Goal: describe the entry data format to enable countries to add data in CAD Library
Scope: CAD Library
Reference / Version : 1.0
Document status
draft
Confidentiality
yes
Function
Project Manager
Project Manager
Author
Owner
Verified by
Approved by
validated
no
Name
BRANCHE A.
BRANCHE A.
GASPAR L.
GASPAR L.
Distribution
Function
Name
Audience
Function
Name
signature
Date
03/03/05
11/04/05
Document location :
1.0
Index
10/02/2005
Date
BRANCHE A. Creation
Author
Reasons for change
Changed sections
Table of content
1
INTRODUCTION...................................................................................................................................................3
BINARY FILES......................................................................................................................................................5
DES_CAD_Library_2005_Adaptation_EN.doc
Page 2/7
1 Introduction
CAD Library is a software that displays AutoCAD schemes (WMF format) of Schneider products using a
treeview. The software provides also an export functionality (formats DWG, DXF, DWF) and a direct link with
AutoCAD.
CAD Library data can be updated without modifying the software the aim of this document is to explain
how. Basically the main steps are:
Additionally some options can be configured in a .INI file called SE_CadLibrary2005.ini and through the
File -> Settings menu.
DES_CAD_Library_2005_Adaptation_EN.doc
Page 3/7
3.1
3.1.1
Header
INFO=chapter
DATE=
LANGUE=FR or EN
3.1.2
optional
not used
Data rows
File name<TAB>Hierarchy<TAB>Entry point
Each row is made of :
File name : name of the drawing with no extension. The associated files are available in wmf directory and
dwg.zip file.
Hierachy : path to go to the drawing from the chapter and the entry point. The separator is \.
Example:
DES_CAD_Library_2005_Adaptation_EN.doc
Page 4/7
XCT16M4F
:XCT16M4F
Entry point : each drawing can be accessed through different entry points. Entry point is optional. If no
entry point is specified, then the full path to go to the drawing will be :
1. Chapter
2. Hierarchy
Example:
XCT16M4F
3.1.3
ID_2
Entry points
[LIB]
Entry point<TAB> Entry point description
The entry point description is mandatory.
Example:
[LIB]
ID_2
Final power distribution devices and enclosures
3.1.4
Limitations
All these fields are subject to 2 limitations:
Total size of each line no more than 1024 characters
Windows full path no more than 255 characters
4 Data files
The drawings must be available as DWG and WMF files.
DWG files are moved to associated dwg.zip files (see chapter 2).
WMF files are moved to associated wmf directories (see chapter 2).
Check that the DWG versions of the files are compliant with the AutoCAD releases used by your customers
and if needed convert the files to the lowest format.
5 Binary files
Binary files generated by the software allow a quickest browse of the hierarchy. These files are generated at
the first launch of the application if they do not exist.
After you have prepared your data for adaptation, the following steps must be done:
Copy all data in the main directory
Delete all cadlibdata*.bin from the main directory
Launch CAD Library in English
Launch CAD Library in French
Now data is ready to be used on a CD.
DES_CAD_Library_2005_Adaptation_EN.doc
Page 5/7
GLOBAL section:
o Name of the first node of the hierarchy (1)
o Data and revision available on the splash screens (2)
DISPLAY section:
o Logo (3)
o Splash screens (4)
o Adaptation menu (visible / not visible) please note that the menu ill be visible only if the
option is set to 1 and the file is available in the main directory. (5)
Exemple:
[GLOBAL]
1
Application=CADlibrary2005
version=1.00r02a
Copyright=2005 Schneider Electric, AlpCAD Software SA and OptiTECH
Date=20050406
VERSION_FR=Version 1.00r02a (06/04/2005)
UPDATE_FR=Avril 2005
2
VERSION_EN=Version 1.00r02a (2005/04/06)
UPDATE_EN=April 2005
[PARAMETERS]
CurrentLanguage=
TreeRootInfo_EN=CAD Library 2005
TreeRootInfo_FR=CAD Library 2005
MainWindowTitle_EN=AutoCAD Library Schneider Electric
MainWindowTitle_FR=Bibliothque AutoCAD Schneider Electric
CreateSubdirectoryOnExport=1
CleanTree=0
[DISPLAY]
;SchneiderLogoBitmap=LogoSchneider.bmp
3
SchneiderLogoBitmap= LogoSchneider.bmp
SplashBitmapFR=SCADFR_loading.bmp
SplashBitmapEN=SCADFR_loading.bmp
4
AboutBitmapFR=SCADFR_version.bmp
AboutBitmapEN=SCADFR_version.bmp
XY_BitmapVersion=20,280
XY_BitmapUpdate=20,250
StartSplash=1
StartSplashDelay=300
TopFen=0
HelpMenuAdaptationOption=1
AdaptationPdfFile=DES_CAD_Library_2005_Adaptation_EN.pdf
HelpMenuTechnicalInfoOption=0
TechnicalPdfFile=CADlibrary2005_TechnicalInfo.pdf
DES_CAD_Library_2005_Adaptation_EN.doc
Page 6/7
7 Settings menu
The following options are available in the File -> Settings menu:
AutoCAD : useful to specify the location of AutoCAD software if the installation was not standard or
to precise which AutoCAD version to use on the PC
More :
o
o
o
o
o
o
o
DES_CAD_Library_2005_Adaptation_EN.doc
Page 7/7