Berikut merupakan klasifikasi regulasi fire safety dibeberapa Negara seperti di table
dibawah ini:
Klasifikasi
Fire-fighting

New Zealand
Kebakaran
dikategorikan

Malaysia
Hongkong
Fire-fighting equipment Every firefighting and

equipment

kedalam 6 bagian yaitu

or

(class A to F) untuk dapat

installation means any should be enclosed by

menentukan jenis pemadam

equipment

kebarakan yang jauh lebih

installation for:

efektif:
Class A kayu, kertas,

extinguishing, fighting, balustrades, partition

dan plastic
Perceived : Clothing fire

including wall and


a fire;
giving warning of a ceiling lining and
fire;
floor finishing, in the
providing access to
stairway should be
any premises or place
constructed of wholly
or to any part thereof
non-combustible
for the purpose of
materials.
extinguishing, fighting,

a fire in the clothes


being worn by a person,
Small
solids

carbonaceous
fire,

Large

carbonaceous solids fire.


Prefereed extinguishant:
Water,

Foam,

ABE

powder, Wet chemical,


Vaporizing

liquid,

Carbon dioxide (limited).

fire

safety rescue

or walls and these walls,


the landings, flights,

preventing, or limiting walls and finishing,

preventing, or limiting
a fire;
providing

emergency

power supply in the


event of normal power

Class B cairan mudah


terbakar (bensil, oli)
Perceived:
Petroleum
based

liquid,

Polar

solvents.
Prefereed extinguishant:
BE and ABE powder,
Alcohol resistant foam.

stairway

failure;
providing

emergency

lighting for purposes


of

escape

buildings;
giving
towards
route
refuge;

direction
an

or

from

escape

place

of

Nama : Bagaswara Ramadhan


NPM : 1206224426
Class C gas yang
mudah terbakar
Perceived: Gas fires.
Prefereed extinguishant:

providing

adequate,

safe egress for the


purpose of evacuation
or exit of occupants in

BE and ABE powder.


Class D logam yang

the event of fire;

mudah terbakar
Perceived: Metal fire.
Prefereed extinguishant:
Special powder.
Class E kebakaran
listrik
Perceived: Fire involving
energized

electrical

equipment.
Prefereed extinguishant:
BE and ABE powder,
Vaporizing

liquid,

Carbon dioxide.
Class F kebakaran
yang ditumbulkan akibat
minyak goring
Perceived: Cooking oils
and fats fires.
Prefereed extinguishant: Wet
chemical, BE powder, Fire
Fire

blanket, Foam (limited).


Safety A Fire Evacuation Scheme Evacuation is limited by A

Performance

Requirements is developed to move people the availability of such Requirement has been
on
Lifts

Using promptly,

safely,

and lift. Therefore, passenger developed in Part A to

For efficiently from a place of lifts shall be designed for provide guidance for

Evacuation

danger to a place of safety. use together with the fire the safe evacuation

Nama : Bagaswara Ramadhan


NPM : 1206224426
of

This includes:

lifts so as to speed up from tall buildings.

Building

a. evacuation management, occupant evacuation.

The following aspects

Occupants

what needs to be done in Passenger lifts shall be should be complied

During

the

Emergency.

evacuation, and how it is following features:

event

of

fire designed

to be done

a. Fire

b. the method for managing

with
lift

Where

the with:
a.provide means of

switch.
there

is

escape for building


occupants - Means

the evacuation process

provision to manually

by

including training, signs

override

occupants

and notices, fire fighting

passenger lifts at the

escape

equipment,

FCC by authorized

building should be

warning, and evacuation

personnel

or

fire-

provided.

process maintenance.

fighters,

fire

lift

b.allow for occupants

A Fire Evacuation Scheme

switch need not be

to take a short rest,

may

installed.

whilst evacuating -

not

approval.

means

require

of

NZFS

However,

the

the b. Power cables which

which

all
can

from

It is recognised that

building owner may submit

are routed through an

persons

area of negligible fire

many

risk.

stairs need to take a

voluntary

scheme

for

approval by the NZFS.

walking
flights

of

Where a building requires a

short rest during the

Fire Evacuation Scheme, the

evacuation.

building owner must apply

c.minimise the threat

to the NZFS for scheme

of

approval. This they may do

required staircases

directly

required

or

through

acting as their agent.

you

smoke

within

staircases

should be designed
to prevent smoke
clogging and should
provide a tenable
environment
evacuation.

for

Nama : Bagaswara Ramadhan


NPM : 1206224426
d.provide an area for
firefighting staging
activities Space
should be required
to provide a means
for

firefighting

staging activities.