LM82 Luma 2
LM82 Luma 2
.
ACCREDITATION UNDER NVLAP LAB
CODE 100402-0.
.
REPORT
3933 US ROUTE 11
Project No.
G101731733
Date:
REPORT NO.
101731733CRT-011
L303501228
Philips L303501228
Xitanium 75W 0.35-0.7A GL Prog+ sXt
Osram Oslon
RENDERED TO
Philips Lighting Middle East & Turkey
Dubai Knowledge Village - Al Sofouh 2 PO Box 7785
DUBAI, UNITED ARAB EMIRATES
TEST:
Electrical and Photometric tests over different temperatures as required to the IESNA LM-82
test standard.
STATEMENT OF
LIMITATION:
This report must not be used by the client to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the federal government.
AUTHORIZATION:
500537328
STANDARDS USED: The following American National Standards or Illuminating Engineering Society of North
America Test Guides were used in part or totally to test each specimen:
IESNA LM-79: 2008
Approved Method for Electrical and Photometric Measurements of Solid-State Lighting Products
Approved Method for Characterization of LED Light Engines and LED Lamps for Electrical and Photometric
Properties and a Function of Temperature
Energy Star Version 1.2 (2012): Program Requirements for Luminaires (Light Fixtures)
SAMPLE DESCRIPTION
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and
conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report.
Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or
service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product,
or service is or has ever been under an Intertek certification program.
SUMMARY
Light Engine Model No.:
Description:
Driver Model No.:
LED Source Model No.:
L303501228
Roadway Luminaire
Xitanium 75W 0.35-0.7A GL Prog+ sXt
Osram Oslon
Criteria
Ambient Temperature (C)
Tb (C)
Td (C)
Ts (C)
Total Lumen Output (Lumens)
Total Power (W)
Luminaire Efficacy (LPW)
Power Factor ( )
Current ATHD (%)
Correlated Color Temp.(CCT-K)
Color Rendering Index (CRI - Ra)
Duv ( )
Chromaticity Coordinate (x)
Chromaticity Coordinate (y)
Chromaticity Coordinate (u)
Chromaticity Coordinate (v)
Initial Reading
(25C Ambient)
25.0
58.5
53.6
58.5
23271.0
205.2
113.4
0.966
15.1
3965
74.3
-0.003
0.380
0.371
0.227
0.499
Second Reading
(Tb + 25C)
52.0
83.5
87.1
83.4
22400.7
202.6
110.6
0.966
15.7
3996
74.2
-0.002
0.379
0.372
0.226
0.500
Criteria
Maximum In-Situ Source Temperature Point (C)
Final Reading
(=client choice)
42.0
75.0
79.4
75.4
22747.5
203.3
111.9
0.966
15.5
3983
74.2
-0.002
0.380
0.372
0.227
0.499
Result
62.3
EQUIPMENT LIST
LM-82 Equipment Used
Model
Number
Control
Number
Extech Hygro-Thermometer
Elgar AC Power Supply
YokoGawa Power Analyzer
CCD Spectroradiometer
ITS 2 Meter Integ. Sphere Chamber
Labsphere Chamber controler
Sorensen DC Power Supply
445703
CW1251
WT1600
CDS 1100
CSLMSLED-7660
Omega
XFR 150-8
T1355
NA
E440
O235
2M3
2M3
N/A
Model
Number
Control
Number
Extech Hygro-Thermometer
Fluke Multimeter
Fluke Temp Meter
445703
87
53 II
T1355
E259
N1324
2 of 10
Last Cal.
Date
Cal. Due
Date
12/30/2013 12/30/2014
VBU
VBU
4/18/2014
4/18/2015
NA
NA
VBU
VBU
VBU
VBU
VBU
VBU
Last Cal.
Date
Cal. Due
Date
12/30/2013 12/30/2014
3/20/2014
3/20/2015
3/21/2014
3/21/2015
TEST METHODS
Seasoning in Sample Orientation LED Products
No seasoning was performed in accordance with IESNA LM-79 and IESNA LM-82.
Sample No.
CRT1408181526-002
Total Hours
2.92
In-Situ Maximum Measured Power Supply Case and LED Source Point Temperature
Power supply case and/or LED source operating temperature measurements were taken on one test
sample per model with a thermocouple and Fluke 87 temperature meter. The SSL sample was allowed to
reach thermal equilibrium for seven and a half hours before measurements were taken. Power supply or
source temperature measurements were measured at the TMPPS or TS point as indicated by the included
diagram in accordance with manufacturers declared hot spot location, or at a hot spot location found with a
thermal camera when no diagram from the manufacturer is given. The maximum temperature was recorded
for the sample. A simulated ceiling or other enclosure may be used in accordance to UL 1598 or UL 153 as
applicable.
3 of 10
RESULTS OF TEST
25 C
mW/nm
nm
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
0.001179
0.001056
0.001017
0.001019
0.000947
0.000911
0.000816
0.001049
0.001307
0.001890
0.003105
0.005498
0.010339
0.020224
0.039104
0.069249
0.112471
0.166457
0.213960
0.190352
0.112638
0.068677
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
Sample No.
mW/nm
nm
CRT1408181526-002
0.047780
570
0.031699
575
0.024130
580
0.022135
585
0.023146
590
0.028073
595
0.036998
600
0.048436
605
0.061290
610
0.073881
615
0.085827
620
0.095784
625
0.104924
630
0.113090
635
0.120169
640
0.126167
645
0.132220
650
0.139020
655
0.144830
660
0.150895
665
0.156673
670
0.161315
675
CRT1408181526-002
mW/nm
nm
mW/nm
0.165407
0.167996
0.170371
0.171008
0.169551
0.167890
0.164151
0.158986
0.152768
0.145469
0.137338
0.128841
0.119175
0.109823
0.101167
0.092138
0.083652
0.075320
0.067560
0.060358
0.053867
0.047741
680
685
690
695
700
705
710
715
720
725
730
735
740
745
750
755
760
765
770
775
780
0.042125
0.037436
0.032932
0.028950
0.025523
0.022312
0.019592
0.017152
0.015153
0.013166
0.011473
0.010011
0.008751
0.007741
0.006740
0.005912
0.005326
0.004612
0.004032
0.003555
0.003142
Model No.
L303501228
mW/nm
0.2
0.15
0.1
0.05
0
350
400
450
500
550
600
650
700
750
Nanometers
4 of 10
mW/nm
nm
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
0.001229
0.000976
0.000938
0.000951
0.000882
0.000826
0.000718
0.001006
0.001271
0.001843
0.003122
0.005437
0.010022
0.019117
0.035514
0.060927
0.096610
0.139130
0.183163
0.184973
0.125888
0.077205
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
Sample No.
Tb =
mW/nm
nm
CRT1408181526-002
0.053971
570
0.037331
575
0.027613
580
0.024535
585
0.024973
590
0.028857
595
0.036493
600
0.046791
605
0.058615
610
0.070211
615
0.081499
620
0.091272
625
0.100187
630
0.108295
635
0.115515
640
0.121496
645
0.127688
650
0.134413
655
0.140391
660
0.146404
665
0.151973
670
0.156421
675
CRT1408181526-002
83.5 C
mW/nm
nm
mW/nm
0.160240
0.162234
0.164405
0.164647
0.162674
0.160679
0.156784
0.151573
0.145232
0.138169
0.130484
0.122219
0.113192
0.104223
0.095922
0.087494
0.079479
0.071568
0.064366
0.057571
0.051497
0.045665
680
685
690
695
700
705
710
715
720
725
730
735
740
745
750
755
760
765
770
775
780
0.040435
0.035890
0.031731
0.027906
0.024678
0.021656
0.018970
0.016743
0.014806
0.012879
0.011242
0.009835
0.008661
0.007639
0.006726
0.005846
0.005256
0.004569
0.004043
0.003533
0.003137
Model No.
L303501228
mW/nm
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
350
400
450
500
550
600
650
700
750
Nanometers
5 of 10
mW/nm
nm
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
0.001229
0.001016
0.000985
0.000919
0.000858
0.000883
0.000739
0.001055
0.001242
0.001827
0.003112
0.005462
0.010204
0.019619
0.036868
0.063733
0.101842
0.148166
0.194015
0.188354
0.121922
0.074221
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
Sample No.
mW/nm
nm
CRT1408181526-002
0.051828
570
0.035345
575
0.026316
580
0.023680
585
0.024351
590
0.028517
595
0.036746
600
0.047429
605
0.059574
610
0.071639
615
0.083200
620
0.092896
625
0.101979
630
0.110103
635
0.117402
640
0.123366
645
0.129520
650
0.136182
655
0.142277
660
0.148225
665
0.153910
670
0.158451
675
CRT1408181526-002
75 C
Tb =
mW/nm
nm
mW/nm
0.162363
0.164571
0.166902
0.167084
0.165462
0.163564
0.159773
0.154517
0.148152
0.140987
0.133126
0.124825
0.115614
0.106534
0.098012
0.089295
0.081194
0.073047
0.065673
0.058674
0.052516
0.046486
680
685
690
695
700
705
710
715
720
725
730
735
740
745
750
755
760
765
770
775
780
0.041132
0.036515
0.032315
0.028309
0.024955
0.021903
0.019269
0.016898
0.014968
0.013056
0.011319
0.009940
0.008713
0.007683
0.006738
0.005914
0.005318
0.004602
0.004015
0.003552
0.003154
Model No.
L303501228
mW/nm
0.2
0.15
0.1
0.05
0
350
400
450
500
550
600
650
700
750
Nanometers
6 of 10
Test
Ambient (25C)
Tb + 25C
Choice
Test
Ambient (25C)
Tb + 25C
Choice
Test
Ambient (25C)
Tb + 25C
Choice
Tb (C)
58.5
83.5
75.0
Base
Intertek Sample No.
CRT1408181526-002 Horizontal
CRT1408181526-002 Horizontal
CRT1408181526-002 Horizontal
Td (C)
53.6
87.1
79.4
Ts (C)
58.5
83.4
75.4
Luminous
Flux
(Lumens)
23271.0
22400.7
22747.5
Input
Voltage
(Vac)
230.1
230.1
Input
Current
(mA)
923.4
911.6
Input
Power
(Watts)
205.2
202.6
230.1
915.1
203.3
CRI
-R9
-10.8
-12.4
DUV
-0.003
-0.002
-11.8
-0.002
Lumen Correlated
Efficacy
Color
(LPW) Temp. (K)
113.4
3965
110.6
3996
111.9
3983
Input
Power
Factor
0.966
Current
ATHD
(%)
15.1
0.966
0.966
15.7
15.5
CRI
-Ra
74
74
74
CIE 31
CIE 31
CIE 76
CIE 76
Chromaticity Chromaticity Chromaticity Chromaticity
Coordinate Coordinate Coordinate Coordinate
(x)
(y)
(u)
(v)
0.380
0.379
0.371
0.372
0.380
0.372
7 of 10
0.227
0.499
0.226
0.227
0.500
0.499
125.0
9.4
3.5
696.0
2.4
102.1
C
C/W
V
mA
W
C
Sample No.
Maximum Measured
Source Temperature
Location
Maximum Rated
Source Temperature (C)
CRT1408181526-002
CRT1408181526-002
CRT1408181526-002
62.3
62.3
66.8
Ts
Tb
Td
102.1
125.0
80.0
8 of 10
non
58.5
71.0
83.5
eff lin
113.4
112.0
110.6
in-sit
62.3
113.0
55.0
60.0
65.0
In-Situ Tb vs.
Linear Projection
58.5
75.0
83.5
23271.0
22747.5
22400.7
113.4
111.9
110.6
Linear Projection
(LM-82 Lumens
vs. LM-82 Tb)
LM-82 Lumens vs.
LM-82 Tb
70.0
75.0
80.0
85.0
Temperature (C)
113.5
Efficacy
113.0
112.5
Linear Projection
(LM-82 Efficacy
vs. LM-82 Temp.)
112.0
111.5
111.0
110.5
110.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
Temperature (C)
9 of 10
Td monitoring point
Ts monitoring point
CONCLUSION
The results tabulated in this report are representative of the actual test samples submitted for this report only. The data
is provided to the client for further evaluation. Compliance to the referenced specification requirements was not
In Charge Of Tests:
Gerald Gray
Associate Engineer
Lighting Division
Jeffrey Davis
Engineering Manager
Lighting Division
Attachment: None
10 of 10