Professional Documents
Culture Documents
Jupiter 200: Description
Jupiter 200: Description
Jupiter 200: Description
Magnetostrictive
Level Transmitter
DESCRIPTION
The Jupiter 200 transmitter is a loop-powered, 24 V DC liquid-level transmitter and utilises the effect of a magnetic
eld on the magnetostrictive wire. Jupiter is available as a
direct insertion transmitter or as an external mounted transmitter onto the Atlas Magnetic Level Indicator. The unit can
be designed for liquid level and/or liquid-liquid interface
measurement.
The innovative enclosure is a rst in the industry, orienting
dual compartments (wiring and electronics) in the same
plane and angled to maximize ease of wiring, conguration,
set-up and data display.
The high safety level of the Jupiter is demonstrated by a
Safe Failure Fraction > 90%.
F E AT U R E S
NT
SA
EGRITY
V EL
LE
A P P L I C AT I O N S
MEDIA:
- Highly recommended for use in liquids with enhanced
foam development.
- Interface measurement where the upper liquid layer has a
higher dielectric than the lower liquid layer.
CONDITIONS:
- Suited for use in a turbulent liquid environment as the
oat remains in contact with the liquid surface whilst emitting its signal.
A G E N C Y A P P R O VA L S
Agency
ATEX
IEC
Approvals
II 1 G Ex ia IIC T4 Ga, intrinsically safe
II 1 G Ex ia IIC T4 Ga, FISCO intrinsically safe
II 1/2 G Ex d IIC T6 Ga/Gb, ameproof enclosure
Ex ia IIC T4 Ga, intrinsically safe
Ex ia IIC T4 Ga, FISCO intrinsically safe
Ex d IIC T6, ameproof enclosure
Lloyds Register of Shipping (marine applications)
LRS
FM/CSA
Russian Authorisation Standards
Other approvals are available, consult factory for more details
TECHNOLOGY
P A C T w a r e P C S O F T WA R E P R O G R A M
FDT technology provides an open communication interface between field instruments of various communication
protocols and the host/ DCS system. The DTM driver is
typical for one type of instrument and delivers the full functionality of the device added with graphical user interface
via a laptop or PC. Magnetrol transmitters use the free
shareware PACTware software to support DTM drivers
and the FDT functionality. Via PACTware it becomes
easy to configure, monitor and diagnose a Magnetrol
transmitter from distance or even to call for factory assistance over the internet via the supply of screenshots of
echo curves and trending graphs. Magnetrol DTM library
HART has passed the dtmINSPECTOR, the official FDT
interoperability test and certification tool. The Magnetrol
DTMs are free of charge and can be downloaded from
www.magnetrol.com or obtained via CD Rom from your
nearest Magnetrol contact.
PACTware CD with
DTM drivers
A P P L I C AT I O N S
As direct insertion model: Jupiter can be mounted inside a bridle, stillwell, external cage or directly inside the vessel.
As external mount model: Jupiter can be mounted on a new ordered magnetic level indicator.
Direct insertion
Externally mounted
on magnetic level
indicator
Externally mounted
on magnetic level
indicator measuring
2 liquid levels
F L O AT FA I L U R E I D E N T I F I C AT I O N
The Jupiter 200 with SIL enhanced electronics is either using a probe with inactive zone or an extended MLI cage to identify a sinking or collapsed oat as a oat failure. Jupiter 200 with SIL enhanced electronics are equipped with one oat for
measuring either the top level or the interface level.
Active span
4 - 20 mA
Active span
4 - 20 mA
Direct insertion
External mount
S E L E C T I O N D ATA
1. Jupiter 200: transmitter and probe (MLI or cages as shown in this bulletin are not included).
2. OPTION: ATLAS. Magnetic level indicator for use with Jupiter 200, external mount model. Consult bulletin BE 46-138.
3. Free of charge: Magnetrol master C.D. with Jupiter 200 DTM (PACTware). Order code: 090-BE59-200 (included in each
order).
4. OPTION: MACTek Viator USB HART interface: order code: 070-3004-002
330
(13.00)
330
(13.00)
214
(8.43)
126
(4.94)
Primary oat.
For total or interface
level.
Jupiter Housing,
(45 View)
Active
span
Probe
length
111
(4.38)
Active
span
Probe
length
One oat
for total or interface
level.
Secondary oat.
For total level and
interface level.
127 (5.00)
Inactive zone
16 (0.63)
105
(4.12)
102
(4.00)
330
(13.00)
Dead band
Single oat: 76 (3) ref.
Dual oats: 152 (6) ref.
Standard electronics
83
(3.28)
16 (0.63)
2 cable
entries
45
Jupiter Housing
2
2
2
2
2
4
5
6
7
8
Magnetostrictive
Magnetostrictive
Magnetostrictive
Magnetostrictive
Magnetostrictive
transmitter
transmitter
transmitter
transmitter
transmitter
with
with
with
with
with
for
for
for
for
for
total
total
total
total
total
level
level
level
level
level
or interface
or interface
or interface
and interface
and interface
APPROVAL
1
FM/CSA, intrinsically safe, non-incendive
FM/CSA, explosion proof
3
A
ATEX ameproof enclosure
E
ATEX intrinsically safe (digit 2 = 4, 6 or 7) / ATEX FISCO (digit 2 = 5 or 8)
J
IEC ameproof enclosure
K
IEC intrinsically safe (digit 2 = 4, 6 or 7) / ATEX FISCO (digit 2 = 5 or 8)
L
INMETRO ameproof enclosure
M INMETRO intrinsically safe (digit 2 = 4, 6 or 7) / ATEX FISCO (digit 2 = 5 or 8)
CONFIGURATION
D Direct insertion
MOUNTING CONNECTION
Refer to sizing chart for chambers and stilling wells on the next page.
Tri-Clamp
Threaded
1 1 3/4" NPT
4 1 2" NPT
2 2 1" BSP (G 1")
ANSI anges
2 3 1"
2 4 1"
2 5 1"
2 7 1"
3 3 1 1/2"
3 4 1 1/2"
3 5 1 1/2"
3 7 1 1/2"
4 3 2"
4 4 2"
4 5 2"
4 7 2"
150 lbs
300 lbs
600 lbs
900/1500 lbs
150 lbs
300 lbs
600 lbs
900/1500 lbs
150 lbs
300 lbs
600 lbs
900/1500 lbs
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
RF
RF
RF
RF
RF
RF
RF
RF
RF
RF
RF
RF
3
4
5
6
P
P
P
P
5
5
5
5
6
6
6
6
3
4
5
6
3
4
5
6
3"
3"
3"
3"
4"
4"
4"
4"
E
E
F
F
A
B
A
B
DN80
DN80
DN100
DN100
EN (DIN) anges
150
300
600
900
150
300
600
900
lbs
lbs
lbs
lbs
lbs
lbs
lbs
lbs
PN16
PN25/40
PN16
PN25/40
EN
EN
EN
EN
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
ANSI
1092-1 Type A
1092-1 Type A
1092-1 Type A
1092-1 Type A
2
6
RF
RF
RF
RF
RF
RF
RF
RF
MATERIAL OF CONSTRUCTION
Max Process Temp: +95 C (+200 F)
A
B
C
D
responding Ra value.
A
B
UNIT OF MEASUREMENT
Insertion length in cm
0 3 0
5 7 0
min 30 cm (12")
max 570 cm (224")
57 (2.25)
64 (2.5)
76 (3.0)
3"
sch. 5/10
3"
sch. 40
4"
sch. 5/10
4"
sch. 40
4"
sch. 80
4"
sch. 160
Probe lengths
> 366 cm (144")
4"
sch. 10
4"
sch. 40
316/316L SST
0,86
0,83
0,7
0,68
0,64
0,52
< 0,52
Titanium
Hastelloy C
AA
51 mm (2.0")
AA
51 mm (2.0")
AB
58 mm (2.3")
AB
58 mm (2.3")
AC
64 mm (2.5")
99
consult factory
99
consult factory
BA
51 mm (2.0")
BA
51 mm (2.0")
BA
51 mm (2.0")
BB
57 mm (2.25")
BB
57 mm (2.25")
BB
57 mm (2.25")
99
consult factory
CA
47 mm (1.85")
CB
57 mm (2.25")
CB
57 mm (2.25")
99
consult factory
99
consult factory
99
consult factory
99
consult factory
316/316L SST
Titanium
Hastelloy C
MA
51 mm (2.0")
MB
51 mm (2.0")
NA
51 mm (2.0")
NB
51 mm (2.0")
PA
47 mm (1.85")
PB
47 mm (1.85")
20 ( 70)
40 (100)
150 (300)
21,7 (315)
260 (500)
22,3 (323)
230 (450)
21,2 (308)
12
AB
MA
13
AC
22
AB
MB
BA
NA
21
23
8
Total Interface
AA
31
AA
AC
CB
25,3 (367)
23,2 (337)
200 (400)
Hygienic service
316/316L SST
0,4 m Ra (15 Ra)
RA
51 mm (2.0")
QB
51 mm (2.0")
Dim "B"
height
24,3 (352)
175 (350)
CA, PA,
PB
Hygienic service
316/316L SST
0,5 m Ra (20 Ra)
QA
51 mm (2.0")
Code
32
41
42
51
52
61
62
PB
RB
51 mm (2.0")
Dim "A"
26,3 (381)
120 (250)
BB
Hygienic service
316/316L SST
0,4 m Ra (15 Ra)
FA
51 mm (2.0")
FA
51 mm (2.0")
FB
58 mm (2.3")
FB
58 mm (2.3")
FC
64 mm (2.5")
99
consult factory
99
consult factory
PHYSICAL DIMENSIONS
30,3 (440)
27,8 (403)
95 (200)
BA, NA,
NB
Hygienic service
316/316L SST
0,5 m Ra (20 Ra)
DA
51 mm (2.0")
DA
51 mm (2.0")
DB
58 mm (2.3")
DB
58 mm (2.3")
DC
64 mm (2.5")
99
consult factory
99
consult factory
Float
Code
Dim "C"
magnet location
(Submergence depth)
PB
Probe Length =
active span + 20 cm
Active
Span
External mount
Top mount
Probe Length =
active span + 15 cm
Active
Span
External mount
Top mount with offset
Probe Length =
active span + 15 cm
Active
Span
Probe Length =
active span + 38 cm
Active
Span
External mount
Top mount - high temp.
Probe Length =
active span + 38 cm
Active
Span
External mount
Bottom mount with offset
External mount
Bottom mount - high temp.
FLOAT
DIMENSIONS in mm (inches)
203
(8.00)
292
(11.50)
279
(11.00)
203
(8.00)
Probe Length =
active span + 20 cm
Active
Span
Probe Length =
active span + 15 cm
Top mount
318
(12.50)
Active
Span
Probe Length =
active span + 15 cm
Active
Span
Probe Length =
active span + 38 cm
Active
Span
292
(11.50)
203
(8.00)
Active
Span
279
(11.00)
Probe Length =
active span + 38 cm
318
(12.50)
Note: When specifying the mounting location, be aware of other accessories that may also mount on the magnetic level
indicator (i.e. switches, heat tracing, etc). Choose left side mount whenever possible.
Add additional 5 cm for SIL enhanced electronics
10
2
2
2
2
2
4
5
6
7
8
Magnetostrictive
Magnetostrictive
Magnetostrictive
Magnetostrictive
Magnetostrictive
transmitter
transmitter
transmitter
transmitter
transmitter
with
with
with
with
with
for
for
for
for
for
Total level and interface measurement requires 2 oats, consult factory for magnetic level indicator (MLI)
total
total
total
total
total
level
level
level
level
level
or interface
or interface
or interface
and interface
and interface
APPROVAL
1
FM/CSA, intrinsically safe, non-incendive
3
FM/CSA, explosion proof
ATEX ameproof enclosure
A
E
ATEX intrinsically safe (digit 2 = 4, 6 or 7) / ATEX FISCO (digit 2 = 5 or 8)
J
IEC ameproof enclosure
K
IEC intrinsically safe (digit 2 = 4, 6 or 7) / ATEX FISCO (digit 2 = 5 or 8)
L
INMETRO ameproof enclosure
M INMETRO intrinsically safe (digit 2 = 4, 6 or 7) / ATEX FISCO (digit 2 = 5 or 8)
CONFIGURATION
E
Top mount, probe material code 1 only
F
Top mount offset, probe material code 1 only
G Top mount offset, high temperature, probe material code A only
H Bottom mount offset, probe material code 1 only
J
Bottom mount offset, high temperature, probe material code A only
MOUNTING LOCATION
0 0
0 1
1
A
0 0
0 0
1
2
3
4
5
0
E
F
G
H
J
0
0 3 0
5 7 0
2
0 0
min 30 cm (12")
max 570 cm (224")
T R A N S M I T T E R S P E C I F I C AT I O N S
FUNCTIONAL/PHYSICAL
Description
HART
Foundation
Fieldbus
Resolution
Diagnostic Alarm
User Interface
Standard
electronics
Enhanced
electronics
Equivalent Data
Environmental protection
Net weight
Foundation Fieldbus
specications
Analog: 0,01 mA
Display: 0,1 units
620 @ 20,5 mA - 24 V DC
Adjustable 0-25 s
Approvals
Surging protection
ameproof enclosure: 12 to 32 V DC
intrinsically safe: 12 to 28,4 V DC
ameproof enclosure: 9 to 32 V DC
FISCO: 9 to 17,5 V DC
Housing Material
Drop protection
IEC
IEC
IEC
IEC
Menu Language
Electrical Data
ATEX &
ATEX &
ATEX &
ATEX &
0,7 W
Display
SIL
(Safety Integrity Level)
Specification
Cast aluminium
Stainless steel
ITK Version
H1 Device Class
H1 Prole Class
Function Blocks
Quiescent current draw
Execution time
CFF les
EN 61326 (1000V)
4.61
Link Master (LAS) selectable ON/OFF
31PS, 32L
1 x RB(s), 2 x AI (s) and 1 x TB (c )
15 mA
15 ms
Downloads available from Host system supplier or www.eldbus.org
POWER CONSUMPTION
1200
20.5 mA
1000
800
620
600
400
200
24 VDC
12
11
10
20
30
40 VDC
PERFORMANCE
Description
Specification
Linearity
Accuracy
0,4 mm (0.015")
Repeatability
Ambient Temp.
Humidity
Electromagnetic Compatibility
P R O B E S P E C I F I C AT I O N S
Description
Materials
Probe diameter
Probe length
Dead band
Probe
Float
Process seal
Upper
Bottom
Specification
13
A P P L I C AT I O N D ATA S H E E T
Direct Insertion - Jupiter Level Transmitter
Customer name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quote reference #: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Email address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Process media: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33 cm
(13")
Primary oat
(for total or interface level
specied in model number)
General information
Inner diameter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Is moderate vibration present?:
Y/N
Please describe: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
...............................................
Is turbulence or ow present?:
Y/N
Active span
Probe order length
Secondary oat
(for dual-level measurement)
Please describe: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
...............................................
If SIL 2 is not required, disregard the additional 5,1 cm (2") dead zone
when specifying the probe order length
ELECTRICAL WIRING
HART key
0%
100 %
Standard shielded
twisted cable
recommended.
Ex
Non Ex
15
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN,
THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2008 AND OUR TOTAL COMPANY IS COMMITTED TO
PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
:2008
ALL JUPITER 200 LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE FULL YEAR
FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED
UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN
TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION
OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.
BULLETIN N:
EFFECTIVE:
SUPERSEDES:
DEUTSCHLAND
INDIA
ITALIA
U.A.E.
UNITED
KINGDOM
Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. +44 (0)1444 871313 Fax +44 (0)1444 871317 E-Mail: sales@magnetrol.co.uk
www.magnetrol.com
BENELUX
FRANCE
BE 46-148.2
APRIL 2012
July 2011