Preface. ............ ............ ............ ............ ............ ............ ............ ............ ............ ................ ............ ............2
safe note ............................ ............................ ............................ ............................ ............ ............ ................2
1Energizer Specifications............................ ................... ............ ............ ............ ............ ........................3-4
1.1 Product design Standard.
-1-
-2-
-3-
Electric fence
Quick Start Guide
Copyright @2013 Shenzhen Tongher Technology Co.Ltd .All Rights Reserved
No part of this manual,including the products and figures described in it , may be reproduced ,transmitted,transcribed,
Stored in a retrieval system,or translated into any language in any form or by any means,except documentation kept by
the purchaser for backup purposes,without the express written permission of Shenzhen Tongher Technology Co.Ltd
Safety Information
Unless high/low voltage output disarmed of electric fence, dont touch live fence
Always unplug the fence before handing any part of the fence
Dont install electric fence during the thunder, dont install controller in moist place.
Before installation or using the product, professional training on technology is necessary
To maximizing the performance of your fence system,During the installation, follow the
instructions to make sure the grounding of products. Refer to 4.9 item
Once electrified , the inside of controller is 220v 50Hz AC, with 5-10KV high voltage pulse on
the output port , dont touch any part to make sure safety
The related electronic technology knowledge is necessary, read the user instruction and operate
it carefully with correct methods before installation, otherwise,our side dont bear any
responsibility if any accident arise.
-4-
In case of urgency, turn off power supply, and wait for the professional staffs to check analysis
and repair ,or contact our company, dont repack it by your own.
Follow all national,state and local regulations that may apply to installation of electric fence in
your area
Refer to authorized repair center or our company for service,There are no ueser serviceable
parts,Never alter the design of the energizer ,doing so is dangerous and will void the warranty.
Do not run fence wire above ground near high voltage power lines.if too close,the electric fence
may pick up dangerous levels of power from high voltage lines.Never cross under a high
voltage line with electric fence.
Sparks may occor in electric fence system,Therefore,the area of high fire risk,fence should not
be installed.
1Energizer Specifications
1.1 Product design Standard:
GB/T7946-2008 "Pulse electric fence installation And Safe operation"
IEC 60335-2-76
1.2 Product characteristic:
Differential voltage output technology: every wire has voltage, have the differential voltage between the two
adjacent wires.
LCD or LED indicate the working state and the voltage on every wire of fence.
High/low voltage switch manually, long-distance equipment auto switch function.
Short circuit, break and tamper alarm, Self-inspection System for equipment fault
Waterproof casing and downward appearance design leading the industry development.
RS 485 bus control, keypad, computer, network and multiple long distance management solution.
-5-
DC12V, NC/NO dry contact alarm output, can work with other modern security products.
The controller comprise two parts: input and output,the positive pulse from output part1st line high voltage output
port transfer to fence wire, then return back to the receiver part 1st line high voltage input port, negative pulse
from output2nd line high voltage output port transfer to fence wire, then return back to the receiver part 2nd line
high voltage input port ,so form positive and negative pulse closed circuit on the front fence.
-7-
High voltage earth output: can share the same earth output with lightning arrester, strong/weak earth separate.
Voltage switch: use for switching high/low voltage mode or automatic working mode.
Keypad output: can connect keypad directly or RS485 transfer RS 232,then connect to computer by long distance
control, The RS 485 connection of each controller needs to go hands by hands connection, multiple connection is
not allowed.
Switch output: output open/close dry contact signal, needs to connect with other linkage device.
Alarm output: when alarm, output DC 12V voltage, connect with alarm device DC 12v below 10W.
Power switch: control the energizer on/off.
Power supply input: connect AC 220V power source.
-8-
2.2 Security
Not allow to get the AC power supply on electric fence. when the product gets faulty, please make sure the electric
fence without any AC power supply.
Product used the rectification voltage dropping DC 12V, then voltage-rise to condenser charge, finally electric
capacity pulse discharge boosting transformer, the output energy is limited by rectification, primary voltage-rise,
electric capacitance discharge, so many links, without harm to human body and absolute safety.
Electric fence should not be with other power circuit and telecommunication wires on the same pole.
Electric fence should keep a certain safe distance from the power circuit. The minimum distance as shown in the
table
Electric cable voltage rank
10KV below
2.5m
2m
35110KV
5m
3m
220KV
7m
4m
330KV
9m
5m
500KV
9m
5m
Horizontal distance between electric fence and public rod border should be above 5m( except the electric fence on
top of the wall)
Electric fence has pulse high voltage, when bad connection or close to charged conductor, will have fire spark.
Thus, electric fence should install without any flammable gas, and without any flammable fluid place. According to
the related national standard, keep enough safe distance, or take the safe measures to isolate.
When inspect the place to install electric fence, pls make sure the electric fence without any conflict with the
electric wire, pipeline from the ground. And without any sundry goods at nearby place, whether the electric fence is
influenced strongly by transmitting station and other high frequency device. If have, must mark the signal wire with
-9-
- 10 -
have welding ,clip or buried the three modes, should choose suitable mode according to the fence structure condition.
For example, install at the steel fence, can take the welding, install at the concrete wall, can take buried mode to make
sure stable, artistic, may use other modes also.
- 12 -
3.3 Rods installation angle: ( the angle with wall) As shown in Figure 7.
According to the site condition and the first party
request(022.54567.590112.513515
7.5
inclination angle or
The middle pull insulator assembles on the rod through screws or use pinlock to fix it. Should note the direction of
installing, usually every 20 meters to set a middle pull rod. See the right drawing:
3.6 Tensioner installation As shown in Figure 10.
The middle tensioner usually hang on the front of electric fence,when
install alloy wire, penetrates the wire from the tensioner sides round
hole, aim and pass the middle hole, finally gets out from another side
round hole. See the chart. Note, dont make the tight line excessive, heat
Figure 10. Tensioner installation
expanded and cold contracted, it maybe break in winter weather.
3.7 Lightning arrester installation
Firstly fix the lightning arrester on the top of terminal rod,then through the own nuts fixing on the frame, the lightning
arrester usually installs on top of pulse energizer, every zone must install two lightning arresters. As shown in Figure
11.
3.10 Grounding/earth
grounding request: according to GB/T 7946-2008, earth principle and weak electricity separated. The electric fence
system includes: controller high voltage output earth, lighting arrester earth, protective earth output, the three kinds of
earth. High voltage earth and lightning arrester earth can share the same earth, but must separate from protective earth,
and the earth pole distance is above 10meters, the earth pole depth of burying is above 1.5m, the resistance value of
weak electricity should be below 4, the resistance of high voltage earth should be below 10,the lightning arrester earth
connects reliably by square millimeter copper wires.
Electric fence underground layout, should avoid high voltage insulated conductor,as the underground is usually
moist, it is hard to keep good insulation strength at the tie-in. if tie-in avoidless, should strengthen the tie-in part
insulativity, for example, use the Silastic envelope, or change the tie-in above the ground.
- 15 -
Note
: in a electric fence system, if the quantity of fence controller is above one unit, and needs keypad or
computer to centralized control, after the controller electrified check, need correct monitor zone number of the
electric fence controller through keypad or computer. Make every controller zone number is the sole number in
the system, without any conflict in the communication process. Monitor zone number can be set as any digit
from 1-16. the default monitor zone number from factory is 2, after finish it completely, then use hand in
hand mode to connect all the fence controller.
4.2
Alarm test
short circuit: with the metal wire short circuit any two neighboring lead wire or to the ground, about 3 seconds, the
controller alarm, the red alarm indicated lamp of board in short circuit is bright, after eliminating the triggering
source, the controller alarm delays 30s, then automatic reset, system recovers normally. ( except for the keypad
and computer reposition)
- 16 -
Break: pluck any insulated wire from wiring column, about 3 seconds, the red indicated lamp of break is bright,
after eliminating the triggering source, controller alarm delays 30s, then automatic reset, system recovers normally.
Tamper: open the controller covering, the controller alarms, the red alarm indicated lamp of tamper on board is
bright. Close the controller covering, controller delays 30s alarm, then automatic reposition, the system recovers
normally.
5 Work standard
- 17 -
by the cigarette lighter roasting the solder flick) meanwhile, complete waterproof insulation processing,
especially the underground pipe.
when install lightning arrester, the minimum depth of pile must infiltrate below underground 1.5m, the resistance of
high voltage lightning arrester should be below 10, weak current connecting earth should be below4. The
lightning arrester should install at the beginning, means approaching the energizer end, the top side of lightning
arrester connects the highest high voltage cable of electric fence. The end side of lightning arrester buries in the
ground, uplead wire uses the high voltage insulated wire, downlead wire must connect earth reliably. Follow the
drawing 6.2item.
between wall pillar(10m),should hang a warning signs to remind intruder fully.
main lines selected specification: RVSP*1.0mm double twists belt shield transmission line, the length of main line
surpass 900meters,need to add a 485 repeaters at every other 900meters.
power line selected specification: RVV2*1.5mm power supply line, when the length of supply line surpass 800
meters, enlarge the line diameter.
high voltage insulated wire insulating layer reaches 15KV pulse voltage, the material of wire core is aluminum.
if use the multiple zone system, when single zone alarm controller put outdoor, must put in stainless steel
waterproof tank which hangs on the wall, or concrete foundation laying ground.
5.2 Other notes of construction
5.2.1 if the pillar of wall is wide, should design the electric fence approaching the wall center, pedestals installed
outward ,guarantee without any blind spot situation, prevent climbing over the fence through the wall.
5.2.2 pulse electric fence system should not connect with other grounding system, and keep above 10m distance away
connecting ground independently.
5.2.3 when alloy wire lengthen, connect the tie-in by wire linker.
5.2.4 the product electric pulse will not injure the intruder, but should avoid the association factor, in order to settle the
issue, firstly, in the striking site of electric fence, hang up the warning signs electric fence, forbid climbing at every
other 10 meters, give the intruder a warns, not to touch it. Secondly, the height of electric fence should be above 1.8m
to make sure the accident. If the height of electric fence is not enough, in order to avoid the personnel touching
accidently, should install the isolated electric fencing at both sides.
5.2.5 electric fence pulse energy, will produce the spark sometimes, hence, should not have flammable gas existing
- 18 -
around.
5.2.6 electric fence should keep safe distance with power circuit.
5.3 Troubleshooting ( Frequently Asked Questions)
Question
Communications
Eliminated methods
keypad
failure
computer
break
1 Check whether the connection of outer electric fence break or short circuit, use the
multimeter to test every loops go through, the resistance of two loops should be
strong enough..
2
Short circuit
When turn low voltage situation, check whether the tie-in connection good or not
1 When controller connects power supply, the two high voltage output loops whether
connect the outer fence or use wire in short circuit.
2 Check the port of alarm output whether exist short circuit.
3 Whether only use the battery as power supply ( backup battery first use, if the
power is weak, after charge 12 hours, then can work normally.
- 19 -
- 20 -