Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Crossroads Development Property Sewer Line Extension

Beckley , WV
TABLE OF CONTENTS

General Description

Location Map

FEMA NFIP Flood Map

Design Calculations

Form EG-4

Form ES-69

Crossroad Development Property, LLC


Crossroad Development Property Sewer Line Extension
Beckley, West Virginia
Project Description

Crossroad Development Property, LLC, with the City of Beckley, is proposing to install approximately
1,210 feet of 8 inch SDR 35 gravity sewer line off Route 16 also called Robert C. Byrd Drive. This
proposed sewer line extension will serve 4 proposed restaurant sites with each site having an estimated
seating of 300. The sewer extension will be connected to an existing line in the subdivision that will tie
to the sewer line installed to serve Crossroad Chevrolet.
Please find attached the information, plans, and details required to submit a permit for a sewer line
extension.

DESIGN CALCULATIONS
FOR
CROSSROAD DEVELOPMENT
SEWER LINE EXTENSION

AVERAGE DAILY FLOW


ADF= Number of sites x gallons per day per seat x number of seats per site

proposed sites=
gpd/seat=
seats per site=

4
30
300

36,000 ADF

PEAK FLOW
Peak flow = 2.5 x ADF
Peak flow=

2.5 x

36,000 ADF=

90,000 gpd

Hydraulic Radius
R = A/P
Using a 8 in diameter pipe.
R = Hydraulic Radius (ft.)
A = Cross-sectional Area of Flow (sq. ft.)
P = Wetted perimeter (ft.)

0.17
0.35
2.09

ft
sq ft.
ft

0.33
0.35

ft
sq ft

2.09
0.33

ft
ft

Area

A= r2
r = radius of pipe
A = area
Wetted perimeter (ft.)

P = 2r
P = Wetted perimeter (ft.)
r = radius of pipe

DESIGN CALCULATIONS
FOR
CROSSROAD DEVELOPMENT
SEWER LINE EXTENSION

Velocity
V = Q/A
V = Velocity
Q = Discharge
A = Area

0.40
0.14
0.35

ft/sec
cu. ft/sec
sq ft

Manning's Formula
Slope of pipe (from design) =

0.03 ft/ft

Assuming flowing full


slope of pipe = ((V x n) / (1.49 x R.66))2

Q = Discharge (cu. ft./sec.)


A = Cross-sectional Area of Flow (sq. ft.)
n = Coefficient of Roughness
R = Hydraulic Radius (ft.)
S = Slope of Pipe (ft./ft.) (Calculated)

0.14
0.35
0.013
0.17
0.00013

Slope designed is less than what is required so check is good.

cu ft. / sec
sq. ft.
ft.
ft./ft

EG-4
06/2010
WEST VIRGINIA DEPARTMENT OF HEALTH AND HUMAN RESOURCES
Bureau for Public Health
Office of Environmental Health Services
350 Capitol Street, Room 313
Charleston, WV 25301-3713
Phone: 304-558-2981 Fax: 304-558-0691

T
SEWAGE SYSTEM INFORMATION AND DESIGN DATA SHEET
Complete all portions of the Design Data Sheet applicable to the project. Omission of required information will
result in the application being denied. When both sewer system and water system are to be constructed, Design Data
Sheets for both sewage and water must be completed and attached to the application.

Applicant

Crossroad Development Property, LLC

Project Location Robert C. Byrd Drive


County

Raleigh

Total area of site 6.25


Type of development

acres

Area to be developed 6.25

Commercial

Industrial

Existing
Number of

acres
Residential

Proposed

home sites
mobile home sites
camping trailer sites
camp sites

4 restaurants

other
Can development be expanded?

yes

no

If so, to what number?

Sewer line material (ASTM, AWWA or ANSI designation)


Length of sewer lines of each
size

1210 feet 8 inch line

Number of manholes/cleanouts 1 existing manhole/ 5 proposed manholes


Pump/lift station capacity, gpm n/a
Distance of sewer lines from water lines (horizontal/vertical)

10'

1.5'

You might also like