Professional Documents
Culture Documents
Vertical Vapor Liquid Separator Sizing: Chemical Engineering Calculations
Vertical Vapor Liquid Separator Sizing: Chemical Engineering Calculations
CheCalc.com
INPUT
Vapor Flowrate
Vapor Density
Liquid Flowrate
Liquid Density
Liquid Holdup Time
Slug Capacity
L/D Maximum
100000.0 Kg/h
20.180 Kg/m
50000.0 Kg/h
736.10 Kg/m
5.0 min
0.57 m
4.0
Tag No.
Description
Date
By
V-101
Receiver
10/4/2014
CheCalc
Operating Pressure
K Value Criterion
K Value Calculated
User Input K Value
Diameter Calculated
User Input Diameter
10.0
Compressor Suction S
0.074
2400
2400 mm
3100 mm
h1
h2
h3
h4
h5
h6
h7
150 mm
1457 mm
150 mm
426 mm
406 mm
150 mm
360 mm
L/D
1.29
With
Mist Eliminator
h7
h6
h5
h4
h3
h2
h1
Mesh
2200 mm
Barg
or Suction Scrubber
m/s
m/s
mm
mm
Kg/m.s
mm
inch
mm
m/s
mm
inch
mm
Without
Mist Eliminator
h5
h4
h3
h2
h1
INPUT
Vapor Flowrate
Vapor Density
Liquid Flowrate
Liquid Density
Liquid Holdup Time
Slug Capacity
L/D Maximum
22046.2 lb/h
1.260 lb/ft
11023.1 lb/h
45.95 lb/ft
5.0 min
149.52 Gallon (US)
3.0
Tag No.
Description
Date
By
V-101
Receiver
10/4/2014
CheCalc
Operating Pressure
K Value Criterion
K Value Calculated
User Input K Value
Diameter Calculated
User Input Diameter
145.0
No Special Requireme
0.345
3.5
3.5 ft
10.0 ft
h1
h2
h3
h4
h5
h6
h7
6.0 inch
53.4 inch
12.0 inch
6.6 inch
24.0 inch
6.0 inch
12.0 inch
L/D
2.86
With
Mist Eliminator
h7
h6
h5
h4
h3
h2
h1
Mesh
2.5 ft
PSIG
l Requirement
ft/s
ft/s
ft
ft
lb/ft.s
inch
inch
inch
ft/s
inch
inch
inch
Without
Mist Eliminator
h5
h4
h3
h2