U-Length = ID + B + E
(Convert to inches and enter into OIS boxes 9 through 12)
Craan, Craanford, Gorey, Co. Wexford, Ireland
email: info@measurIT.com, www.measurIT.com
phone: +353 (0) 53 942 8962, fax: +353 (0) 53 942 8963
measurIT technologies
(Convert to inches and enter into OIS boxes 9 through 12) For S Sensor Types Only:
Y = Distance from pipe inside wall to sensing point centerline. (Y = 0.146 x ID).
Z = Distance from sensing point center line to the end of the flow element. (Z = 1.0 in.
[25 mm] for standard temperature instruments and 0.75 inch. [19 mm] for the high
temperature.)
The 2-point configuration show is typically used for 16-inch diameter pipes or larger.
For 36-inch diameter pipes or larger, 3 or 4-point configurations are recommended. (Use
the same factor for calculating “Y” and space the flow elements evenly around the
circumference of the pipe (120 o or 90o apart, respectively.)
2 Address
3 City
4 County
5 Contact Person
6 Title or Department
7 Telephone Number / Extension ( )
8 Fax Number ( )
9 E-mail Address
10
11 Loop or Branch number
Service or Application
PROCESS PIPING DATA
12
13 Pipe or Duct Size / Schedule
14 Wall Thickness
15 Piping Cross-Section Geometry Round Square Rectangle
16 Material
17 Pipe Orientation / Flow Direction Horizontal Vertical, Flow Up Vertical, Flow Down
18 Flow Element Mounting Side Top Bottom
19 Flow Element Process Connection
20
Gas Composition Gas Percent (%)
21 % Volume (moles)
PROCESS MEDIA DATA
22 % Weight (mass)
23
24
25 (Total must add up to 100%)
Minimum Nominal Maximum
26 Operating Temperature
27 Conditions Pressure
28 Flow Rate
29
30 Tag Number(s)
Output Configuration Output #1 Output #2
31 Parameter Flow rate Temperature Flow rate Temperature
SPECIFICATIONS
FLOWMETER
INSTALLATION DIAGRAM
Upstream Distance * Downstream Distance *
F E
Upstream Disturbance * Downstream Disturbance *
MT Flow Element
* How far away are the nearest upstream and downstream flow disturbances and what are they (e.g.; elbow, reducer, tee, valve, blower, etc.)
measurIT technologies Application Data Sheet (ADS)
Craan, Craanford, Gorey, Co. Wexford, Ireland
email: info@measurIT.com, www.measurIT.com
MT86 & MT91
phone: +353 (0) 53 942 8962, fax: +353 (0) 53 942 8963 Insertion Multi-Point Mass Flowmeter
MT Type Code 6.- 8. Process Codes 13. Process Transmitter Options 19. Cable Jacket Notes
Connection 6 7 8 Orientation Code and Length 6 Code
1. Must specify Code 1 in
Analog design; 86 16. Input Power and Box 3.
8 sensing points “M” Sensor For Horizontal Display Code PVC
maximum Configuration Only Pipe or Duct 220°F [104°C] 2. All coatings are over 316
Stainless steel sensors and
All flow assemblies A MT86 without Display maximum temperature assemblies. Only available
Microproces sor 91 2 inch Male NPT N 2 0
based; 16 sensing with Right to Left flow with flange mounted, fixed
100 to 130 Vac 1 10 feet [ 3 m] A insertion length
points maximum ¤ 3 inch, 150 lb Flange 3 F 3 G All flow assemblies B configurations.
per material in Box 5 200 to 270 Vac 2
with Left to Right flow ¤ 50 feet [15 m] B 3. FCI supplied flanges are
¤ 24 Vdc 3 raised face, phonographic
1. Sensor Half flow assemblies C
Configuration Code
“S” Sensor
Configuration Only
with Right to Left flow, ¤ 90 to 110 Vac 4 ¤ 100 feet [30 m] C serrated.
and half with Left to 4. Customer supplied or
Right flow MT86 with Display Teflon 7 specified flange shall be
Two or more sensing M 1 inch Male NPT N1 0
points per flow For Vertical 100 to 130 Vac 5 350°F [177°C] per ANSI or DIN
maximum temperature
element assembly ¤ 1 1/2 inch, 150 lb F BG Pipe or Duct
200 to 270 Vac 6
specifications and shall be
no smaller than 1-1/2
Flange per material inches [DN40] for the “S”
One sensing point S in Box 5 3 Flow up D ¤ 24 Vdc 7 10 feet [ 3 m] E
per flow element Sensor Type or 3 inches
Flow down E
assembly 1
Low Pressure
¤ 90 to 110 Vac 8 ¤ 50 feet [15 m] F [DN80] for the “M” Sensor
Type.
¤ Other * Packing Gland with Customer specified W MT91 with Display
¤ 100 feet [30 m] G 5. Available with MT91 only.
Graphite Material 85 to 265 Vac A
50 psig [3.5 bar(g)] 6. Cable length required for
2. Sensor maximum 14. Local ¤ Other * ¤ Customer specified W each sensing point.
Assembly Code Enclosure Code 7. Teflon is standard for high
¤ 1 1/4 inch Male NPT P A 0 temperature (Box 4,
“M” Sensor 17. Output No. 1 Code Code H).
Number of flow 1 20. Identification TagCode
element assemblies 2 ¤ Flange 3 (select Q Configurations Only 8. Tag can have 5 lines with
3 Codes for 7 and 8 MT86 18 characters per line.
Carbon steel; G Adhesive label A
4 from Tables A and B) 4-20 mA A
5 NEMA Type 4 ¤ Label and8 stainless B 9. Available with “S” Sensor
6 Medium Pressure ¤ 4-20 mA isolated E steel tag Type only due to gas type.
7 Packing Gland with ¤ Aluminum; L 10.Customer specified
8 Graphite Material hazardous locations ¤ 0-10 Vdc B ¤ Customer specified W calibration cannot exceed
500 psig [35 bar(g)] Groups B, C, D, E, F the maximum operating
and G MT91
maximum temperature and pressure
3. Sensor Points Code Field configurable, 1 21. Calibration of the MT Series
¤ 1 1/4 inch Male NPT R A 0 “S” Sensor dual analog outputs Code 1: Code configuration.
Number of sensing 1 Configurations Only Application
¤ Other 11. If Code D is selected in
points per flow 2 ¤ Flange 3 (select T *
Air; standard range, T Table A, Code S must be
element assembly 3 Codes for 7 and 8 Aluminum; D selected in Table B.
4 from Tables A and B) NEMA Type 4X and 18. Output No. 2 Code wind tunnel, flat
5 hazardous locations profile
6 Groups B, C, D, E, F
7
“M” or “S” Sensor
and G, EEx d IIC MT86 ¤ Air equivalency C
Configurations (Flue gas, waste gas
8 (meets IP66) None 0 etc.)
¤ Flange 3 (select F
¤ 300 Series stainless J ¤ 4-20 mA A
4. Process Codes for 7 and 8 ¤ Nitrogen, helium, E
Temperature Code from Tables A and B) steel; NEMA Type 4X ¤ 4-20 mA isolated E argon, carbon dioxide,
and hazardous or nitrous oxide 9
Range locations Groups B, ¤ 0-10 Vdc B
¤ Customer supplied F S W
C, D, E, F and G, ¤ Hydrocarbons F
-40° to 350° F S 4
flange ¤ DPDT relay with C (natural gas,
EEx d IIC (meets IP66) 2 amp contacts
[-40° to 177° C] methane, ethane,
¤ Flow element with propane, etc.) 9
¤ -40° to 850° F 9.- 12. Insertion Length ¤ Other * D
H fault alarm ¤ Hydrogen or G
[-40° to 454° C] hydrogen mixture 9
MT91
¤ Other * • Field configurable 2 ¤ Customer specified 10 W
with dual alarms
9 10 11 12
5. Material of ¤ Other * 22. Calibration
Construction Code See Installation drawings
to specify dimension in Code 2: Code
Setup
316 Stainless steel, A inc hes to the nearest 15. Remote
nickel braze per tenth of an inc h. Div ide Enclosure Code
millimeters by 25.4 to None 0
AMS 4777
conv ert to inches. No enclosure; P ¤ Temperature A
“M“ Sensor panel mounted compensation
Confguration Only circuit board
Table A Table B ¤ Vortab flow C
¤ 316 Stainless steel, E Carbon steel; G conditioner
nickel braze with 7. Flange Size Code NEMA Type 4
all wetted parts
8. Flange Material
and Rating Code
¤ Temperature F
nickel coated 2 1 1/2 inch9 B ¤ Aluminum; M compensation and
Vortab flow
150 lb. per G hazardous locations
¤ 316 Stainless steel, F 2 inch 9 2 material in Box 5 Groups D, E, F and G
conditioner
nickel braze with
150 lb. Carbon steel A
all wetted parts
Chromium Carbide
3 inch 3 ¤ DIN/EIN rack
5
R
300 lb. per H assemby
coated 2 4 inch 4 material in Box 5
“S“ Sensor Flat duct flange 11 D 300 lb. Carbon steel B ¤ Other *
Confguration Only
300 Series stainless S
¤ Hastelloy C C Customer specified 4 W steel (duct flange) 11