Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Reference manual, guide for installation and use

Models
M-2, M-4A, M-6APU, M-6APE, M-66A,
M-266A, M-6ARO, M-6AOP, M-6APUMV,
M-6APEMV,M-6AOPMV, M-66AMV, M-8A,
M-88A, M-88AFO, M-6-8APU,M-6-8 APE
,M-66-8A T-6P, T-6A, M-33ID, M-77ID, M-72ID

Model numbers
The fountain model is indicated on the characteristics label, placed on the side of the
fountain.
M-2
Water fountain for room temperature water with pedal (M-2APE) or button
(M-2APU). Completely manufactured in A-304 stainless steel, directly connected
to water net. Optional: purifying filter.
M-4A
Wall-mounted water fountain. Completely manufactured in A-304 stainless steel,
directly connected to water net. Optional: purifying filter & cup filler (LV).
M-6APU
Water fountain with press button. Completely manufactured in A-304 stainless
steel, directly connected to water net. Optional: purifying filter & cup filler (LV).
M-6APE
Water fountain with pedal. Completely manufactured in A-304 stainless steel,
directly connected to water net. Optional: purifying filter & cup filler (LV).
M-66A
Water fountain with cold (pedal), room temperature (button) & average water
(pedal+button). Completely manufactured in A-304 stainless steel, directly
connected to water net. Optional: purifying filter & cup filler (LV).
M-266A
Water fountain with hot (glass filler), cold (pedal), room temperature (button) &
average water (pedal+button). Completely manufactured in A-304 stainless steel,
directly connected to water net. Optional: purifying filter.
M-6ARO
Round shaped room temperature water fountain with press button. Completely
manufactured in A-304 stainless steel, directly connected to water net. Optional:
purifying filter & cup filler (LV).
M-6AOP
Water fountain automatic operated by optic sensor. Completely manufactured in
A-304 stainless steel, directly connected to water net. Optional: purifying filter &
cup filler (LV).

M-6APEMV
Adaptation MV of our model M-6APU, designed for handicapped people in
wheelchairs, sensor operated by photoelectric cell.
M-6APEMV
Adaptation MV of our model M-6APE, designed for handicapped people in
wheelchairs, sensor operated by photoelectric cell.
M-6AOPMV
Adaptation MV of our model M-6AOP, designed for handicapped people in
wheelchairs, sensor operated by photoelectric cell.
M-66AMV
Adaptation MV of our model M-66A, designed for handicapped people in
wheelchairs, sensor operated by photoelectric cell.
M-8A
Large flux water fountain with swan neck for filling receptacles button operated.
Completely manufactured in A-304 stainless steel, directly connected to water
net. Optional: purifying filter.
M-88A
Large flux water fountain with swan neck for filling receptacles and jet water
button operated. Completely manufactured in A-304 stainless steel, directly
connected to water net. Optional: purifying filter.
M-88AFO
Large flux cooled water fountain with swan neck for filling receptacles and jet
water button operated with cold (pedal), cook (button) & average water
(pedal+button). Completely manufactured in A-304 stainless steel, directly
connected to water net. Optional: purifying filter.
T-6P
Water fountain push button operated. Externally finished in plastic coated steel,
directly connected to water net. Interior made in corrosion-resistant steel.
Optional: purifying filter & cup filler (LV).
T-6A
Standing water fountain push button operated. Externally finished in stainless
steel, directly installed into the water net. Interior made in corrosion-resistant
steel. Optional: purifying filter & cup filler (LV).

M-33ID
Table top room temperature & cold POU (point of use) water cooler. Externally
finished in A-304 stainless steel, directly connected to water net. Optional:
purifying filter.
M-77ID
Standing room temperature & cold POU water cooler. Externally finished in A304 stainless steel, directly connected to water net. Optional: purifying filter.
M-72ID
Standing hot & cold POU water cooler. Externally finished in A-304 stainless
steel, directly connected to water net. Optional: purifying filter.

Installation - Connection

Caution in transport

The fountain must be transported in vertical position. If transported in horizontal
position, the fountain must rest unplugged in working position (vertical) at least 24
hours.
.
. 24 )(
Installation

Dont put the fountain in places where the sunlight can affect it directly or near heat
machines, like heaters, radiators, boilers, etc.

. ...
Separate the water cooler at least 5 cm (2) from the wall.
. )( 5
We recommend doing the water line installation with copper pipe, do not using
plastic pipes, because with time they impregnate of rare tasting, difficult to eliminate.
4

Before to connect the fountain let the water flow from the pipe until it becomes
crystalline in order to drain the water net.

.
Water pressure for installation:
:

Minimum: 2 bar (200Kpa)


( 200) 2 :
(If the water pressure is lower, the coolers M77ID,M72ID,M33ID might make
some noise)
M77ID )
. M33ID M72ID

Maximum8 bar (1200 KPa)


( 1200) 8 :
The models M77ID,M72ID,M33ID M33ID have a water pressure regulator that
is set at a value at the factory. If the pressure of the installation is different,
the cooler can vibrate or make noise, in order to avoid this, it is
recommended to fit the pressure regulator.

.
SEE HOW TO HANG THE M-4 ON THE WALL (page 9)
(9 )M-4
Purification filter C-117
Place a water inlet valve between the water main and the cooler or the filter using a
inch fitting.
Place the filter the nearest to the fountain, after the water inlet valve, usually it is
connected directly to the fountain water inlet. In this case, fountain and filter
become one component to connect to the water net.
In order to put correctly the purification filter, the arrow engraved in the lid has
to indicate the water flow direction.
5

Before to connect the fountain bled the water main by leaving to flow the water
until it leaves crystalline.
Wasted water connection (Except M-3ID, M-77ID, M-72ID models)
(M-72ID M-77ID M-3ID )
Connect the 30 mm (1.2) diameter wasted water outlet to the waste water line. The
waste line must be under the water receptor.
The models M-66, M66ALV,M6APU,M6APULV, M6APE, M6APELV should be mountain with the
original Canaletas waste water tube.
. ( 1.2) 30
M6APU M- .
M6APELVM6APE M6APULV
. 66ALV

Use Setup
-
Caution in M-266A, M-72ID models

If the hot water tank were emptied the fountain could be


damaged.
IMPORTANT

Let some water out through the hot water tap, to check that the
water tank is full before connecting the hot water switch located on
the side of the fountain.
If the fountain is out of use all night or during some days it is advisable to turn off the
hot water switch.
Caution in M-33ID, M-77ID, M-72ID models
The internal coil must be emptied in order to avoid the water overflow when
inclining the water cooler. To do this you must close the water supply and keep open
the water outlet tap or by pushing the lever until the water stops flowing.
Water jet adjust (except M-33ID, M-77ID, M-72ID models)
(M-72ID M-77ID M-33ID )
6

In all our models with jet & anti-squirt bubble receptor the water jet can be adjusted
)in order to have the jet over the bubble. The jet height has to be between 9 cm (0,3
and 13 cm (0,5) over the water receptor.

. 9 ) 0.3( 13 ) 0.5(
.
Pedal operated models

The adjustment valve is on the coolers upper-back. Turn the adjust screw clockwise
to increase the water flow.
.
.
Sensor operated models

The adjustment valve is on the coolers upper-back. Turn the adjust screw clockwise
to decrease the water flow.
.
.
Push button operated models

The adjustment valve is under the button. Untwist the hexagonal stainless steel
nut; the adjustment screw is located inside. Turn the adjustment screw clockwise
to increase the water flow.
.
. .
Lever operated, models with glass filler

The adjustment cylinder is under the lever. Untwist the long spout. Extract by
pushing the lever horizontally. Turn the cylinder clockwise to increase the water
flow.
.
. .

Electric connection
7


IMPORTANT:

:
Check that the power supply is the same as the one stated on the side of the
fountain and set the plug in accordance to national rules, and then insert the plug
Earth connection is imperative. After installation, , the plug should be visible and
accessible.


.
. .
Cold water temperature control

In M-4A model the thermostat is underneath the fountain.
. M-4A
In the rest of models the thermostat is visible on the rear of the fountain.
.
Its adjusted between 5 and 10 Celsius and can be changed by turning the dial.
Turn clockwise in order to obtain colder water.
10 5
. .
Hot water temperature control in M-266A, M-72ID models
The thermostat is in the rear bottom of the cooler and is adjusted between 85
and 90 Celsius.
Can be changed by turning the dial. Turn clockwise in order to obtain hottest
water. Inside the dial there is a block cylinder. Its dangerous to

manipulate this because can allow water boil.


8

Use Instructions
-
1. Internal water tank emptied. There are two possibilities to empty the tank.

. . .1
Fountains with Canaletas filter (its not necessary to disconnect the water
entry)
( )
1. Close the water input valve.
. .1
2. Unscrew and draw out the filter drum allowing by this way allowing the
water exit.
. .2
3. Push the button/pedal or operate the sensor until the water flow stops.
. / .3

All fountains

1. Close the water input valve.


. .1
2. Draw out the cooler by this way allowing the water exit.
. .2
3. Push the button/pedal or operate the sensor until the water flow stops.
. / .3

2. Purify cartridge change in fountain with C-117 Canaletas purifying filter.


We recommend changing the purifying cartridge at least once per year, if possible
after holiday periods. Follow the instructions:
1.
2.
3.
4.
5.
6.

Empty the internal fountain tank unscrewing the filter drum as described in
section number 1.
Twist the filter drum without cartridge and open the water input valve.
Push the button/pedal or operate the sensor to let the chlorated water circulate
inside the fountain during two minutes at least.
Close the water input valve.
Unscrew and draw out the filter drum allowing by this the water exit.
Screw on the filter drum with a new cartridge and open the water input valve.
9

NOTICE ABOUT M-111 FILTER


You have to keep the stainless steel bottom filter supplement, which is inside the
filter because it is not supplied with the cartridges.

3. GAC Filter change


1. Close the mains water supply and unplug from power supply.
2. On Series 7 loose the condenser (1) from the hooks (2) by pulling.
3. Take out the filter from the bracket that is on the fountain (4).
4. Remove the filter tubes (5 and 6) and connect again the filter and verify
that water flow direction indicated on the filter is the same as water
input on tube 5 and output on tube 6.
5. Put the new filter on the bracket.
6. On Series 7 fix the condenser at its place with the hooks.
7. Open the water mains supply and plug to power supply.

4.Out of order fountains


.4
If the fountain has been unplugged from the electric supply during many days (e.g.
during the holidays) we recommend to empty the internal tank/direct coil as
described in section 1, in order to expel the existing water which could have been
corrupted due to not being cold enough.

10

) (
/ 1
.

Use Problems

-
The water doesnt flow when operating the tap.
.

Check the connection to the water line, and see that pressure is enough (3 atm.
minimum) and see that the water tap is turned full on.
) 3 . . (
.
Check there is no obstruction in the receptor, drain trap or line. If the fountain
has filter, check if there is any obstruction in the cartridge.
.
.
If the previous points have been checked may be the water has become ice in the
internal tank. Unplug the fountain during at least one day in order to allow the tank to
thaw. Turn the thermostat dial in order to reduce the cooling capacity.

.
. .
The water isnt chilled

Check the fountain is plugged in and that the current is the right one.
.
Check that the thermostat hasnt disconnected the fountain, if necessary turn the
dial in order to connect the fountain again or increase the cooling capacity.
11


.
The water in the receptor doesnt evacuate

Check there isnt any obstruction in the wasted water line.


.
Check that any object doesnt obstruct the fountain receptor, trap and drain.
.

If the problem persists contact an Authorised Reseller or Canaletas Service


Department.
.

To hang the M-4 on the wall


M-4
WARNING! Do not to plug in the fountain until this has been fixed to the wall
!
With the fountain there is a plastic bag with 2 screws, 2 hooks & 4 raw-plugs.
Follow these steps:
) (2 ) (4
. :
1.Mark in the wall a horizontal line 5 cm (1,97) below the height to which it is
desired to put the water receptor. We recommend, for adult use, a water receptor
height of 1 metre.
.1 5 ) 1.97(
.
.
2.In this line make 2 holes for 8 mm (0,31) raw-plugs 24 cm (9,45) apart. See
drawings N 1 & 2
.2 8 ) 0.31(
24 ) 9.45( . 1 .2
3.Put the 2 raw-plugs & hooks in the holes & turn them until there is a 5 mm
(0,20) gap from the wall.
0.20)3( ..
5
12

4.Hang up the fountain by the square hole at the back.


.4 .
5.Mark in the wall the two holes that are at the bottom part of the fountain. See
drawings N 3 & 4
.5 .
3 .4
)6.Take down the fountain again and make two holes on the wall for 8mm (0,31
raw-plugs. Put the raw-plugs on the holes .
.6 8 .
.
7.Hang up again the cooler on the wall and tighten the screws.
.7 .
8.Connect the water and electrical current.
.8 .

Points of fixation


Water inlet


Rear


Water outlet


13

National & International Guarantee

Canaletas guaranties to the original purchaser or other final user/purchaser of each


fountain, of a new brand, that all parts are free from defects in material and workmanship,
in normal conditions of use and service, for a period of:
10 years for the inside stainless steel chassis and 2 years for the rest of fountain parts
from the date of purchase. The 10 years guarantee only applies to models with
internal stainless steel chassis.

Canaletas, its Authorised Resellers and Service Providers reserve the right to request
proof of purchase (e.g. a paid and dated invoice from an Authorised Reseller) showing
fountain model and serial number before accepting liability for any Guarantee claim.

Canaletass sole obligation under this Guarantee shall be, at its option, to repair or replace
the product or any components free of charge, in the event of any failure or defect
covered by the Warranty arising during the Guarantee period.

This Guarantee is not valid if failure of the product or component is the result from
service, maintenance or repair not supplied by Canaletas Authorised Reseller or
Authorised Service Provider, or if the product or component labels/serial number has
been altered or darkened.

This Guarantee does not apply to any failure or defect attributable to any extrinsic cause,
accident damage, improper use, modification, adaptation or neglect.

Any product or component repaired or replaced under the Guarantee is subject to the
balance of the original Guarantee period applying to the product or component, or for
three months, whichever is the greater. All products and components replaced under
Guarantee are Canaletass property.

Canaletas will not be responsible for transport/delivery costs incurred in returning the
products or components to a Canaletas Authorized Reseller or Authorized Service
Provider. Canaletas reserves its right in Spain, excluding the Canary Islands, to pay the
transport cost to our facilities and delivery to its owner.

For more information contact us:

Canaletas S.A.
Ronda Llevant, 10
08820 El Prat de Llobregat- Barcelona (Spain)
Tel.: + (34) 902 117 096 Fax: + (34) 934 350 604
Email: infox@canaletas.es
www.canaletas.es
14