................................................................................11
Amacan K, n = 1450 / 960 / 725 / 580 rpm ..................................................................................................11
Characteristic curves .......................................................................................................................................... 12
n = 1450 rpm ................................................................................................................................................ 12
n = 960 rpm .................................................................................................................................................. 13
n = 725 rpm .................................................................................................................................................. 23
n = 580 rpm .................................................................................................................................................. 28
Dimensions ......................................................................................................................................................... 29
UG/XG motors (700-324 to 800-401) ........................................................................................................... 29
UNG/XNG motors (700-330, 800-400, 1000-420 to 1200-630) ................................................................... 31
Types of installation ..........................................................................................................................................33
Scope of supply .................................................................................................................................................. 33
Accessories ......................................................................................................................................................... 34
Pump with support rope and turnbuckle in the discharge tube ..............................................................34
Discharge tube cover with cable gland ......................................................................................................35
General assembly drawings with list of components ...................................................................................... 37
Amacan K 700 - 324 ... 800 - 401, motor version: UG/XG ..........................................................................37
Amacan K 800 - 330 ... 800 - 401, motor version: UG/XG ..........................................................................38
Amacan K 700 - 330 ... 1200 - 630, motor version: UNG/XNG ...................................................................39
Code
800
400
60
6
Amacan K
UN
Description
Nominal diameter of the discharge tube [mm]
Nominal impeller diameter [mm]
Motor size
Number of motor poles
4 4-pole
6 6-pole
8 8-pole
10 10-pole
Motor version ( Page 7)
U Without explosion protection, standard
(sizes 700-371 ... 800-401)
X Explosion protection to ATEX
(sizes 700-371 ... 800-401)
UN Without explosion protection, standard
(sizes 700-330, 800-400,
1000-420 ... 1200-630)
XN Explosion protection to ATEX
(sizes 700-330, 800-400,
1000-420 ... 1200-630)
Material variant ( Page 10)
G Impeller made of grey cast iron, standard
variant
G1 Like G, with impeller made of duplex stainless steel
Design details
Design
Main applications
Irrigation and drainage pumping stations
Stormwater pumping stations
Water pollution and flood control
Fluids handled
Drive
Waste water
Sludge
Surface water
Stormwater
Grey water
Shaft seal
Two bi-directional mechanical seals in tandem arrangement, with liquid reservoir
Operating data
Operating properties
Characteristic
Flow rate
Head
Motor rating
Fluid temperature
Enclosure
Q
H
P2
t
Value
Up to 1500 l/s
Up to 30 m
Up to 320 kW
Up to +40 C
IP 68 to IEC 60034-5; explosion
protection to ATEX II 2G T3
available
Designation
Example: Amacan K 800-400 / 60 6 UN G
Key to the designation
Code
Amacan
K
Description
Type series
Impeller type, e.g. K = channel impeller
Amacan K
Impeller type
Closed multichannel impeller
(impeller type K)
Bearings
Grease-packed rolling element bearings
Selection information
Information for pump selection
Overview of materials
Description
Pump casing
Motor housing
Shaft
Impeller
Casing wear ring
Screws, bolts and nuts
Material
EN-GJL-250 (JL 1040)
EN-GJL-250 (JL 1040)
C45N/1.4021
EN-GJL-250 (JL 1040) / 1.4517
(duplex stainless steel)
EN-GJL-250 (JL 1040) / VG 434
Stainless steel
Special coating
Available on request (extra charge and a longer delivery
period apply).
Acceptance tests
Acceptance tests to ISO/DIN or comparable standards are
available against a surcharge.
Warranties
Quality is assured by means of an audited and certified
quality assurance system to DIN EN ISO 9001.
1)
[kW]
Mains operation
< 30
> 30
10 %
5%
Determine the min. water level t1min (see diagram in general arrangement drawing):
The min. water level t1min is the water level required in the
pump's suction chamber to ensure:
that the liquid cover above the hydraulic system (impeller)
is sufficient (shown in diagram depending on pump size)
that the pump does not draw in air-entraining vortices
(shown in diagram depending on flow rate)
that no cavitation occurs in the hydraulic system (check
against the NPSHrequired value indicated in the technical literature). The following conditions must be met:
NPSHavailable > NPSHrequired + safety allowance
NPSHavailable = 10.0 + (t1 - t3 - h7/2)
Safety allowance:
up to Qopt 0.5 m
greater than Qopt 1.0 m
Head (H)
The total pump head is composed as follows:
H = Hgeo + HV
Hgeo (static head)
Without discharge elbow Difference between suctionside water level and overflow edge
With discharge elbow Difference between suction-side
and discharge-side water level
HV (losses in the system)
Starting 0.5 m downstream of the pump: e.g. pipe friction,
elbow, swing check valve, etc.
If larger reserves are stipulated by local regulations or are required to compensate for uncertain factors in system calculations, these larger reserves must be provided.
Amacan K
Comments, recommendations
Free passage > any solids contained, possibly pre-cleaned via a screen or weir
2)
Fluids to be pumped which are not listed in this table usually require higher-grade materials. Contact KSB.
Amacan K
Motor version
U/X
Motor size
4-pole
6-pole
8-pole
10-pole
Shaft material
Shaft
Shaft protecting sleeve
Bearings
Explosion protection
Version U...
Version X...
Motor
Starting method
Voltage
Cooling
Submergence
Power cable
Type
Length
Cable entry
Sealing elements
Elastomer seals
Shaft seal
Monitoring equipment
Winding temperature, version U...
Winding temperature, version X...
Bearing temperature
Motor leakage
Mechanical seal leakage
Vibration sensor
Coating
Installation
Maximum temperature of fluid handled
Tests/inspections
Hydraulic system
General
20 6
10 8, 17 8
-
29 4
26 6
21 8
-
UN/XN
35 4 ... 65 4
32 6 ... 50 6
26 8
-
1.4021
1.4021
1.4021
Grease-packed rolling element bearings
sealed for life
80 4
60 6
50 8
-
80 6 ... 320 6
75 8 ... 150 8
40 10 ... 75 10
C 45 N
1.4021
1.4021
1.4021
Pump end: regreasable rolling element
bearing
Drive end: grease-packed rolling element
bearing sealed for life
Not explosion-proof
ATEX II 2G T3
DOL or star-delta (690 V only DOL)
400 V3)
Cooled by surrounding fluid
30 m max.
See table "Overview of power cables"
10 m4)
Absolutely watertight
Nitrile butadiene rubber NBR5)
Bellows-type mechanical seal6)
Temperature switch (bimetal) in the winding
Temperature switch (bimetal) in the winding, plus PTC for explosion protection
-7)
Pump-end PT1007)
Electrode monitoring the winding for leak- Electrode monitoring the winding and conage
nection space for leakage
Float switch in leakage area
-8)
Environmentally friendly KSB standard coating, colour RAL 50029)
( Page 33)
40 C
3)
4)
5)
6)
7)
8)
9)
10)
S1BN8-F
rubber-sheathed cable
Standard
1000 V
-
S07RC4N8-F
rubber-sheathed cable
Optional
750 V
Amacan K
S1BN8-F
rubber-sheathed cable
S07RC4N8-F
rubber-sheathed cable
EPR11)
90 C
EPR11)
90 C
Insulation material
Max. continuous temperature of insulation
For permanent immersion in waste water to DIN VDE 0282-16/HD22.16
Pump/motor combinations
Overview of pump/motor combinations
Size
Motors
1
2
3
11)
65 4
80 4
20 6
26 6
32 6
40 6
50 6
60 6
80 6
100 6
120 6
140 6
165 6
190 6
225 6
260 6
320 6
10 8
17 8
21 8
26 8
90 8
110 8
130 8
150 8
40 10
60 10
75 10
10-pole
50 4
8-pole
35 4
K 700-371
K 700-324
K 700-330
K 800-330
K 800-370
K 800-400
K 800-401
K 1000-420
K 1000-421
K 1000-500
K 1200-630
6-pole
29 4
4-pole
1
-
2
-
2
-
2
-
3
-
1
1
1
1
-
1
1
1
1
1
1
-
2
2
2
-
2
2
2
-
2
2
-
3
3
3
-
3
3
3
-
3
3
3
-
3
-
3
-
3
-
3
3
1
1
1
1
-
1
1
1
-
1
1
-
2
2
-
General assembly drawing Amacan K 700 - 324 ... 800 - 401, motor version: UG/XG ( Page 37)
General assembly drawing Amacan K 800 - 330 ... 800 - 401, motor version: UG/XG ( Page 38)
General assembly drawing Amacan K 700 - 330 ... 1200-630, motor version: UNG/XNG ( Page 39)
Amacan K
The support rope is an accessory and can be supplied with additional lifting rings and a support spacer as an option. ( Page
34) The standard design is supplied without intermediate lifting ring(s).
Amacan K
Description
101
163
230
350 / 330
412
Pump casing
Discharge cover
Impeller
Bearing housing / bearing bracket
O-ring
433
502
525
571
811
812
818
834
G112)
Related documents
General Arrangement Drawings 1579.39
Motor Data Booklet 1579.53
Planning Information 0118.55
12)
13)
14)
15)
16)
17)
18)
19)
10
Amacan K
400
Q [U S.gpm] 1000
500
2000
Q [IM.gpm] 1000
3000
2000
4000 5000
3000
10000
4000 5000
20000
10000
20000
100
30
20
K1000--500 6p
50
K800-- 370 6p
10
K700/800 --330 4p
40
K1000-- 420 6p
K1200--630 6p
30
K700--371 6p
K800-- 400 6p
K700--330 6p
K700--324 6p
K1000--421 6p
K1200--630 8p
K700--371 8p
20
10
K700-- 324 8p
K1200--630 10p
H [ft]
K800--400 8p
H
[m]
1
100
30
200
Q [m3/h]
40
50
300
Q [l/s]
400
100
500
1000
200
300
2000
400
500
3000
4000 5000
6000
1000
Amacan K
11
0
34
2000
Q [US.gpm]
2000
4000
6000
Q [IM.gpm]
4000
6000
100
30
Qmin
60
65
20
60
H [ft]
70
75
65
80
75
H [m]
78
60
10
[%]
78
70
65
65
70
70
65
100
600
Q [l/s]
800
60
1000
200
75
75
75
71.7
78
78
76.5
70
80
80.4
80
75
60
50
80.7
80
70
70
65
70
65
60
300/296
60
287/266
270/242
1200
65
1400
300
60
326
1600
400
60
80
P [kW]
40
326
300/296
20
P [hp]
287/266
270/242
600
800
1000
1200
10
1400
1600
K43064
Free passage
70 mm
20)
12
50
Rated power P2
[kW]
27,0
38,0
48,0
62,0
80,0
Mass moment of
inertia J [kgm2]
0,46
0,57
0,6
0,65
0,81
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
0
15
1000
3000
4000
Q [IM.gpm] 2000
5000
3000
4000
H [m]
40
Qmin
10
60
60
60
65
H [ft]
70
75
65
78
70
80.5
75
65
81.4
78
70
75
[%]
78
78
78
22
200
Q [m 3/h]
400
600
100
Q [l/s]
800
70
75
65
70
75
70
75
78
79.2
20
80.5
80
324
310/295
290/262
65
65
1000
200
1200
300
20
P [kW]
15
324
20
P [hp]
310/295
10
290/262
200 Q [m 3/h]
400
600
800
1000
10
1200
K42183
Free passage
70 mm
21)
Rated power P2
[kW]
18,0
24,0
Mass moment of
inertia J [kgm2]
0,55
0,58
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
13
0
15
1000 Q [US.gpm]
1000
2000
3000
Q [IM.gpm]
4000
2000
3000
4000
40
Qmin
10
60
60
H [m]
H [ft]
65
70
[%]
75
65
78
70
75
60
65
5
60
78
79.4
75.5
70.6
70
65
18
200 Q [m3/h]
400
100
60
70
65
70
65
65
60
60
326
300/296
287/266
270/242
600
Q [l/s]
75
75
75
70
78
78
75
65
70
20
79.7
70
60
800
1000
200
300
20
P [kW]
326
10
300/296
287/266
270/242
200 Q [m3/h]
400
600
800
1000
K42186
Free passage
70 mm
22)
14
Rated power P2
[kW]
18,0
24,0
Mass moment of
inertia J [kgm2]
0,55
0,58
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
P [hp]
10
0
15
1000
[US.gpm] 2000
1000
3000
[IM.gpm]
4000
2000
5000
3000
4000
40
Qmin
60
10
65
60
60
60
H [m]
60
60
70
65
70
65
65
65
[%]
75
70
70
76
75
70
76.3
74.3
74.6
76
75.8
75
65
H [ft]
20
75
75.4
75
75
70
70
70
70
65
60
278
19
200
Q [m 3/h] 400
600
100
Q [l/s]
297
65
65
65
65
65
60
70
70
60
60
60
336
312 323
60
800
350
0
1200
1000
200
300
15
20
P [kW]
350
P [hp]
10
336
323
5
3
278
200
Q [m 3/h]
400
600
297
10
312
800
1000
1200
K42171/1
Free passage
105 mm
23)
Rated power P2
[kW]
18,0
24,0
Mass moment of
inertia J [kgm2]
0,65
0,68
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
15
0
20
1000
3000
4000
Q [IM.gpm] 2000
5000
3000
4000
60
Qmin
15
65
H [m]
65
70
H [ft]
75
80
70
75
10
65
65
[%]
78
70
78
40
81.8
80
81.1
75
70
78
75
76.4
78.3
80
78
80
78
75
78
75
75
70
65
300/290 318/310
30
200 Q [m 3/h]
400
600
100
Q [l/s]
800
370
70
70
65
20
70
75
1000
200
340
1200
300
40
P [kW]
370
20
340
10
300/290
600
800
318/310
1000
1200
K43124/1
Free passage
85 mm
24)
16
Rated power P2
[kW]
18,0
24,0
30,0
40,0
Mass moment of
inertia J [kgm2]
0,6
0,63
0,84
0,92
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
P [hp]
20
0
24
20
2000
Q [US.gpm] 4000
2000
6000
Q [IM.gpm]
4000
6000
8000
60
60
60
H [m]
66
66
60
60
70
66
60
10
76
70
79
73
70
76
66
79
70
79
80.1
77.9
73
66
40
80.7
76
73
76
76
73
71.4
70
73
79
74.2
H [ft]
[%]
73
70
55
10000
Qmin
15
8000
70
66
73
66
355/330
332/300
500
Q [m 3/h]
1000
200
76
70
73
20
66
70
388/377
376/358
1500
Q [l/s]
70
408
2000
400
600
408
40
P [hp]
P [kW]
388/377
376/358
40
355/330
20
332/300
10
60
500
Q [m 3/h]
1000
1500
20
2000
K43125
Free passage
100 mm
25)
Rated power P2
[kW]
24,0
30,0
40,0
48,0
60,0
Mass moment of
inertia J [kgm2]
0,88
1,09
1,17
1,26
1,41
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
17
0
20
2000
Q [US.gpm]
2000
4000
6000
Q [IM.gpm]
8000
4000
6000
60
H [ft]
15
Qmin
60
H [m]
60
65
69
65
69
10
60
60
72
40
74
72
[%]
76
74
65
69
65
72
76
75.1
69
76.4
72
73.5
44
Q [m 3/h] 400
600
800
1000
65
200
1200
Q [l/s]
69
69
69
367/331
20
72
72
72
69
74
74
72.5
72
65
65
384/350
1400
1600
398/371
1800
408/393
2000
400
40
30
40
408/393
P [kW]
398/371
20
384/350
367/331
10
Q [m 3/h]
400
600
800
1000
1200
1400
20
1600
1800
2000
K43126
Free passage
135 mm
26)
18
Rated power P2
[kW]
24,0
30,0
40,0
48,0
Mass moment of
inertia J [kgm2]
0,88
1,09
1,17
1,26
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
P [hp]
0
28
6000
8000
Q [IM.gpm] 4000
10000
6000
8000
25
80
Qmin
60
20
70
60
60
15
10
77
75
70
60
90
500
Q [m 3/h]
1000
200
1500
Q [l/s]
77
77
75.4
69.9
40
76.9
75
72.6
H [ft]
78.7
78
70
60
[%]
77
75
70
60
H [m]
60
75
70
75
75
75
75
450/435
430/416
70
420/395
403/376
387/355
370/336
2000
20
2500
400
600
80
100
P [kW]
450/435
60
430/416
P [hp]
420/395
403/376
40
25
50
387/355
370/336
500
Q [m 3/h]
1000
1500
2000
2500
K43127
Free passage
100 mm
27)
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
19
0
25
6000
8000
Q [IM.gpm] 4000
10000
6000
12000
8000
10000
80
20
Qmin
60
55
60
65
15
55
73
60
65
H [m]
55
10
H [ft]
68 70
68
[%]
75
70
60
65
76.3
73
70
68
65
55
80
396/360
500
Q [m 3/h] 1000
200
73
69
58.2
75
73
55
Q [l/s]
76
73.6
68
40
76
1500
416/385
2000
400
20
450/433
434/410
68
2500
600
800
100
P [hp]
60
450/433
P [kW]
434/410
40
50
416/385
396/360
20
0
500
Q [m 3/h]
1000
1500
2000
2500
K43128
Free passage
140 mm
28)
20
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
0
40
5000
Q [IM.gpm]
Q [US.gpm]
4000
6000
10000
15000
8000
10000
12000
14000
Qmin
30
100
50
60
69
H [m]
75
[%]
79
82
50
60
20
69
83.6
75
79
50
60
50
H [ft]
82
79.9
69
75
76.4
60
69
10
75
170
69
75
72.7
69
69
69
50
79
79
75
460
508
438/430
416/393
200
Q [l/s]
1500
400
2000
2500
600
3000
3500
800
4000
1000
150
200
P [kW]
508
460
100
438/430
P [hp]
100
416/393
50
1500
2000
2500
3000
3500
4000
K43129/1
Free passage
110 mm
29)
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
21
0
46
15000
20000
Q [IM.gpm] 10000
25000
15000
20000
150
40
Qmin
50
30
60
50
60
50
50
20
60
60
50
60
H [m]
100
70
75
70
[%]
78
70
75
70
75
75
78
81
78
80.9
78
70
74
79.4
78.1
78
82
81
70
75
75
70
70
520/450
340
500
3000
Q [l/s]
4000
75
70
70
582/565
565/540
550/512
540/490
60
60
50
78
78
78
75
10
H [ft]
5000
1000
6000
1500
300
400
P [kW]
200
582/565
565/540
550/512
540/490
100
520/450
3000
4000
5000
6000
K42190
Free passage
133 mm
30)
22
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
P [hp]
200
0
9
1000
Q [US.gpm]
1000
2000
3000
Q [IM.gpm]
2000
3000
Qmin
6
60
60
60
H [m]
70
65
60
60
20
65
60
70
65
70
65
[%]
73
70
65
73
70
74.7
73
65
73
73.4
74.2
60
70
Q [m 3/h]
200
50
300
Q [l/s]
400
70
65
65
60
60
500
100
70
65
278
70
73
70
65
10
73
73
73
68.8
H [ft]
75.2
73
297
600
150
65
65
60
312
60
60
336
323
700
350
0
900
800
200
250
8
10
6
350
P [kW]
P [hp]
336
323
297
312
278
Q [m /h]
3
200
300
400
500
600
700
800
900
K42172/1
Free passage
105 mm
31)
Rated power P2
[kW]
10,0
Mass moment of
inertia J [kgm2]
0,64
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
23
1000
Q [US.gpm] 2000
1000
3000
Q [IM.gpm]
4000
2000
3000
20
Qmin
60
65
H [m]
60
70
75
65
60
65
[%]
78
70
75
80.4
78
70
75
79
78
78
78.2
78
200
50
Q [m3/h]
Q [l/s]
400
100
60
65
65
310/295
290/262
600
150
65
70
70
10
70
75
75
10
75
78
0.5
H [ft]
324
800
200
250
8
10
P [kW]
324
6
310/295
290/262
200
Q [m3/h]
400
600
800
K42184
Free passage
70 mm
32)
24
Rated power P2
[kW]
10,0
16,0
Mass moment of
inertia J [kgm2]
0,54
0,57
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
P [hp]
0
14
2000
Q [US.gpm]
2000
4000
6000
Q [IM.gpm]
4000
6000
40
12
Qmin
10
H [ft]
60
60
76
73
70
73
78
73
70.4
76
79.1
76.9
66
20
78
70
78
76
73.2
73
73
70
70
66
66
73
76
70
73
66
70
66
70
60
388/377
376/358
355/330
332/300
24
79.7
76
76
70
0.5
78
66
60
[%]
73
70
66
60
H [m]
70
66
60
66
0
0
600
Q [l/s]
800
1000
200
60
1200
1400
300
408
1600
400
30
20
408
P [hp]
20
388/377
376/358
P [kW]
10
355/330
10
332/300
600
800
1000
1200
1400
1600
K43131
Free passage
100 mm
33)
Rated power P2
[kW]
10,0
16,0
20,0
28,0
Mass moment of
inertia J [kgm2]
0,84
0,87
0,93
1,12
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
25
0
11
2000
Q [US.gpm]
4000
6000
3000
4000
5000
10
30
Qmin
ft
60
65
70
60
70
H [m]
60
60
65
[%]
73
65
75
73
70
H [ft]
75.4
75
74.1
65
72.6
70
20
73
73
71.5
70
65
0.5
19
600
100
Q [l/s]
800
1000
200
10
65
65
384/350
367/331
70
70
70
1200
300
408/393
398/371
1400
1600
400
15
20
P [kW]
408/393 P [hp]
10
398/371
384/350
10
367/331
600
800
1000
1200
1400
K43132
Free passage
135 mm
34)
26
Rated power P2
[kW]
10,0
16,0
20,0
28,0
Mass moment of
inertia J [kgm2]
0,84
0,87
0,93
1,12
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
1600
5000
Q [US.gpm] 10000
5000
Q [IM.gpm]
15000
20000
10000
15000
25
80
Qmin
20
50
60
60
50
70
60
15
75
50
50
H [m]
75
70
75
60
80
78
78
79.9
78.4
77.1
70
73
70
150
0
0
1000
200
Q [m 3/h] 2000
Q [l/s] 400
600
40
81
80
78
75
H [ft]
[%]
78
75
70
60
50
10
70
60
78
78
75
75
70
20
582/565
565/540
60
60
550/512
540/490
520/450
70
70
3000
800
75
70
4000
1000
1200
200
P [kW]
P [hp]
100
582/565
565/540
550/512
100
540/490
50
520/450
30
1000
Q [m 3/h]
2000
3000
4000
K42191
Free passage
133 mm
35)
Rated power P2
[kW]
90,0
110,0
130,0
150,0
Mass moment of
inertia J [kgm2]
7,2
7,47
7,77
12,5
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
27
0
17
5000
Q [US.gpm]
Q [IM.gpm] 4000
10000
6000
15000
8000
10000
12000
15
Qmin
40
50
60
50
10
70
60
75
50
70
60
50
75
70
60
H [m]
78
75
70
50
78
80
75
60
79.3
70
72.4
H [ft]
[%]
77.8
76.5
80.4
80
78
75
70
75
70
75
1500
Q [l/s]
2000
400
2500
600
70
70
582/565
565/540
550/512
540/490
60
60
520/450
75
70
60
20
78
75
3000
3500
800
1000
60
100
P [hp]
P [kW]
582/565
40
565/540
550/512
540/490
520/450
20
0
1500
2000
2500
3000
3500
K42192
Free passage
133 mm
36)
28
Rated power P2
[kW]
40,0
60,0
75,0
Mass moment of
inertia J [kgm2]
6,97
7,15
7,42
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan K
50
A
A
h2
h1
h4
DB
X
h3
X
d2
d1
45
60
45
20
D
Di
d7
d20
Dimensions of the pump set and seat ring
Dimensions [mm]
Size
Motor
size
700-324
700-324
700-324
700-324
700-330
700-330
700-330
37)
38)
20
26
10
17
29
20
26
Number of
poles
6
6
8
8
4
6
6
Pump
Seat ring
h1
h2
h3
h4
DB
d1
d2
[kg]37)
d7
d20
Di
D38)
1185
1160
1185
1185
1160
1185
1160
985
960
985
985
960
985
960
151
151
151
151
151
151
151
998
973
998
998
973
998
973
35
35
35
35
35
35
35
670
670
670
670
670
670
670
556
556
556
556
556
556
556
205
205
205
205
205
205
205
411
433
394
410
442
418
440
570
570
570
570
570
570
570
691
691
691
691
691
691
691
695
695
695
695
695
695
695
711
711
711
711
711
711
711
Pump set with 10-metre power cable (400 V) and 5-metre rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)
Amacan K
29
Motor
size
700-371
700-371
700-371
800-330
800-330
800-330
800-370
800-370
800-370
800-370
800-400
800-400
800-400
800-400
800-400
800-400
800-400
800-400
800-401
800-401
800-401
800-401
800-401
800-401
800-401
800-401
37)
38)
30
20
26
10
35
50
65
20
26
32
40
26
32
40
50
10
17
21
26
26
32
40
50
10
17
21
26
Number of
poles
6
6
8
4
4
4
6
6
6
6
6
6
6
6
8
8
8
8
6
6
6
6
8
8
8
8
Pump
h1
h2
1185
1160
1185
1410
1410
1410
1145
1120
1370
1370
1215
1465
1465
1465
1240
1240
1215
1465
1215
1465
1465
1465
1240
1240
1215
1465
985
960
985
1035
1035
1035
945
920
995
995
1015
1090
1090
1090
1040
1040
1015
1090
1015
1090
1090
1090
1040
1040
1015
1090
h3
h4
151 998
151 973
151 998
151 1219
151 1219
151 1219
148 960
148 935
148 1181
148 1181
183 995
183 1241
183 1241
183 1241
183 1020
183 1020
183 995
183 1241
183 995
183 1241
183 1241
183 1241
183 1020
183 1020
183 995
183 1241
Seat ring
DB
d1
d2
[kg]37)
d7
d20
Di
D38)
35
35
35
40
40
40
35
35
40
40
35
40
40
40
35
35
35
40
35
40
40
40
35
35
35
40
670
670
670
670
670
670
760
760
760
760
770
770
770
770
770
770
770
770
770
770
770
770
770
770
770
770
556
556
556
556
556
556
640
640
640
640
640
640
640
640
640
640
640
640
640
640
640
640
640
640
640
640
205
205
205
340
340
340
205
205
340
340
205
340
340
340
205
205
205
340
205
340
340
340
205
205
205
340
414
436
397
589
613
645
444
466
608
634
574
716
742
771
535
551
573
717
557
699
725
754
518
534
556
700
570
570
570
570
570
570
656
656
656
656
656
656
656
656
656
656
656
656
656
656
656
656
656
656
656
656
691
691
691
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
793
695
695
695
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
797
711
711
711
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
813
Pump set with 10-metre power cable (400 V) and 5-metre rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)
Amacan K
DB
h2
h1
h4
X
h3
45
d2
d1
D
20
45
60
Di
d7
d20
Dimensions of the pump set and seat ring
Amacan K
31
Motor
size
700-330
800-400
1000-420
1000-420
1000-420
1000-421
1000-421
1000-421
1000-500
1000-500
1000-500
1000-500
1000-500
1000-500
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
1200-630
39)
40)
32
80
60
60
80
100
60
80
100
80
100
120
140
165
190
190
225
260
320
90
110
130
150
40
60
75
Number of
poles
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
10
10
10
Pump
Seat ring
h1
h2
h3
h4
DB
d1
d2
[kg]39)
d7
d20
Di
D40)
2155
2210
2310
2510
2510
2510
2510
2510
2515
2515
2630
2630
2630
2885
2940
2940
2940
3205
2685
2685
2685
2940
2685
2685
2685
1465
1520
1620
1820
1820
1620
1820
1820
1825
1825
1940
1940
1940
2285
2340
2340
2340
2505
1995
1995
1995
2340
1995
1995
1995
151
183
209
209
209
209
209
209
205
205
205
205
205
205
268
268
268
268
268
268
268
268
268
268
268
1964
1985
2060
2260
2260
2060
2260
2260
2270
2270
2385
2385
2395
2620
2620
2620
2620
2875
2380
2380
2380
2620
2380
2380
2380
40
40
40
40
40
40
40
40
40
40
40
40
40
50
50
50
50
60
40
40
40
50
40
40
40
670
770
970
970
970
970
970
970
970
970
970
970
970
970
1140
1140
1140
1140
1140
1140
1140
1140
1140
1140
1140
556
640
840
840
840
840
840
840
820
820
820
820
820
820
960
960
960
960
960
960
960
960
960
960
960
917
1041
1274
1364
1434
1294
1384
1454
1385
1455
1745
1805
1855
2495
2730
2900
3120
3740
1980
2050
2110
2720
1920
1960
2030
570
656
856
856
856
856
856
856
856
856
856
856
856
856
1015
1015
1015
1015
1015
1015
1015
1015
1015
1015
1015
691
793
992
992
992
992
992
992
992
992
992
992
992
992
1192
1192
1192
1192
1192
1192
1192
1192
1192
1192
1192
695
797
996
996
996
996
996
996
996
996
996
996
996
996
1196
1196
1196
1196
1196
1196
1196
1196
1196
1196
1196
711
813
1016
1016
1016
1016
1016
1016
1016
1016
1016
1016
1016
1016
1220
1220
1220
1220
1220
1220
1220
1220
1220
1220
1220
Pump set with 10-metre power cable (400 V) and 5-metre support rope
D for recommended wall thickness of the discharge tube (see dimension s1 in the General Arrangement Drawings)
Amacan K
BU discharge tube
overflow design
DU discharge tube
with above-floor discharge nozzle
CU discharge tube
with underfloor discharge
Scope of supply
Amacan K
33
59-8
59-17.2
59-24
720
59-47*
59-17.1
59-7
UG 1073883zdk
*= The number of (intermediate) lifting rings depends on the lifting height of the lifting equipment and on the building structure. (Intermediate lifting rings are supplied as an option).
List of components
Part No.
59-8
59-17.2
59-47
59-24
720
59-17.1
Description
Turnbuckle
Shackle
(Intermediate) lifting ring(s)
Rope, low rotation design
Spacer
Shackle
59-7
Support spacer
34
Amacan K
Material
Stainless steel
Stainless steel
Stainless steel
Stainless steel
EPDM
Galvanised steel (stainless
steel optional)
GFRP
1
6
3
5
4
OW 380 091-00
List of components
Part No.
1
2
3
Description
Cable clamp (approximately every 400 mm)
Control cable
Power cable
Part No.
4
5
6
Description
Support rope 59-24
Spacer
Clamp cover
A
A
2
OW 380 836-00
List of components
Part No.
1
Description
Discharge tube cover41)
Part No.
4
2
3
Cover
Welding sleeve
5
6
41)
Description
Threaded bush with cable entry to DIN 22419 with strain
relief and protection against kinking and twisting
Eyeplate for fastening the cable support (support rope)
Gasket, e.g. rubber with fabric reinforcement
Amacan K
35
2
3
A-A
A -- A
OW 380 861-00
List of components
Part No.
1
2
3
4
5
6
7
8
42)
36
Description
Discharge tube cover42)
Transit frame (cable gland)
Packing and insert blocks
Cover segment with cable gland
Closed-cell profile joint in groove between the two cover parts
Sealing arrangement of groove between the two cover parts
Support brackets for cover segment with cable glands
Gasket (e.g. rubber with fabric reinforcement)
Amacan K
571
811
818
412
834
330
433
433
230
412
412
101
163
502
UG 1294437
List of components
Part No.
101
163
230
330
412
433
Description
Pump casing
Discharge cover
Impeller
Bearing bracket
O-ring
Mechanical seal
Part No.
502
571
811
818
834
-
Description
Casing wear ring
Bail
Motor housing
Rotor
Cable gland
-
Amacan K
37
571
330.02
412
834
811
818
412
330
412
433
412
412
433
163
230
412
101
502
List of components
Part No.
101
163
230
330
412
433
38
Description
Pump casing
Discharge cover
Impeller
Bearing bracket
O-ring
Mechanical seal
Amacan K
Part No.
502
571
811
818
834
-
Description
Casing wear ring
Bail
Motor housing
Rotor
Cable gland
-
834
812
412
811
330
818
412
412
433
350
412
433
163
230
502
412
412
101
List of components
Part No.
101
163
230
330
350
412
433
Description
Pump casing
Discharge cover
Impeller
Bearing bracket
Bearing housing
O-ring
Mechanical seal
Part No.
502
571
811
812
818
834
-
Description
Casing wear ring
Bail
Motor housing
Motor housing cover
Rotor
Cable gland
-
Amacan K
39
19.09.2013
1579.5/06-EN
KSB Aktiengesellschaft
P.O. Box 200743 06008 Halle (Saale) Turmstrae 92 06110 Halle (Germany)
Tel. +49 345 4826-0 Fax +49 345 4826-4699
www.ksb.com