COUPLINGS
AND ADAPTORS
Main functions
Flange adaptors
These are junction products between a flanged item and a spigot end pipe or tube.
They are designed to connect with pipes or tubes of various materials.
They can also be dedicated for a particular pipe material and in this case are offered in standard or
anchored version. The anchored version removes the requirement of concrete anchor blocks.
Couplings
These are junction products between two spigot ends.
They are designed to be connected with pipes of various materials or dedicated to one particular material.
Repair collars
These are products which allow the fast and efficient repair of damaged pipes.
(holes, cracks, breakage)
With an adjustable length of wide stroke, they are products designed to simplify the installation and
dismantling of a flanged item in a network. Due to their design, they allow the anchoring of the junction
and remove the need of concrete anchor blocks.
C0.0/1
Edition 09-2007
Edition 09-2007
C0.0/2
ROBINETS-VANNES
COUPLINGS AND ADAPTORS
EURO 20
Range
Similar to the previous model, this coupling is suitable for PVC and PE. For connection of PE tubes it is
C0.0/3
Edition 09-2007
Edition 09-2007
This dismantling joint has lower dimensions than the previous model.
The fixed adjustment is obtained by removing a space ring.
These dismantling joints are available for :
DN 40 to DN 600 PFA 10 and 16 bar.
C0.0/4
C0.0/5
Edition 09-2007
The couplings, adaptors and sleeves from SAINT-GOBAIN CANALISATION are mainly intended for the potable water conveyance
market.
All of their components in contact with the potable water are in accordance with the European regulations and standards (KTW, WRC,
DGS approvals).
Dimensions in mm / weight in kg
Application range DE
Type
A
B
C
D
E
F
FP
G
H
I
J
JR
K
L
Flange DN(1)
mini
maxi
49
62
80
97
123
151
170
196
211
235
260
285
306
318
71
84
102
127
153
181
200
226
241
265
290
315
336
348
L1
L
J(2)
a
Weight
mini-maxi
50,60
50/60/65/80
65/80
100
125 et 150
150
200
200
200
250
250
300
300
300
142
142
142
142
142
142
142
142
172
172
172
173
173
173
82 - 106
82 - 106
83 - 107
84 - 115
87 - 118
87 - 119
88 - 120
95 - 127
105 - 138
97 - 130
113 - 147
101 - 135
106 - 141
117 - 152
mini-maxi
17
17
18
17
17
17
18
18
18
20
20
22
22
22
178
196
209
242
280
297
337
348
363
402
409
459
459
469
Performances :
4 - 32
4 - 32
5 - 31
7 - 30
8 - 29
9 - 27
10 - 26
12 - 35
13 - 34
14 - 33
15 - 36
16 - 35
18 - 40
18 - 48
(2)
4,1
4,7
5,0
6,3
8,7
9,3
11,1
11,4
12,1
16,5
16,1
21,1
20,5
20,6
J is given as follows :
Cover the whole range of external diameters from 49 to 348mm, without discontinuity.
Possible angular deflection of 6.
Table of use according to material of the pipe or tube : see page C1.1/2
Construction :
Body and gland : ductile iron with inside and outside epoxy coating of minimum thickness 250m.
Tie bars and nuts : zinc coated steel
Gasket : EPDM.
Connection with all flanged parts with standardized flanges in accordance with :
ISO 7005-2, ISO 2531, EN 1092-2.
Installation with an EPDM tab gasket.
Tightening torque on tie bars : 60 to 70 N.m
Not to be connected with a wafer type butterfly valve.
C1.1/1
Edition 09-2007
Installation :
Type
Edition 09-2007
OD mini
Pipes with
lead seal
Express
pipes
OD maxi
DN
OD
DN
OD
56
66
40
50
57
67
Rapid
pipes
DN
OD
Ductile
iron
Steel
PVC
Asbestos cement
DN
OD
OD
OD
DN / Classe
OD
40
50
56
66
51 - 54 - 57
60,3 - 63,5 - 70
50
63
40 Cl25
50 Cl10
60
66
50
60
66
77
63,5 - 70 - 76,1
82,5
63
75
50 Cl10, Cl25
60 Cl10-15, Cl25
66, 74
76, 80
49
71
40
50
62
84
50
60
66
77
50
60
67
77
80
102
80
98
80
98
80
98
88,9 - 101,6
90
60 Cl30
80 Cl10-15, Cl25
84
96, 100
97
127
100
118
100
118
80 102,2
100
100 123
118
101,6 - 108
114,3 - 127
110
125
80 Cl25, Cl 30
100 Cl10-15, Cl20-25
100, 104
118, 124
123
153
125
144
125
144
125
149
125
144
133 - 139,7
141,3 - 152,4
125
140
100 Cl30
125 Cl10-15, Cl20-25
130
145, 149
151
181
150
170
150
170
150
175
150
170
159 - 168,3
177,8
160
125 Cl30
150 Cl10, Cl15, Cl20
161
170, 174, 178
FP
170
200
175
196
175
196
177,8 - 193,7
200
174, 178
184, 192
196
226
200
222
200
222
175
201
200
222
219,1
200
225
211
241
200
222
200
222
200
227
200
222
219,1
225
244,5
250
175 Cl30
200 Cl10, Cl15, Cl20-25
200 Cl20-25, Cl30
225
220, 228, 238
238, 246
250
274
250
274
250
279
250
274
273
250 Cl15
280
235
265
260
290
60
81,4
JR
285
315
306
336
300
326
300
326
300
331
300
326
323,9
318
348
300
326
300
326
300
331
300
326
323,9
C1.1/2
315
292, 306
315
324, 334
324, 334
Dimensions in mm / weight in kg
Flange
DN
External diameter DE
of ductile iron pipe
Overall length
Weight QUICK GS
simple type
Weight QUICK GS
anchored type
mm
mm
mm
kg
kg
60 65*
80
100
125
150
200**
250**
300**
77
98
118
144
170
222
274
326
51
56
63
70
76
90
108
117
1.80
2.25
2.65
3.65
4.60
7.15
10.90
13.80
1.85
2.30
2.70
3.70
4.70
7.25
-
Construction :
Gland : ductile iron with inside and outside epoxy coating of minimum thickness 250m.
Gasket : EPDM.
Utilization with ductile iron pipes in accordance with EN 545 and ISO 2531.
Utilization of the simple (non-anchored) type possible with grey iron pipes with external diameters
in conformance with the above stated values.
Connection with all flanged parts with standardized flanges in accordance with : ISO 7005-2, ISO 2531,
EN 1092-2.
Tightening torque on bolts : M16 = 7.5m.daN, M20 = 10m.daN, M24 = 15m.daN.
Diagrams, drawings and propositions of assembly are not contractual
C1.2/1
Edition 09-2007
Installation :
Dimensions in mm / weight in kg
Adapter PFA 10 bar
ND
A
350 378 505
400 429 565
450 480 615
500 532 670
600 635 780
700 738 895
800 842 1015
900 945 1115
1000 1048 1230
L1
148
148
153
153
153
153
153
169
169
108
108
113
113
113
113
113
134
134
18
18
23
23
23
23
23
25
25
* J is given as follows :
Weight
24,2 520
27,9 580
35,7 640
40,3 715
49
840
56
910
68 1025
105 1125
121 1255
L1
148
148
153
153
153
153
153
169
169
108
108
113
113
113
113
113
134
134
18
18
23
23
23
23
23
25
25
Angular
deviation a
mini maxi en degrees
J*
ED
Weight
25,4 469 8
29,5 520 8
39,6 572 10
48
624 10
61,7 727 10
62,6 830 12
74,5 932 12
107 1054 14
128 1156 14
x
x
x
x
x
x
x
x
x
M12
M12
M12
M12
M12
M12
M12
M16
M16
12
12
12
12
12
12
12
16
16
25
25
25
25
25
25
25
40
40
1,5
1,5
1,5
1,25
1,25
1
0,75
0,75
0,75
Construction :
Body and gland : steel with inside and outside Rilsan coating of minimum thickness 250m.
Tie bars and nuts : zinc coated steel with rilsan coating of thickness 80m.
Gasket : EPDM.
Installation:
Edition 09-2007
Connection with all flanged parts with standardized flanges in accordance with :
ISO 7005-2, ISO 2531, EN 1092-2.
Full flange for standard flat gasket or metal reinforced gasket.
Tightening torque on bolts : M12 = 55 to 65 N.m, M16 = 95 to 110 N.m
C1.2/2
Dimensions in mm / weight in kg
Flange
DN
40
40 and 50*
50
60 and 65*
60 and 65*
80
100
125
125
150
200**
200**
mm
PVC tube
external diameter
according to ISO 161-1
or NF T 54.016
mm
40
50
63
63
75
90
110
125
140
160
200
225
Overall length
(L)
Weight
QUICK PVC
simple type
Weight
QUICK PVC
anchored type
mm
kg
kg
50
52
54
54
58
62
68
73
76
82
91
93
1.2
1.5
1.8
2.0
2.3
2.6
3.2
4.1
4.1
5.4
7.9
7.3
1.3
1.6
1.9
2.1
2.4
2.8
3.4
4.3
4.3
5.7
8.2
7.7
Other utilization :
Utilization of the QUICK PVC anchored type possible with PE tubes of external diameter DE 40 to DE 110mm.
Gland : ductile iron with inside and outside epoxy coating of minimum thickness 250m.
Gasket : EPDM.
Anchorage ring : brass.
Installation :
Connection with all flanged parts with standardized flanges in accordance with :
ISO 7005-2, ISO 2531, EN 1092-2.
Diagrams, drawings and propositions of assembly are not contractual
C1.3/1
Edition 09-2007
Construction :
Dimensions in mm / weight in kg
L
L1
Weight
kg
63
157
59
165
22
3.4
100 x 110
141
78
220
23
5.9
DN / DE PE
50 x
80 x
90
100 x 125
150 x 160
150 x 180
200* x 225
141
147
70
84
170
102
192
120
176
108
200
220
285
285
340
23
23
26
26
29
4.9
6.2
11.8
13.1
20.8
Construction :
Spigot and rotatable flange : ductile iron with inside and outside epoxy coating of minimum thickness 250m.
Spigot covered with PE 80.
Installation :
C1.4/1
Edition 09-2007
Connection of all flanged parts with standardized flanges (ISO 7005-2, ISO 2531,
EN 1092-2) with PE 80 or PE 100 tubes, PN 10, PN 12.5, PN 16.
Welding of the flange spigot on to the PE tube with an electrofusion coupling.
Usual tightening torque on flange bolts.
Installation with standard flat gasket or metal reinforced gasket.
Dimensions in mm / weight in kg
Application range DE
A
B
C
D
E
F
FP
G
H
I
J
JR
K
L
L1
L
Type
mini
maxi
49
62
80
97
123
151
170
196
211
235
260
285
306
318
71
84
102
127
153
181
200
226
241
265
290
315
336
348
J*
D
mini-maxi
182
182
182
232
232
232
262
262
262
262
292
292
292
292
104 - 152
104 - 152
107 - 155
127 - 188
135 - 197
144 - 207
150 - 214
159 - 224
163 - 228
171 - 237
179 - 246
187 - 255
194 - 263
198 - 267
Weight
mini-maxi
176
190
208
240
267
295
315
342
357
381
407
434
455
467
4 - 20
4 - 20
5 - 20
7 - 25
8 - 25
9 - 29
10 - 32
12 - 35
13 - 38
14 - 45
15 - 48
16 - 55
18 - 58
18 - 62
3,9
4,5
5,4
7,6
9,8
11,6
12,3
14,3
15,0
17,5
19,1
21,3
27,0
26,6
Performances :
Cover the whole range of external diameters from 49 to 348mm, without discontinuity.
Possible angular deflection of 2 x 6 = 12 between the two pipes.
Table of use according to material of the pipe or tube : see page C2.1/2
Body and glands : ductile iron with inside and outside epoxy coating of minimum thickness 250m.
Tie bars and nuts : zinc coated steel
Gaskets : EPDM.
Installation :
Connection of the spigots of two pipes of different materials or with different diameters.
Tightening torque on tie bars : 60 to 70 N.m
Diagrams, drawings and propositions of assembly are not contractual
C2.1/1
Edition 09-2007
Construction :
Type
Edition 09-2007
OD mini
Pipes with
lead seal
Express
pipes
OD maxi
DN
OD
DN
OD
56
66
40
50
57
67
Rapid
pipes
DN
OD
Ductile
iron
Steel
PVC
Asbestos cement
DN
OD
OD
OD
DN / Classe
OD
40
50
56
66
51 - 54 - 57
60,3 - 63,5 - 70
50
63
40 Cl25
50 Cl10
60
66
50
60
66
77
63,5 - 70 - 76,1
82,5
63
75
50 Cl10, Cl25
60 Cl10-15, Cl25
66, 74
76, 80
49
71
40
50
62
84
50
60
66
77
50
60
67
77
80
102
80
98
80
98
80
98
88,9 - 101,6
90
60 Cl30
80 Cl10-15, Cl25
84
96, 100
97
127
100
118
100
118
80 102,2
100
100 123
118
101,6 - 108
114,3 - 127
110
125
80 Cl25, Cl 30
100 Cl10-15, Cl20-25
100, 104
118, 124
123
153
125
144
125
144
125
149
125
144
133 - 139,7
141,3 - 152,4
125
140
100 Cl30
125 Cl10-15, Cl20-25
130
145, 149
151
181
150
170
150
170
150
175
150
170
159 - 168,3
177,8
160
125 Cl30
150 Cl10, Cl15, Cl20
161
170, 174, 178
FP
170
200
175
196
175
196
177,8 - 193,7
200
174, 178
184, 192
196
226
200
222
200
222
175
201
200
222
219,1
200
225
211
241
200
222
200
222
200
227
200
222
219,1
225
244,5
250
175 Cl30
200 Cl10, Cl15, Cl20-25
200 Cl20-25, Cl30
225
220, 228, 238
238, 246
250
274
250
274
250
279
250
274
273
250 Cl15
280
235
265
260
290
60
81,4
JR
285
315
306
336
300
326
300
326
300
331
300
326
323,9
318
348
300
326
300
326
300
331
300
326
323,9
C2.1/2
315
292, 306
315
324, 334
324, 334
DE
Lu
Dimensions in mm / weight in kg
Application range
DN
40
50
60
80
100
125
150
200
250
300
350
400
450
500
600
Min. DE
Max. DE
mm
mm
DE : external diameter
Construction :
55
65
76
97
117
143
168
220
272
323
375
426
477
529
631
58
68
79
100
120
146
172
223
275
327
379
430
481
533
636
approx. L
LU
Weight
mm
mm
mm
kg
126
127
127
127
133
140
145
153
164
170
183
185
192
193
200
60
60
60
60
65
70
75
80
90
95
100
100
105
105
110
168
178
191
213
233
259
287
342
403
457
511
564
617
671
777
3.1
3.1
4
4.8
6.6
7.6
9.6
14
18.1
22.2
28.3
33.4
37.9
45.6
58.6
Ring and glands : ductile iron with inside and outside epoxy coating of minimum thickness 250m.
Gaskets : EPDM.
Bolts : ductile iron with zinc based coating for DN 40 to 400,
steel with zinc based coating for DN 450 to 600.
Tightening torque on bolts : DN 40 to 20 : 8m.daN,
DN 250 to 600 : 12m.daN.
Angular deflection : DN 40 to 150 : 5
DN 200 to 300 : 4
DN 350 to 600 : 3
Diagrams, drawings and propositions of assembly are not contractual
C2.2/1
Edition 09-2007
Installation :
Dimensions in mm / weight in kg
ND
350
400
450
500
600
700
800
900
1000
DE
378
429
480
532
635
738
842
945
1048
* J is given as follows :
A
469
520
571,5
624
726,5
830
931,5
1054
1156
L
243
243
243
243
243
243
243
276
276
J*
E
L1
184
184
184
184
184
184
184
222
222
8
8
10
10
10
12
12
14
14
x
x
x
x
x
x
x
x
x
Weight
M12
M12
M12
M12
M12
M12
M12
M16
M16
21,2
23,7
26,2
29,2
34,2
39,6
45
88,3
96,8
mini
maxi
25
25
25
25
25
25
25
38
38
50
50
50
50
50
50
50
76
76
Angular
deviation a
en degrees
1,5
1,5
1,5
1,25
1,25
1
0,75
0,75
0,75
Construction :
Body and glands : steel with inside and outside Rilsan coating of minimum thickness 250m.
Tie bars and nuts : zinc coated steel
Gaskets : EPDM.
Installation :
Edition 09-2007
C2.2/2
Dimensions in mm / weight in kg
DE
DN
60
80
100
125
150
200
250
300
A
Min.
Max.
75.8
95.3
115.2
141.2
167.1
219
270.3
322.4
78
99
120
146
171.5
224.2
275.7
329.6
DE : external diameter
D
Max.
98
98
98
113
115
142
142
142
40
40
40
50
50
67
67
67
25
25
25
35
35
35
35
35
100
120
140
170
195
255
305
360
d screw
Tightening
torque
CHC
Nm
M10
M10
M10
M12
M12
M16
M16
M16
30
30
40
50
60
150
150
150
H
120
140
160
200
225
285
335
390
Weight
1.5
1.7
1.8
3.3
3.7
6
6.1
6.9
Construction :
Installation :
C2.3/1
Edition 09-2007
Dimensions in mm / weight in kg
DE
DN
40
50
63
75
90
110
125
140
160
180
200
225
A
Min.
Max.
39.5
49.5
62.5
74.5
89
109
124
139
159
178.5
198.5
223
40.5
50.5
63.5
75.5
91
111
126
141
161.5
182.5
202
227
DE : external diameter
D
Max.
62
62
77
98
98
98
115
115
115
142
142
142
14
14
29
40
40
40
50
50
50
67
67
67
8
8
17
25
25
25
35
35
35
35
35
35
60
70
85
95
110
130
165
180
200
210
230
255
d screw
Tightening
torque
CHC
N.m
M8
M8
M8
M10
M10
M10
M12
M12
M12
M12
M12
M12
15
15
20
30
30
40
40
50
60
60
60
80
H
80
90
105
115
130
150
185
200
220
240
260
285
Weight
0.6
0.6
0.8
1.5
1.7
1.8
3
3.3
3.5
6.2
6.6
7.2
Construction :
C2.4/1
Edition 09-2007
Installation :
Lenght
PE 80 PN 10
SDR 13.6 (S-6.3)
PE 80 PN 16
SDR 9 (S-4)
34.0
42.6
53.6
64.0
76.8
93.8
106.6
119.4
136.4
153.4
170.6
191.8
31.0
38.8
48.8
58.2
69.5
85.4
97.0
108.6
124.2
139.8
155.2
174.6
PE 100 PN 10
SDR 17 (S-8)
35.2
44.0
55.4
66.0
79.5
96.8
110.2
123.4
141.0
158.6
176.2
198.2
PE 100 PN 16
SDR 11 (S-5)
32.6
40.8
51.4
61.4
73.6
90.0
102.2
114.6
130.8
147.2
163.6
184.6
Weight
mm
55
55
55
65
65
65
75
75
75
100
100
100
0.1
0.1
0.2
0.2
0.2
0.3
0.3
0.4
0.4
0.6
0.7
0.8
Installation :
Edition 09-2007
Each PE spigot to be connected with a FixLINK coupling must be fitted with a reinforcement ring.
C2.4/2
Simple clamp
repair collar
Application
Range
DE
PFA
L = 200 mm
L = 300 mm
Application
Range
DE
PFA
L = 200 mm
L = 300 mm
L = 500 mm
Min.
bar
type
type
weight
Min.
Max.
bar
type
weight
type
weight
type
weight
C1-78
C1-88
C1-98
C1-108
C1-114
C1-126
C1-138
C1-140
C1-150
C1-162
C1-168
C1-174
C1-186
C1-198
C1-210
C1-222
C1-234
C1-243
C1-260
C1-273
C1-285
C1-298
5.9
6.1
6.2
6.3
6.4
6.5
6.7
6.7
6.8
6.9
7.0
7.0
7.3
7.4
7.5
7.7
7.8
7.9
8.0
8.3
8.4
8.6
88
114
138
160
182
202
217
240
262
273
296
324
346
365
387
410
428
450
470
492
110
137
160
182
202
224
240
262
284
296
319
346
368
387
410
432
450
474
492
516
26
22.5
20
17
15.5
13.5
12.5
10.5
9.5
9
8
6.5
6
5.5
4.5
4
3.5
3
2.5
2.5
D2-88
D2-114
D2-138
D2-160
D2-182
D2-202
D2-217
7.2
7.4
7.6
7.7
8.0
8.1
8.2
E2-114
E2-138
E2-160
E2-182
E2-202
E2-217
E2-240
E2-262
E2-273
E2-296
E2-324
E2-346
E2-365
E2-387
E2-410
E2-428
E2-450
E2-470
E2-492
11.5
11.7
11.8
12.2
12.3
12.4
12.8
12.9
13.4
13.3
13.6
13.8
14.0
14.3
14.6
14.8
15.6
15.7
15.8
F2-182
F2-202
F2-217
F2-240
F2-262
F2-273
F2-296
F2-324
F2-346
F2-365
F2-387
F2-410
F2-428
F2-450
F2-470
F2-492
20.8
21.0
21.2
21.7
22.3
22.6
23.0
23.8
23.8
24.3
25.6
26.1
25.8
27.0
27.3
27.8
48
56
60
68
78
88
98
108
114
126
138
140
150
162
168
174
186
198
210
222
234
243
260
273
285
298
Max.
56
64
68
78
88
98
108
118
126
138
150
153
162
174
182
186
198
210
223
234
246
255
272
285
297
310
32
31
30
29
28
26
25
23
22.5
21.5
20
20
19
17
16.5
16
15
13.5
13
12
11
10.5
9.5
9
8.5
8
B1-48
B1-56
B1-60
B1-68
B1-78
B1-88
B1-98
B1-108
B1-114
B1-126
B1-138
B1-140
B1-150
B1-162
B1-168
B1-174
B1-186
B1-198
B1-210
B1-222
B1-234
B1-243
B1-260
B1-273
B1-285
B1-298
DE : external diameter
weight
3.6
3.7
3.8
3.8
3.9
4.0
4.1
4.1
4.2
4.3
4.4
4.4
4.4
4.5
4.6
4.7
4.8
4.9
5.0
5.0
5.1
5.2
5.3
5.4
5.5
5.6
C3.1/1
Edition 09-2007
Construction :
Installation :
Repair of porosities and cracks : the collar length must be at least equal to three times the length of the defect.
HELP FOR THE CHOICE OF THE TYPE OF COLLAR DEPENDING ON THE PIPE TO REPAIR :
Iron
Grey
DN
Lead seal
40
50
60
80
100
125
150
175
200
250
300
350
400
450
DE
56
66
77
98
118
144
170
196
222
274
326
378
429
480
B1-48 / B1-56
B1-60 / B1-68
B1-68 / B1-78
B1-88 / B1-98
B1-114
B1-138
B1-162
B1-186 / B1-198
B1-210 / B1-222
B1-260 / B1-273
E2-324
E2-365
E2-410
E2-470
DE : external diameter
Remarques :
Type
Ductile
EXPRESS
DE
57
67
77
98
118
144
170
196
222
274
326
378
429
480
Type
B1-56
B1-60
B1-68
B1-98
B1-114
B1-138
B1-162
B1-186
B1-210
B1-273
E2-324
E2-365
E2-410
E2-470
RAPID
DE
81.4
102.2
123
149
175
201
227
279
331
Type
B1-78
B1-98
B1-114
B1-138
B1-168
B1-198
B1-222
B1-273
E2-324
PVC-U
Steel
EXPRESS-STANDARD
DE
56
66
77
98
118
144
170
196
222
274
326
378
429
480
Type
B1-48
B1-60
B1-68
B1-88
B1-114
B1-138
B1-162
B1-186
B1-210
B1-273
E2-324
E2-365
E2-410
E2-470
DE
50
63
75
90
110
125
140
160
200
225
250
315
400
500
Type
B1-48
B1-56
B1-68
B1-88
B1-108
B1-114
B1-138
B1-150
B1-198
B1-222
B1-243
E2-296
E2-387
E2-492
DE
48.3
54
57
60.3
70
73
76.1
88.9
108
114.3
133
139.7
141.3
159
168.3
177.8
193.7
219.1
244.5
273
323.9
355.6
406.4
Type
B1-48
B1-48
B1-56
B1-56
B1-68
B1-68
B1-68
B1-88
B1-98
B1-108
B1-126
B1-138
B1-138
B1-150
B1-162
B1-168
B1-186
B1-210
B1-234
B1-273
E2-324
E2-346
E2-387
Edition 09-2007
It is recommented to measure the external diameter of the pipe in order to confirm the choice of the collar.
This table mainly proposes to use the B1 model. The use of C1, D2, F2 models is possible on checking the
compatibility with the external diameter of the pipes.
G Fibre-cement pipes : measure systematically the external diameter of the pipe before choosing the collar.
G These collars are not used on PEHD pipes.
C3.1/2
Type W3
Max.
W2-A
W2-B
W2-C
W2-D
W2-F
W2-G
W2-I
W2-J
W2-L
W2-M
W2-P
W2-Q
W2-R
mm
mm
W3-H
W3-I
W3-J
54
60
76
89
95
108
116
133
142
159
168
193
214
216
267
315
61
68
87
98
108
118
128
144
153
172
184
203
225
250
298
358
Class
Lead
EXPRESS
seal EXPRESS RAPID STANDARD
40
50
60
80
40
50
60
80
DN
40
50
60
60
80
80
100
100
100
100
150
175
200
150
175
200
150
175
150
175
200
125
200
250
300
125
200
250
300
Fibre-cement
125
200
250
300
125
200
250
300
25
DE
63
75
90
60.3
76.1
110
125
140
139.7
200
225
219.1
160
225
250
315
114.3
60*
80*
168.3
219.1
273
318
323.9
mm
mm
30
DN
80*
125*
175*
175*
150*
175*
175*
200
200
240
200
200
240
240
245
245
300
300
400
400
250
350
400
PFA
Weight
178
184
192
218
218
245
245
258
258
300
300
360
360
bar
kg
420
10
365
460
16
6
5.9
8.3
8.6
8.4
11.6
11.2
13.8
13.7
21.3
22.3
39.9
37.5
25.5
46
59.6
Construction :
C3.2/1
Edition 09-2007
Min.
Steel
Ductile
Overall
diameter
PVC-U
Iron
Grey
DE
Type
Type of pipe
Application range
Length
Type W2
fl D
DN
PFA 10
DN
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1200
PFA 16
L
Weight
Voir PFA 16
280
280
280
280
280
280
330
330
260
290
290
290
320
340
395
445
505
565
615
670
780
895
1015
1115
1230
1455
Construction :
428
432
432
436
464
476
526
546
450
480
480
485
545
53
72
81
109
150
180
206
264
256
352
405
484
744
DN
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1200
200
200
200
200
200
200
200
280
280
280
280
280
280
330
330
300
320
320
340
360
150
165
185
200
220
250
285
340
405
460
520
580
640
715
840
910
1025
1125
1255
1485
PFA 25
L
316
316
316
320
320
324
344
428
432
456
460
480
493
556
580
500
530
540
570
630
Weight
12
13
15
21
22
28
37
60
84
99
143
170
187
276
395
366
482
546
715
1112
DN
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1200
200
200
200
200
200
240
240
280
280
280
320
320
320
380
380
340
360
380
400
450
150
165
185
200
235
270
300
360
425
485
555
620
670
730
845
960
1085
1185
1320
1530
330
330
330
330
330
380
380
430
440
440
500
500
500
530
600
560
620
635
680
760
Weight
11
14
18
22
29
42
51
73
101
132
200
243
295
344
462
571
801
886
1270
1871
Body and gland : steel with inside and outside epoxy coating of minimum thickness 250m.
Gasket : EPDM.
Tie bars and nuts : steel, zinc coated.
Connection with all flanged parts equipped with standardized flanges in accordance with :
ISO 7005-2 - ISO 2531 - EN 1092-2.
The flange of the sliding body has a stop and thus a standardized sealing surface at the gasket.
C4.1/1
Edition 09-2007
Installation :
PFA 10
DN
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
100
100
100
100
100
100
100
100
110
110
120
120
120
120
120
Construction :
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
150
165
185
200
220
250
285
340
395
445
505
565
615
670
780
DN
+0
-x
PFA 16
L
180
180
180
180
180
180
195
195
215
215
215
230
230
230
240
Weight
5,5
6
7,5
9
13
17
21
29
38
46
57
72
80
90
120
DN
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
100
100
100
100
100
100
100
100
120
120
120
130
130
150
150
8
8
8
8
8
10
10
10
10
10
10
10
10
10
12
150
165
185
200
220
250
285
340
405
460
520
580
640
715
840
180
180
180
180
180
180
195
195
225
225
250
250
250
285
300
Weight
5,5
6
7,5
9
13
17
21
29
44
55
77
98
122
156
222
Body and gland : steel with inside and outside epoxy coating of minimum thickness 250m.
Gasket : EPDM.
Tie bars and nuts : steel, zinc coated.
Installation :
C4.2/1
Edition 09-2007
Connection with all flanged parts equipped with standardized flanges in accordance with :
ISO 7005-2 - ISO 2531 - EN 1092-2.
The stroke X is obtained by taking off the metal ring at the gasket. In case of replacement of the valve, this
dismantling joint is reusable only if the face to face distance is the same or lower, restricted to the stroke X.
Conversely, if the new valve is shorter, this joint is not reusable, it is necessary to add a space ring or to use a
dismantling joint with wide stroke.