Catalogue Panel Meter
Catalogue Panel Meter
Catalogue Panel Meter
DIMENSIONS in mm
96x24
Weight: 0,15 Kg
24x96
Weight: 0,15 Kg
116
CUT OUT
CUT OUT
117
DIMENSIONS in mm
Length of the scale graduation: 58 mm
A55N mask
CUT OUT
53
3
46
45
12
25
,4
54
A55R mask
EMI55M / EMC55M
74+0,2
41+0,2
Depth
CUT OUT
A70N mask
65
4
60
52,5
34,5
,5
69
12
94+0,2
A70R mask
EMI70M / EMC70M
59+0,2
Depth
Cut out with use of
A70R mask
118
119
DIMENSIONS in mm
72x72
48x48
96x96
144x144
1COR
120
Ammeter
48 = 0,30,8VA
Voltmeter
48 = 1,22VA
40 60 Hz
1,5
250, 400, 600, 800, 900 mA
72/96/144 = 0,31,2VA
72/96/144 = 1,54VA
OPERATING FREQUENCY
ACCURACY CLASS
MILLIAMMETER CAPACITIES
AMMETER CAPACITIES
1-1,5-2,5-4-5-6-10-15-20-25-30-40-50-60A
direct input
input by means a C.T., secondary 1A or 5A
.../1A, .../5A
VOLTMETER CAPACITIES
6-10-15-25-40-60-100-150-250-300-400-500-600V direct input
.../100V, .../110V
input by means a V.T., secondary 100V or 110V
Different capacities can be carried out on request
EXAMPLES WHEN ORDERING
ERI48 5A5+ESI48 50A5
ammeter input by means a C.T., secondary 5A, 50/250/5A end scale value, 90 5In
ERI48 500/100V
voltmeter input by means a V.T., secondary 100V, 500V end scale value
for use with VT 500/100V, 90
ERI72 5A1+ESI72 100A1 ammeter input by means a C.T., secondary 5A, 100/5A end scale value, 90 1In
ERI96 5A2+ESI96 600A2 ammeter input by means a C.T., secondary 5A, 600/1200/5A end scale value, 902In
ERI144 600V
voltmeter direct input, 90
MEDIUM WEIGHT (Kg)
ERI48 (0,10)
ERI72 (0,20)
ERI96 (0,30)
ERI144 (0,35)
For connection diagram see page 139
Ammeter
0,31,2VA
Voltmeter
1,54VA
OPERATING FREQUENCY
40 60 Hz
ACCURACY CLASS
1,5
AMMETER CAPACITIES (with interchangeable scale plate)
.../5A2
input by means a C.T, secondary 5A, 2In
ammeters provided with one pole switch, low voltage, for three current transformers L1-L2-L3
VOLTMETER CAPACITIES
6-10-15-25-40-60-100-150-250-300-400-500-600V direct input
.../100V, .../110V
input by means a V.T., secondary 100V or 110V
voltmeters provided with switch, low voltage, for three phase-phase and three phase-neutral voltage
L1N-L2N-L3N / L1L2-L2L3-L3L1
Different capacities can be carried out on request
PROTECTION ON FRONT
IP00
EXAMPLES WHEN ORDERING
ERIC72C 500V
voltmeter direct input, 500V end scale value
ERI96C 5A2+ESI96C 100A2
ammeter without scale plate, secondary 5A, input by means a C.T., 2In
+ interchangeable scale plate 100/200/5A
MEDIUM WEIGHT (kg):
0,25
For connection diagram see page 139
121
Ammeter
Voltmeter
ACCURACY CLASS
1,5
For capacities of more than 5A, use current transformers.
These instruments are constructed for the measurement of alternating current, from 25 to 10,000Hz, and are
gauged for reading the effective value of the sinusoidal current. For other wave forms please consult us.
MICROAMMETER CAPACITIES
100-150-250-400-600A
MILLIAMMETER CAPACITIES
1-1,5-2,5-4-5-6-10-15-20-25-40-60-100-150-250-400-600mA
AMMETER CAPACITIES
1-1,5-2,5-4-5
direct input
.../1A, .../5A
input by means a C.T, secondary 1A or 5A
VOLTMETER CAPACITIES
6-10-15-25-40-60-100-150-250-300-400-500-600V direct input
input by means a V.T., secondary 100V or 110V
.../100V, .../110V
Different capacities can be carried out on request
EXAMPLES WHEN ORDERING
ERR48 15A
ammeter direct input, 15A end scale value, 90
ERR72 300V
voltmeter direct input, 300V end scale value, 90
ERIL72 500V
voltmeter direct input, 500V end scale value, 240
ERIL96 10A5
ammeter direct input, 10/50A end scale value, 240 5In
MEDIUM WEIGHT (kg):
ERR48 (0,10) ERR72 (0,20)
ERR96 (0,25) ERR144 (0,35)
ERIL48 (0,21) ERIL72 (0,30)
ERIL96 (0,40) ERIL144 (0,45)
For connection diagram see page 139
TACHOMETER INDICATORS
ERCT48D - ERCT72D - ERCT96D - ERCT144D (for VDC tacho generator, 90)
ERCT48A - ERCT72A - ERCT96A - ERCT144A (for VAC tacho alternator, 90)
ERCTL48D - ERCTL72D - ERCTL96D - ERCTL144D (for VDC tacho generator, 240)
ERCTL48A - ERCTL72A - ERCTL96A - ERCTL144A (for VAC tacho alternator, 240)
These instruments are moving coil and have an incorporated potentiometer, they are suitable for measuring
the number of revolutions on a tacho generator (VDC) or tacho alternator (VAC)
BURDEN
600A
ACCURACY CLASS
1,5
When ordering, indicate the scale, unit of measurement, input voltage and number of revolutions.
EXAMPLES WHEN ORDERING
ERCT72D 10VDC 1500G/min
indicator for tacho generator where 1500 revs per minute correspond to
10 VDC, 90 scale plate
ERCTL96A 10VCA 100l/h
indicator for tacho alternator where 100 litres per hour correspond to
10 VAC, 240 scale plate
MEDIUM WEIGHT(kg):
ERCT48 (0,10) ERCT72 (0,20) ERCT96 (0,25) ERCT144 (0,35)
ERCTL48 (0,21) ERCTL72 (0,30) ERCTL96 (0,40) ERCTL144 (0,45)
For connection diagram see page 139
122
TEMPERATURE INDICATORS
ERT72 - ERT96 (90 scale plate)
ERTL72 - ERTL96 (240 scale plate)
Instruments with moving coil system of high sensitivity provided with internal potentiometer for line
compensation. They are used for measuring the temperature by means of a 500 C thermocouple.
BURDEN
600A
ACCURACY CLASS
1,5
Measurement of the T
CAPACITIES
Fe/CuNi (Fe-Const). Ra max
0-600 C
20 Ohm
0-900 C
20 Ohm
NiCr/Ni
Ra max
0-600 C
20 Ohm
0-900 C
20 Ohm
Ra=Line resistance + thermocouple
0-1200C
20 Ohm
PtRh/Pt
Ra max
0-1200C
20 Ohm
0-1600C
20 Ohm
EXAMPLES WHEN ORDERING
ERT72 600C Fe/CuNi
Scale temperature reading: 600C for Ferro-Constantana probe
90 Scale plate
ERTL96 900C NiCr/Ni
Scale temperature reading: 900 for NickelChrome-Nickel probe
240 Scale plate
MEDIUM WEIGHT (kg):
ERT72 (0,20)
ERT96 (0,25)
ERTL72 (0,30)
ERTL96 (0,40)
For connection diagram see page 139
123
100V = 1,5VA
230V = 3 VA
400V = 4 VA
ACCURACY CLASS
0,5
The difference between the periods of vibration of two adjoining reeds is 0,5 or 1 Hz. In the case of two
adjoining reeds vibrating with the same amplitude, the measuring of the frequency will be averaged between
the vibration periods of both reeds. If the 50 and 50,5Hz reeds vibrate with the same amplitude, for example,
the frequency measured will be 50.25Hz.
Reading example:
CAPACITIES
47/53Hz 100V / 230V / 400V 13 reeds (for types ERFV 72/96/144)
57/63Hz 100V / 230V / 400V
13 reeds (for types ERFV 72/96/144)
45/55Hz 100V / 230V / 400V
21 reeds (for types ERFV 96/144)
55/65Hz 100V / 230V / 400V
21 reeds (for types ERFV 96/144)
Different capacities can be carried out on request
EXAMPLES WHEN ORDERING
ERFV72 230V 47-53
frequency meter 72x72, 230V aux supply with 13 vibrating reeds and a
47/53Hz capacity
ERFV96 400V 45-55
frequency meter 96x96, 400V aux supply with 21 vibrating reeds and a
45/55Hz capacity
MEDIUM WEIGHT (kg):
ERFV72 (0,25) ERFV96 (0,30)
ERFV144 (0,35)
For connection diagram see page 139
120%
12
18
24
30
36
48
60
72
100%
80
120
125
150
200
250
300
400
120%
96
120
150
180
240
300
360
480
100%
500
600
750
800
1000
1200
1500
2000
120%
600
720
900
960
1200
1400
1800
2400
100%
2500
3000
4000
5000
120%
3000
3600
4800
6000
124
120%
12
18
24
30
36
48
60
72
200%
20
30
40
50
60
80
100
120
100%
80
100
150
200
250
300
400
500
120%
96
120
180
240
300
360
480
600
200%
160
200
300
400
500
600
800
1000
100%
600
800
1000
1200
1500
2000
2500
3000
120%
720
960
1200
1400
1800
2400
3000
3600
200%
1200
1600
2000
2400
3000
4000
5000
6000
100%
4000
5000
120%
4800
6000
200%
8000
10000
ELECTRONIC SYNCHRONOSCOPES
ERSI96
These instruments are intended for measuring phase difference between a bus-bar and a generator.They
are provided with a synchronising check relay which enables switch-on of synchronisation when the set
parameters are reached. These instruments are equipped with a circular display of phase angle which
consists of 18 leds.Momentary phase difference is displayed by led. Within synchronisation range (=0
between -15el and +15el) resolution is increased to 5el. If difference of frequency between input voltages
exceeds 3Hz, three leds above FAST (fgen > frete) or SLOW (fgen < frete) inscription are alternately illuminated.
A green SYNC. LED is illuminated when synchronisation conditions are made.
A red U led is illuminated when difference between voltages is above the set value or when the bus-bar
voltage is lower then 80% of nominal value Un. In these instruments comparison of the input voltage of
generator Ugen and net Unet method is used ,through and A/D converter of the microprocessor.The input
voltages are galvanically insulated by a transformer and a microprocessor controls all the operations of the
synchronoscope verifying the values of the input voltages coming from the A/D converter, determining the
difference of phase () between generator and net. The synchronoscopes are provided with three
potentiometers for settting conditions of a synchronisation relay switch-on at the instrument rear side: for
setting permitted phase difference , for setting permitted voltage difference U, for a delay of
synchronisation relay switch-on (DELAY). When phase difference and voltage difference between a generator
and bus-bar for time of delay of synchronisation check relay are within the set limits, the synchronisation
check relay is switched on for approx 150ms. In that time the SYNC. Led is illuminated as well.
INPUT VOLTAGE TECHNICAL DATA
57, 100, 230, 400 V (to be specified when ordering)
- Nominal voltage Un:
- Voltage range:
Un +/-20%
- Frequency range:
45/65 Hz
- Burden (bus-bar):
<4 VA
- Overload:
1,2 Un continuously
2 Un for 3 seconds
MEASURING SECTION TECHNICAL DATA:
- Resolution of phase difference display: 20 el.
- Magnification range:
15 el.
- Magnification resolution:
5 el.
- Accuracy class (=0)
3 el.
SYNCHRONISATION SECTION
- Voltage difference setting range
from 1 to 10%
accuracy class 2,5 %
- Phase difference setting range
from 2 to 20 el.
accuracy class 3 el.
- Switch-on delay time range
from 0,1 to 1 sec accuracy class 10%
- Relay:
N.O. 250V/50Hz, 6A - impulse duration 120ms
EXAMPLES WHEN ORDERING
ERSI96 400V
Synchronoscope with output relay, aux supply 400V
WEIGHT (kg):
0,45
For connection diagram see page 139
125
DOUBLE VOLTMETERS
ERI96D
These instruments consist of two equipments mounted on a common axis permitting the two pointers
indicating on one graduation. In this way there is the immediate comparison of the parallel adjustment. The
moving coil system reduces drastically the burden and permits linear graduations.
BURDEN
1,5VA
OPERATING FREQUENCY
45/65 Hz
ACCURACY CLASS
1,5
STANDARD CAPACITY
2x500V
Different capacities can be carried out on request
EXAMPLES WHEN ORDERING
ERI96D 500V
double voltmeter, 2x500V end scale value
WEIGHT (kg):
0,42
For connection diagram see page 145
ERS72 (0,20)
126
ERS96 (0,30)
ZEROVOLTMETER
ERZ48 - ERZ72 - ERZ96 - ERZ144 (90 scale plate)
ERZL48 - ERZL72 - ERZL96 - ERZL144 (240 scale plate)
BURDEN
1 mA
These instruments consist of moving coil movements with internal rectifier which can be used to replace the
Sinchronoscope in the synchronizing of two generators or one generator in the network. When the two
voltages to be synchronized are the same, the instrument indicates zero.
STANDARD CAPACITIES
from 0 to 50V, extended as far as 800V
(The instrument can therefore be used with all the voltages
as the equipment withstands up to 800V continuously)
EXAMPLES WHEN ORDERING
ERZ48 50V-800V
zerovoltmeter 48x48, 90 end scale value
ERZL96 50V-800V
zerovoltmeter 96x96, 240 end scale value
WEIGHT (kg)
ERZ144 (0,30)
ERZL144 (0,40)
ERZS144 (0,30)
ERZSL144 (0,40)
INPUT CURRENT
5A
127
These measure consist of a 1mA direct current instrument (ERC-ERCL) for use with an external multi-voltage
accessory (1CORFP10). They have been produced separately to permit the reading of the cos with
instruments of various designs other than 96x96 mm
STANDARD CAPACITY
0,5-1-0,5 cos
TECHNICAL DATA
ERC-ERCL
1CORFP10
see page 122
- Auxiliary power supply (separate): 230V AC
- Nominal input values:
voltage: 230V AC
current: 5A (1A on types 1CORFP10...B)
- Output nominal values: (selectable):
1 - 5 - 10 - VDC and 1 - 5 - 10 - 20 - 4/20 mA DC
1 mA DC degrees value for connection with analogue instruments
- Conversion type:
proportional to the phase angle
- Resistive load: 700
- Measuring range: 0,5 (cap) - 1 - 0,5 (ind) standard
- Accuracy class: 0,5
- Overload:
Permanent 2 In / 1,2 Un
Instantaneous 10 In / 2 Un for 1 sec
- Operating frequency: 50 / 60 Hz
- Response time: 300 ms
- Alternated residual: 1%
- Burden: voltage 1VA current 0,8VA aux supply 4VA
- Galvanic separation between inputs and outputs:
insulation between inputs and outputs, aux supply 2kV for 1min at 50Hz
insulation between all circuits and earth: 4kV for 1min at 50Hz
- Operating temperature: 0 C +55 C
EXAMPLES WHEN ORDERING
ERC72+1CORFP10 230V
single phase meter, aux supply 230V;
5A input current and 0,5-1-0,5 scale plate
An ERC72 instrument 1mA will be provided with a 0,5-1-0,5 cos scale plate and a 1CORFP10 accessory on
which should be connected the terminals corresponding to 230V
When testing it is necessary to apply
a minimum load of 10% if not the
instrument will not indicate
any value
For connection diagram see page 140
These measure consist of a 1mA direct current instrument (ERC-ERCL) for use with an external multi-voltage
accessory (1CORFP20). They have been produced separately to permit the reading of the cos with
instruments of various designs other than 96x96 mm
STANDARD CAPACITY
0,5-1-0,5 cos
TECHNICAL DATA
ERC-ERCL
1CORFP20
see page 122
- Auxiliary power supply (separate): 230V /400V AC
- Nominal input values:
voltage: 400V AC
current: 5A (1A on types 1CORFP20...B)
- Output nominal values: (selectable):
1 - 5 - 10 - VDC and 1 - 5 - 10 - 20 - 4/20 mA DC
1 mA DC degrees value for connection with analogue instruments
- Conversion type:
proportional to the phase angle
- Resistive load: 700
- Measuring range: 0,5 (cap) - 1 - 0,5 (ind) standard
- Accuracy class: 0,5
- Overload:
Permanent 2 In / 1,2 Un
Instantaneous 10 In / 2 Un for 1 sec
- Operating frequency: 50 / 60 Hz
- Response time: 300 ms
- Alternated residual: 1%
- Burden: voltage 1VA current 0,8VA aux supply 4VA
- Galvanic separation between inputs and outputs:
insulation between inputs and outputs, aux supply 2kV for 1min at 50Hz
insulation between all circuits and earth: 4kV for 1min at 50Hz
- Operating temperature: 0 C +55 C
EXAMPLES WHEN ORDERING
ERC48+1CORFP20 400V
three phase meter, aux supply 400V;
5A input current and 0,5-1-0,5 scale plate
An ERC48 instrument 1mA will be provided with a 0,5-1-0,5 cos scale plate and a 1CORFP20 accessory on
which should be connected the terminals corresponding to 400V
When testing it is necessary to apply
a minimum load of 10% if not the
instrument will not indicate
any value
For connection diagram see page 141
128
0,5-1-0,5 cos
INPUT CURRENT
5A
ERFA96/2 (0,45)
ERFAL96/2 (0,50)
129
Active power
P(W)=U(V)xI(A)xcos
Reactive power
P(Var)=U(V)xI(A)xsen
_
P(W)=U(V)xI(A)x3 cos
_
P(Var)=U(V)xI(A)x3 sen
where U = nominal value of the voltage (or primary of the voltage transformer)
I = primary value of the current transformer
if the cos is not indicated, it is believed by us to be between 0,7 and 0,9.
Example:
P(W)= 1.500x500x1,73=1,3 MW
1,3 MWx0,7=0,91 MW
1,3 MWx0,9=1,17 MW
In the case of our example, by way of standardising scale value one can choose between the following
values: 1 MW or 1,2 MW.
EXAMPLES WHEN ORDERING
ERW96/14 400V 100/5A 80KW
ERW96/21 100V 500/5A 100KW
ERV96/42 230V 25/5A
10KVAR
ERW96 (0,58)
ERWL96 (0,65)
130
ERV96 (0,58)
ERVL96 (0,65)
1000 W (VAR)
2000 W (VAR)
3000 W (VAR)
4000 W (VAR)
5000 W (VAR)
6000 W (VAR)
8000 W (VAR)
10 KW (KVAR)
12 KW (KVAR)
16 KW (KVAR)
20 KW (KVAR)
30 KW (KVAR)
40 KW (KVAR)
50 KW (KVAR)
60 KW (KVAR)
80 KW (KVAR)
100 KW (KVAR)
120 KW (KVAR)
160 KW (KVAR)
200 KW (KVAR)
300 KW (KVAR)
400 KW (KVAR)
500 KW (KVAR)
2000 W (VAR)
4000 W (VAR)
6000 W (VAR)
8000 W (VAR)
10 KW (KVAR)
12 KW (KVAR)
16 KW (KVAR)
20 KW (KVAR)
24 KW (KVAR)
32 KW (KVAR)
40 KW (KVAR)
60 KW (KVAR)
80 KW (KVAR)
100 KW (KVAR)
120 KW (KVAR)
160 KW (KVAR)
200 KW (KVAR)
240 KW (KVAR)
320 KW (KVAR)
400 KW (KVAR)
600 KW (KVAR)
800 KW (KVAR)
1000 KW (KVAR)
2000 W (VAR)
4000 W (VAR)
6000 W (VAR)
8000 W (VAR)
10 KW (KVAR)
12 KW (KVAR)
16 KW (KVAR)
20 KW (KVAR)
24 KW (KVAR)
32 KW (KVAR)
40 KW (KVAR)
60 KW (KVAR)
80 KW (KVAR)
100 KW (KVAR)
120 KW (KVAR)
160 KW (KVAR)
200 KW (KVAR)
240 KW (KVAR)
320 KW (KVAR)
400 KW (KVAR)
600 KW (KVAR)
800 KW (KVAR)
1000 KW (KVAR)
4000 W (VAR)
8000 W (VAR)
12 KW (KVAR)
16 KW (KVAR)
20 KW (KVAR)
24 KW (KVAR)
32 KW (KVAR)
40 KW (KVAR)
48 KW (KVAR)
64 KW (KVAR)
80 KW (KVAR)
120 KW (KVAR)
160 KW (KVAR)
200 KW (KVAR)
240 KW (KVAR)
320 KW (KVAR)
400 KW (KVAR)
480 KW (KVAR)
640 KW (KVAR)
800 KW (KVAR)
1200 KW (KVAR)
1600 KW (KVAR)
2000 KW (KVAR)
In order to achieve the above, the various converters have been calibrated as follows:
For the Active Power:
100V, 5A=500W
230V, 5A=1000W 400V, 5A=2000W
100V, 5A=1000W
without neutral,
without neutral,
with neutral,
with neutral,
3 wires
3 wires (ARON)
4 wires
4 wires
100V, 5A=1000VAR 230V, 5A=2000W 400V, 5A=4000VAR in the system: Balanced three phase
Unbalanced threephase
Balanced threephase
Unbalanced threephase
without neutral,
without neutral,
with neutral,
with neutral,
3 wires
3 wires (ARON)
4 wires
4 wires
131
DIMENSIONS in mm
Weight: 0,65 Kg
1COR
132
GENERAL NOTES
There is, pratically an unlimited variety of applications regarding electronic regulators.
They are used for regulating and checking all those parameters which can be measured by an electrical instrument, both directly and by means
of a converter.
These instruments offer a wide range of uses when there is a need for analogue signals, controls, automatic adjustments, protection, automatic
process checks, etc.
They have two adjustment channels which can be used one at a time or together and each channel has a potentiometer and a graduation in %
of the scale (the scale value on the instrument corresponds to 100% on the graduated disc) and this adjustment can be carried out along the
entire length of the scale.
The diodes on the scale indicate whether the reading has been carried out inside or outside the limits of the scale limits.
These instruments also have two timing circuits, one per channel, which make it possible to delay the exit signal when the user does not want
the pick-up currents to be indicated.
The timer immediately returns to zero and, should the indicator oscillate, these various times are not totalled together.
When the timing of the signal is not necessary it is sufficient to place the potentiometer on point 0 for the instrument to immediately operate.
TECHNICAL CHARACTERISTICS
GENERAL NOTES
SUPPLY VOLTAGE
INFLUENCE OF THE SUPPLY VOLTAGE
BURDEN
RELAYS
MAXIMUM INTERRUPTION POWER WITH RESISTIVE LOAD
CHANNEL I EXIT
CHANNEL II EXIT
SIGNALING APPARATUS
Adjustments by means of knob on the back of the instruments
CLASS
ADJUSTMENT EXAMPLES
As the two potentiometers are independent, either of them can be used for any value of the scale.
min/max
min/min
max/max
MAX II
MIN I
MAX II
MAX II
CONTACT
INSTRUMENT
LIMIT SIGNAL
MONITOR
CONTACT
INSTRUMENT
LIMIT SIGNAL
MONITOR
MIN I
MAX II
MAX II
CONTACT
INSTRUMENT
MIN I
LIMIT SIGNAL
MONITOR
MIN I
MAX II
MIN I
MIN I
MIN I
MAX II
MAX II
MAX II
CONTACT
INSTRUMENT
LIMIT SIGNAL
MONITOR
MAX II
CONTACT
INSTRUMENT
MIN I
LIMIT SIGNAL
MONITOR
MIN I
MIN I
MAX II
CONTACT
INSTRUMENT
MIN I
LIMIT SIGNAL
MONITOR
MIN I
MAX II
Note: Channel I corresponds to the minimum contact,the potentiometer of which, if not used, should be set on the 0% point
Channel II corresponds to the maximum contact,the potentiometer of which, if not used, should be set on the 100% point
133
FREQUENCY METERS
ERFC96
BURDEN
3VA
POWER SUPPLY
220V +/-10% at 45/65Hz
INFLUENCE OF POWER SUPPLY
< 0,2% for +/-10%Vn
STANDARD CAPACITY
45/65Hz
Different capacities can be carried out on request
EXAMPLES WHEN ORDERING
ERFC96 45/65Hz 220V
Frequency with end scale value 45/65Hz
For the connection diagram please see page 145
134
These instruments are made up of a 1mA direct current instrument (ERCC) and by an external multi-voltage
accessory (1CORFP10).
STANDARD CAPACITY
0,5-1-0,5 cos
TECHNICAL DATA
ERCC
1CORFP10
see above
- Auxiliary power supply (separate): 230V AC
- Nominal input values:
voltage: 230V AC
current: 5A (1A on types 1CORFP10...B)
- Output nominal values: (selectable):
1 - 5 - 10 - VDC and 1 - 5 - 10 - 20 - 4/20 mA DC
1 mA DC degrees value for connection with analogue instruments
- Conversion type:
proportional to the phase angle
- Resistive load: 700
- Measuring range: 0,5 (cap) - 1 - 0,5 (ind) standard
- Accuracy class: 0,5
- Overload:
Permanent 2 In / 1,2 Un
Instantaneous 10 In / 2 Un for 1 sec
- Operating frequency: 50 / 60 Hz
- Response time: 300 ms
- Alternated residual: 1%
- Burden: voltage 1VA current 0,8VA aux supply 4VA
- Galvanic separation between inputs and outputs:
insulation between inputs and outputs, aux supply 2kV for 1min at 50Hz
insulation between all circuits and earth: 4kV for 1min at 50Hz
- Operating temperature: 0 C +55 C
EXAMPLES WHEN ORDERING
ERCC96+1CORFP10 230V single phase meter, aux supply 230V; 5A input current and 0,5-1-0,5 scale plate
An ERCC96 instrument 1mA will be provided with a 0,5-1-0,5 cos scale plate
and a 1CORFP10 accessory on which should be connected the terminals
corresponding to 230V
When testing it is necessary to apply
a minimum load of 10% if not the
instrument will not indicate
any value
For connection diagram see page 140
These instruments are made up of a 1mA direct current instrument ( ERCC) and by an external multi-voltage
accessory (1CORFP20).
STANDARD CAPACITY
0,5-1-0,5 cos
TECHNICAL DATA
ERCC
1CORFP20
see page 136
- Auxiliary power supply (separate): 230V /400V AC
- Nominal input values:
voltage: 400V AC
current: 5A (1A on types 1CORFP20...B)
- Output nominal values: (selectable):
1 - 5 - 10 - VDC and 1 - 5 - 10 - 20 - 4/20 mA DC
1 mA DC degrees value for connection with analogue instruments
- Conversion type:
proportional to the phase angle
- Resistive load: 700
- Measuring range: 0,5 (cap) - 1 - 0,5 (ind) standard
- Accuracy class: 0,5
- Overload: Permanent 2In / 1,2Un - Instantaneous 10In / 2Un for 1 sec
- Operating frequency: 50 / 60 Hz
- Response time: 300 ms
- Alternated residual: 1%
- Burden: voltage 1VA current 0,8VA aux supply 4VA
- Galvanic separation between inputs and outputs:
insulation between inputs and outputs, aux supply 2kV for 1min at 50Hz
insulation between all circuits and earth: 4kV for 1min at 50Hz
- Operating temperature: 0 C +55 C
EXAMPLES WHEN ORDERING
ERCC96+1CORFP20 400V three phase meter, aux supply 400V; 5A input current and 0,5-1-0,5 scale plate
An ERCC96 instrument 1mA will be provided with a 0,5-1-0,5 cos scale plate
and a 1CORFP20 accessory on which should be connected the terminals
corresponding to 400V
When testing it is necessary to apply
a minimum load of 10% if not the
instrument will not indicate
any value
For connection diagram see page 141
TECHNICAL DATA
ERCC
see page 136
135
+
CONNECTION DIAGRAMS
L1
L2
L3
Fuse
2A
Fuse
7 8
TVR.../100V AC
WITHOU switch
Fuse
Power supply
100VAC 10%, 50/60 Hz
1RAMI
Switch
L1
0
L2
L3
Fuse
2A
L1
L2
L3
Fuse
7 8
TVR.../100V AC
WITH switch
Fuse
Power supply
100VAC 10%, 50/60 Hz
1RAMI
136
S1
S2
P1
+
-
L1
N
ERI...C
Direct input
ERPI - EMI - ERI - ERIVH
ERR - ERIL - ERRL - ERPC
EMC - ERC - ERCL - ERZS
ERZSL - ERFV - ERFVd
ERF - ERFL - 4RK - 4RH
P2
L1
N
Input by means of C.T.
ERI...C
Voltmeters with incorporated
switch
L1
L2
L3
S1
S2
P1
P2
S1
S2
P1
P2
S1
S2
P1
P2
DC ammeters
+
Input by means of Shunt
ERZ - ERZL
Zerovoltmeters
AC Voltmeters
AC / DC voltmeters,
Suppressed zero voltmeters
Frequencymeters
Hourmeters
+
-
L
L (N)
L1
L2
L3
N
L
L (N)
Input by means of V.T.
Direct input
ERS
ERT - ERTL
Sequence meters
Temperature indicators
L1
L2
L3
G
Generator
ERCT - ERCTL
Tachometers indicators
ERSI96
Syncronoscopes
SYNC
GEN
L2 L1
L1
L2
L3
G
Probe
Tacho
Generator
BUS BAR
L2 L1
L1
L2
L3
Generator
139
ERFA96/1 - ERFAL96/1
Single phase Power Factor meters
Note: Any operation necessary for installing these
instruments must take place in the absolute absence
of voltage, as there is no insulation between line and
instrument
Terminals
11
11
direct input
+1
L1
11
Terminals
input by means of
C.T. (.../5A)
L1
N
Terminals
S1
S2
P1
P2
11
L1
N
L1
N
S1
S2
S1
S2
P1
P2
P1
P2
ERFA96/2 - ERFAL96/2
Three phase, balanced load without neutral,
Power Factor meters
Note: Any operation necessary for installing these
instruments must take place in the absolute absence
of voltage, as there is no insulation between line and
instrument
Terminals
direct input
+1
L1
L2
L3
3
5
8
Terminals
input by means of
C.T. (.../5A)
L1
L2
L3
Terminals
L1
L2
L1
L2
L3
L3
S1
S2
P1
P2
S1 S2
S1
S2
P1 P2
P1
P2
Terminals
19
19
230V
45-65 Hz
1mA DC
1mADC
220 V
400V
direct input
L1
13 14
22 23 24
20
Terminals
input by means of
C.T. (.../5A)
5A
OFF
ON
1 2 3 4 5 6 1 2 3 4
140
L1
N
L1
N
S1
S2
P1
P2
Terminals
input by means of
C.T. (.../5A) and
V.T. (.../100V)
L1
N
S1
S2
P1
P2
S1
S2
S1
S2
P1
P2
P1
P2
19
230V
220 V
45-65 Hz
1mA DC
1mADC
10
12
10
12
10
12
400V
direct input
L1
L2
L3
13 14
22 23 24
Terminals
input by means of
C.T. (.../5A)
L1
L2
L3
10
Terminals
5A
L1
L2
L3
OFF
ON
S2
P1
P2
S1
S2
P1
P2
S1 S2
S1
S2
P1 P2
P1
P2
1 2 3 4 5 6 1 2 3 4
ERW96/1 - ERWL96/1
ERV96/1 - ERVL96/1
Terminals
11
11
direct input
+1
L1
11
Terminals
input by means of
C.T. (.../5A)
L1
N
Terminals
L1
N
L1
N
S1
S2
P1
P2
S1
S2
S1
S2
P1
P2
P1
P2
11
ERW96/2 - ERWL96/2
Three phase, balanced load, 3 wires without neutral,
Wattmeters
Note: Any operation necessary for installing these
instruments must take place in the absolute absence of
voltage, as there is no insulation between line and
instrument
Terminals
direct input
L1
L2
L3
+1
Terminals
3
2
input by means of
C.T. (.../5A)
L1
L2
L3
Terminals
S1
S2
P1
P2
L1
L2
L3
L1
L2
L3
S1 S2
S1
S2
P1 P2
P1
P2
141
ERV96/2 - ERVL96/2
Three phase, balanced load, 3 wires without neutral,
Varmeters
Note: Any operation necessary for installing these
instruments must take place in the absolute
absence of voltage, as there is no insulation
between line and instrument
Terminals
direct input
+1
L1
L2
L3
3
5
Terminals
input by means of
C.T. (.../5A)
L1
L2
L3
Terminals
L1
L2
L3
L1
L2
L3
ERW96/3 - ERWL96/3
Three phase, unbalanced load, 3 wires without
neutral (ARON), Wattmeters and Varmeters
Note: Any operation necessary for installing these
instruments must take place in the absolute
absence of voltage, as there is no insulation
between line and instrument
S1
S2
P1
P2
S1 S2
S1
S2
P1 P2
P1
P2
ERV96/3 - ERVL96/3
Terminals
direct input
+1
3
2
9
8
L1
L2
L3
Terminals
input by means of
C.T. (.../5A)
L1
L2
L3
Terminals
S1
S2
P1
P2
L2
L3
S1 S2
S1
S2
P1 P2
P1
P2
ERW96/4 - ERWL96/4
Three phase, balanced load, 4 wires with neutral,
Wattmeters
Note: Any operation necessary for installing these
instruments must take place in the absolute absence of
voltage, as there is no insulation between line and
instrument
Terminals
11
11
direct input
L1
L2
+1
L3
N
3
5
Terminals
input by means of
C.T. (.../5A)
L1
S1
S2
P1
P2
L2
L3
N
Terminals
input by means of C.T.
(.../5A) and V.T. (.../100V)
S1
S2
P1
P2
L1
142
L2
L1
L3
N
L3
L2
N
11
ERV96/4 - ERVL96/4
Three phase, balanced load, 4 wires with neutral,
Varmeters
Note: Any operation necessary for installing these
instruments must take place in the absolute
absence of voltage, as there is no insulation
between line and instrument
Terminals
direct input
+1
L1
L2
L3
Terminals
input by means of
C.T. (.../5A)
S1 S2
P1 P2
L1
L2
L3
N
Terminals
L1
L2
L1
S1 S2
P1 P2
L2
L3
N
L3
N
ERW96/5 - ERWL96/5
Three phase, unbalanced load, 4 wires with
neutral, Wattmeters
Three phase, unbalanced load, 4 wires with
neutral, Varmeters
Note: Any operation necessary for installing
these instruments must take place in the
absolute absence of voltage, as there is no
insulation between line and instrument
ERV96/5 - ERVL96/5
Terminals
1 2 3 4 5 6 7 8 9 11
direct input
L1
L2
7
9
3
2
L3
N
11
Terminals
1 2 3 4 5 6 7 8 9 11
input by means of
C.T. (.../5A)
L1
S1
S2
S1
S2
S1
S2
P1
P2
P1
P2
P1
P2
L2
L3
N
Terminals
input by means of C.T.
(.../5A) and V.T. (.../100V)
L1
L2
L3
L1
1 2 3 4 5 6 7 8 9 11
S1
S2
S1
S2
S1
S2
P1
P2
P1
P2
P1
P2
19
19
L2
L3
1CORPA1 (1CORPR1) + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Single phase Wattmeters
Single phase Varmeters
(1CORPA1 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
(1CORPR1 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
400V
1 mA DC
+
45-65 Hz
230V
direct input
C
16 17
L1
+
19
21
23 24
Terminals
input by means of
C.T. (.../5A)
1
L1
N
S1
S2
P1
P2
L1
N
Terminals
230V
220 V
1mA DC
1mADC
Terminals
L1
N
S1
S2
S1
S2
P1
P2
P1
P2
19
143
1CORPA2 (1CORPR2) + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, balanced load, 3 wires without neutral, Wattmeters (1CORPA2 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96 Terminals
Three phase, balanced load, 3 wires without neutral, Varmeters (1CORPR2 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
400V
1mADC
220 V
45-65 Hz
230V
10
12
10
12
10
12
L1
L2
L3
16 17
23 24
21
Terminals
input by means of
C.T. (.../5A)
1
direct input
1 mA DC
+
10
12
L1
L2
L3
S1
S2
P1
P2
Terminals
230V
1mA DC
L1
L2
L3
L1
L2
L3
S1 S2
S1 S2
S1
S2
P1 P2
P1 P2
P1
P2
1CORPA3 (1CORPR3) + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, unbalanced load (ARON), 3 wires without neutral, Wattmeters
(1CORPA3 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, unbalanced load (ARON), 3 wires without neutral, Varmeters
(1CORPR3 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Terminals
400V
1mADC
220 V
45-65 Hz
19
23 24
21
Terminals
input by means of
C.T. (.../5A)
1
10
L1
L2
L3
12
Terminals
L1
L2
L3
230V
1mA DC
19
1 8
2 10 5 12
19
L1
L2
L3
16 17
2 10 5 12
direct input
230V
C
1 mA DC
+
1 8
L1
L2
L3
S1
S2
S1
S2
P1
P2
P1
P2
1 8
2 10 5 12
S1 S2
S1 S2
S1
S2
S1
S2
P1 P2
P1 P2
P1
P2
P1
P2
1CORPA4 (1CORPR4) + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, balanced load, 4 wires with neutral, Wattmeters (1CORPA4 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, balanced load, 4 wires with neutral, Varmeters (1CORPR4 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Terminals
19
19
19
direct input
400V
1mADC
220 V
45-65 Hz
1 mA DC
+
16 17
L1
L2
L3
N
230V
C
21
19
23 24
Terminals
input by means of
C.T. (.../5A)
L1
L2
L3
N
144
230V
1mA DC
L1
L2
L3
N
Terminals
S1
S2
P1
P2
S1 S2
S1
S2
P1 P2
P1
P2
19
1CORPA5 (1CORPR5) + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, unbalanced load, 4 wires with neutral, Wattmeters (1CORPA5 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
Three phase, unbalanced load, 4 wires with neutral, Varmeters (1CORPR5 + ERC48 (72, 96, 144) / 2RCD36 (48, 72, 96) / ERCC96
400V
220 V
45-65 Hz
direct input
8 2 3
10 4 5
12 6 19
8 2 3
10 4 5
12 6 19
L1
L2
L3
N
1 mA DC
+
1mADC
230V
Terminals
16 17
Terminals
23 24
21
19
input by means of
C.T. (.../5A)
10
Terminals
S1
S2
S1
S2
P2
P1
P2
P1
P2
8 2 3
10 4 5
12 6 19
S1 S2
S1 S2
S1 S2
S1
S2
S1
S2
S1
S2
P1 P2
P1 P2
P1 P2
P1
P2
P1
P2
P1
P2
L1
L2
L3
N
230V
1mA DC
S2
P1
L1
L2
L3
N
12
L1
L2
L3
N
S1
ERI96D - ERF96D
Double voltmeter
Double frequencymeter
L1
L2
L3
L1
L2
L3
ERIC96 - ERCC96
ERIC96 - ERCC96
AC ammeters (ERIC96)
DC ammeters (ERCC96)
220 V
45-65 Hz
ERFC
AC voltmeters (ERIC96)
DC voltmeters (ERCC96)
_
+
220 V
45-65 Hz
Frequencymeter
_
+
220 V
60-500V ~
45-65 Hz
145