High Flow /High Pressure

maximum 3750 PSIG (brass), 4500 PSIG (SST) in


ranges: 0 - 1500 PSIG out
pressure reducing

44-1300 Series

Specifications
Operating Parameters
pressure rating per criteria of ANSI/ASME B31.3
maximum operating pressure:
stainless steel body . . . . . . . . . . . . . 4,500 PSIG
brass body . . . . . . . . . . . . . . . . . . . 3,750 PSIG
outlet pressure ranges . . . . . . . . . . . . . 0-300, 0-600,
0-1000 & 0-1500 PSIG
design proof pressure . . . . 150% of rated pressure
leakage . . . . . . . . . . . . . . . . . . . . . . . . bubble-tight
operating temperature 1 . . . . . . -15 F to +220 F
(-25 C to +104 C)
flow capacity: 2
1/4" main valve . . . . . . . . . . . . . . . . . . C v = 0.8
3/8" main valve . . . . . . . . . . . . . . . . . . C v = 2.0
1 For extended temperatures from -65F to +400F, consult factory.
2 A secondary pressure drop due to the outlet cross-hole can
significantly affect the rated flow capacity. Flow curves should be
used for critical sizing applications.

Media Contact Materials


body . . . . . . . . . brass, 303 or 316 Stainless Steel
seat, main valve:
300 PSIG outlet . . . . . . . . . . . . . . . . . . . Teflon
600, 1000 & 1500 outlet . . . . . . . . . . . . . . CTFE
seat, vent valve:
300 & 600 PSIG outlet . . . . . . . . . . . . . . Teflon
1000 & 1500 PSIG outlet . . . . . . . . . . . . . CTFE
o-rings . . . . . . . . . . . . . . . . . . . . . . . . . . Viton-A
back-up rings . . . . . . . . . . . . . . . . . . . . . . Teflon
gaskets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTFE
remaining parts . . . . . . 300 Series Stainless Steel,
17-4, 17-7 Stainless Steel, Teflon & Brass
For other materials and modifications, please consult factory.

Cleaning . . . . . . . . . . . . CGA 4.1 and ASTM G93

Dome Loaded

Spring Loaded

Air Loaded

Advantages
Large piston sensor gives excellent
sensitivity
Balanced valve design assures stable
downstream pressure
Large handknob provides fast low-torque
pressure settings
Self-venting standard
Available with optional gauge ports,
Dome and Air loaded
Optional 6000 or 5000 PSIG inlet with
2500 PSIG outlet

Weight (without gauges) . . . . . . . 6.25 lbs. (2.83 kg)


Pressure Conversion

14.5 PSIG = 1 bar 145 PSIG = 1 MPa

Teflon and Viton-A are registered trademarks of Du Pont.

Global technical support & distribution Design & manufacturing facilities in the U.S.A. & Germany

44-1300 Series

High Flow/High Pressure


Flow Charts
44-1300 (Cv .8) Series Curves
44-13X6-2081 & 44-13X5-2081

C v =.8

Standard

OUTLET PRESSURE - PSIG

1500

- 0 0 5 Modification

no gauge ports

with gauge ports

1400
1300
1200
1100
1000

2000 PSIG INLET

900
800
700

2000

600

3000

500
400
300
3000

200
100

1000

200
400
600
800 1000 1200 1400 1600 1800 2000
(5663) (11326) (16989) (22652) (28315) (33978) (39641) (45304) (50967) (56630)

FLOW RATE - SCFM (LPM) Air


44-1300 (Cv 2.0) Series Curves

C v =2.0

44-13X5-2122 & 44-1316-2122

OUTLET PRESSURE - PSIG

1500
1400
1300
1200

3000 PSIG INLET

1100
1000
900

2000

800
700
600

2000

500
400

3000
1000

300
200

2000

3000

100

1000

2000

200
400
600
800 1000 1200 1400 1600 1800 2000 2200 2400
(5663) (11326) (16989) (22652) (28315) (33978) (39641) (45304) (50967) (56630) (62293) (67956)

FLOW RATE - SCFM (LPM) Air

OPTIONS

- 0 5 6 Modification 6000 or 5000 PSIG inlet pressure


with 2500 PSIG outlet pressure
- 0 0 2 Modification Non-venting, no gauge ports
- 0 1 9 Modification Non-venting with gauge ports

All dimensions are reference & nominal


Metric (millimeter) equivalents are in brackets

Part Number Selector


example part number:

44-13

BASIC
SERIES

BODY
MATERIAL

44-13

INLET
PRESSURE

1 Brass
2 303 Stainless Steel
6 316 Stainless Steel

3750 PSIG
4500 PSIG
4500 PSIG

OUTLET
PRESSURE RANGE

2
3
5
6

0-300 PSIG
0-600 PSIG
0-1000 PSIG
0-1500 PSIG

08

PORT TYPE

PORT SIZE

MAIN VALVE

1
2
3
9

SAE
NPT
MS33649
BSP

08 1/2"
12 3/4"

1 1/4"
2 3/8"

Cv = 0.8
Cv = 2.0

Repair Kits, Accessories & Modifications may be available for this product. Please contact factory for more information.

WARNING! Do not attempt to select, install, use or maintain this product until you have read and fully understood the
Tescom Safety, Installation & Operation Precautions.

NOTE: Product availability and specifications contained herein are subject to change without notice. Consult local distributor or factory
for potential revisions and/or service related issues.

INDUSTRIAL CONTROLS DIVISION


Form No. 549

Rev. 10/04

Printed 11/04

800-447-1250 763-241-3238 fax: 763-241-3224


www.tescom.com icd@tescom.com
12616 Industrial Boulevard Elk River, MN 55330 USA
5M