MRP-Q Nuclear Magnetic Resonance Logging System
MRP-Q Nuclear Magnetic Resonance Logging System
Sensors
6 sensor
4 sensor
Work environment
No cased well
Downhole fluid:
Logging fluid, water, oil, air
Measuring position:
Middle
Measuring Range
0-100pu
T2 measuring range
0.5ms-2048ms
Maximum error
5% or 1pu
T2 resolution ratio
0.5ms
Maximum echo number
500
Minimum echo interval
0.6ms
Resonant frequency
9
Temperature resistance
175C
Withstand voltage
137.9Mpa
Maximum logging speed
24 feet/minute 12feet/minute
Diameters of the sensor
152.4mm
123.825mm
Length (includes MREE, MREP, MRMD) 13.6m
13.2m
Maximum radius of investigation
42.6cm
29.6cm
Specifications for D4TG Telemetry and Gamma cartridge for logging system
350
>
Length
86.4 inches
Weight
110 pounds
Wellbore conditions
Borehole fluid:
middle
Sampling rate:
4 or 12 sampling point/feet
Upload speed/frame:
Telemetry system:
640words/frame (maximum)
Compatible with DITS
Combination:
Principle
natural gamma
Range
0 1000API
Vertical resolution:
The depth of detection:
Sensitivity:
Precision:
1% on moving
Principal curves:
Assisted curves:
Fax713.977.0440