Column 75-Staad Output

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Thursday, June 30, 2016, 03:53 PM

STAAD SPACE

-- PAGE NO.

118

============================================================================
C O L U M N

N O.

M20
LENGTH:

75

D E S I G N

R E S U L T S

Fe500 (Main)
4300.0 mm

CROSS SECTION:

** GUIDING LOAD CASE:

13

Fe500 (Sec.)

230.0 mm X

SHORT(Z)

375.0 mm

COVER: 40.0 mm

/BRACED LONG(Y)

CASE 1: MINIMUM ECC. ABOUT Y CONSIDERED


DESIGN FORCES (KNS-MET)
----------------------DESIGN AXIAL FORCE (Pu)

148.71

INITIAL MOMENTS
MOMENTS DUE TO MINIMUM ECC.

:
:

About Z
60.43
0.00

About Y
9.86
2.97

SLENDERNESS RATIOS
MOMENTS DUE TO SLENDERNESS EFFECT
MOMENT REDUCTION FACTORS
ADDITION MOMENTS (Maz and May)

:
:
:
:

11.47
0.00
1.00
0.00

18.70
5.98
1.00
5.98

TOTAL DESIGN MOMENTS

60.43

24.64

REQD. STEEL AREA


:
1933.95 Sq.mm.
INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

C:\Users\Admin\Desktop\SID\Staad\Guest House.anl

Page 118 of 142

Thursday, June 30, 2016, 03:53 PM


STAAD SPACE

** GUIDING LOAD CASE:

-- PAGE NO.

119

13

CASE 2: MINIMUM ECC. ABOUT Z CONSIDERED


DESIGN FORCES (KNS-MET)
----------------------DESIGN AXIAL FORCE (Pu)

148.71

INITIAL MOMENTS
MOMENTS DUE TO MINIMUM ECC.

:
:

About Z
60.43
3.14

About Y
9.86
0.00

SLENDERNESS RATIOS
MOMENTS DUE TO SLENDERNESS EFFECT
MOMENT REDUCTION FACTORS
ADDITION MOMENTS (Maz and May)

:
:
:
:

11.47
0.00
1.00
0.00

18.70
5.98
1.00
5.98

TOTAL DESIGN MOMENTS

60.43

24.64

REQD. STEEL AREA


:
1933.95 Sq.mm.
INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)
CRITICAL CONDITION : MAXIMUM AREA OF STEEL REQUIRED OF THE 2 CASES.
REQD. STEEL AREA
:
1933.95 Sq.mm.
REQD. CONCRETE AREA:
84316.05 Sq.mm.
MAIN REINFORCEMENT : Provide
4 - 25 dia. (2.28%,
1963.50 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 230 mm c/c
SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)
---------------------------------------------------------Puz :
1484.08
Muz1 :
110.98
Muy1 :
54.37
INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)
SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)
---------------------------------------------------------WORST LOAD CASE:
13
Puz :
1494.89
Muz :
134.73
Muy :
62.49
IR: 0.87
============================================================================

C:\Users\Admin\Desktop\SID\Staad\Guest House.anl

Page 119 of 142