NextGenerationImplantology
Product Catalogue
2014
GenXT
Published by TRATE. We reserve the right to make amendments without notice. All rights reserved.
No information published in this catalogue may be used the written agreement of TRATE, Switzerland.
Questions, comments, and requests can be sent by e-mail to support:GenXT.ch. Website address: www.GenXT.ch.
This catalogue, "GenXT 2014", is valide from 1 January 2014 untill the publication of the next catalogue.
Note: For the purpose of legibility, TRATE does not use or in the text.
This does not affect TRATE's rights with regard to registered trademarks.
Disclaimer: some products may not be available in all markets. Please contact your local TRATE representative
to review the product range available. Images of devices in this catalogue may differ from the actual devices.
GenXT
NextGenerationImplantology
Contents
2
21
29
39
Educational Material
GenXT
Next Generation Implantology
iGenXT Dental Implants is a result of our constant interaction with researchers
and leading Implantologists, all focused on creating a treatment modality that
has the patients comfort at its center. Simplicity, ease of placement & resoration,
and predictable long term results our are key goals. With these goals in mind we
have created 3 Implant systems within a single platform that can answer the
needs of your patients.
GenXTConcepT
Implantology began with creativity and innovativeness. Somewhere along the
way this was lost, and a monotonous treatment plan was adapted to every patient
This was because of limited understanding of concepts at that time and limitations
in manufacturing. We decided to change that, instead of the doctor and patient
adapting to the limitations of the implant system. We created a system based on
simple biological principles, engineered in a way so that the system adapts to the
doctors innovativeness and patients demands. Ever felt limited by your tools,
GenXT provides with with the tools to excel.
GenXTConcepT
Clinical Viability
Innovative Research
Biologic principles
GenXT
ISO
9001
Medical devices
Quality
management
Quality
management
The fact that we have our own global distribution network allows us to guarantee
high levels of service.
GenXT
Support
TRATE representatives are on hand to help you with any questions you may have
about the GenXT system. They can also assist you in using our online shop.
You can contact our representatives directly or via the form on the website.
Training
We provide a full range of training services to help clinics and laboratories introduce
the GenXTCONCEPT. An online course is available for everybody, 24 hours a day.
For more detailed information, please visit our website at www.GenXT.ch.
The resource at www.GenXT.ch has an intuitive and simple interface designed to cover everything
required in daily practice. It also provides a forum for you to exchange information with colleagues.
Guarantee
Al products are guaranteed for ten years. We liaise closely with our clients
and guarantee to replace failed implants, including the superstructures for reintegration.
Patients literature
We care about your relationship with your patients, so we provide free literature for patients.
A complete literature aimed at patients can be found at the end of this catalogue
and at the online shop.
GenXT
ROOTFORM
ROOTFORM
Rootform
implants
GenXT
Improved platform
precision internal hex
single platform for all diameters
reliable bonding with superstructures
convenient set of superstructures
ROOTFORM
Double strength
conical implant body shape
cylindrical thread shape
Thread structure
decompression groove
the decompression groove not only reduces bone compression,
but also increases the surface area of the intraosseous part
of the implant
Apical part
sharp, deep thread
compact structure
apical self-tapping blades
straight apical platform
GenXT
Cervical part
quadruple-start microthread radial structure
treated surface
the microthread in the cervical part means
that the implant couples gently with the compact
hard part of the bone and protects it against breakage
ROOTFORM
Thread structure
double thread
thread pitch reduces in the apical direction
three-component thread
m-shaped apical part
n-shaped middle part
n-shaped pre-cervical part
GenXT
Two-component root-form screw implant with active thread.
Suitable for single and multiple restorations with immediate and
delayed loading in the upper and lower jaws in all types of bone tissue.
Implant can be placed by flap or flapless approach. Implant placement is
also possible immediately following tooth extraction, as long as
ROOTFORM
Logic of selection
10
GenXT
8 mm
3.8 mm
4.2 mm
5.5 mm
R3808
R4208
R5508
10 mm
R3510
R3810
R4210
R5510
12 mm
R3512
R3812
R4212
R5512
14 mm
R3514
R3814
R4214
R5514
16 mm
R3516
R3816
R4216
R5516
ROOTFORM
3.5 mm
All ROOTFORM
implants are
supplied with a
SC cover screw,
AT2 abutment
with transfer function
and transfer cap
TS
Form drilling
Initial drilling
Use Drills in Sequence till Implant Diameter
Pilot drilling
Check depth
and direction
Implant
positioning
R3810
1200-1500
900-1200
200-800
Sequential drilling with form drills of increasing diameter.
If the bone density is insufficient, we recommend reducing
the drill diameter by one step or positioning after pilot drilling.
25-35
11
GenXT
Gingiva former
Anatomical
Should be used in all cases except narrow spaces and
GF1
GF2
1 mm
2 mm
ROOTFORM
GF3
GF4
3 mm
4 mm
Narrow
Used where there is insufficient space to place
GFN1
GFN2
1 mm
2 mm
GFN4
4 mm
Preparation of individual
gingival formers
Used to create the required gingival contour in aesthetically
important areas, generally along with surgical correction
of the gum contour. Where necessary, it can be used
GFI
12
GenXT
Transfers
TO
ROOTFORM
WARNING!
Do not use if there is insufficient clinical height for placement
in the distal parts of the upper and lower jaws or if implant axes
diverge by more than 10.
ST
AT2
TC
TR17
TC
13
GenXT
Implant analogue
Metal analogue
Used for model preparation. The special shape prevents
macro- and micro-mobility during milling, with a minimal internal
diameter, without preventing preparation of split models.
ROOTFORM
AN
Fixing screw
Laboratory
Used at the laboratory stages. Anodised green to avoid
incorrect use during fixation of abutments in the oral cavity.
Supplied with all abutment types.
SL8
Clinical
Used for permanent fixation of abutments in the oral cavity
with a force of 30 Ncm. The structure and material used prevent
unwanted damage to the screw during use.
Supplied with all abutment types in individual pack.
S8
14
GenXT
Abutments
1 mm
2 mm
3 mm
4 mm
Anatomical
Should be used for creating cemented constructions.
The gingival part has been designed on the basis
of detailed analysis of the cervical zone of the natural
Straight
ROOTFORM
WARNING!
Do not use for creation of single cemented
constructions in the masticatory area,
in narrow spaces, or for placing implants
at gum level or above.
Angled, 15
Angled, 25
Transgingival
Used for creating of single cemented constructions
in the masticatory area and for preparing
AT1
1 mm
AT2
2 mm
AT3
3 mm
AT4
4 mm
15
GenXT
Burnout cap
Used for preparation of high-precision metal body for precise alignment
and to prevent cementing failure, which is extremely important when creating
single cemented constructions in the masticatory area.
BP
ROOTFORM
Narrow
Used to create cemented constructions when there is insufficient space
to place an anatomical abutment and when implants are placed at or above
gum level. Supplied with an individually packed SL8 laboratory fixing screw
and S8 clinical screw.
A1N
B1
1 mm
BCW
Standard
retention
16
B2
2 mm
BCP
Soft retention
B3
3 mm
B4
4 mm
BCY
Extra-soft
retention
B5
5 mm
HBC
Holder
B2A17
2 mm
Angled 17
PD
Protective disc
GenXT
AB
ROOTFORM
WARNING!
A burnout abutment with hex on a metal platform should be used for high precision.
ABR
ABM
WARNING!
Should be used with individual gingival former.
17
GenXT
Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)
ROOTFORM
16 mm
14 mm
12 mm
10 mm
8 mm
Pilot drill
2 mm
8 mm
Form drill
3.5 mm
D2008
10 mm
3.8 mm
4.2 mm
5.5mm
D3808
D4208
D5508
D2010
D3510
D3810
D4210
D5510
D2012
D3512
D3812
D4212
D5512
D2014
D3514
D3814
D4214
D5514
D2016
D3516
D3816
D4216
D5516
12 mm
14 mm
16 mm
Drill extender
ET
TP4
Punch
4.0 mm
18
TP5
5.0 mm
TP6
6.0 mm
Initial drill
D1508
Guide pin
P2
1.5 mm, L8 mm
GenXT
Extended version
IT
ITL
ITH
ITHL
SD
SDL
SDH
SDHL
SDM
SDML
Instrument tray
TRR
Ratchet wrench
RW
TW50
DPG
ROOTFORM
Standard length
19
COMPRESSIVE
COMPRESSIVE
Compressive
implants
21
GenXT
COMPRESSIVE
Implant neck
special design
polished surface
Apical part
Minimal dimensions
22
GenXT
Intraosseous part
special compression thread
radial microthread space
tapered
apical part - small diameter
middle part - medium diameter
COMPRESSIVE
when inserting into cancellous trabeculae, the special compression implant thread
produces compression, creating a layer of cortical bone around the implant,
with reliable macrofixation
allows immediate implant loading with high primary stability
this compact layer then transforms into cancellous bone,
which is accompanied by osseointegration
Osseointegrated zone
180 days after
implant positioning
23
GenXT
COMPRESSIVE
Immediate loading
Excellent primary stability in all types of bone
Adjustable abutment angle
Resistant to cervical fractures
Logic of selection
24
GenXT
3.5 mm
8 mm
4.0 mm
4.5 mm
5.0 mm
5.5 mm
C4008
C4508
C5008
C5508
10 mm
C3010
C3510
C4010
C4510
C5010
C5510
12 mm
C3012
C3512
C4012
C4512
C5012
C5512
14 mm
C3014
C3514
C4014
C4514
C5014
C5514
16 mm
C3016
C3516
COMPRESSIVE
3.0 mm
25
GenXT
Transfers
Used to take closed transfers of single-component implants. The transfer construction
provides reliable fixation of the transfer in the tray. The preferred material for transfer is
Addition Silicon. The transfer can be modified in case of restricted space.
TRA
Implant analogue
Used for model preparation. Use of plastic provides the model with elasticity corresponding to
the micromobility of the implant. The special antirotation shape prevents macromobility while
working with the analogue, maintaining minimal size preventing interference with placing
when implants are close together.
ANA
Burnout cap
COMPRESSIVE
Used to prepare high-precision metal body for precise alignment and to prevent cementing
BOP
failure. The round indicator which matches to the indicator on the abutment shows
the height adjustment of the abutment. The opening in the upper part of the burnout cap,
combined with the colour contrast (red-yellow), gives an accurate impression of the fit
on the analogue, preventing misalignment in clinical situations. Available in Straight , 15
degree , 25 degree and shoulder margin patterns.
Form drilling
Initial drilling
Check depth
and direction
Use expansion
Screw if
Required
Implant
positioning
C3010
800 - 1200
1200-1500
Sequential drilling with cone drills of increasing diameter.
If the bone density is insufficient, we recommend reducing
the drill diameter by one step or positioning after pilot drilling.
26
15-25
GenXT
Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)
3.0 mm
3.5 mm
4.0 mm
5.0 mm
5.5 mm
8 mm
4.0 mm
5.0 mm
5.5 mm
DC5008 CS5008
DC5508 CS5508
10 mm
DC3010 CS3010
DC3510 CS3510
DC5010 CS5010
DC5510 CS5510
12 mm
DC3012 CS3012
DC3512 CSS3512
DC5012 CS5012
DC5512 CS5512
14 mm
DC3014 CS3014
DC3514 CS3514
DC5014 CS5014
DC5514 CS5514
16 mm
DC3016 CS3016
DC3516 CS3516
COMPRESSIVE
3.0 mm
27
GenXT
Initial drill
D1508
1.5 mm, L8 mm
Punch
TP4
TP5
ITEH
ITEHL
ITE
ITEL
Extended version
ITEXL
Extraextended version
COMPRESSIVE
Standard length
TP6
28
Instrument tray
TRR
Ratchet wrench
RW
TW50
DPG
BASAL
BASAL
Basal
implants
29
GenXT
Implant neck
Special design
Polished surface
Depending on the length of the implant the abutment can be bent from
15 - 25 degrees , as long as the implant is placed in sound bone
polished surface protects from accumulation of bacteria
at the cervical part of the implant
BASAL
Surface
Polished surface
Implant body
Thin implant body combined with wide thread turns
30
GenXT
Sizes
large diameter
short height
Integration
BASAL
31
GenXT
BASAL implants are used to create multiple unit restorations in the upper
and lower jaws. They can be placed in extraction sockets and also in healed
bone. The structural characteristics allow placement in bone that is deficient in
height and width. They can be placed with flap or flapless technique.
A good understanding of the maxillofacial anatomy is recommended so that
bi-cortical engagement is achieved. Can be used to bypass the mandibular
nerve, and for engagement of the cortical bone at the fusion of the pterygoid
with the maxilla. Can be used in combination with compressive implants.
Using a special instrument abutment direction can be adjusted up to 15
relative to the implant axis.
Logic of selection
BASAL
32
10 mm
12 mm
14 mm
16 mm
18 mm
20 mm
22 mm
24 mm
26 mm
3.5 mm B3510
B3512
B3514
B3516
B3518
B3520
B3522
B3524
B3526
4.5 mm B4510
B4512
B4514
B4516
B4518
B4520
B4522
B4524
B4526
5.5 mm B5510
B5512
B5514
B5516
6.5 mm B6510
B6512
B6514
B6516
8.5 mm B8510
B8512
B8514
10.5 mm B1110
B1112
B1114
BASAL
GenXT
33
GenXT
Transfers
Used to take closed transfers of single-component implants. The transfer construction
provides reliable fixation of the transfer in the tray. The preferred material for transfer is
Addition Silicon. The transfer can be modified in case of restricted space.
TRA
Implant analogue
Used for model preparation. Use of plastic provides the model with elasticity corresponding
to the micromobility of the implant. The special antirotation shape prevents macromobility
while working with the analogue, maintaining minimal size preventing interference with
ANA
Burnout cap
BOP
Used to prepare high-precision metal body for precise alignment and to prevent cementing
failure. The round groove which matches the groove on the abutment can be used as a
reference for the height adjustment of the abutment. The opening in the upper part of the
burnout cap, combined with the colour contrast (red-yellow), gives an accurate impression of
the fit on the analogue, preventing misalignment in clinical situations.
BASAL
Initial drilling
Implant
positioning
B4514
34
1200-1500
1200-1500
15-25
GenXT
Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)
20 mm
Expansion
screws
Form drills
22 mm
24 mm
26 mm
BASAL
20 mm
2.0 mm
DB2020
DB2022
DB2024
DB2026
CS8514
CS1114
D2016
35
GenXT
Initial drill
D1508
1.5 mm, L8 mm
Punch
TP4
TP5
ITEH
ITEHL
ITE
ITEL
Extended version
ITEXL
Extraextended version
COMPRESSIVE
Standard length
TP6
36
Instrument tray
TRR
Ratchet wrench
RW
TW50
DPG
GenXT
Information
for clinics
and patients
39
GenXT
TRATE can provide a complete set of documents for communicating with patients.
These documents which use plain language and clear illustrations, are useful
for patients and dentists alike. They help patients decide how to solve problems
due to damage or loss of a single tooth, several teeth, or complete edentulation.
GenXT
Bring back your smile!
Poster
REF 0110 English
REF 0111 German
REF 0112 Russian
GenXT
GenXT
Poster
REF 0210 English
REF 0211 German
REF 0212 Russian
GenXT
Living with a denture
or with no teeth?
Poster
REF 0310 English
REF 0311 German
REF 0312 Russian
40
Poster
REF 0410 English
REF 0411 German
REF 0412 Russian
GenXT
Catalogue of implantation
used by the Open Dental Community
Catalogue
of implantation
Catalogue
of implantation
This series of documents will help you to illustrate the possible missing tooth replacement solutions
during consultations. Solutions are based on the document "Catalogue of implantation used
by the Open Dental Community", which gives the patient confidence in the proposed treatment.
After treatment
Special patient brochure - "Life with a smile" - which helps maintain dentist-patient relations
after treatment. The brochure includes information about your clinic in the form of a tear-off
card with your contact details so the patient can always find you in emergencies or for further
advice. It is also a guarantee to the patient that you use high-quality TRATE products.
General information about implants, advice on hygiene and the need for regular check-ups.
The brochure provides information about TRATE's implant and superstructure guarantees.
The brochure includes pages for entering post-implantation guidance. TRATE recommends
use of the "Life with a smile" brochure after each implantation to boost patient confidence.
Ref 0600 English
Ref 0601 German
Ref 0602 Russian
For further information on how TRATE can help you communicate with patients,
visit our website at www.GenXT.ch or contact your TRATE representative.
41
GenXT
Notes
42
GenXT
43
GenXT
44
REGIONAL OFFICES
Belarus
TOP RATE IMPLANTS, OOO
Kiseleva st.55-11
220002 Minsk
Latvia
TRATE AG office in Latvia
ertrdes st. 109-1
1009 Riga
Lithuania
TRATE AG office in Lithuania
Vilniaus st. 31/1 (4th Floor, Room No. 6)
01402 Vilnius
Poland
TRATE AG office in Poland
G rczewska st. 24, m.58
01147 Warszawa
Russia
TOP RATE IMPLANTS, OOO
Rustaveli 14-6
127254 Moscow
Spain
TRATE AG office in Spain
Calle de Santiago 19-21
47001 Valladolid
Ukraine
nstitut Botehnologj
Srbnokl's'ka st.12, sekcja B
02068 Kiev
REF. CATALOG 12 Printed in Switzerland TRATE AG, 2012. All rights reserved.
The TRATE logo and other trade marks are registered trade marks of TRATE, unless otherwise stated in the text.
Images of implants at scale 1:1.25
TRATE AG
Seestrasse 58
8806 Bch
Switzerland
India
Mr. Bhalotia
Info@genxtimplantology.com
Genxtimplantology.com