BWS 1600G Technical Manual
BWS 1600G Technical Manual
1-1
1-1
1-4
1-7
1-9
1-9
1-9
1-11
1-11
1-12
1-13
2-1
2-1
2-1
2-2
2-3
2-3
2-4
2-5
2-7
2-13
2-15
2-17
2-18
2-20
2-21
2-22
2-24
2-24
2-25
3-1
3-1
3-1
3-3
3-8
3-13
3-15
3-15
3-16
3-17
3-19
3-21
3-21
3-23
3-26
3-28
3-30
3-30
3-31
3-31
3-31
3-32
3-32
3-34
3-36
3-38
4-1
4-1
4-3
4-3
4-5
4-6
4-6
4-7
4-8
4-8
4-9
4-10
4-11
4-12
5 Protection ......................................................................................................
5-1
5-1
5-1
5-1
5-1
5-3
5-3
5-3
5-8
5-11
5-11
5-12
6-1
6-1
6-1
6-2
6-2
6-8
6-8
6-9
6-10
6-16
6-20
6-21
6-22
6-24
6-24
6-27
6-28
6-29
6-30
6-31
6-32
6-32
6-34
6-35
6-37
6-38
6-40
6-41
6-43
6-45
6-47
6-49
6-51
6-52
6-54
6-55
6-57
6-59
6-60
6-61
6-61
6-62
6-62
6-63
6-63
6-64
6-65
6-68
6-68
6-69
6-70
6-70
6-70
6-71
6-72
6-73
6-77
6-79
6-79
6-81
6-84
A-1
A-1
A-3
A-4
A-6
B-1
B-1
B-2
B-3
C-1
Index .................................................................................................................
HUAWEI
T2-040290-20041008-C-1.21
Product Version
V100
BOM
31025790
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service.
Please feel free to contact our local office or company headquarters.
Trademarks
, HUAWEI, C&C08, EAST8000, HONET,
, ViewPoint, INtess, ETS, DMC, TELLIN,
InfoLink, Netkey, Quidway, SYNLOCK, Radium, M900/M1800, TELESIGHT,
Quidview, Musa, Airbridge, Tellwin, Inmedia, VRP, DOPRA, iTELLIN, HUAWEIOptiX,
C&C08 iNET, NETENGINE, OptiX, iSite, U-SYS, iMUSE, OpenEye, Lansway,
SmartAX, infoX, TopEng are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this manual are the property of their
respective holders.
Notice
The information in this document is subject to change without notice. Every effort has
been made in the preparation of this document to ensure accuracy of the contents, but
all statements, information, and recommendations in this document do not constitute
the warranty of any kind, express or implied.
Summary of Updates
This section provides the update history of this manual and introduces the contents of
subsequent updates.
Update History
Manual Version
Notes
T2-040290-20040510-C-1.20
T2-040290-20041008-C-1.21
Volume
Usage
Routine
Maintenance
Troubleshooti
ng
Alarms and
Performance
Events
Organization
The manual is organized as follows:
Chapter
Description
Chapter 1 Overview
Chapter 2 Product
Description
Chapter 3 System
Configuration
Chapter 4 Network
Application and System
Functions
Chapter 5 Protection
Chapter 6 Technical
Parameters
Appendix A Measures in
DWDM Network Designing
Appendix B Technology
Introduction
Appendix C Abbreviations
and Acronyms
Intended Audience
This manual is intended for:
Network planner
Network designer
Network administrator
Conventions
The manual uses the following conventions.
Symbol Conventions
Symbol
Description
Means reader be careful. In this situation, you might do something that
could result in equipment damage or loss of data.
Means reader be careful. The equipment is static-sensitive.
Means reader be careful. In this situation, the strong laser beam could
result in harm to yourself or others.
Contents
Contents
1 Overview
1-1
1-1
1-4
1.3 Features
1-7
1.4 Characteristics
1-9
1-9
1-9
1-11
1-11
1.4.5 Reliabilty
1-12
1-13
2 Product Description
2-1
2.1 Cabinet
2-1
2.1.1 Overview
2-1
2.1.2 Specifications
2-2
2.2 Subrack
2-3
2.2.1 Structure
2-3
2.2.2 Specifications
2-4
2-5
2-7
2-15
2-17
2-19
2-20
2-22
2-23
Contents
2-24
2-26
2-26
2-27
3 System Configuration
3-1
3.1 OTM
3-1
3-1
3.1.2 Structure
3-3
3-8
3-13
3.2 OLA
3-15
3-15
3.2.2 Structure
3-16
3-17
3-19
3.3 OADM
3-21
3-21
3.3.2 Structure
3-23
3-26
3-28
3.4 REG
3-30
3-30
3.4.2 Structure
3-31
3-31
3-31
3.5 OEQ
3-32
3-32
3.5.2 Structure
3-34
3-36
3-38
4-1
4-1
4-3
4-3
4-5
4-6
Contents
4-6
4-7
4-8
4-8
4-9
4-10
4-11
4-12
5 Protection
5-1
5-1
5-1
5-1
5-1
5-3
5-3
5-3
5-8
5-11
5-11
5-12
6 Technical Parameters
6-1
6-1
6-1
6-2
6-2
6-8
6-8
6-9
6-10
6-16
6-20
6-21
6-22
6-24
6.7.1 OAU
6-24
6.7.2 OBU
6-27
Contents
6.7.3 OPU
6-28
6.7.4 WBA
6-29
6.7.5 HBA
6-30
6-31
6-32
6.8.1 LWF
6-32
6.8.2 LWFS
6-34
6.8.3 OCU
6-35
6.8.4 OCUS
6-37
6.8.5 TMX
6-38
6.8.6 TMXS
6-40
6-41
6-43
6.8.9 LWM
6-45
6.8.10 LWX
6-47
6.8.11 LDG
6-49
6.8.12 TWC
6-51
6.8.13 LGS
6-52
6.8.14 LQS
6-54
6.8.15 AP4
6-55
6.8.16 EC8
6-57
6.8.17 OTT
6-59
6-60
6-61
6-61
6-62
6.9.1 M40
6-62
6.9.2 D40
6-63
6.9.3 MB2
6-63
6.9.4 MR2
6-64
6-65
6-68
6.11.1 FIU
6-68
6.11.2 ITL
6-69
6.11.3 DGE
6-70
6.11.4 DSE
6-70
6.11.5 MCA
6-70
Contents
6.11.6 OSC
6-71
6.12 DCM
6-72
6-73
6-77
6-79
6-79
6-81
6-84
A-1
A-1
A-3
A-4
A-6
B Technology Introduction
B-1
B.1 FEC
B-1
B.2 SuperWDM
B-2
B-3
C-1
i-1
Index
Figures
Figures
Figure 1-1 OptiX BWS 1600G in transmission network
1-2
1-3
2-3
2-6
2-24
2-29
3-2
Figure 3-2 The structure of the OM, OD and OA of the type I system
3-5
3-7
Figure 3-4 The structure of OM, OD, OA of the type III, IV, V and VI systems
3-7
3-8
3-9
3-10
3-11
3-12
3-13
3-15
3-18
3-19
3-22
3-23
3-25
3-25
3-26
Figure 3-19 Configuration of C-band serial OADM equipment (type III system)
3-26
Figure 3-20 Configuration of C-band parallel OADM equipment (type III system)
3-28
Figures
3-30
3-33
3-33
3-34
3-34
Figure 3-26 Optical power equalization through the VMUX (the V40 board)
3-35
3-36
3-37
3-38
4-2
4-8
4-8
4-10
4-12
4-13
4-13
4-14
4-15
5-2
5-3
5-4
5-4
5-5
5-6
5-7
Figure 5-8 Schematic diagram of clock channel protection (dual-fed and dual-receiving)
5-8
Figure 5-9 Schematic diagram of clock channel protection (dual-fed signal selection)
5-8
Figure 5-10 Configuration of the system with clock protection function but without add/drop of clock signals at
intermediate station
5-9
Figure 5-11 Configuration of the intermediate station with clock protection function and with the add/drop of
clock signals
5-10
Figure 5-12 Configuration of the intermediate station with clock protection function and with the add/drop of
clock signals
5-10
Figure 5-13 Network management protection in ring network (a certain section fails)
5-11
5-12
5-12
5-13
Figures
6-8
6-60
6-60
6-61
A-3
B-3
B-3
Tables
Tables
Table 1-1 Characteristics of system types
1-5
2-2
2-4
Table 2-3 Application and description of wavelength conversion units (10 Gbit/s)
2-8
Table 2-4 Application and description of wavelength conversion unit (2.5 bit/s or lower)
2-10
Table 2-5 Application and description of convergent optical wavelength conversion unit
2-11
2-14
2-16
2-17
Table 2-9 Application and description of optical supervisory channel/timing transporting unit
2-18
Table 2-10 Application and description of performance monitoring & adjustment unit
2-19
2-21
2-22
2-23
Table 3-1 Functional units and the boards contained (six system types)
3-4
3-5
Table 3-3 Functional unit and the boards contained (five system types)
3-16
Table 3-4 Functional units and the boards contained (five system types)
3-24
4-3
4-4
4-4
4-4
4-5
4-5
Table 4-7 Networking capability of type III system (G.653 optical fiber)
4-6
4-6
Tables
4-6
4-7
4-14
4-15
4-16
6-2
6-8
Table 6-3 Main optical path parameters of the OptiX BWS 1600G-I system (G.652/G.655 fiber)
6-9
Table 6-4 Main optical path parameters of the OptiX BWS 1600G-II system (C+L, G.652/G.655 fiber)
6-10
Table 6-5 Main optical path parameters of the OptiX BWS 1600G-II ELH transmission system (C+L,
G.652/G.655 fiber)
6-11
Table 6-6 Main optical path parameters of the OptiX BWS 1600G-II (C, G.652 fiber)
6-12
Table 6-7 Main optical path parameters of the OptiX BWS 1600G-II (C, G.655 fiber)
6-14
Table 6-8 Main optical path parameters of the OptiX BWS 1600G-III system (G.652/G.655 fiber)
6-16
Table 6-9 Main optical path parameters of the OptiX BWS 1600G-III ELH transmission system (G.652/G.655
fiber)
6-17
Table 6-10 Main optical path parameters of the OptiX BWS 1600G-III 8-channel system (G.653 fiber)
6-18
Table 6-11 Main optical path parameters of the OptiX BWS 1600G-III 12-channel system (G.653 fiber) 6-19
Table 6-12 Main optical path parameters of the OptiX BWS 1600G-IV system (G.653 fiber, L band)
6-20
Table 6-13 Main optical path parameters of the OptiX BWS 1600G-V system (G.652/G.655 fiber)
6-21
Table 6-14 Main optical path parameters of the OptiX BWS 1600G-VI system (G.652/G.655 fiber, 10-channel,
without Raman)
6-22
Table 6-15 Main optical path specifications of the OptiX BWS 1600G-VI system (G.652/G.655 fiber,
40-channel, without Raman)
6-23
Table 6-16 Parameters of OAU-CG/LG for C/L-band
6-24
6-25
6-26
6-27
6-28
6-29
6-30
6-31
Table 6-24 Optical interface (STM64) parameters at the client end of the LWF board
6-32
Table 6-25 Optical interface (STM64) parameters at the DWDM side of the LWF board
6-33
Table 6-26 Optical interface (STM64) parameters at the DWDM side of the LWFS board
6-34
Table 6-27 Optical interface (STM16) parameters at the client end of the OCU board
6-35
Table 6-28 Optical interface (STM64) parameters at the DWDM side of the OCU board
6-36
Table 6-29 Optical interface (STM64) parameters at DWDM side of the OCUS board
6-37
Tables
Table 6-30 Optical interface parameters at client side of the TMX board
6-38
Table 6-31 Optical interface parameters at line side of the TMX board
6-39
Table 6-32 Optical interface parameters at line side of the TMXS board
6-40
Table 6-33 Optical interface parameters at client side of the LBE and LBES board
6-41
Table 6-34 Optical interface parameters at line side of the LBE and LBES boards
6-42
Table 6-35 Optical interface (STM16) parameters at client end of the LWC/LWC1 board
6-43
Table 6-36 Optical interface (STM16) parameters at the DWDM side of the LWC/LWC1 board
6-44
Table 6-37 Optical interface parameters at the client end of the LWM board
6-45
Table 6-38 Optical interface parameters at DWDM side of the LWM board
6-46
Table 6-39 Optical interface parameters at the client end of the LWX board
6-47
Table 6-40 Optical interface parameters at the DWDM side of the LWX board
6-48
Table 6-41 Optical interface parameters at the client end of the LDG board
6-49
Table 6-42 Optical interface parameters at the DWDM side of the LDG board
6-50
6-51
Table 6-44 Optical interface parameters at the client end of the LGS board
6-52
Table 6-45 Optical interface parameters at the DWDM side of the LGS board
6-53
Table 6-46 Optical interface parameters at the client end of the LQS board
6-54
Table 6-47 Optical interface parameters at the client end of the AP4 board
6-55
Table 6-48 Optical interface parameters at line side of the AP4 board
6-56
Table 6-49 Optical interface parameters at client side of the EC8 board
6-57
Table 6-50 Optical interface parameters at line side of the EC8 board
6-58
6-59
6-60
6-61
6-61
6-62
6-63
6-63
6-64
6-65
6-66
6-66
6-68
6-69
6-70
6-70
Tables
6-70
6-71
Table 6-68 Performance requirement of dispersion compensation optical fiber of C-band (G.652 fiber)
6-72
Table 6-69 Performance requirement of dispersion compensation optical fiber of L-band (G.652 fiber)
6-72
Table 6-70 Performance requirement of dispersion compensation optical fiber of C-band (G.655 LEAF fiber)
6-72
Table 6-71 C-band channel allocation (80 channels with 50GHz spacing)
6-73
Table 6-72 L-band channel allocation (80 channels with 50 GHz spacing)
6-75
6-76
6-76
6-79
6-80
6-80
6-81
6-81
6-82
6-82
6-83
6-84
6-84
6-85
6-85
6-86
A-5
1 Overview
Overview
1-1
1 Overview
160 channels
Backbone Layer
32 channels
32 channels
STM-16
OptiX Metro 6100
OptiX 2500+
OptiX 10G
STM-64
Convergence Layer
OptiX 155/622
OptiX 2500+
STM-4/1
OptiX 2500+
OptiX 155/622
STM-4
STM-16
STM-4/1
OptiX Metro 1000
OptiX Metro 3100
STM-4/1
Access Layer
The OptiX BWS 1600G transmits the unidirectional services over a single fiber, that is,
a bi-directional transmission is achieved by two optical fibers, one for transmitting and
the other for receiving.
The OptiX BWS 1600G is highly reliable in performance and flexible in networking by
using:
Reliable multiplexer/demultiplexer;
Raman amplifier;
Pre-chirp technology;
1-2
1 Overview
1-3
1 Overview
To meet the requirements of different areas, users and investing environments, the
OptiX BWS 1600G product provides six types of systems, respectively OptiX BWS
1600G-I, OptiX BWS 1600G-II, OptiX BWS 1600G-III, OptiX BWS 1600G-IV, OptiX
BWS 1600G-V, and OptiX BWS 1600G-VI.
For the convenience of description, OptiX BWS 1600G-I is referred to as the type I
system for short, and other types are the type II system, the type III system, the type IV
system, the type V system, and the type VI system. If there is no type identity, for
example, the OptiX BWS 1600G, it refers to all system types.
2. Characteristics of Each System Type
1-4
1 Overview
II
III
IV
VI
Maximum capacity
(Gbit/s)
1600
800
400
400
100
400
Working wavelength
band
C-band and
L-band
C-EVEN and
L-ODD (Note
1)
C-band
C-EVEN (Note 1)
L-ODD
(Note 1)
C-EVEN (Note
1)
C-EVEN
(Note 1)
Channel spacing
(GHz)
50
100
50
100
100
100
100
200
Maximum number of
channels
160
80
80
40
40
40
40
10
Maximum accessing
rate (Gbit/s)
10
10
10
10
10
2.5
10
Transmission
distance without REG
(km) (Note 2)
360
2000 (Note 3)
960/800
(Note 5)
2000 (Note 3)
400
640
200
Per-channel output
power of amplifier
(dBm)
4/1 (Note 6)
4/1/0 (Note 4)
12
Fiber type
G.652/G.655
G.652/G.655
G.652/G.655
G.652/G.653/G.655
G.653
G.652/G.655
G.652/G.655
Clock protection
function
Supported
Supported
Not
supported
Not supported
Not
supported
Not supported
Not
supported
Item
Type
1-5
100
17
II
Accessing service
type
SDH/SONET
/POS
SDH/SONET/
POS/GE/arbitr
ary service at a
rate of 34
Mbit/s 2.5
Gbit/s
Maximum numbers of
add/drop channels
32
Dispersion
compensation
Required
Item
Type
1 Overview
III
IV
VI
SDH/SONE
T/POS
SDH/SONET/POS/G
E/arbitrary service at a
rate of 34 Mbit/s 2.5
Gbit/s
SDH/SON
ET/POS
SDH/SONET/P
OS/GE/arbitrar
y service at a
rate of 34 Mbit/s
2.5 Gbit/s
SDH/SONET
/POS/GE/arbi
trary service
at a rate of 34
Mbit/s 2.5
Gbit/s
80
32
40
16
16
NA
Required
Required
Required
Required
Not required
Required
Note 1: C-EVEN indicates even channels (40 channels in total) in C-band and the L-ODD indicates odd channels (40 channels in total) in L-band.
Note 2: The data in the above table is for system without adopting Raman amplification technology. If the technology is adopted, the longer transmission distance
without REG will be supported. Here the distance is computed out with an attenuation coefficient of 0.275 dB/km.
Note 3: With technologies such as FEC, SuperWDM and optical equilibrium being applied, the transmission distance without REG reaches up to 2000 km in the type
II and the type III systems.
Note 4: Per-channel output optical power of the optical amplifier in the type III system is 4 dBm on G.652/G.655 fiber, and 1 dBm or 0 dBm on G.653 fiber.
Note 5: The data is for particular fiber and line code. The distance of 960 km is for G.652 fiber with return to zero (RZ) encoding and 800 km for G.655 fiber with RZ
encoding.
Note 6: The type II C800G system provides two types of amplifier. The output optical power of one type is 23 dBm, and that of the other type is 20 dBm.
By system channel spacing, the OptiX BWS 1600G system can be divided into two categories: 50 GHz channel spacing
system and 100 GHz channel spacing system, as can be seen in Table 1-1.
1-6
1 Overview
1.3 Features
1. Huge Transmission Capacity
Transmission capacity of the type II system can be upgraded from 400 Gbit/s to
800 Gbit/s. In a module of 400 Gbit/s capacity, the capacity can get increments with
10 Gbit/s.
Maximum transmission capacity of the type III/IV system is 400 Gbit/s. In a module
of 400 Gbit/s capacity, the capacity can get increments with 10 Gbit/s.
The type VI system, a long hop application, is classified as 10-channel system and
40-channel system. In the module, the capacity can get increments with 2.5 Gbit/s
or 10 Gbit/s.
When using forward error correction (FEC) technology, the system allows an
attenuation of 10%22 dB for transmission without REG.
When using technologies such as FEC, SuperWDM, and optical equilibrium, the
system allows an attenuation of 25%22 dB for transmission without REG.
When using FEC technology and optical amplification technology, the system
allows an attenuation of 56 dB in long hop application. Upon this result, the remote
optical pumping amplifier (ROPA) technology can extend long hop transmission up
to 64 dB transmission attenuation.
The OptiX BWS 1600G provides access to the following service types:
Other service: Services with rate from 34 Mbit/s to 2.5 Gbit/s, such as enterprise
system connection (ESCON) /fiber connection (FICON) /Fiber Channel (FC)/fiber
Huawei Technologies Proprietary
1-7
1 Overview
The optical supervisory channel mainly carries orderwire and network management
information. The OptiX BWS 1600G transmits supervisory signals at 1510 nm, with
the transmission speed of 2.048 Mbit/s.
The OptiX BWS 1600G also provides three high-quality clock transmission channels,
each at a transmission speed of 2.048 Mbit/s. The three clock transmission channels
are embedded into the optical supervisory channel.
5. Integrated System and Open System Compatibility
There are two types of DWDM system available: integrated DWDM system and open
DWDM system. The open DWDM system is configured with OTUs to convert
non-standard wavelengths into ITU-T G.694.1-compliant wavelength. The integrated
DWDM system does not need the OTUs when its client side equipment (for example,
SDH equipment) has ITU-T G.694.1-compliant optical transmitter interfaces. The
OptiX BWS 1600G achieves the combination of open and integrated system.
6. Centralized Intelligent Network Management
The OptiX BWS 1600G can be managed by the centralized intelligent NM due to its
excellent interconnectivity with other Huawei products.
1-8
1 Overview
1.4 Characteristics
1.4.1 Service Characteristics
1. Low-speed Service Aggregation
The OptiX BWS 1600G supports the aggregation of low-speed services. It can:
Multiplex one channel of GE signal and one channels of STM-4 signals into one
channel of STM-16 signal;
Multiplex four channels of STM-16 signals into one channel of OTU2 signal.
The OptiX BWS 1600G offers a new solution for transmission of synchronous clock.
Its optical supervisory channel provides three clock transmission channels operating
at 2 Mbit/s. The clock signals can be added/dropped or just pass through at any
station.
3. Scalable Optical Add/Drop and Multiplexing Technology
OTU in the OptiX BWS 1600G uses FEC and EFEC (enhanced FEC) technology to:
Decrease the bit error ratio (BER) in the line transmission, to improve the quality of
service (QoS) of DWDM transmission network.
AFEC and EFEC are relatively new error correction techniques which adopt two-level
encoding, have increase in encoding gain, and can equally distribute burst errors.
AFEC and EFEC are more powerful than FEC.
1-9
1 Overview
2. Tunable Wavelengths
The OptiX BWS 1600G provides optical tunable transponder (OTT), such as the LWF
board and OCU board. An OTT can operate at tunable wavelengths (totally 40
channels), to replace OTUs of different wavelength characteristics when necessary.
Ordering OTT as spare board greatly reduces the cost of spare parts, because not so
many spare OTUs are required.
3. Mature EDFA Technology
The OptiX BWS 1600G uses mature erbium-doped fiber amplifier (EDFA) technology
for amplification of C-band and L-band signals, and the accomplishment of long haul
transmission without REG. EDFA adopts gain locking technology and transient control
technology to make the gain of each channel independent of the number of channels.
Bit error bursts in the existing channels are also avoided during adding or dropping
channels.
4. Advanced Raman Amplification Technology
Besides the EDFA amplification, the system also supports Raman fiber amplification.
The hybrid application of the Raman and EDFA achieves broad gain bandwidth and
low system noise, and reduces the interference of non-linearity on the system, thus
greatly stretching the transmission distance.
5. Unique SuperWDM Technology
By using RZ encoding and unique phase modulation technology, the OptiX BWS
1600G is capable of effectively suppressing the non-linear impairments in
transmission and improving the noise tolerance capability. With the SuperWDM
technology, the OptiX BWS 1600G achieves ultra long haul application in the absence
of Raman amplifier.
6. Jitter Suppression
By adopting advanced jitter suppression and clock extraction technology, the jitter
performance of the OptiX BWS 1600G is better than the requirements defined by
DWDM related ITU-T Recommendations. OTUs of the system also check B1 and B2
bit errors, and extract J0 bytes. Thus when accessing the SDH equipment, the system
can quickly detect whether the bit error occurred to the SDH section or the optical path.
This function is of critical importance when the OptiX BWS 1600G system accesses
the SDH equipments of different vendors.
1-10
1 Overview
The system applies automatic level control (ALC) function to control the power along
the link, thereby ensuring the normal laser level in the optical fiber. The ALC function
keeps the optical signal at normal level and prevents the input/output power of the
downstream optical amplifiers from declining. This improves the quality of the
transmission signals.
2. Intelligent Power Adjustment
The intelligent power adjustment (IPA) protects the human body from the exposure to
the laser, which can be emitted from open interface or fiber cracks. If there is a
leakage of optical power, the system will reduce the optical power to that lower than
the safe threshold.
3. Automatic Power Equilibrium
In long haul transmission, the non-flatness of per-channel OSNR at the receiving end
becomes a serious issue. With the automatic power equilibrium (APE) function, the
OptiX BWS 1600G can automatically adjust the launched optical power of each
channel, thus achieving power equilibrium at the receiving end and improving the
OSNR. The APE is well suited for applications with many spans.
4. Intelligent Environment Temperature Monitoring System
The OptiX BWS 1600G is designed with intelligent system for environment
temperature monitoring, reporting and alarming. This ensures the normal running of
the system under a stable temperature.
The OptiX BWS 1600G offers an optical fiber line automatic monitoring system
(OAMS) to alert the aging of fiber, alarm the fiber fault and locate the fault. The OAMS
is a built-in system optional for ordering.
2. In-service Optical Performance Monitoring
1-11
1 Overview
spectrum analyzer unit (MCA) using optical fibers. With the help of MCA, optical
spectral features including the optical power, central wavelength and OSNR can be
observed from network management system.
1.4.5 Reliabilty
1. Perfect Protection Mechanism
The OptiX BWS 1600G provides perfect protection mechanism, including optical
channel protection, optical line protection and equipment-level unit protection.
The system clock is protected by 1+1 backup of clock unit.
2. Reliable Power Backup
The power supply system of the OptiX BWS 1600G is fed with two DC inputs (backup
each other). The power supply of important units is protected by 1+1 hot backup. The
power of OTU boards are protected by a common protection power feed.
3. Perfect Optical Fiber Management Function
The OptiX BWS 1600G fully considers the demands for optical fiber management.
Various cabling channels and fiber storage units are available to facilitate the fiber
management in the cabinet and between the cabinets.
1-12
1 Overview
1-13
2 Product Description
Product Description
The hardware of the OptiX BWS 1600G includes cabinet, subrack, power box, fan
tray assembly, DCM frame and HUB frame. The cabinet can hold subracks with
different board combinations to form different equipment types of OptiX BWS 1600G.
2.1 Cabinet
2.1.1 Overview
Compact and elegant design of the cabinet gives high space utilization. A Single
cabinet can hold at most three subracks, a power box, a frame for HUB, and a frame
for DCM.
A power box is mounted at the top of OptiX BWS 1600G cabinet. The OptiX BWS
1600G is powered with 48 V DC or 60 V DC. Two power supplies are provided as
mutual backup to each other. It also provides 16-channel external alarm input
interfaces and 4-channel cabinet alarm output interfaces, facilitating the management
of equipment running.
OptiX BWS 1600G cabinets have the following salient features.
The cabinet has no front door, but each subrack has independent open-close front
door. It provides the electro-magnetic compatibility (EMC) shielding at the subrack
level.
The cabinet leaves much space for routing and managing optical fibers.
Two movable side panels are installed at both sides of the cabinet. Each side panel
can move in or move out along the top and bottom slide rails. The fiber fender is
installed outside the side panel and can rotate round vertical axes.
Ventilation orifices are provided at the front door of the subrack and rear panel of
the cabinet to ensure heat dissipation.
The OptiX BWS 1600G adopts ETSI standard cabinet, which is in compliance with
Huawei Technologies Proprietary
2-1
2 Product Description
ETS300-119-3 standard.
For the structure of the cabinet, refer to OptiX BWS 1600G Backbone DWDM Optical
Transmission System Hardware Description Manual.
2.1.2 Specifications
Table 2-1 Specification of the cabinet
Item
Parameter
Dimensions
2000 W
2-2
2 Product Description
2.2 Subrack
2.2.1 Structure
The OptiX BWS 1600G subrack is divided into four areas: the upper part is interface
area accessing all kind of electrical signals. The middle part is board area to hold
DWDM boards and the lower part are fiber cabling area & fan tray assembly area. The
structure of the subrack is shown in Figure 2-1.
1. Interface area
4. Board area
7. Fan tray assembly
2. Air baffle
5. Fiber spool
8. Subrack front door
3. Air outlet
6. Fiber cabling area
9. Hook
Interface area
All external interfaces are located in this area, including the interfaces for subrack
power supply, NM and orderwire telephone, and so on.
The interface area also works as a heat dissipation outlet of the subrack. An air baffle
(a solid metal sheet) is placed at the top of subrack, guiding the airflow out of the front
of the subrack.
Board area
Totally 13 board slots are available, numbered IU1, IU2, IU3, , IU13 from left to
right when you face the front surface of the subrack. Slot IU7 is for SCC/SCE board
and is 24 mm wide. Other slots are 38 mm wide. All optical ports are located on these
front panels. Most optical ports are of LC/PC type while the LINE, EXT and OUT
optical ports on the front panel of the Raman amplifier unit and OUT port of the HBA
board are of E2000/APC type.
Huawei Technologies Proprietary
2-3
2 Product Description
All the optical fibers from the optical ports are routed to this area. These optical fibers
then come out of this area and reach the corresponding side of the subrack. There are
fiber spools at the two sides of the subrack, allowing good management over the
optical fibers.
Mechanical variable optical attenuator (VOA) is installed here.
This area contains fan tray and air filter. The air filter is fixed beneath the fan tray . The
fans and air filter ensure that the equipment works in dust-free and normal
temperature environment.
Front door
The front door is intended for equipment protection and electromagnetic compatibility
(EMC). The inner side of the front door is equipped with hooks to hold the screws for
adjusting the mechanical VOA.
Fiber spools
2.2.2 Specifications
Table 2-2 Specifications of the subrack
Item
Parameter
Dimensions
Weight
650 W
For details on the structure and interfaces of the subrack, refer to OptiX BWS 1600G
Backbone DWDM Optical Transmission System Hardware Description Manual
2-4
2 Product Description
Optical fiber automatic monitoring unit (optional, not depicted in Figure 2-2)
Figure 2-2 shows the positions of the boards in the system, illustrating only the
unidirectional signal flow.
2-5
1
OTU
40
1
OTU
client
side
40
C-EVEN
I
T
L
RPL
OAU
F
I
U
L-EVEN
OAU
MR2
MR2
MR2
F
I
U
OBU
C-band
M40
L-ODD
I
T
L
C-band
F
I
U
OAU
L-band
RPC
40
F
I
U
OAU
40
1
D40
OTM
OADM
2-6
OTU
D40
I
T
L
40
SC2/TC2
client
side
M40
SC1/TC1
OTU
D40
L-band
OAU
40
I
T
L
OAU
VOA
L-band
40
OTU
OTU
C-band
M40
OTU
D40
C-ODD
1
OTU
M40
SC1/TC1
OTM
OTU
40
2 Product Description
LWF: STM-64 Transmit-receive Line Wavelength Conversion Unit with FEC (Table
2-3)
LRF: STM-64 Line Regenerating Wavelength Conversion Unit with FEC (Table
2-3)
LWC1: STM-16 Line Wavelength Conversion Unit (compliant with G.709) (Table
2-4)
TRC1: STM-16 Optical Transmitting Regenerator with FEC (compliant with G.709)
(Table 2-4)
LWX: Arbitrary Bit Rate Wavelength Conversion Unit (34 Mbit/s to 2.5 Gbit/s)
(Table 2-4)
OCU: Quadruple STM-16 Multiplex Optical Wavelength Conversion Unit with FEC
(Table 2-5)
2-7
2 Product Description
The following table briefs the application and functions of the above boards. For board
principles and interface descriptions, refer to OptiX BWS 1600G Backbone DWDM
Optical Transmission System Hardware Description Manual.
Table 2-3 Application and description of wavelength conversion units (10 Gbit/s)
Board
name
Application
Function
Regenerating
board
LWF
LRF
LRFS
LRF
2-8
2 Product Description
Board
name
Application
Function
Regenerating
board
LRFS
Channel spacing: 50
GHz/100 GHz
LRFS
LRS
LRS
TMR
2-9
2 Product Description
Board
name
Application
Function
Regenerating
board
LBES
TMRS
Table 2-4 Application and description of wavelength conversion unit (2.5 bit/s or lower)
Board
name
Application
Functions
Regenerating
board
LWC
TRC
TRC
TRC
TRC1
2-10
TRC1
2 Product Description
Board
name
Application
Functions
Regenerating
board
LWM
LWM
LWX
TWC
TWC
Table 2-5 Application and description of convergent optical wavelength conversion unit
Board
name
Application
Functions
Regenerating
board
OCU
LRF
2-11
2 Product Description
Board
name
Application
Functions
Regenerating
board
OCUS
LRFS
TMR
TMRS
LQS
TWC
2-12
TWC
2 Product Description
Board
name
Application
Functions
Regenerating
board
LGS
TWC
EC8
TWC
TWC
Table 2-6 briefs the application and functions of the above boards. For board
Huawei Technologies Proprietary
2-13
2 Product Description
principles and interface descriptions, refer to OptiX BWS 1600G Backbone DWDM
Optical Transmission System Hardware Description Manual.
Table 2-6 Application and description of optical multiplexer/demultiplexer/add/drop multiplexer
Board
name
Application
Functions
M40
V40
FIU
2-14
2 Product Description
Board
name
Application
Functions
ITL
MR2
RPA: Raman Pump Amplifier Unit for C-band and L-band (Table 2-8)
Table 2-7 and Table 2-8 brief the application and functions of the erbium doped fiber
amplifier unit and the Raman amplifier unit. For board principles and interface
descriptions, refer to OptiX BWS 1600G Backbone DWDM Optical Transmission
System Hardware Description Manual.
2-15
2 Product Description
Board
name
Application
Functions
OAU
WBA
2-16
2 Product Description
Board
name
Application
Functions
RPC
RPA
Table 2-9 briefs the application and functions of the above boards. For board
principles and interface descriptions, refer to OptiX BWS 1600G Backbone DWDM
Optical Transmission System Hardware Description Manual.
2-17
2 Product Description
Table 2-9 Application and description of optical supervisory channel/timing transporting unit
Board
name
Application
Functions
SC1
TC1
Table 2-10 briefs the application and functions of the above boards. For board
principles and interface descriptions, refer to OptiX BWS 1600G Backbone DWDM
Optical Transmission System Hardware Description Manual.
2-18
2 Product Description
Table 2-10 Application and description of performance monitoring & adjustment unit
Board
and
module
name
Application
Functions
MCA
VA4
GFU
2-19
2 Product Description
The embedded OAMS is a relatively independent optional function, you can order it as
required in practice. The structure of an embedded OAMS system is shown in Figure
2-3.
DWDM node
DWDM node
MWF
MWA
DWDM node
MWF
FMU
Table 2-11 briefs the application and functions of the boards involved in the OAMS.
For board principles and interface descriptions, refer to OptiX BWS 1600G Backbone
DWDM Optical Transmission System Hardware Description Manual.
2-20
2 Product Description
Board
name
Application
Functions
FMU
Table 2-12 briefs the application and functions of the above boards. For board
principles and interface descriptions, refer to OptiX BWS 1600G Backbone DWDM
Optical Transmission System Hardware Description Manual.
2-21
2 Product Description
Board
name
Application
Functions
OLP
PBU
SCE: System Control & Communication Unit for Extended Subrack (Table 2-13)
Table 2-13 briefs the application and functions of the SCC and SCE. For board
principles and interface descriptions, refer to OptiX BWS 1600G Backbone DWDM
Optical Transmission System Hardware Description Manual.
2-22
2 Product Description
Board
name
Application
Functions
SCC
SCE
2-23
2 Product Description
Communication Module
Real-time
multi-task
operating
system
Equipment Management
Module
Database
management
module
Mailbox communication
Module
NE Software
Board Software
2-24
2 Product Description
network service (CLNS1) protocol stack. In addition, to support remote access of the
network management via modem, IP layer uses serial line internet protocol (SLIP)
protocol.
Complete protocol stack and messages of Q3/Qx interface are described in ITU-T
Recommendations G.773, Q.811 and Q.812.
2. Qecc Interface
Qecc interface utilizes the embedded control channel (ECC) to transmit the
information among NEs. In the system, data communication channel (DCC) in
supervisory channel is used as Qecc physical layer.
Qecc supports automatic route search and manual route table configuration. Normally
the automatic route search function is disabled by default to avoid network storm.
The protocol stack of Qecc interface is described in ITU-T Recommendation G.784.
3. F Interface
F interface adopts RS-232 standard and provides local craft terminal (LCT) access
capability. It is used for maintenance of local area network elements.
The accessing function of F interface is realized via serial port operation,
administration and maintenance (OAM) in the subrack.
NE software manages, monitors and controls the board operations in NE. It also
assists NM system to facilitate the centralized management over DWDM network.
According to ITU-T Recommendation M.3010, NE software is at unit management
layer in telecom management network, performing the functions: network element
function (NEF), partial mediation function (MF) and OS function at network unit layer.
data communication function (DCF) provides communication channel between NE
and other components (including NM and other NEs).
2-25
2 Product Description
Communication module
Huawei network management system OptiX iManager, not only provides DWDM
equipment management, but it also handles the entire OptiX family members
including SDH and Metro equipment. In compliance with ITU-T, it offers rich network
maintenance functions.
OptiX iManager series NM includes two parts: OS and WS (WorkStation). OS
includes configuration, fault, performance, security, topology, performance reports,
and system management. The management information is stored in database. OS
manages the NE or NE management system providing Q3 interface. OS can also
provide a management interface for upper-level management system. WS includes
configuration, fault, performance, security, topology, performance reports, system
management and on line help. WS display all the above information through
user-friendly graphic interfaces so that system handling becomes more convenient.
WS and OS exchange the data via F interface.
2-26
3 System Configuration
System Configuration
REG: Regenerator
3.1 OTM
3.1.1 Signal Flow
OTM is a terminating station of the DWDM network. An OTM is divided into the
transmitting end and the receiving end.
At the transmitting end, the OTM receives optical signals from multiple client
equipments (for example, SDH equipment), and converts these signals, multiplexes,
amplifies and sends them on a single optical fiber.
At the receiving end, the OTM demultiplexes the signals into individual channels and
distributes them to the corresponding client equipments.
An OTM consists of:
3-1
3 System Configuration
01
DCM
02
OD
OTU n
Client
side
OTU01
OTU02
OA
n
F
I
U
OSC/OTC
01
02
OA
OM
OTU n
RPU
n
DCM
MCA
At the transmitting end, up to 160 client-side signals are received at OTU boards,
where these received signals are converted into standard DWDM signals in
compliance with ITU-T Recommendation G.694.1.
The OM multiplexes these signals and sends them to the OA for amplification.
Meanwhile, the DCM implements dispersion compensation. Finally, the amplified
main path signal and supervisory signal are multiplexed, through the FIU, and sent to
the optical fiber for transmission.
At the receiving end, the RPU (optional), a low-noise pump amplifier, amplifies the
received main path signal. Then the main path signal is separated into supervisory
signal and service signal. After amplification and dispersion compensation, the
service signal is sent to the OD and demultiplexed by the OD. The supervisory signal
is directly processed by the OSC or OTC.
The OM, OD and OA provide optical performance monitoring port, through which the
MCA is accessed for monitoring central wavelength, optical power and OSNR of
multiple channels of optical signals.
3-2
3 System Configuration
The integrated OTM can work without OTU at the transmitting end, so 160 channels
of signals can be directly multiplexed into DWDM main optical path.
3.1.2 Structure
For the OTM of the six system types (refer to Chapter 1 Product Overview for
classification of system types), each functional unit and the board(s) contained are
shown in Table 3-1.
For the functions of these boards, refer to Chapter 2 Product Description.
3-3
3 System Configuration
Table 3-1 Functional units and the boards contained (six system types)
OTU
OM
OD
OA
RPU
OSC/OTC
FIU
M40+ITL,
V40+ITL
D40+ITL
RPA,
RPC+RPL
SC1, TC1
FIU-I, FIU-II
C + L 800 G
All OTUs
M40, V40
D40
RPA,
RPC+RPL
SC1, TC1
FIU-I, FIU-II
C 800G
M40+ITL,
V40+ITL
D40+ITL
RPC
SC1, TC1
FIU-III
III
All OTUs
M40, V40
D40
RPC
SC1, TC1
FIU-III
IV
M40, V40
D40
RPA
SC1, TC1
FIU-IV
M40, V40
D40
Unused
SC1, TC1
FIU-III
VI
All OTUs
M40, V40
D40
Transmitting end:
HBA, Receiving
end: OPU+OAU
RPC
SC1, TC1
FIU-III
System
Unit
II
3-4
3 System Configuration
1. Type I System
The type I system (1600G capacity) uses four 400 Gbit/s modules together, as
shown in Table 3-2, to access 160 channels.
Table 3-2 Distribution of 160 channels
Group
C-EVEN
192.10196.00
1529.161560.61
100
C-ODD
192.15196.05
L-EVEN
186.95190.85
L-ODD
187.00190.90
100
1570.421603.57
100
100
The structure of the OM, OD and OA of the type I system is shown in Figure 3-2.
Each of them has different specifications to process signals of different bands. For
example, M40 (C-ODD) multiplexes signals of C-ODD channels, M40 (C-EVEN)
multiplexes signals of C-EVEN channels.
OM & OD
OA
M40
C-ODD
M40
C-EVEN
OA-C
ITL-C
D40
C-ODD
OA-C
D40
C-EVEN
M40
L-ODD
OA-L
M40
L-EVEN
D40
L-ODD
ITL-L
OA-L
D40
L-EVEN
Figure 3-2 The structure of the OM, OD and OA of the type I system
The four 400 Gbit/s optical modules multiplex optical signals of each band and send
the multiplexed signal to the ITL-C and ITL-L, where the multiplexed signals are
multiplexed again into 80-channel multiplexed signal in C-band and 80-channel
Huawei Technologies Proprietary
3-5
3 System Configuration
multiplexed signal in L-band, with channel spacing of 50 GHz. After amplification and
dispersion compensation, the signals of two bands, together with optical supervisory
signal or optical supervisory signal & clock signal, are sent to the optical fiber for
transmission.
Note:
The channel spacing within each group is 100 GHz, that is the channel spacing at
each multiplexer/demultiplexer is 100 GHz. But the spacing between two adjacent
channels, for example channel 1 and channel 2, is 50 GHz. Therefore, the
interleaver can be used to realize 50 GHz channel spacing for the 1600G
transmission system.
For example, the frequencies of a multiplexed signal are 192.1 THz, 192.2
THz 196.0 THz, totally 40 channels, and those of another multiplexed signal are
192.15 THz, 192.25 THz 196.05 THz, totally 40 channels. After passing through
the interleaver, the output frequencies change to 192.1 THz, 192.15 THz, 192.2 THz,
192.25 THz, , 196.0 THz, 196.05 THZ, with channel spacing of 50 GHz. In this way,
the interleaver multiplexes/demultiplexes odd channels and even channels.
2. Type II System
C+L 800G
C 800G
The channel spacing of the C+L 800G system is 100 GHz, and that of the C 800G
system is 50 GHz. The structure of the OM, OD, and OA of the type II system is
similar to that of the type I system. The OM, OD and OA of the C+L 800G system
operate at C-EVEN and L-ODD bands, and those of the C 800G system operate at
C-EVEN and C-ODD, as shown in Figure 3-3.
3-6
3 System Configuration
OM
M40
C-EVEN
M40
L-ODD
D40
L-ODD
D40
C-EVEN
OA
OM & OD
OA-C
OA
M40
C-ODD
OA-L
OA-C
M40
C-EVEN
ITL-C
D40
C-ODD
OA-L
OA-C
D40
C-EVEN
OA-C
OD
Type II system
C 800G structure of OM, OD
and OA
Type II system
C+L 800G structure of OM,
OD and OA
The structure of the OM, OD, and OA of the type III, V, and VI systems is similar to
that of the type I system, operating at C-EVEN band only. The type IV system
operates at L-ODD band only.
The structure of the OM, OD and OA of the type III, IV, V, and VI systems is shown in
Figure 3-4.
OM
M40
C-EVEN
D40
C-EVEN
OA
OM
M40
L-ODD
OA-C
D40
L-ODD
OA-C
OD
OA
OA-L
OA-L
OD
OA
OM
M40
C-EVEN
HBA
D40
C-EVEN
OAU
OD
The structure of OM, OD, OA of
the type VI system
Figure 3-4 The structure of OM, OD, OA of the type III, IV, V and VI systems
3-7
3 System Configuration
In full configuration, an open OTM of the type I system needs six cabinets and 17
subracks, while an integrated OTM needs two cabinets and six subracks.
The configuration of OTM is based on the system capacity and upgrading mode.
Typically, the type I system adopts the smooth expansion by adding C-EVEN module,
C-ODD module, then L-EVEN module, and then L-ODD module. Each module has a
maximum capacity of 400 Gbit/s (40 channels) and smooth expansion from 1 to 40
channels can be enabled within each module.
Figure 3-5 shows the typical C-band 800 Gbit/s OTM configuration and Figure 3-6
shows the typical L-band 800 Gbit/s OTM configuration.
Power
Power
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(CO)
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(CE)
D
4
0
Power
D
4
0
O O O O
T T T T
U U U U
S
C
E
(CO)
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O OO O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
(CE)
O
A
U
M
C
A
I T S
T C C
L 1 C
(CG)
(C)
(C)
F
I
U
R
P
C
O
A
U
(CR)
DCM
HUB/1
HUB/1
C-EVEN OTU
C-ODD OTU
Note: All plug-in OTUs belong to C-band. HUB/1 indicates one 8-port HUB is configured in the HUB frame
Figure 3-5 Configuration of C-band 800 Gbit/s OTM (type I system)
3-8
3 System Configuration
Power
Power
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(LO)
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(LE)
D
4
0
Power
D
4
0
(LO)
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O OO O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
(LE)
O
A
U
M
C
A
(LG)
(L)
O O S O O I R
T T C T T T P
U U E U U L L
(L)
O
A
U
(LR)
DCM
HUB/2
HUB/1
L-EVEN OTU
L-ODD OTU
Note: All plug-in OTUs belong to L-band. HUB/1 indicates one 8-port HUB is configured in the HUB frame, and
HUB/2 indicates two 8-port HUBs are configured in the HUB frame.
Figure 3-6 Configuration of L-band 800 Gbit/s OTM (type I system)
Note:
If the system provides the line protection function, the OLP board needs to be
configured. In this case, the Raman amplifier unit cannot be used.
If OTUs need centralized power protection, a PBU board should be configured in slot
1 of the subrack holding OTU and all OTUs are placed in turn to right.
2. Type II System
3-9
3 System Configuration
Power
Power
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(CE)
D
4
0
Power
O OO O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
(CE)
O
A
U
M
C
A
(CG)
(C)
T S
C C
1 C
F
I
U
R
P
C
O
A
U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
(CR)
DCM
HUB/1
M
4
0
O
A
U
M
C
A
(LO)
(LG)
(L)
S
C
E
R
P
L
O
A
U
D
4
0
(LG)
(LO)
HUB/1
C-EVEN
L-ODD
Note: OTUs are either in C-EVEN or L-ODD band. HUB/1 indicates one 8-port HUB is configured in the
HUB frame.
Figure 3-7 Configuration of C+L 800 Gbit/s OTM (type II system)
If OTUs need centralized power protection, a PBU board should be configured in slot
1 of the subrack holding OTU.
C band OTM supports service expansion form one to 80 channels. The typical
configuration of C band 800G OTM is shown in Figure 3-8.
3-10
3 System Configuration
Power
Power
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(CO)
M
4
0
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
(CE)
D
4
0
Power
D
4
0
O O O O
T T T T
U U U U
S
C
E
(CO)
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
O OO O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
(CE)
O
A
U
M
C
A
I T S
T C C
L 1 C
(CG)
(C)
(C)
F
I
U
R
P
C
O
A
U
(CR)
DCM
HUB/1
HUB/1
C-EVEN OTU
C-ODD OTU
Figure 3-9 shows the configuration of OTM of the type III system (C-EVEN 400
Gbit/s).
The configuration of L-ODD 400G OTM of the type IV system is similar to that of the
type III system, except the boards are in L-ODD band.
The configuration of C-EVEN OTM of the type V system is similar to that of the type
III system, but the OTU it uses is no more than 2.5 Gbit/s and no DCM is needed.
If the system provides the line protection function, the OLP board needs to be
configured. In this case, the Raman amplifier unit cannot be used.
If OTUs need centralized power protection, a PBU board should be configured in slot
1 of the subrack holding OTU.
3-11
3 System Configuration
Power
Power
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
M
4
0
O
A
U
(C)
O O O O S O O O O
T T T T C T T T T
U U U U E U U U U
M
C
A
(C)
F T S
I C C
U 1 C
D
4
0
O O O O O O S O O
T T T T T T C T T
U U U U U U E U U
O
A
U
O O O O O O S O O O O O O
T T T T T T C T T T T T T
U U U U U U E U U U U U U
(C)
DCM
HUB/1
Note: All OTUs belong to C-EVEN band.
Figure 3-9 Configuration of 400 Gbit/s OTM (type III system)
4. Type VI System
Being an LHP, the type VI system provides 10-channel and 40-channel application,
which has similar configuration, except the number of OTU. Figure 3-10 shows the
configuration of the 10-channel system.
3-12
3 System Configuration
Power
P O O O
B T T T
U U U U
P
B
U
H
B
A
M
4
0
S
C
E
O O O S O O O O
T T T C T T T T
U U U E U U U U
M
C
A
(C)
F T S
I C C
U 1 C
O
A
U
(C)
D
4
0
O
A
U
(C)
DCM
HUB/1
Note: All OTUs belong to C-EVEN band.
Figure 3-10 Configuration of 10-channel OTM (type VI system)
The OTM of the type VI system is configured with a high booster amplifier (HBA) at
the transmitting end, and two optical amplifier units (OAU) at the receiving end.
In an open system, if the output power of the OTU boards is not adjustable, the
number of optical channels is more than 16, and there is a need for power
equalization, use V40. If the number of optical channels is less than 16, and there
is a need for power equalization, install one M40 along with several VA4.
In a hybrid system, if the output power of the OTU boards is not adjustable, the
number of optical channels is more than 16, and there is a need for power
equalization, M40 is replaced by V40 of corresponding band. If the number of
optical channels is less than 16, and there is a need for power equalization, install
one M40 along with several VA4.
3-13
3 System Configuration
2. Configuration of OTU
When installing OTU, first configure the C-EVEN module, and then C-ODD,
L-EVEN and L-ODD modules, from the bottom subrack to top subrack and left to
right in the subrack.
If the external clock is needed, the OCU boards are installed in the subrack from
right to left according to the sequence from big wavelength No. to small
wavelength No.. The preferred sequence of slots is: 12, 10, 8, 5, 3, 1.
3. Configuration of SCC/SCE
Amplifier units of the transmitting and receiving ends are installed at the leftmost
slots or rightmost slots.
If clock protection is required, install TC1/TC2 in both slot 6 and slot 8; otherwise
slot 6 is preferential.
In 1:8 OTU protection, all the boards in a protection group, including the working
OTU boards, the protection OTU, and the OCP should be installed in one
subrack. One subrack can accommodate one protection group only.
OLP is used for the purpose of optical line protection. It is not used with Raman
amplifier unit.
3-14
3 System Configuration
3.2 OLA
3.2.1 Signal Flow
The OLA amplifies bidirectional optical signals and compensates the dispersion to
extend the transmission distance without regeneration.
The OLA consists of:
C-band
OA-C
L-band
OA-L
RPU
DCM
FIU
OSC/OTC
FIU
DCM
C-band
L-band
OA-C
RPU
OA-L
DCM
At the receiving end, the RPU (optional), a low-noise pump amplifier, amplifies line
optical signals. The FIU separates the line optical signals into service signals and
supervisory signal.
Then all the service signals are sent to OA, where these signals are amplified
according to C-band and L-band. Meanwhile, DCM implements the dispersion
compensation to the service signals. Optical supervisory signals are sent to the OSC
Huawei Technologies Proprietary
3-15
3 System Configuration
3.2.2 Structure
For the OLA of the six system types, each functional unit and the board(s) contained
are shown in Table 3-3.
For the functions of these boards refer to Chapter 2 Product Description.
Table 3-3 Functional unit and the boards contained (five system types)
OA
RPU
OSC/OTC
FIU
RPA, RPC+RPL
SC1, TC1
FIU-I,
FIU-II
II
RPA, RPC+RPL
SC1, TC1
FIU-I,
FIU-II
II (C 800G)
RPC
SC2, TC2
FIU-III
III
RPC
SC2, TC2
FIU-III
IV
RPA
SC2, TC2
FIU-IV
Unused
SC2, TC2
FIU-III
System
Unit
The OLA equipment of the type I system adopts optical amplifier of C-band and
L-band for amplifying service signals of C-band and L-band respectively.
The C+L 800G OLA of the type II system adopts optical amplifier of C-band and
L-band for amplifying service signals of C-band and L-band respectively. The c
band 800G OLA adopts optical amplifier of C-band for amplifying service signals
of C-band.
The OLA equipment of the type III and V system adopts optical amplifier of
C-band for amplifying service signal of C-band.
The OLA equipment of the type IV system adopts optical amplifier of L-band for
amplifying service signal of L-band.
The type VI system is long hop system with no need for the OLA equipment.
3-16
3 System Configuration
The OLA equipment achieves the bidirectional main path optical signal amplification
in C-band and L-band. In each direction, two optical amplifiers are needed, which
amplify optical signals in C-band and L-band respectively. The configuration is shown
in Figure 3-12.
Note:
In DWDM equipment, the definition about west and east is:
1. In chain network left is west and right is east.
2. In ring network, the counter-clockwise (outer ring) is the primary ring, with the
direction from west to east.
west
west
east
east
west
east
east
west
west
east
3-17
3 System Configuration
Power
from west
to east
O
A
U
(C)
O
A
U
(L)
F T S
I C C
U 2 C
F
I
U
O
A
U
(L)
O
A
U
(C)
from east
to west
east
west
DCM
If the system needs a Raman amplifier unit, configure two RPA boards in the new
middle subrack; if the system needs to configure the optical line protection, configure
two OLP boards in the new middle subrack. Note that RPA and OLP can not be
configured at the same time.
2. Type II System
The OLA equipment achieves the bidirectional main path optical signal amplification
in C-band; each direction needs one optical amplifier. The configuration is shown in
Figure 3-13.
3-18
3 System Configuration
Power
from west
to east
O
A
U
(C)
O F T S
L I C C
P U 2 C
F O
I L
U P
O
A
U
(C)
from east
to west
east
west
DCM
The case shown in Figure 3-13 is configured with optical line protection, which can
be disabled by removing the OLP board. If the system needs a Raman amplifier unit,
configure two RPC boards in the lower subrack. Note that the Raman amplification
function and line protection function are exclusive.
Usually, the type V system does not need the DCM unit.
4. Type IV System
The configuration of the type IV system is similar to that of the type III system, except
that the OA units of the type IV system are used in L-band.
If OAU, OBU and Raman amplifier unit are to be configured from west to east,
install them at the left side (slot 1 or 3) of the subrack. If they are to be configured
from east to west, install them at the right side (slot 12 or 10) of the subrack.
If the power budget of the system is not adequate, OBU can be used besides
Huawei Technologies Proprietary
3-19
3 System Configuration
OAU. Install OBU in slot 3 (from west to east) or slot 10 (from east to west).
OBU is preferential than Raman amplifier unit in installing in the slots above
mentioned. Raman amplifier units can also be installed in other idle slots.
2. Configuration of SCC/SCE
If clock transmission is required, use TC2; otherwise use SC2. Note that TC2
cannot be used together with SC2.
If clock protection is required, install TC2 in both slot 6 and slot 8; otherwise slot 6
is preferential.
OLP is used for the purpose of optical line protection, but not used with Raman
amplifier unit.
3-20
3 System Configuration
3.3 OADM
3.3.1 Signal Flow
OADM is used to add/drop channels to/from the main path locally while passing
other channels transparently.
The OptiX BWS 1600G has two types of OADM equipment: serial OADM and
parallel OADM. Serial OADM can be configured by concatenating MR2 boards,
while parallel OADM is formed by back-to-back OTMs.
1. Serial OADM
It consists of:
3-21
3 System Configuration
OTU
1
OTU
2
n-1
OA
OA
C-band
F
I
U
OADM unit
OA
L-band
C-band
OA
F
I
U
L-band
OA
OA
OSC/OTC
MCA
The OADM unit in Figure 3-14 is formed by MB2 or MR2, and can support full
add/drop at C-band.
At the receiving end, the RPU (optional), a low-noise pump amplifier, amplifies line
optical signals. The FIU demultiplexes the line optical signals into service signals and
supervisory signal.
The supervisory signal is sent to the OSC or OTC for processing. The C-band
service signals are added/dropped some channels in the OADM. Note that the
service signals may need to be amplified before they enter or after they go out of the
OADM unit. The L-band service signals are also amplified through the OA. Finally,
C-band and L-band service signals are combined with supervisory signal and sent to
the optical fiber.
2. Parallel OADM
It consists of:
3-22
3 System Configuration
Figure 3-15 shows the signal flow of parallel OADM (the 40-channel system is taken
as an example)
OSC/OTC
P
P
1~40
IN
OA
OD
F
I
U
OM
1~40
OA
F
I
U
IN
OUT
OUT
P
1~40
OA
OM
P
A
A
D
D
O
T
U
P: Pass-through channel
O
T
U
A: Added channel
O
T
U
OD
O
T
U
OA
1~40
MCA
D: Dropped channel
The parallel OADM is formed by back-to-back OTMs. The parallel OADM can
add/drop channels through the OD (D40) and the OM (M40) while regenerating or
passing through other channels.
When more than 32 add/drop channels are required in one station, the parallel
OADM is usually used. And it can be upgraded to 160 channels as needed.
3.3.2 Structure
The parallel OADMs of the five system types (type I to type V) are constructed in the
similar way. Here only serial OADM is introduced.
For the serial OADM of the five system types, each functional unit and the board(s)
contained are shown in Table 3-4.
For the functions of these boards, refer to Chapter 2 Product Description.
3-23
3 System Configuration
Table 3-4 Functional units and the boards contained (five system types)
System
Unit
II (C+L 800G)
OTU
OADM
OA
RPU
OSC/OTC
FIU
ITL+MR2,
ITL+MB2,
OAU, OBU,
OPU
RPA,
SC1, TC1
FIU-I,
FIU-II
All OTUs
MR2, MB2
OAU, OBU,
OPU
RPA,
SC1, TC1
FIU-I,
FIU-II
RPC+RPL
RPC+RPL
II (C 800G)
ITL+MR2,
ITL+MB2
OAU, OBU,
OPU
RPC
SC2, TC2
FIU-III
III
All OTUs
MR2, MB2
OAU, OBU,
OPU, WBA
RPC
SC1, TC1
FIU-III
IV
MR2, MB2
OAU, OBU,
OPU
RPA
SC1, TC1
FIU-V
LWC, TRC,
LWC1, TRC1,
LDG, LWM, LWX,
LQS, LGS, TWC,
AP4, EC8
MR2, MB2
OAU, OBU,
OPU, WBA
Unused
SC1, TC1
FIU-III
1. Type I System
The structure of the serial OADM of the type I system is shown in Figure 3-16.
3-24
3 System Configuration
OADM unit
1
C-ODD
OADM
board
I
T
L
OADM
board
C-ODD
I
T
L
C-EVEN
OADM
board
OADM
board
C-EVEN
In Figure 3-16, the OADM includes the ITL, which divides the service signals into
odd channels and even channels. Up to 16 odd channels and 16 even channels can
be added/dropped in C band, so the OADM can add/drop up to 32 channels locally.
2. Type II System
C-ODD
C-EVEN
OADM
OADM
OADM
OADM
C-EVEN
C-ODD
I
T
L
L-ODD
OADM
OADM
I
T
L
C-EVEN
OADM
OADM
C-EVEN
L-ODD
Tpe II system
C 800G
Type II system
C+L 800G
The OADM of the type III system does not include the ITL. It can support full
add/drop by cascading OADMs, as shown in Figure 3-18.
3-25
3 System Configuration
OADM in type III system
1
C-EVEN
OADM
board
OADM
board
C-EVEN
The OADM of the type IV and V systems does not include the ITL either. They
add/drop up to 16 channels by cascading MR2 boards.
Power
M M O O O O S M M O O O O
B R T T T T C B R T T T T
2 2 U U U U E 2 2 U U U U
M M O O O O S M M O O O O
B R T T T T C B R T T T T
2 2 U U U U E 2 2 U U U U
from west
to east
O
A
U
(C)
O
B
U
(C)
F T S
I C C
U 2 C
F
I
U
O
B
U
(C)
west
subrack
east
subrack
O
A
U
(C)
from east
to west
east
west
DCM
HUB
Figure 3-19 Configuration of C-band serial OADM equipment (type III system)
3-26
3 System Configuration
If the system needs the Raman amplifier unit, RPU is installed in the new subrack; if
the system needs the optical line protection, two OLP boards are installed in the new
subrack and cabinet.
If OTUs need centralized power protection, a PBU board should be configured in slot
1 of each subrack holding OTU. And all OTU boards are placed in turn to right after
the PBU.
The configurations of OADM of other systems are similar to that of the type III
system. For the type I system, the ITL board and L-band OAU should be added;
For the type II system, the L-band OAU should be added for C+L 800G and the ITL
board added for C 800G;
For the type IV system, the L-band OAU and OADM unit should be added;
For the type V system, DCM is not needed.
2. Parallel OADM
3-27
3 System Configuration
Power
P O O
B T T
U U U
Power
V
A
4
S
C
E
P O O O O O S O O O
B T T T T T C T T T
U U U U U U E U U U
M
4
0
O
A
U
(C)
F T S
I C C
U 2 C
M
C
A
O
A
U
V V
A A
4 4
D
4
0
P O O
B T T
U U U
P O O O O O S O O O
B T T T T T C T T T
U U U U U U E U U U
M
4
0
(C)
V
A
4
S
C
E
O
A
U
(C)
DCM
HUB/1
F T S
I C C
U 2 C
O
A
U
V V
A A
4 4
D
4
0
(C)
DCM
HUB/1
East cabinet
West cabinet
Figure 3-20 Configuration of C-band parallel OADM equipment (type III system)
C or L below the OAU, OBU, MCA, and ITL indicates their working bands.
If OAU, OBU, Raman amplifier unit and ITL are to be configured from west to
east, install them at the left side of the subrack. If they are to be configured from
east to west, install them at the right side of the subrack.
2. Configuration of OTU
When installing OUT, first configure the C-EVEN module, and then C-ODD
module.
If the number of MR2 boards exceeds 4, east MR2 boards are installed in one
subrack and west MR2 boards in another. If the number is no more than 4, east
MR2 boards are installed in right slots and west MR2 boards in left slots of the
Huawei Technologies Proprietary
3-28
3 System Configuration
same subrack.
If the external clock is needed, the OCU boards are installed in the subrack from
right to left according to the sequence from big wavelength No. to small
wavelength No.. The preferential sequence of slots is: 12, 10, 8, 5, 3, 1.
3. Configuration of SCC/SCE
If clock transmission is required, use TC2; otherwise use SC2. Note that TC2
cannot be used together with SC2.
If clock protection is required, install TC2 in both slot 6 and slot 8; otherwise slot 6
is preferential.
OLP is used for the purpose of optical line protection. It is exclusive with Raman
amplifier unit in the configuration.
3-29
3 System Configuration
3.4 REG
3.4.1 Signal Flow
We have already discussed that OLA can extend the optical transmission distance
without regeneration. However, when the distance is longer, such factors as
dispersion, power loss, optical noise, non-linear effect, or PMD will affect the
transmission performance. In this case, we need to regenerate the original signals. A
REG accomplishes the 3R function, i.e. reshaping, re-timing and regenerating to
improve signal quality and extend the transmission distance.
An REG station contains:
OTU01
OTU02
OA
01
OM
OD
OTU n
F
I
U
DCM
02
OA
n
F
I
U
OSC/OTC
OTU01
OTU02
OA
01
02
OM
OD
DCM
OTU n
OA
n
DCM
MCA
The signal flow of the REG is similar to that of back-to-back OTMs, except that no
signal is added/dropped. Signals are regenerated through regenerating OTU.
3-30
3 System Configuration
3.4.2 Structure
For the REG of the six system types, each functional unit and the board(s) contained
are shown in Table 3-1.
The structure of OM, OD, and OA of the six system types is the same with that of the
OTM equipment, as shown in Figure 3-2 and Figure 3-3.
The configuration of REG of 20-channel application in type III system is the same as
that shown in Figure 3-20.
3-31
3 System Configuration
3.5 OEQ
3.5.1 Signal Flow
In the extra long haul (ELH) application, as the transmission distance without
regenerator is much longer than that in the long haul application, the following
problems may occur.
The dispersion slope of DCM does not match with optical fibers completely, so all
wavelengths cannot be compensated completely, and the dispersion at the
receiving end fails to meet the requirement of the system.
To better realize optical power equalization and dispersion compensation, the OEQ
is used in the ELH application. Currently, the type II and II systems can realize ELH
transmission.
The OEQ equipment consists of optical power equalizer and dispersion equalizer.
(1) Optical power equalizer
It consists of:
3-32
3 System Configuration
OA
F
I
U
OPE
OA
F
I
U
OSC/OTC
OA
OA
OPE
MCA
OA
F
I
U
DE
OA
F
I
U
OSC/OTC
OA
OA
DE
MCA
The dispersion equalizer and the optical power equalizer can be placed in the same
station.
The dispersion equalizer is often placed at the receiving end of the OTM for
Huawei Technologies Proprietary
3-33
3 System Configuration
OTU01
OTU02
DE
01
02
OD
OTU n
Client
side
OTU01
OTU02
OA
n
F
I
U
OSC/OTC
01
02
OA
OM
OTU n
RPU
n
DCM
MCA
3.5.2 Structure
Two solutions are available: use of dynamic gain equalizer unit (DGE) and use of
VMUX unit, as shown in Figure 3-25 and Figure 3-26.
OAU
F
I
U
DGE+DCM
OAU
C-EVEN
DCM+DGE
F
I
U
C-EVEN
SC2/TC2
MCA-C
In Figure 3-25, the optical power equalizer unit consists of DGE and DCM. The DGE
realizes optical power equilibrium of each channel by adjusting insertion loss
spectrum of the DGE board. DCM is used to realize dispersion compensation of the
system.
This solution has all the functions of OLA. In addition, optical power equilibrium is
Huawei Technologies Proprietary
3-34
3 System Configuration
implemented to make the multiplexed signals meet the requirement for optical power
flatness, and to extend transmission distance without regeneration.
Note:
For DGE solution, note whether the power margin of OAU meets the insertion loss
requirement of DCM and DGE. If the margin cannot meet the requirement,
OAU+OBU should be adopted. DCM and DGE are placed between two amplifiers.
OAU
C-EVEN
F
I
U
OBU
V40
D40
F
I
U
SC2
OBU
V40
D40
C-EVEN
OAU
Figure 3-26 Optical power equalization through the VMUX (the V40 board)
In Figure 3-26, VMUX is adopted. V40 is used as the VMUX unit to adjust optical
power of each channel, so as to equalize optical power.
The user can select one of the solutions according to the actual requirement.
Dispersion equalizer
3-35
3 System Configuration
DCM
OBU
DSE
OAU
F
I
U
F
I
U
SC2
OBU
DSE
OAU
DCM
Through the dispersion slope equalizer (DSE), the system sends the multiplexed
signals to the DCM for equalized compensation of dispersion.
Note:
In ultra-long haul transmission, the configuration of optical equalizer should follow the
principles below.
1. When 8number of optical amplification sections12, and without configuration
of OEQ, the VMUX should be configured at the transmitting end for equalization.
2. When number of optical amplification sections12, the OEQ should be
configured. The subsequent optical amplification sections will be configured
differently according to OEQ solution.
a. D40+V40 solution: An OEQ is added when 8 optical amplification sections are
added.
b. DGE solution: An OEQ is added when 5 optical amplification sections are
added.
If the optical fiber length of multiplexing section is equal to or greater than 1000km,
dispersion equalizer is required.
3-36
3 System Configuration
Power
Power
M
C
A
(C)
O
A
U
D
G
E
V
4
0
D
4
0
M
C
A
(C)
O
A
U
O
A
U
O
B
U
F T S
I C C
U 2 C
(C)
(C)
(C)
S
C
E
F T S
I C C
U 2 C
F
I
U
D
G
E
(C)
S
C
E
F
I
U
D
4
0
V
4
0
O
B
U
O
A
U
(C)
(C)
DCM
HUB
DCM
HUB
Solution 2: V40+D40
Solution 1: DGE
3-37
3 System Configuration
Power
F
I
U
O
A
U
(C)
O
B
U
(C)
S
C
E
F
I
U
M
C
A
(C)
D T S
S C C
E 2 C
D
S
E
O
B
U
(C)
O
A
U
(C)
DCM
HUB
Figure 3-29 Configuration of dispersion equalizer
3-38
Client
OLA
(2)
OLA
(n-1)
OTM
OTM
1160
Client
1160
mdB
nm dB
Point-to-point network
ADD
Client
OTM
OLA
OADM
OLA
OEQ
REG
1160
OTM
Client
1160
DROP
Chain network
160
Back-to-back
OTM
1
OADM
OADM
80
80
Back-to-back
OTM
160
Ring network
Point-to-point
The point-to-point network, composed of OTM and OLA, is the most prevalent
networking mode adopted by the OptiX BWS 1600G.
Chain
The chain network is frequently used in national DWDM backbone network that is of
high capacity and long distance. A chain network may comprise of OTM, OLA, OADM,
REG and OEQ, and can be regarded as the extension of point-to-point network.
Ring
The ring network is largely used in regional network. It may comprise of OADMs or
back-to-back OTMs depending on the practical situation. In practice, one OADM in the
DWDM ring network may be composed of back-to-back OTMs to eliminate the
accumulated noise caused by the amplifier.
Classification
Specification
Typical distance
With FEC
1 28 dB
2 24 dB
2 87 km (174 km)
5 20 dB
5 72 km (360 km)
With FEC
1 34 dB
With Raman
amplification
5 25 dB
5 90 km (450 km)
8 22 dB
8 80 km (640 km)
The span attenuation is the actual attenuation of fibers, not including the loss of any optical
components.
Note:
In section 4.1 , the span attenuation is the actual attenuation of the fiber, that is, the
difference between the output optical power of local station and input optical power of
the downstream station, not including the attenuation of FIU board.
In section 4.1 , the typical distances in the networking specification are calculated on
condition that the fiber attenuation coefficient is 0.275 dB/km.
The Raman amplifier can suppress OSNR from deteriorating to support more spans,
and to transmit signals longer. With Raman amplification, the type I system supports a
transmission distance of 640 km without a regenerator.
If the type I system uses out-band EFEC, it can support longer transmission without
REG.
The C+L 800G system, adopting NRZ encoding, is applied in G.652/G.655 optical fiber.
Table 4-2 shows its networking capability.
Classification
Specification
Typical distance
With FEC
1 32 dB
Without Raman
amplification
4 25 dB
4 90 km (360 km)
7 22 dB
7 80 km (560 km)
With FEC
7 27 dB
With Raman
amplification
18 22 dB
18 80 km (1440 km)
If the system adopts the Raman amplifier, the noise of signals is greatly reduced, thus
realizing long-haul transmission without REG.
The SuperWDM technology (CRZ encoding) can effectively suppress non-linearity in
the system, increase the tolerance to OSNR, to realize over 1000 km transmission
without REG and Raman amplifier. Its networking capability is shown in Table 4-3
Table 4-3 Networking capability of type II system (C+L 80-channel, SuperWDM)
Classification
Specification
Typical distance
With FEC
5 27 dB
With CRZ
14 22 dB (12 22 dB)
(Note1 )
Note 1: The data in bracket is obtained on condition that (an) OEQ being used.
2. C 800G
The C 800G system, adopting NRZ encoding and CRZ encoding (SuperWDM
technology), supports G.652 and G.655 fibers. Table 4-4 shows its networking
capability.
Table 4-4 Networking capability of type II system (C, 80-channel)
Classification
Specification
Typical distance
1 32 dB
5 25 dB
5 90 km (450 km)
8 22 dB
8 80 km (640 km)
1 36 dB
7 25 dB
7 90 km (630 km)
12 22 dB
12 80 km (960 km)
Specification
Typical distance
1 30 dB
3 25 dB
3 90 km (270 km)
6 22 dB
6 80 km (480 km)
1 32 dB
6 25 dB
6 90 km (540 km)
10 22 dB
10 80 km (800 km)
Classification
Specification
Typical distance
With FEC
1 34 dB
Without Raman
amplification
5 27 dB
5 98 km (490 km)
10 22 dB
10 80 km (800 km)
Table 4-6 shows its networking capability when the system adopts SuperWDM
technology (CRZ encoding) and is applied in G.652 optical fiber.
Table 4-6 Networking capability of type III system (40-channel, SuperWDM)
Classification
Specification
Typical distance
With FEC
10 27 dB
10 98 km (980 km)
Without Raman
25 22 dB
25 80 km (2000 km)
Table 4-7 Networking capability of type III system (G.653 optical fiber)
Classification
Specification
Typical distance
With FEC
1 32 dB
12-wavelength system
3 27 dB
3 98 km (294 km)
6 23 dB
6 83 km (498 km)
With FEC
1 33 dB
8-wavelength system
3 28 dB
8 20 dB
8 70 km (560 km)
Classification
Specification
Typical distance
With FEC
1 30 dB
3 25 dB
3 90 km (270 km)
5 22 dB
5 80 km (400 km)
If the system adopts the Raman amplifier, the noise will be greatly reduced, thus
realizing longer transmission without a regenerator.
Classification
Specification
Typical distance
With FEC
1 39 dB
6 27 dB
6 98 km (588 km)
8 22 dB
8 80 km (640 km)
Type V system can realize transmission of 640 km without using the REG and any
dispersion compensation component. Generally, the type V system does not need
Raman amplification.
Huawei Technologies Proprietary
4-6
Application
10-wavelength
40-wavelength
10-wavelength
40-wavelength
OSNR requirement
20 dB
18 dB
20 dB
18 dB
15 dB
15 dB
HBA + FEC
44 dB
47 dB
38 dB
41 dB
51 dB
46 dB
HBA + FEC +
Raman
50 dB
53 dB
43 dB
46 dB
56 dB
49 dB
Classification
Note: The OSNR in the table is the requirement at the point MPI-R.
The LHP system is point-to-point OTM configuration without any optical or electrical
regeneration.
If the SuperWDM is used, the transmission distance can be extended.
OAU
OAU
Normal output
Attenuated output
Attenuated input
OAU
OAU
Normal output
Normal input
Attenuated input
In normal working, two elements might cause the input power change in the optical
amplifier:
In order not to affect the normal working of other channels, the system should quickly
respond to the change. The system works in the gain control mode.
ALC determine the adjustment of the variable optical attenuator according to the
channel amount and output power. The redundancy design of the system permits the
abnormal line attenuation adjustment. If the attenuation is within the limit, the
adjustment process will take several minutes. It will ensure the normal working of the
system.
ALC is realized through channel amount detection and reference power.
1. Channel Amount Detection
Prerequisite: The output optical power of the first node on the ALC link is taken as
reference value.
Realization: The optical amplifier works in AGC mode, by activating the detection of
the output optical power of the optical amplifier at the first node to determine further
actions. Compare the detecting result with the information reported before the ALC
command is trigged. If consistent, deliver the ALC adjustment command formally to
adjust attenuation, thus keeping the output optical power stable (the power of a single
channel remains unchanged).
Note:
In the DWDM system, the IPA function is started only when optical signals of the active
optical path are lost. When this function is executed, you can monitor optical power
and shut down the lasers on the main path only. No operation will be implemented on
the optical supervisory channel. Hence the functions of all optical supervisory
channels will not be affected.
O
T
U
OAU
V
4
0
M
C
A
SC1
Adjustment station
Monitoring station
The normal functioning of APE requires the coordination between the optical boards
and the SCC board, and the participation of the user. As shown in Figure 4-4, for
power equilibrium, each channel power at the transmitting end can be adjusted
according to the per channel power measured by the MCA at the receiving end. The
APE brings convenience to DWDM system test in deployment and subsequent
network maintenance. The APE function mode can also be set allowing user to decide
whether to adjust the optical power.
Configuration principle:
To implement the APE function, it is required that the OTM station at the
transmitting end should be configured with V40, and the OTM station at the
receiving end should be configured with MCA. Moreover, since DWDM is a
dual-fiber bidirectional system, an MCA should be configured at the both ends
of a multiplexing section.
To implement the APE function, it is required to install MCA and OSC unit
(SC1/SC2/TC1/TC2) in one subrack. If not, network port ETHERNET 2 of two
subracks should be interconnected.
To implement the APE function, it is required to install V40 and OSC unit
(SC1/SC2/TC1/TC2) in one subrack. If not, network port ETHERNET 2 of two
subracks should be interconnected.
Note:
1. Here we define an adjustment station where optical power is adjusted and a
monitoring station where optical power is measured by the MCA.
2. To start the APE function, the V40 of the adjustment station and one of optical
interfaces of the MCA of the monitoring station should be first configured as an APE
function pair, and enable APE function.
3. There is a dedicated APE protocol byte in the overhead frame of the supervisory
signal, which is used for transmitting APE related information.
4. Since an OADM station may exist between adjustment station and monitoring
station, all the wavelengths detected in monitoring station may not be adjusted by V40
in the adjustment station. As a result, the wavelengths with APE function activated
should be specified by NM.
CLK
Optical
amplifier-1
Optical
amplifier-2
CLK
West
Terminal-A
East
CLK
West
CLK
Terminal-B
East
CLK
CLK
In the OptiX BWS 1600G system, clock transmission can be set to protection mode or
non-protection mode. In clock protection mode, two carrier wavelengths are used,
with 1510 nm for normal channel and 1625 nm for protected channel.
A summary of clock transmission is given below.
In the case that there is clock being added/dropped at intermediate station, the
intermediate station supports at most 3 clock channels in clock non-protection
mode. The 3 clock channels may come from both East and West directions.
In the case that there is clock being added/dropped at intermediate station, the
intermediate station supports at most 3 clock channels in clock non-protection
mode. The 3 clock channels must come from one direction (East or West).
On-line (light fiber) monitoring: To monitor and test a working optical fiber (cable). In
this case, the wavelength of test signal is 1310 nm.
Standby fiber (dark fiber) monitoring: To monitor and test a standby optical fiber (cable).
In this case, the wavelength of test signal is 1550 nm.
Unidirectional test: To monitor and test a span with unidirectional test signal.
In this case, two adjacent spans share an independent remote test unit (RTU), so the
RTU number is greatly reduced and OAMS cost decreases accordingly.
DWDM node
DWDM node
DWDM node
DWDM node
OAMS
RTU
RTU
Service signal
Test signal
DWDM node
Due to the limitation of dynamic test range of the built-in optical time domain
reflectometer (OTDR), the unidirectional test fails when measuring a long span of
much attenuation. Here the monitoring and test can be implemented from both ends
of the span by two OTDR modules.
Bidirectional test: To monitor and test a span with bidirectional test signals.
DWDM node
DWDM node
RTU
RTU
DWDM node
RTU
DWDM node
DWDM node
RTU
RTU
OAMS
Test signal
Service signal
In the bidirectional test, configure a RTU module at each end of a span, and the two
RTUs will report their test results to NM for combination, and then the performance
parameter of this span will be obtained by analyzing and processing the test results.
2. System Architecture
The OAMS structure of online monitoring differs with that of standby fiber monitoring.
Online monitoring
The RTU shown in Figure 4-6 and Figure 4-7 consists of three boards and their
functions are listed in Table 4-11.
Board
Name
Function
FMU
MWA
MWF
The embedded OAMS system comprises of FMU, MWA and MWF, as shown in
Figure 4-8.
DWDM
DWDM
MWF
DWDM
MWA
OAMS
MWF
FMU
In the Figure 4-8, the DWDM node can be OTM, OLA, OADM, OEQ or REG. The
OTDR module in FMU emits the optical test pulse, and receives, collects, processes
and reports the reflection signal, thus monitoring the running status of the fiber in real
time. FMU can monitor at most four lines of optical fibers.
The coupler on MWA multiplexes the service signal and test signal in one fiber for
transmission. When the test signal and service signal are transmitted in the same
direction, the filter on MWF can filter the test signal at the receiving node to eliminate
the effect to the system.
The structure and configuration of OAMS vary with network specifications. The figure
here only shows the OAMS of unidirectional test.
DWDM node
DWDM node
F
M
U
Standby
fiber
Standby
fiber
The performance monitoring and test to the standby fiber can be achieved by using
FMU board, NE software and NM. The structure and configuration of OAMS vary with
network specifications. Figure 4-9 only shows the OAMS of unidirectional test.
3. Configuration Plan
The Raman amplification and optical fiber attenuation will affect the embedded OAMS
to some extent, Table 4-12 lists the OAMS applications with and without Raman
amplification.
Table 4-12 Applications of embedded OAMS
System type
Fiber attenuation
Supported monitoring
With Raman
amplification
--
Without Raman
amplification
45 dB
>45 dB
Note: The 1310nm test signal is of great attenuation in fiber, resulting in limited monitoring distance,
so the spans more than 45dB are only provided with standby fiber monitoring.
Table 4-13 lists the configuration of OAMS in various system specifications of the
OptiX BWS 1600G under different monitoring modes.
Monitoring
mode
System
specification
Span
attenuation
(dB)
Monitoring
signal
wavelength
(nm)
OTDR
dynamic
test range
(dB)
Optical
fiber
lengthNote
1 (km)
Test mode
Online
monitoring
Long
distance
transmission
22
1310
42
80
Unidirectional
test
28
42
100
Time-shared
bidirectional
test
33
42
120
Time-shared
bidirectional
test
LHP
3845
42
138163
Time-shared
bidirectional
test
Long
distance
transmission
22
40
80
Unidirectional
test
28
40
100
Unidirectional
test
33
40
120
Time-shared
bidirectional
test
3845
40
138163
Time-shared
bidirectional
test
4556
40
163200
Time-shared
bidirectional
test
Standby fiber
monitoring
LHP
1550
Note: The optical fiber length is calculated on condition that the attenuation coefficient is 0.275 dB/km.
4. System Function
Query the input and output optical power of the optical fiber link between nodes, that is,
the output optical power of one station and the input optical power of the next station.
Obtain the attenuation over the link between two adjacent nodes through the NM and
compare the result with the pre-set data. Take the difference of the optical power as
the trigger to enable the test. When the difference exceeds the pre-set value or the
threshold set by the user through NM, the OAMS will be enabled to test the
performance of optical fiber link.
The system provides two ways to test fibers according to the priority.
Huawei Technologies Proprietary
4-16
On-demand test: Generate through NM manually, select and control a RTU to test a
certain fiber in the monitored optical fiber line.
Periodical test: Conventional test, namely the test is started upon the previously
arranged conditions are satisfied. The equipment will report the result as an event to
NM after the test.
The test requirement of higher priority can stop that of lower priority to start a new test
queue.
Besides the test function, the OAMS system also provides analysis of the test result
and then reports the corresponding test curve and event list to NM.
Fiber alarm
The equipment reports alarms depending on the analysis of the test curve. The alarms
fall into three levels.
Critical alarm: Burst of event over 5 dB, including fiber break. The terminal shows red
and gives audible and visible prompt.
Major alarm: The difference between the attenuation of the whole path and the
acceptance value (or original data) is no less than 3 dB; or the attenuation increase
event (new or not) is no less than 2 dB. The terminal shows pink and gives visible
prompt.
Minor alarm: The difference between the attenuation of the whole path and the
acceptance value (or original data) is no less than 1 dB, while less than 3 dB; or the
attenuation increase event (new or not) is no less than 1 dB. This alarm will be report
to NM and recorded as an exception for future query, but will not give prompt.
Note:
Event: The event in OAMS refers to the physical circumstances showing the status of
the optical fiber line during OTDR test. It comprises reflection event and non-reflection
event. The fiber reflection events include connector, mechanical connection point and
optical fiber end, and so on. While the non-reflection events include optical fiber fusion
point, fiber break, bending or macrobend.
5 Protection
Protection
When detecting the secondary power of the OTU fails (under-voltage), the system
switches to the PBU for power supply in 600s. The PBU can supply power for two
OTUs simultaneously.
The PBU is inserted in slot 1, providing power backup for all OTUs in the subrack, as
shown in Figure 5-1.
5-1
5 Protection
Secondary power backup
P
B
U
O O O O O
T T T T T
U U U U U
S
C
E
O
T
U
O O
T T
U U
O
T
U
O O
T T
U U
Currently, the OTUs supporting PBU centralized protection include LWF, LWFS, LRF,
LRFS, OCU, OCUS, TMX, TMXS, LWS, LBE, LBES, TMR, TMRS, LDG, LWC, LWC1,
TRC1, AP4, EC8 and TRC.
5-2
5 Protection
O
T
M
Station C
Station B
O
L
P
O
L
P
Protected path
O
L
A
or
O
A
D
M
Working path
O
L
P
O
L
P
O
T
M
Protectected path
As shown in the Figure 5-2, two optical fibers in one optical cable are used as a
bidirectional working path, and other two optical fibers from the second optical cable
are used as the protected path. Normally, the working path carries information traffic.
In case of any abnormality in the working path, for example, the working optical cable
is broken or the performance becomes deteriorated, the traffic will automatically
switch to the protected path through the OLP. Moreover, the protection path is
monitored in real-time. When any problem occurs to the protected path, the
equipment can detect the fault and handle it in time.
Therefore, the DWDM equipment protects the transmission line on the optical layer
level, with the help of OLP.
In ring network, each wavelength can adopt optical channel protection, as shown in
Figure 5-3.
5-3
5 Protection
Nomal
Protection
Working wavelength
Protection wavelength
Fiber cut
The advantages of optical channel protection are fast switching and no need for
protection switching protocol.
Some OTUs like LWM, LWX, LDG, LQS, LGS, AP4 and EC8 have such a function
called dual-fed signal selection, which could realize the optical channel protection, as
shown in Figure 5-4.
At the client side, optical signals are accessed by the OTU boards, then these signals
are reshaped, regenerated, retimed, and sent to the working channel and protection
channel through a splitter. At the receiving end, another OTU will receive the signals
from both the working channel and the protection channel. The channel of signals with
better quality is further processed and sent to the client side.
The advantage of this protection scheme is low cost. The disadvantage is that if the
OTU itself is damaged, no protection will be provided.
Working
channel
Proction
channel
OTU (dual-fed
signal selection)
Client-side
equipment
5-4
5 Protection
For the protected wavelength, the SCS board at the transmitting end divides the
incoming client side services into two channels, and sends them to the working OTU
and protection OTU. Another SCS board at the receiving end combines the services
from the working OTU and the protection OTU, and sends them to the client side.
Figure 5-5 shows the mechanism.
n
n
East
West
West/Backup
OTU
n
n
East/Primary
OTU
SCS
Add
Drop
In normal condition, the services in the working channel will be received and further
processed, while the services in the protection channel will be terminated. That is,
optical signals are output from the working channel at the receiving end and the client
side optical transmitter of the protection channel is shut down.
If LOS alarm is detected in the working channel, the services in the protection channel
will be received and processed while the services in the working channel will be
terminated. That is, optical signals are output from the protection channel and the
client-side optical transmitter at the receiving end is shut down.
You can select protection or non-protection for every service channel. If selecting
protection, the number of OTU boards should be doubled and a certain number of
SCS boards are required. Refer to OptiX BWS 1600G Backbone DWDM Optical
Transmission Hardware Description Manual for detailed description of SCS
This optical channel protection is usually used in ring networking.
Note:
To realize 1+1 optical channel protection, it is required to set channel protection pair
on the NM.
5-5
5 Protection
The SCS can split or couple two optical signals. As shown in Figure 5-6, after
receiving two client optical signals, the SCS splits each signal into two channels and
then sends them to the working and protection OTUs, respectively. After convergence
and wavelength conversion, the signals are sent to the line for transmission.
When a channel of client signal received by working OTU is faulty, only this channel of
signal is switched. No switching is performed at WDM side. That is, the working OTU
in the opposite end will shut down the client-side transmitting laser corresponding to
this failed channel, and the protection OTU in the opposite end will turn on the
corresponding client-side transmitting laser. Other normal signals are still transmitted
through the working OTU.
The client-side protection can be seen as a subset of 1+1 OTU inter-board protection.
When protection switching occurs, only part of client-side services is switched to the
protection OTU, no need for switching all services.
Protection
OTU
Working
OTU
SCS
Client-side
equipment
Client-side
equipment
Important services can be protected by backing up the OTU board, as shown in Figure
5-7.
5-6
5 Protection
OTU
OTU
OTU
OTU
OTU
OTU
OTU
OTU
O
C
P
M
4
0
D
4
0
Protection channel
OTU
Working channels
OTU
OTU
OTU
OTU
OTU
OTU
OTU
OTU
Protection channel
9
O
C
P
8 output channels
8 input channels
Working channels
OTU
Note:
1. N (N8) working OTU boards and one standby OTU form one protection group. But
in such a protection group, each OTU and the OCP board must be plugged in the
same subrack.
2. To realize 1:N (N8) OTU protection, it is required to set protection pair on the NM.
LWF/LWFS
LWS
LWC1
5-7
5 Protection
Clock
TC
Working channel
1510 nm
Working channel
1510 nm
To
BITS
FIU
FIU
TC
TC
1625 nm
Protection channel
1625 nm
Protection channel
TC
Figure 5-8 Schematic diagram of clock channel protection (dual-fed and dual-receiving)
In the second mode, clock selection is made inside the equipment and single-channel
clock is output, as shown in Figure 5-9.
Working channel
1510 nm
Working channel
1510 nm
Clock
TC
TC
FIU
FIU
TC
TC
Clock Output
1625 nm
Protection channel
1625 nm
Protection channel
Figure 5-9 Schematic diagram of clock channel protection (dual-fed signal selection)
TC1 (unidirectional optical supervisory channel and timing transporting unit) is used in
the OTM and supports three input/output clocks locally.
TC2 (bidirectional optical supervisory channel and timing transporting unit) supports
three clocks output locally and three clocks input to the system. It is used in the OLA,
OADM and REG.
To provide 1+1 clock redundancy, two TC1 or TC2 boards are used, working at 1510
nm (active) and 1625 nm (standby). To provide redundancy, two TC boards must be
plugged in slot 6 and slot 8 on the subrack at the same time (the board in slot 8 is the
backup for the board in slot 6). When only one TC board is being used, the clock
protection function cannot be activated.
The transmission of up to 3 clocks in west direction and 3 clocks in east direction is
supported.
5-8
5 Protection
The clock transmission protection mechanism of the OptiX BWS 1600G system is
discussed below:
(1) The intermediate station does not add/drop clock signals
If there is no intermediate site in bidirectional configuration, the transmission of 3 clock
signals in both directions can be supported. As shown in Figure 5-10, the networking
is the same as the point-to-point clock transmission system.
OTM
T1
T2
T3
T4
T5
T6
OTM
1510 nm
T
C
1
1510 nm
T
C
1
1625 nm
T4
T5
T6
T
C
1
1625 nm
T
C
1
T1
T2
T3
T4
T5
T6
T1
T2
T3
Figure 5-10 Configuration of the system with clock protection function but without add/drop of clock
signals at intermediate station
5-9
5 Protection
T4 T5T6 A B C
1510 nm
T1
T2
T3
1510 nm
T
C
2
1510 nm
1625 nm
T1
T2
T3
1510 nm
T
C
2
1625 nm
D
E
F
1510 nm
1625 nm
D
E
F
1625 nm
A B C
Optical signal without clock
Electrical clock signal from/to backplane
Clock signals transmitted over optical fiber
Figure 5-11 Configuration of the intermediate station with clock protection function and with the add/drop
of clock signals
OTM
T1
T2
T3
OTM
T
C
1
T
C
1
1510 nm
1625 nm
T
C
1
T1
T2
T3
T
C
1
T1
T2
T3
Figure 5-12 Configuration of the intermediate station with clock protection function and with the add/drop
of clock signals
The clock is protected only from one direction, that is, either from east direction or from
west direction. Clock protection is enabled from NM.
Huawei Technologies Proprietary
5-10
5 Protection
Note:
1. The clock protection switching takes one channel of clock as the switching unit.
2. To realize the clock protection function of the network clock, it is required to set the
clock protection group on the NM.
NE A
Normal supervisory channel
NM
Management information
GNE
Management information
Normal supervisory channel
NE C
NE D
Optical fiber
Network cable
Figure 5-13 Network management protection in ring network (a certain section fails)
5-11
5 Protection
GNE
Normal supervisory channel
Management information
NM
DCN
Network cable
Router
Router
Optical fiber
Upon the failure of the normal supervisory channel, network elements automatically
switch the management information to the backup supervisory channel to guarantee
the supervisory and operation on the entire network, as illustrated in Figure 5-15.
GNE
NE
Normal supervisory channel
NM
Management information
DCN
Network cable
Router
Router
Optical fiber
It is important to select different routes for the backup supervisory channel and normal
channel during network planning. Otherwise the backup function will not take
effective.
5-12
5 Protection
Network
management
center
ADM
SDH
network
ADM
Network
management
channel
ADM
ADM
Network
management
channel
A
B
DWDM
network
C
ADM
Network
management
channel
ADM
SDH
network
ADM
ADM
ADM
5-13
ADM
6 Technical Parameters
Technical Parameters
38.4 V to 57.6 V DC or
48.0 V to 72.0 V DC
6-1
6 Technical Parameters
Cabinet
Height (mm)
Width (mm)
Depth (mm)
Weight (kg)
Type 1
2200
600
300
69
Type 2
2600
600
300
78
625
495
291
18 (Note 1)
Subrack
Board
Weight
(kg)
Number of
slots
Normal
temperature
High temperature
50 GHz
45.5
110% of power
consumption at normal
temperature
1.55
100 GHz
38
110% of power
consumption at normal
temperature
1.55
51
110% of power
consumption at normal
temperature
1.55
50 GHz
32
110% of power
consumption at normal
temperature
1.25
100 GHz
24
110% of power
consumption at normal
temperature
1.25
LRFS
37
110% of power
consumption at normal
temperature
1.25
LWS
52
110% of power
consumption at normal
temperature
1.76
LWF
LWFS
LRF
6-2
6 Technical Parameters
Board
Weight
(kg)
Number of
slots
Normal
temperature
High temperature
38
110% of power
consumption at normal
temperature
1.46
50 GHz
60.5
110% of power
consumption at normal
temperature
2.1
100 GHz
53
110% of power
consumption at normal
temperature
2.1
OCUS
66
110% of power
consumption at normal
temperature
2.1
TMX
38.8
110% of power
consumption at normal
temperature
2.1
TMXS
42
110% of power
consumption at normal
temperature
2.1
LBE
44.3
110% of power
consumption at normal
temperature
1.2
LBES
48
110% of power
consumption at normal
temperature
1.2
TMR
35
110% of power
consumption at normal
temperature
1.2
TMRS
40
110% of power
consumption at normal
temperature
1.2
LDG
35
110% of power
consumption at normal
temperature
1.1
LQS
30
110% of power
consumption at normal
temperature
1.2
LGS
35
110% of power
consumption at normal
temperature
1.2
LRS
OCU
6-3
6 Technical Parameters
Power consumption (W)
Weight
(kg)
Number of
slots
Normal
temperature
High temperature
AP4
46
110% of power
consumption at normal
temperature
1.2
EC8
35
110% of power
consumption at normal
temperature
1.2
TWC
20
110% of power
consumption at normal
temperature
0.94
LWM
21
110% of power
consumption at normal
temperature
1.1
LWX
12
110% of power
consumption at normal
temperature
1.0
LWC
21.4
110% of power
consumption at normal
temperature
1.1
LWC1
21.4
110% of power
consumption at normal
temperature
1.1
TRC
21
110% of power
consumption at normal
temperature
1.0
TRC1
21
110% of power
consumption at normal
temperature
1.0
TRF
23
110% of power
consumption at normal
temperature
1.2
M40
20
110% of power
consumption at normal
temperature
1.6
V40
46
110% of power
consumption at normal
temperature
2.2
D40
20
110% of power
consumption at normal
temperature
1.6
6-4
6 Technical Parameters
Board
Weight
(kg)
Number of
slots
Normal
temperature
High temperature
MB2
110% of power
consumption at normal
temperature
1.05
MR2
110% of power
consumption at normal
temperature
1.05
ITL
30
110% of power
consumption at normal
temperature
2.0
FIU-I
4.28
110% of power
consumption at normal
temperature
0.85
FIU-II
4.28
110% of power
consumption at normal
temperature
0.85
FIU-III
4.28
110% of power
consumption at normal
temperature
0.85
FIU-IV
4.28
110% of power
consumption at normal
temperature
0.85
OAU-C
30
50
2.4
OAU-L
42
70
2.4
OBU-C
23
30
2.15
OBU-L
35
50
2.15
OPU
20
110% of power
consumption at normal
temperature
2.0
WBA05/WBA06
20
110% of power
consumption at normal
temperature
1.2
HBA
65
110% of power
consumption at normal
temperature
2.6
RPC
70
110% of power
consumption at normal
temperature
4.2
FIU
OAU
6-5
6 Technical Parameters
Power consumption (W)
Weight
(kg)
Number of
slots
Normal
temperature
High temperature
RPL
25
110% of power
consumption at normal
temperature
1.5
RPA
90
110% of power
consumption at normal
temperature
4.25
SC1
4.0
110% of power
consumption at normal
temperature
0.85
SC2
7.0
110% of power
consumption at normal
temperature
1.0
TC1
8.5
110% of power
consumption at normal
temperature
0.86
TC2
11.5
110% of power
consumption at normal
temperature
1.05
SCC
10.5
110% of power
consumption at normal
temperature
0.75
SCE
10.4
110% of power
consumption at normal
temperature
0.7
FMU
25
110% of power
consumption at normal
temperature
2.5
MWF
110% of power
consumption at normal
temperature
0.8
MWA
110% of power
consumption at normal
temperature
0.8
OCP
110% of power
consumption at normal
temperature
1.7
OLP
110% of power
consumption at normal
temperature
0.8
6-6
6 Technical Parameters
Power consumption (W)
Weight
(kg)
Number of
slots
Normal
temperature
High temperature
SCS
4.28
110% of power
consumption at normal
temperature
0.7
PBU
145
110% of power
consumption at normal
temperature
1.0
MCA8/MCA4
110% of power
consumption at normal
temperature
1.7
DGE
20
110% of power
consumption at normal
temperature
2.35
DSE
4.28
110% of power
consumption at normal
temperature
0.85
GFU
4.28
110% of power
consumption at normal
temperature
0.85
VA4
10
110% of power
consumption at normal
temperature
1.5
VOA
6.5
110% of power
consumption at normal
temperature
0.75
6-7
6 Technical Parameters
Item
Parameter
Altitude
4000 m
Air pressure
70106 kPa
Temperature
0C40C
Relative Humidity
10%90%
Antiseismic performance
S1
RM1
S2
RM2
Sn RMn
M MPI-S
U
X
R'
OA
S'
SD1
D
MPI-R M S D2
U
X S Dn
R1
R2
Rn
Rx 1
Rx 2
Rx n
OSC
Figure 6-1 Typical DWDM network diagram
Optical Interface characteristic at points MPI-S or S' and MPI-R or R' as well as the
main optical path parameters are shown in the following tables. In this section, the
span specifications are provided when FEC technology is adopted and the Raman
technology is not used.
6-8
6 Technical Parameters
Item
Unit
Performance Parameter
Span of line
5 20 dB
2 24 dB
1 28 dB
Number of channels
160
160
160
STM64
STM64
STM64
Average
dBm
+1.0
+1.0
+1.0
Maximum
dBm
+3.0
+3.0
+3.0
Minimum
dBm
3.0
3.0
1.0
dBm
+20.0
+20.0
+20.0
dB
+1.5
+1.5
+1.5
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
7500
3600
2100
dB
27
27
27
ps
15
15
15
Average
dBm
22
26
30
Maximum
dBm
18
22
27
Minimum
dBm
26
30
33
dBm
11
dB
20
20
20
dB
dB
1.5
1.5
1.5
6-9
6 Technical Parameters
Item
Unit
Performance Parameter
Span of line
7 22 dB
4 25 dB
1 32 dB
Number of channels
80
80
80
STM64
STM64
STM64
Average
dBm
+4.0
+4.0
+4.0
Maximum
dBm
+7.0
+7.0
+6.0
Minimum
dBm
+1.0
+1.0
+2.0
dBm
+20.0
+20.0
+20.0
dB
+1.5
+1.5
+1.5
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/n
m
11200
7600
2400
dB
27
27
27
ps
15
15
15
Average
dBm
21
24
31
Maximum
dBm
17
20
28
Minimum
dBm
25
28
34
dBm
15
dB
20
20
20
dB
dB
1.5
1.5
1.5
6-10
6 Technical Parameters
Table 6-5 Main optical path parameters of the OptiX BWS 1600G-II ELH transmission system (C+L,
G.652/G.655 fiber)
Item
Unit
Performance parameter
Span of line
14 22 dB
5 27 dB
Number of channels
80
80
STM64
STM64
Average
dBm
+4.0
+4.0
Maximum
dBm
+7.0
+7.0
Minimum
dBm
+1.0
+1.0
dBm
+20.0
+20.0
dB
+1.5
+1.5
dB
>30
>30
dB
dB
Maximum dispersion
ps/n
m
22400
10000
dB
27
27
ps
15
15
Average
dBm
21
26
Maximum
dBm
17
22
Minimum
dBm
25
30
dBm
11
dB
17
17
dB
dB
1.5
1.5
The parameters in Table 6-5 are provided when SuperWDM technology is adopted.
6-11
6 Technical Parameters
Table 6-6 Main optical path parameters of the OptiX BWS 1600G-II (C, G.652 fiber)
Item
Unit
Performance parameter
Span of line
NRZ
8 22 dB
5 25 dB
1 32 dB
CRZ
12 22 dB
7 25 dB
1 36 dB
Number of channels
80
80
80
STM64
STM64
STM64
Average
dBm
+4
+4
+4
Maximum
dBm
+8
+7
+6
Minimum
dBm
+1
+2
dBm
23
23
23
dB
1.5
1.5
1.5
dB
>30
>30
>30
dB
dB
1.5
1.5
1.5
Maximum dispersion
ps/nm
12800 (NRZ)
9500 (NRZ)
2400 (NRZ)
19200 (CRZ)
13300 (CRZ)
2800 (CRZ)
dB
27
27
27
ps
15
15
15
21
24
31Note 1 (NRZ)
Average
dBm
35 Note 2 (CRZ)
Maximum
dBm
17
20
28 (NRZ)
34 (CRZ)
Minimum
dBm
25
28
32 (NRZ)
38 (CRZ)
6-12
6 Technical Parameters
Item
Unit
Performance parameter
dBm
dB
12 (NRZ)
16 (CRZ)
20 (NRZ)
20 (NRZ)
20 (NRZ)
17 (CRZ)
17 (CRZ))
17 (CRZ)
dB
dB
1.5
1.5
1.5
6-13
6 Technical Parameters
Table 6-7 Main optical path parameters of the OptiX BWS 1600G-II (C, G.655 fiber)
Item
Unit
Performance parameter
Span of line
NRZ
8 22 dB
3 25 dB
1 30 dB
CRZ
10 22 dB
6 25 dB
1 32 dB
Number of channels
80
80
80
STM64
STM64
STM64
Average
dBm
+1
+1
+1
Maximum
dBm
+5
+4
+3
Minimum
dBm
dBm
20
20
20
dB
1.5
1.5
1.5
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
2880 (NRZ)
1710 (NRZ)
660 (NRZ)
4800 (CRZ)
3420 (CRZ)
720 (CRZ)
dB
27
27
27
ps
15
15
15
24
27
32 Note 1 (NRZ)
Average
dBm
34 Note 2 (CRZ)
Maximum
dBm
20
24
29 (NRZ)
35 (CRZ)
Minimum
dBm
28
30
31 (NRZ)
37 (CRZ)
dBm
13 (NRZ)
15 (CRZ)
6-14
6 Technical Parameters
Item
Unit
Performance parameter
dB
20 (NRZ)
20 (NRZ)
20 (NRZ)
17 (CRZ)
17 (CRZ))
17 (CRZ)
dB
dB
1.5
1.5
1.5
6-15
6 Technical Parameters
Item
Unit
Performance parameter
Span of line
10 22 dB
5 27 dB
1 34 dB
Number of channels
40
40
40
STM64
STM64
STM64
Average
dBm
+4.0
+4.0
+4.0
Maximum
dBm
+7.0
+7.0
+6.0
Minimum
dBm
+1.0
+1.0
+2.0
dBm
+20.0
+20.0
+20.0
dB
+1
+1
+1
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
16000
10000
2500
dB
27
27
27
ps
15
15
15
Average
dBm
20
25
32
Maximum
dBm
16
21
29
Minimum
dBm
24
29
35
dBm
16
dB
20
20
20
dB
dB
6-16
6 Technical Parameters
Table 6-9 Main optical path parameters of the OptiX BWS 1600G-III ELH transmission system
(G.652/G.655 fiber)
Item
Unit
Performance parameter
Span of line
25 22 dB
10 27 dB
Number of channels
40
40
STM64
STM64
Average
dBm
+4.0
+4.0
Maximum
dBm
+7.0
+7.0
Minimum
dBm
+1.0
+1.0
dBm
+20.0
+20.0
dB
+1
+1
dB
>30
>30
dB
dB
Maximum dispersion
ps/nm
40000
20000
dB
27
27
ps
15
15
Average
dBm
20
25
Maximum
dBm
16
21
Minimum
dBm
24
29
dBm
dB
17
17
dB
dB
6-17
6 Technical Parameters
adopted.
Table 6-10 Main optical path parameters of the OptiX BWS 1600G-III 8-channel system (G.653 fiber)
Item
Unit
Performance parameter
Span of line
8 20 dB
3 28 dB
1 33 dB
Number of channels
STM64
STM64
STM64
System wavelength
THz
192.1,192.3,192.6,193.0,195.1,195.5,195.8,1
96.0
Average
dBm
+1.0
+1.0
+1.0
Maximum
dBm
+2.0
+2.0
+2.0
Minimum
dBm
2.0
2.0
2.0
dBm
+11.0
+11.0
+11.0
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
dB
27
27
27
ps
30
30
30
Average
dBm
20
28
33
Maximum
dBm
16
25
29
Minimum
dBm
24
31
35
dBm
16
21
dB
20
20
20
dB
dB
Note: The channel output power is the input optical power of the system at point S, including FIU loss at the transmitting
end.
6-18
6 Technical Parameters
Item
Unit
Performance parameter
Span of line
6 23 dB
3 27 dB
1 32 dB
Number of channels
12
12
12
STM64
STM64
STM64
System wavelength
THz
Average
dBm
Maximum
dBm
+1.0
+1.0
+1.0
Minimum
dBm
3.0
3.0
3.0
dBm
+11.0
+11.0
+11.0
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
dB
27
27
27
ps
30
30
30
Average
dBm
24
28
33
Maximum
dBm
20
25
29
Minimum
dBm
28
31
35
dBm
11
15
20
dB
20
20
20
dB
dB
Note: The channel output power is the input optical power of the system at point S, including FIU loss at the transmitting
end.
6-19
6 Technical Parameters
Item
Unit
Performance parameter
Span of line
5 22 dB
3 25 dB
1 30 dB
Number of channels
40
40
40
STM64
STM64
STM64
Average
dBm
+1.0
+1.0
+1.0
Maximum
dBm
+2.0
+2.0
+2.0
Minimum
dBm
2.0
2.0
2.0
dBm
+17.0
+17.0
+17.0
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
1600
1080
440
dB
27
27
27
ps
30
30
30
Average
dBm
22
25
30
Maximum
dBm
19
22
27
Minimum
dBm
25
28
33
dBm
10
dB
20
20
20
dB
dB
Note: The channel output power is the input optical power of the system at point S, including FIU loss at the transmitting
end.
6-20
6 Technical Parameters
Item
Unit
Performance parameter
Span of line
8 22 dB
6 27 dB
1 39 dB
Number of channels
40
40
40
STM16
STM16
STM16
Average
dBm
+4.0
+4.0
+4.0
Maximum
dBm
+7.0
+7.0
+6.0
Minimum
dBm
+1.0
+1.0
+2.0
dBm
+20.0
+20.0
+20.0
dB
+1
+1
+1
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/n
m
12800
12000
3000
dB
27
27
27
ps
15
15
15
Average
dBm
20
25
37
Maximum
dBm
16
21
34
Minimum
dBm
24
39
40
dBm
20
dB
20
20
20
dB
dB
6-21
6 Technical Parameters
Item
Unit
Performance parameter
Span of line
1 51 dB
1 44 dB
1 47 dB
Number of channels
10
10
10
STM16
STM64
STM64
Average
dBm
+16
+16
+16
Maximum
dBm
+17
+17
+17
Minimum
dBm
+14
+14
+14
dBm
+26
+26
+26
dB
+1
+1
+1
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/n
m
3600
3200
3400
dB
27
27
27
ps
15
15
15
Average
dBm
37
30
33
Maximum
dBm
35
28
31
Minimum
dBm
39
32
35
dB
15
20
18
dB
dB
For the 10-channel LHP system of type VI, the frequency range is
Huawei Technologies Proprietary
6-22
6 Technical Parameters
Item
Unit
Performance parameter
Span of line
1 46 dB
1 41 dB
1 37 dB
Number of channels
40
40
40
STM16
STM64
STM64
Average
dBm
+10
+10
+10
Maximum
dBm
+12
+12
+12
Minimum
dBm
+8
+8
+8
dBm
+26
+26
+26
dB
+1
+1
+1
dB
>30
>30
>30
dB
dB
Maximum dispersion
ps/nm
3200
3100
2800
dB
27
27
27
ps
15
15
12
Average
dBm
37
33
29
Maximum
dBm
34
30
26
Minimum
dBm
40
36
32
dB
15
18
20
dB
dB
6-23
6 Technical Parameters
Item
Unit
nm
Performance parameter
23 dB
28 dB
33 dB
1529.161560.61
/
1529.161560.61
/
1529.161560.61/
1570.421603.57
1570.421603.57
1570.421603.57
dBm
32 to 3
32 to 3
32 to 3
Single channel
input power
range
40 channels
dBm
32 to 19
32 to 19
32 to 19
80 channels
dBm
32 to 22
32 to 22
32 to 22
dB
510
510
510
Input reflectance
dB
<40
<40
<40
Output reflectance
dB
<40
<40
<40
dBm
<30
<30
<30
dB
27
27
27
dB
27
27
27
dBm
20
20
20
ms
<10
<10
<10
Channel gain
dB
2126
2631
3136
Gain flatness
dB
dB/dB
dB
0.5
0.5
0.5
The OAU-CR/LR of the OptiX BWS 1600G system is always used with Raman fiber
amplifier.
6-24
6 Technical Parameters
Item
Unit
nm
Performance parameter
13 dB
18 dB
1529.161560.61
/
1529.161560.61
/
1570.421603.57
1570.421603.57
23 dB
1529.161560.61/
1570.421603.57
dBm
22 to +7
22 to +7
22 to +7
Single
channel input
power range
40 channels
dBm
22 to 9
22 to 9
22 to 9
80 channels
dBm
22 to 12
22 to 12
22 to 12
dB
510
510
510
Input reflectance
dB
<40
<40
<40
Output reflectance
dB
<40
<40
<40
dBm
<30
<30
<30
dB
27
27
27
dB
27
27
27
dBm
20
20
20
ms
<10
<10
<10
Channel gain
dB
1116
1621
2126
dB
dB/d
B
dB
0.5
0.5
0.5
Note: The flatness value is obtained when OAU and Raman amplifier are used together.
The OAU used for the C 800G system is OAU05. Table 6-18shows its specifications.
6-25
6 Technical Parameters
Item
Unit
Performance patameter
nm
40-channel system
80-channel system
1529.161560.61
1529.161560.61
dBm
32 to 0
32 to 0
dBm
32 to 16
32 to 19
dB
<10
<10
Output reflectance
dB
<40
<40
Input reflectance
dB
<40
<40
dBm
<30
<30
dB
27
27
dB
27
27
dBm
23
23
ms
<10
<10
dB
36
36
Gain flatness
dB
dB/dB
dB
<0.5
<0.5
6-26
6 Technical Parameters
6.7.2 OBU
Table 6-19 Parameters of OBU-C/L for C/L-band
Item
Unit
Application
Operating wavelength range
nm
Performance parameter
Multi-span (OBU03)
LHP (OBU05)
1529.161560.61/
1529.161560.61
1570.421603.57
Total input power
dBm
22 to 3
22 to 0
40 channels
dBm
22 to 19
16
80 channels
dBm
22
19
dB
<6/6.5
<8
Input reflectance
dB
<40
<40
Output reflectance
dB
<40
<40
dBm
<30
<30
dB
27
27
dB
27
27
dBm
20
23
ms
<10
<10
Channel gain
dB
23
23
Gain flatness
dB
dB/dB
dB
0.5
0.5
Single channel
input power range
Note: In performance parameters column, the parameters before / are for C band, and those after / are for L band.
6-27
6 Technical Parameters
6.7.3 OPU
Table 6-20 Parameters of OPU
Item
Unit
Performance parameter
nm
1529.161560.61
dBm
32 to 8
dBm
32 to 23
dB
<5.5
Input reflectance
dB
<40
Output reflectance
dB
<40
dBm
<30
dB
27
dB
27
dBm
15
ms
<10
Channel gain
dB
2225
Gain flatness
dB
dB/dB
dB
0.5
6-28
6 Technical Parameters
6.7.4 WBA
Table 6-21 Parameters of WBA
Item
Unit
Application
nm
15351561
15351561
dBm
28 to 6
21 to 3
dB
<5.5
<5.5
Input reflectance
dB
<30
<30
Output reflectance
dB
<30
<30
dBm
<30
<30
dB
27
27
dB
27
27
dBm
15
15
ms
<10
<10
Channel gain
dB
1921
1618
Gain flatness
dB
dB/dB
dB
0.5
0.5
6-29
6 Technical Parameters
6.7.5 HBA
Table 6-22 Parameters of HBA
Item
Unit
Performance parameter
40-channel
10-channel
nm
192.1196.0 THz
192.1194.0 THz
dBm
19 to 3
19 to 9
dB
<8
<8
Output reflectance
dB
<45
<45
dBm
1026
1626
ms
<10
<10
Channel gain
dB
29
35
Gain flatness
dB
2.5
2.5
dB
<0.5
<0.5
ps
<0.5
<0.5
6-30
6 Technical Parameters
Item
Unit
Performance parameter
nm
14001500
Board type
C band: RPC
dBm
30.5
31.5
dB
10
10
dB
12
10
dB
13
10
dB
dB
-0.5
0.5
dB
dB
0.3
0.3
Temperature characteristic
nm/C
Note 1: This gain refers to on-off gain, i.e. the power difference between amplifier ON and amplifier OFF.
Note 2: LEAF fiber is a kind of fiber called large effective aperture fiber.
Note 3: TW RS fiber is a kind of fiber called True Wave Reduced Slope fiber, belongs to NZDSF.
6-31
6 Technical Parameters
6.8.1 LWF
Table 6-24 Optical interface (STM64) parameters at the client end of the LWF board
Item
Unit
Parameter
I64.2
S64.2b
NRZ
NRZ
SLM
SLM
km
25
40
nm
15301565
15301565
dBm
+2
dBm
10
dB
+8.2
+8.2
dB
30
30
PIN
PIN
Target distance
Transmitter parameters at point S
nm
12001650
12001650
Receiver sensitivity
dBm
14
14
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-32
6 Technical Parameters
Table 6-25 Optical interface (STM64) parameters at the DWDM side of the LWF board
Item
Unit
Parameter
Channel spacing
GHz
50
100
NRZ
NRZ
dBm
dBm
dB
+10
+10
THz
192.10196.05,
192.10196.05,
186.95190.90
186.95190.90
GHz
10
nm
0.3
0.3
Minimum SMSR
dB
35
35
Maximum dispersion
ps/nm
1500
800
PIN
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
14
14
Receiver overload
dBm
Maximum reflectance
dB
27
27
The optical interface parameters of the LRF board are as shown in Table 6-25.
LWS/LRS has the same parameters as the LWF.
6-33
6 Technical Parameters
6.8.2 LWFS
The optical interface parameters at the client end of the LWFS board are the same
as those of LWF board; the optical interface parameters at the DWDM side are
shown in Table 6-26.
Table 6-26 Optical interface (STM64) parameters at the DWDM side of the LWFS board
Item
Unit
Parameter
Channel spacing
GHz
100 or 50
CRZ
dBm
dBm
dB
+13
Central frequency
THz
192.10196.05
GHz
10/5 Note 1
Minimum SMSR
dB
NA
Maximum dispersion
ps/nm
300+500
NA
PIN
nm
12001650
Receiver sensitivity
dBm
17
Receiver overload
dBm
Maximum reflectance
dB
27
Note 1: The deviation 10 refers to 100 GHz channel spacing, while 5 refers to 50 GHz channel
spacing.
The optical interface parameters of the LRFS are as shown in Table 6-26.
6-34
6 Technical Parameters
6.8.3 OCU
Table 6-27 Optical interface (STM16) parameters at the client end of the OCU board
Item
Unit
Parameter
I16
S16.1
L16.2
NRZ
NRZ
NRZ
MLM
SLM
SLM
15
80
Target distance
km
nm
12601360
12601360
15001580
dBm
+3
dBm
10
dB
+8.2
+8.2
+8.2
Minimum SMSR
dB
NA
30
30
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
PIN
PIN
APD
nm
12001650
12001650
12001650
Receiver sensitivity
dBm
18
18
28
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
6-35
6 Technical Parameters
Table 6-28 Optical interface (STM64) parameters at the DWDM side of the OCU board
Item
Unit
Parameter
Channel spacing
GHz
50
100
NRZ
NRZ
dBm
dBm
dB
+10
+10
Central frequency
THz
192.10196.05,
192.10196.05,
186.95190.90
186.95190.90
GHz
10
nm
0.3
0.3
Minimum SMSR
dB
35
35
Maximum dispersion
ps/nm
1500
800
PIN
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
14
14
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-36
6 Technical Parameters
6.8.4 OCUS
The optical interface parameters at the client end of the OCUS board are the same
as those of the OCU board; the optical interface parameters at the DWDM side are
shown in Table 6-29.
Table 6-29 Optical interface (STM64) parameters at DWDM side of the OCUS board
Item
Unit
Parameter
Channel spacing
GHz
100 or 50
CRZ
dBm
dBm
dB
+13
Central frequency
THz
192.10196.05
GHz
10/5Note 1
dB
NA
Maximum dispersion
ps/nm
300+500
NA
PIN
nm
12001650
Receiver sensitivity
dBm
17
Receiver overload
dBm
Maximum reflectance
dB
27
Note 1: The deviation 10 refers to 100 GHz channel spacing, while 5 refers to 50 GHz channel
spacing.
6-37
6 Technical Parameters
6.8.5 TMX
Table 6-30 Optical interface parameters at client side of the TMX board
Item
Unit
Parameter
I16
S16.1
L16.1
L16.2
NRZ
NRZ
NRZ
NRZ
SLM
SLM
SLM
SLM
15
Target distance
km
80
nm
12601360
12601360
12601360
15001580
Maximum mean
launched power
dBm
+3
+3
dBm
10
dB
+8.2
+8.2
+8.2
+8.2
Minimum side-mode
suppression ratio
dB
NA
30
30
30
Clock quality
PIN
PIN
APD
APD
Operating wavelength
range
nm
12601570
12601570
12601570
12601570
Receiver sensitivity
dBm
18
18
27
28
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
27
Clock quality
6-38
6 Technical Parameters
Table 6-31 Optical interface parameters at line side of the TMX board
Item
Unit
Parameter
Channel spacing
GHz
50
100
NRZ
NRZ
dBm
dBm
dB
+10
+10
Central frequency
THz
192.10196.05,
192.10196.05,
186.95190.90
186.95190.90
GHz
10
nm
0.3
0.3
dB
35
35
Maximum dispersion
ps/nm
1500
800
PIN
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
14
14
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-39
6 Technical Parameters
6.8.6 TMXS
The optical interface parameters at client side of the TMXS board are the same as
those of the TMX board. The line side optical interface parameters are shown in
Table 6-32.
Table 6-32 Optical interface parameters at line side of the TMXS board
Item
Unit
Parameter
Channel spacing
GHz
100 or 50
CRZ
dBm
dBm
dB
+13
Central frequency
THz
192.10196.05
GHz
10/5Note1
dB
NA
Maximum dispersion
ps/nm
300 to +500
NA
PIN
nm
12001650
Receiver sensitivity
dBm
17
Receiver overload
dBm
Maximum reflectance
dB
27
Note 1: The deviation 10 refers to 100 GHz channel spacing, while 5 refers to 50 GHz channel
spacing.
6-40
6 Technical Parameters
Item
Unit
Parameter
Gbit/s
I64.1
I64.2
S64.2b
S64.2a
nm
12601360
15301565
15301565
15301565
dBm
+2
+2
dBm
11
10
dB
+6
+8.2
+8.2
+8.2
nm
12001650
12001650
12001650
12001650
Receiver sensitivity
dBm
11
14
14
14
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
27
6-41
6 Technical Parameters
Table 6-34 Optical interface parameters at line side of the LBE boards
Item
Unit
Board type
Parameter
LBE
Channel spacing
GHz
LBES
50
100
100 or 50
NRZ
NRZ
Super CRZ
dBm
dBm
dB
+10
+10
+13
Central frequency
THz
192.10196.05,
192.10196.05,
186.95190.90
186.95190.90
192.10196.05
GHz
10
10/5Note 1
nm
0.3
0.3
NA
dB
35
35
NA
Maximum dispersion
ps/nm
1500
800
300+500
Compliant with
G.691
Compliant with
G.691
NA
PIN
PIN
PIN
nm
12001650
12001650
12001650
Receiver sensitivity
dBm
14
14
17
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
Note 1: The deviation 10 refers to 100 GHz channel spacing, while 5 refers to 50 GHz channel spacing.
The parameters of the TMR and TMRS boards are the same as those of the optical
interface parameters at line side of the LBE and LBES boards.
6-42
6 Technical Parameters
Item
Unit
Parameter
I16
S16.1
L16.2
NRZ
NRZ
NRZ
MLM
SLM
SLM
km
15
80
nm
12601360
12601360
15001580
dBm
+3
dBm
10
dB
+8.2
+8.2
+8.2
Minimum side-mode
suppression ratio
dB
NA
30
30
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
PIN
PIN
APD
Target distance
Transmitter parameters at point S
nm
12001650
12001650
12001650
Receiver sensitivity
dBm
18
18
28
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
6-43
6 Technical Parameters
Table 6-36 Optical interface (STM16) parameters at the DWDM side of the LWC/LWC1 board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
dBm
dBm
10
dB
+10
Central frequency
THz
192.10196.00
GHz
10
nm
0.2
Minimum SMSR
dB
35
Maximum dispersion
ps/nm
12800
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
28
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
The optical interface parameters of the TRC/TRC1 are as shown in Table 6-36.
6-44
6 Technical Parameters
6.8.9 LWM
Table 6-37 Optical interface parameters at the client end of the LWM board
Item
Unit
Parameter
STM1/4/16
STM1/4/16
STM1/4/16
NRZ
NRZ
NRZ
MLM
SLM
SLM
km
15
80
nm
12601360
12601360
12601570
dBm
+3
dBm
10
dB
+8.2
+8.2
+8.2
dB
NA
30
30
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
PIN
PIN
APD
Target distance
Transmitter parameters at point S
nm
12001650
12001650
12001650
Receiver sensitivity
dBm
18
18
25
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
6-45
6 Technical Parameters
Table 6-38 Optical interface parameters at DWDM side of the LWM board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
km
640
350
170
dBm
dBm
10
10
10
dB
+10
+10
+10
Central frequency
THz
192.10196.00
192.10196.00
192.10196.00
GHz
10
10
10
nm
0.2
0.2
0.2
Minimum SMSR
dB
35
35
35
Maximum dispersion
ps/nm
12800
6500
3500
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
28
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-46
6 Technical Parameters
6.8.10 LWX
Table 6-39 Optical interface parameters at the client end of the LWX board
Item
Unit
Parameter
34 Mbit/s2.5
Gbit/s
34 Mbit/s2.5
Gbit/s
34 Mbit/s2.5
Gbit/s
NRZ
NRZ
NRZ
MLM
SLM
SLM
15
80
Target distance
km
nm
12601360
12601360
15001580
dBm
+3
dBm
10
dB
+8.2
+8.2
+8.2
Minimum SMSR
dB
NA
30
30
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
PIN
PIN
APD
nm
12001650
12001650
12001650
Receiver sensitivity
dBm
18
18
28
Receiver overload
dBm
Maximum reflectance
dB
27
27
27
6-47
6 Technical Parameters
Table 6-40 Optical interface parameters at the DWDM side of the LWX board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
km
640
350
170
dBm
dBm
10
10
10
dB
+10
+10
+10
Central frequency
THz
192.10196.00
192.10196.00
192.10196.00
GHz
10
10
10
nm
0.2
0.2
0.2
Minimum SMSR
dB
35
35
35
Maximum dispersion
ps/nm
12800
6500
3500
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
28
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-48
6 Technical Parameters
6.8.11 LDG
Table 6-41 Optical interface parameters at the client end of the LDG board
Item
Unit
Parameter
Gbit/s
1.25
nm
12601360
770860
dBm
dBm
11.5
9.5
dB
+8.2
+8.2
nm
12001650
770860
Receiver sensitivity
dBm
19
17
Receiver overload
dBm
Maximum reflectance
dB
12
12
6-49
6 Technical Parameters
Table 6-42 Optical interface parameters at the DWDM side of the LDG board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
km
640
350
170
dBm
dBm
10
10
10
dB
+10
+10
+10
Central frequency
THz
192.10196.00
192.10196.00
192.10196.00
GHz
10
10
10
nm
0.2
0.2
0.2
Minimum SMSR
dB
35
35
35
Maximum dispersion
ps/nm
12800
6500
3500
Compliant with
G.957
Compliant with
G.957
Compliant with
G.957
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
28
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-50
6 Technical Parameters
6.8.12 TWC
Table 6-43 Optical interface parameters of the TWC board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
dBm
dBm
dB
+10
Central frequency
THz
192.10196.00
GHz
10
nm
0.2
Minimum SMSR
dB
35
Maximum dispersion
ps/nm
12800
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
28
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-51
6 Technical Parameters
6.8.13 LGS
Table 6-44 Optical interface parameters at the client end of the LGS board
Item
Unit
Parameter
nm
12601360
770860
dBm
dBm
11
9.5
dB
+8.2
+8.2
12601360
dBm
dBm
15
dB
+8.2
nm
12001355
770860
Receiver sensitivity
dBm
19
17
Receiver overload
dBm
Maximum reflectance
dB
12
12
nm
12001650
Receiver sensitivity
dBm
28
Receiver overload
dBm
Maximum reflectance
dB
<27
6-52
6 Technical Parameters
Table 6-45 Optical interface parameters at the DWDM side of the LGS board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
EA
Direct-modulated
dBm
+2
+7
dBm
10
10
dB
+10
+8.2
Central frequency
THz
192.10196.00
192.10196.00
GHz
10
10
nm
0.2
0.5
Minimum SMSR
dB
35
30
Maximum dispersion
ps/nm
12800
1800
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
28
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-53
6 Technical Parameters
6.8.14 LQS
Table 6-46 Optical interface parameters at the client end of the LQS board
Item
Unit
Parameter
12601360
dBm
dBm
15
dB
+8.2
nm
12001650
Receiver sensitivity
dBm
28
Receiver overload
dBm
Maximum reflectance
dB
<27
The LQS has the same DWDM-side optical interface parameters as the LGS, as
shown in Table 6-46.
6-54
6 Technical Parameters
6.8.15 AP4
Table 6-47 Optical interface parameters at the client end of the AP4 board
Item
Unit
Parameter
Single mode
Multimode
dBm
dBm
11.5
9.5
dB
NA
NA
nm
12001650
12001650
Receiver sensitivity
dBm
19
17
Receiver overload
dBm
6-55
6 Technical Parameters
Table 6-48 Optical interface parameters at line side of the AP4 board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
dBm
dBm
10
dB
+8.2
Central frequency
THz
192.10196.00
GHz
20
nm
0.5
dB
30
Maximum dispersion
ps/nm
12800
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
25
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-56
6 Technical Parameters
6.8.16 EC8
Table 6-49 Optical interface parameters at client side of the EC8 board
Item
Unit
Parameter
Single mode
Multimode
dBm
14
dBm
15
20.5
dB
+8.2
+8.2
nm
12001650
12001650
Receiver sensitivity
dBm
28
29
Receiver overload
dBm
14
6-57
6 Technical Parameters
Table 6-50 Optical interface parameters at line side of the EC8 board
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
dBm
dBm
10
dB
+8.2
Central frequency
THz
192.10196.00
GHz
20
nm
0.5
dB
30
Maximum dispersion
ps/nm
12800
APD
PIN
nm
12001650
12001650
Receiver sensitivity
dBm
25
18
Receiver overload
dBm
Maximum reflectance
dB
27
27
6-58
6 Technical Parameters
6.8.17 OTT
OTT, optical tunable transponder, can be used on the LWF, LRF and OCU boards,
for adjusting transmitting optical wavelength at the DWDM side. The parameters of
the OTT module are shown in Table 6-51.
Table 6-51 Parameters of the OTT module
Item
Unit
Parameter
Channel spacing
GHz
100
NRZ
Signal rate
Gbit/s
Operating wavelength
10.71/10.66
C band
dBm
<3
40
GHz
2.5
Maximum dispersion
ps/nm
1200
PIN
nm
12001650
Receiver sensitivity
dBm
14
Receiver overload
dBm
Maximum reflectance
dB
27
6-59
6 Technical Parameters
-20dB/10dec
F
Jitter Frequency
fc
STM Level
Fc (kHz)
P (dB)
STM16 (A)
2000
0.1
STM64 (A)
1000
0.1
When the OTU with out-band FEC function are employed, the jitter transfer function
shall be tested by a pair of OTUs, i.e., OTU with coding function and OTU with
decoding function are combined (P=0.2 dB) to test as shown in Figure 6-3.
FEC coder
FEC decoder
6-60
6 Technical Parameters
A1
f0
f1
STM Level
f1 (kHz)
f0 (kHz)
A1 (kHz)
A2 (kHz)
STM16 (A)
1,000
100
0.15
1.5
STM64 (A)
4,000
400
0.15
1.5
STM Level
STM16 (A)
STM64 (A)
Peak-peak
amplitude
(UI)
High-pass (KHz)
Low-pass (MHz)
20
0.30
1000
20
0.10
20
80
0.30
4000
80
0.10
6-61
6 Technical Parameters
6.9.1 M40
The parameters of the M40 are shown in Table 6-55.
Table 6-55 Parameters of the M40
Item
Unit
Parameter (40-channel)
Channel spacing
GHz
100
Insertion loss
dB
<10
Reflectance
dB
<40
nm
15291561/15701604
(Note)
dB
>22
dB
>25
dB
<0.5
Temperature characteristics
pm/C
<2
dB
<3
Note: The wavelength range of C-band multiplexer is 1529 nm1561 nm, and that of L-band
multiplexer is 1570 nm1604 nm.
The parameters of the V40 board are the same as those of the M40 board.
6-62
6 Technical Parameters
6.9.2 D40
The parameters of the D40 board are shown in Table 6-56.
Table 6-56 Parameters of the D40
Item
Unit
Parameter (40-channel)
Channel spacing
GHz
Insertion loss
dB
<10
Reflectance
dB
<40
dB
>25
dB
>25
dB
<0.5
Temperature characteristics
pm/C
<2
dB
<3
1 dB spectral width
nm
>0.2
20 dB spectral width
nm
<1.4
6.9.3 MB2
Table 6-57 Parameters of the MB2
Item
Unit
Parameter
Channel spacing
GHz
Wavelength range
nm
C band: 15291570
L band: 15651605
dB
3.0
nm
0.11
dB
> 25
dB
> 35
dB
3.0
dB
0.11
dB
>40
6-63
6 Technical Parameters
Item
Unit
Parameter
dB
2.0
dB
1.0
dB
>13
dB
1.5
IN-OUT isolation
dB
>25
Return loss
dB
>40
6.9.4 MR2
The MR2 provided by Huawei is of multi-layer dielectric film interference filter type.
Its parameters are shown in Table 6-58.
Table 6-58 Parameters of the MR2
Item
Unit
Parameter
Channel spacing
GHz
nm
C band: 15291570
L band: 15651605
nm
>0.2
dB
<2.5
dB
<3.0
dB
>25
dB
<1
Return loss
dB
40
dB
<0.2
ps
0.15
dBm
24
Working temperature
5+55
Temperature characteristics
pm/C
<2
6-64
6 Technical Parameters
Item
Unit
Parameter
Online monitoring
Test wavelength
nm
131025
155025
dB
39.5 (Note 1)
38.5 (Note 1)
10(Note 2)
30 (Note 3)
Pulse width
dBm
20
Distance accuracy
Readout resolution
dB
0.001
Reflection measurement
resolution
dB
2.0
Linearity
dB/dB
0.05
Group index
Working temperature
1.4001.700
C
5+55
Note 1: For the FMU, the loss of online optical switch and coupler is considered, so its dynamic range is 12 dB less than
that of the OTDR. In addition, the effective dynamic range of the OTDR in online monitoring and that in standby fiber
monitoring are different.
Note 2: Test condition: Pulse width of test signal is 10 ns and return loss is not greater than 35 dB.
Note 3: Test condition: Pulse width of test signal is 10 ns and return loss is not greater than 35 dB.
6-65
6 Technical Parameters
Item
Unit
Parameter
nm
15001635
nm
12801340
dB
1.2
dB
0.4
dB
45
dB
45
dB
0.1
ps
0.1
dBm
27
Working temperature
5+55
Item
Unit
Parameter
nm
15001635
nm
12801340
dB
1.2
dB
1.0
dB
0.4
dB
40
dB
40
dB
45
Directivity
dB
55
dB
0.1
ps
0.1
dBm
27
6-66
6 Technical Parameters
Item
Unit
Parameter
Working temperature
5+55
6-67
6 Technical Parameters
Item
Unit
Parameter
Operating wavelength
range
nm
C-band: 15291561
L-band: 15701604
Supervisory channel in C-band: 15001520
Supervisory channel in L-band: 16151635
Insertion loss
INTC: 1.5
dB
INTL: 1.5
RCOUT: 1.5
RLOUT: 1.5
INTM: 1.8
INTMB: 1.8
RMOUT: 2.0
RMBOUT: 2.0
Isolation
IN to TM @ C: >40
dB
IN to TMB @ L: >40
IN to TC @ L: >35
IN to TL @ C: >40
Return loss
dB
>40
Directivity
dB
>55
Polarization dependent
loss (PDL)
dB
<0.1
6-68
6 Technical Parameters
6.11.2 ITL
The ITL provided by Huawei comply with related ITU-T recommendations. Its
parameters are shown in Table 6-63.
Table 6-63 Parameters of ITL
Item
Unit
Parameter
nm
C-band: 1529.161560.61
L-band: 1570.421603.57
GHz
100
GHz
50
Insertion loss
dB
<3
dB
<0.5
Isolation
dB
>25
Return loss
dB
>40
Directivity
dB
>55
ps
<0.5
dB
<0.5
dBm
23
Working temperature
555
Note1: Input and output is defined according to the multiplexing process of the ITL.
Instead of interleaver, coupler can be used for multiplexing to get 50 GHz channel
spacing system.
6-69
6 Technical Parameters
6.11.3 DGE
The parameters of the DGE module are shown in Table 6-64.
Table 6-64 Parameters of DGE
Item
Unit
Parameter
nm
15291561
dB
621
dB
<6
6.11.4 DSE
The parameters of the DSE board are shown in Table 6-65.
Table 6-65 Parameters of DSE
Item
Unit
Parameter
nm
15291570
dB
<3.0
6.11.5 MCA
The technical parameters of the MCA board are shown in Table 6-66.
Table 6-66 Parameters of MCA
Item
Unit
Parameter
nm
C-band: 15291561
L-band: 15701604
dB
1525
dBm
1030
dBm
0.5
OSNR accuracy
dB
1.5
nm
0.05
6-70
6 Technical Parameters
6.11.6 OSC
Table 6-67 OSC optical interface parameters
Item
Parameter
C band: 1500-1520
L band: 1615-1635
SC1/SC2
2.048 (Note 1)
TC1/TC2
8.192 (Note 1)
CMI
7 - 0
SLM
SC1/SC2
48
TC1/TC2
48
Note 1: When TC1/TC2 is used, up to three channels of clock can be transmitted in the system. So
the rate of OSC signal is 16Mbit/s on the line after CMI coding. Signal rate in the table is the rate
before CMI encoding.
6-71
6 Technical Parameters
6.12 DCM
Presently, different DCM types are available for both C and L bands. Their
parameters are shown in Table 6-68,Table 6-69 and Table 6-70.
Table 6-68 Performance requirement of dispersion compensation optical fiber of C-band (G.652 fiber)
Item
Distance
(km)
Max.
insertion
loss(dB)
DSCR
PMD (ps)
PDL
(dB)
Max. allow
power
(dBm)
Operation
wavelength
(nm)
DCM(A)
20
90%110%
0.4
0.1
20
15251565
DCM(B)
40
0.5
0.1
20
DCM(C)
60
0.6
0.1
20
DCM(D)
80
0.7
0.1
20
DCM(E)
100
0.8
0.1
20
DCM(S)
2.5
0.3
0.1
20
Type
DCM(S) is only used in the system with Super CRZ line encoding.
Table 6-69 Performance requirement of dispersion compensation optical fiber of L-band (G.652 fiber)
Item
Distance
(km)
Max.
insertion
loss(dB)
DSCR
PMD
(ps)
PDL
(dB)
Max. allow
power (dBm)
Operation
wavelength
(nm)
DCM(A)
20
90%110%
0.6
0.1
20
15701605
DCM(B)
40
5.3
0.9
0.1
20
DCM(C)
60
1.0
0.1
20
DCM(D)
80
8.4
1.0
0.1
20
Type
Table 6-70 Performance requirement of dispersion compensation optical fiber of C-band (G.655 LEAF
fiber)
Item
Distance
(km)
Max.
insertion
loss(dB)
DSCR
PMD (ps)
PDL
(dB)
Max. allow
power (dBm)
Operation
wavelength
(nm)
DCM(A)
20
90%110%
0.4
0.3
24
15251565
DCM(B)
40
0.5
0.3
24
DCM(C)
60
0.6
0.3
24
DCM(D)
80
0.7
0.3
24
DCM(E)
100
0.8
0.3
24
Type
6-72
6 Technical Parameters
Central frequency
(THz)
Central wavelength
(nm)
196.05
1529.16
194.05
1544.92
196.00
1529.55
194.00
1545.32
195.95
1529.94
193.95
1545.72
195.90
1530.33
193.90
1546.12
195.85
1530.72
193.85
1546.52
195.80
1531.12
193.80
1546.92
195.75
1531.51
193.75
1547.32
195.70
1531.90
193.70
1547.72
195.65
1532.29
193.65
1548.11
195.60
1532.68
193.60
1548.51
195.55
1533.07
193.55
1548.91
195.50
1533.47
193.50
1549.32
195.45
1533.86
193.45
1549.72
195.40
1534.25
193.40
1550.12
195.35
1534.64
193.35
1550.52
195.30
1535.04
193.30
1550.92
195.25
1535.43
193.25
1551.32
195.20
1535.82
193.20
1551.72
195.15
1536.22
193.15
1552.12
195.10
1536.61
193.10
1552.52
195.05
1537.00
193.05
1552.93
195.00
1537.40
193.00
1553.33
194.95
1537.79
192.95
1553.73
194.90
1538.19
192.90
1554.13
194.85
1538.58
192.85
1554.54
194.80
1538.98
192.80
1554.94
6-73
6 Technical Parameters
Central frequency
(THz)
Central wavelength
(nm)
194.75
1539.37
192.75
1555.34
194.70
1539.77
192.70
1555.75
194.65
1540.16
192.65
1556.15
194.60
1540.56
192.60
1556.55
194.55
1540.95
192.55
1556.96
194.50
1541.35
192.50
1557.36
194.45
1541.75
192.45
1557.77
194.40
1542.14
192.40
1558.17
194.35
1542.54
192.35
1558.58
194.30
1542.94
192.30
1558.98
194.25
1543.33
192.25
1559.39
194.20
1543.73
192.20
1559.79
194.15
1544.13
192.15
1560.20
194.10
1544.53
192.10
1560.61
6-74
6 Technical Parameters
Table 6-72 L-band channel allocation (80 channels with 50 GHz spacing)
Central frequency
(THz)
Central wavelength
(nm)
Central frequency
(THz)
Central wavelength
(nm)
190.90
1570.42
188.90
1587.04
190.85
1570.83
188.85
1587.46
190.80
1571.24
188.80
1587.88
190.75
1571.65
188.75
1588.30
190.70
1572.06
188.70
1588.73
190.65
1572.48
188.65
1589.15
190.60
1572.89
188.60
1589.57
190.55
1573.30
188.55
1589.99
190.50
1573.71
188.50
1590.41
190.45
1574.13
188.45
1590.83
190.40
1574.54
188.40
1591.26
190.35
1574.95
188.35
1591.68
190.30
1575.37
188.30
1592.10
190.25
1575.78
188.25
1592.52
190.20
1576.20
188.20
1592.95
190.15
1576.61
188.15
1593.37
190.10
1577.03
188.10
1593.79
190.05
1577.44
188.05
1594.22
190.00
1577.86
188.00
1594.64
189.95
1578.27
187.95
1595.06
189.90
1578.69
187.90
1595.49
189.85
1579.10
187.85
1595.91
189.80
1579.52
187.80
1596.34
189.75
1579.93
187.75
1596.76
189.70
1580.35
187.70
1597.19
189.65
1580.77
187.65
1597.62
189.60
1581.18
187.60
1598.04
189.55
1581.60
187.55
1598.47
6-75
6 Technical Parameters
Central frequency
(THz)
Central wavelength
(nm)
Central frequency
(THz)
Central wavelength
(nm)
189.50
1582.02
187.50
1598.89
189.45
1582.44
187.45
1599.32
189.40
1582.85
187.40
1599.75
189.35
1583.27
187.35
1600.17
189.30
1583.69
187.30
1600.60
189.25
1584.11
187.25
1601.03
189.20
1584.53
187.20
1601.46
189.15
1584.95
187.15
1601.88
189.10
1585.36
187.10
1602.31
189.05
1585.78
187.05
1602.74
189.00
1586.20
187.00
1603.17
188.95
1586.62
186.95
1603.57
Central
frequency (THz)
Central
wavelength (nm)
Central
frequency (THz)
Central
wavelength (nm)
192.1
1560.61
195.1
1536.61
192.3
1558.98
195.5
1533.47
192.6
1556.55
195.8
1531.12
193.0
1550.92
196.0
1529.55
Central
frequency (THz)
Central
wavelength (nm)
Central
frequency (THz)
Central
wavelength (nm)
192.1
1560.61
194.0
1545.32
192.2
1559.79
194.1
1544.53
192.4
1558.17
195.3
1535.04
192.8
1554.94
195.7
1531.90
193.0
1550.92
195.9
1530.33
193.1
1552.52
196.0
1529.55
6-76
6 Technical Parameters
IEC6100042
IEC6100044
IEC6100046
IEC6100043
Surge:
IEC6100045
IEC61000429 (DC)
ITU K.20
IEC6100048
6-77
6 Technical Parameters
6-78
6 Technical Parameters
Item
Range
Altitude
5000 m
Air pressure
70 kPa106 kPa
Temperature
40C+70C
1C /min
Relative Humidity
10%100%
Solar radiation
1120 W/s
Heat radiation
600 W/s
Wind speed
30 m/s
2. Waterproof Requirement
(1) Equipment storage requirements at the customer site: Generally the equipment is
stored indoors,
(2) Where there is no water on the floor and no water leakage on the packing boxes
of the equipment. The equipment should not be stored in places where leakage is
probable, such as near the auto firefighting and heating facilities.
(3) If the equipment is required to be stored outdoors, the following four conditions
should be met at the same time:
Necessary rainproof measures should have been taken to prevent rainwater from
entering the packing boxes.
There is no water on the ground where the packing boxes are stored, let alone
Huawei Technologies Proprietary
6-79
6 Technical Parameters
3. Biologic Environment
Content
Suspending dust
5.00 mg/m
Precipitable dust
20.0 mg/mh
Sand
300 mg/m
(3) The density of chemical active substance complies with the requirements of Table
6-77.
Table 6-77 Requirements for the density of chemical active substance
Content
SO2
0.30 mg/m
H2S
0.10 mg/m
NO2
0.50 mg/m
NH3
1.00 mg/m
CI2
0.10 mg/m
HCI
0.10 mg/m
HF
0.01 mg/m
O3
0.05 mg/m
6-80
6 Technical Parameters
5. Mechanical Stress
Table 6-78 Requirements for mechanical stress
Item
Subitem
Sinusoidal
vibration
Displacement
7.0 mm
Acceleration
20.0 m/s
Frequency range
2 Hz9 Hz
9 Hz200 Hz
Impact response
spectrum II
250 m/s
Static load
5 kPa
Non-steady
impact
Range
Note:
Impact response spectrum: the curve of the maximum acceleration response
generated by the equipment under the stipulated impact motivation. Impact
response spectrum II indicates the duration of semi sinusoidal impact spectrum is
6ms.
Static load: The pressure from upside, that the equipment with package can endure
when the equipment is piled as per stipulation.
Item
Range
Altitude
5000 m
Air pressure
70 kPa106 kPa
Temperature
40C+70C
3C /min
Relative Humidity
10%100%
Solar radiation
1120 W/s
Heat radiation
600 W/s
Wind speed
30 m/s
2. Waterproof Requirement
6-81
6 Technical Parameters
3. Biologic Environment
Content
Suspending dust
No requirement
Precipitable dust
3.0 mg/mh
Sand
100 mg/m
(3) The density of chemical active substance complies with the requirements of Table
6-81.
Table 6-81 Requirements for the density of mechanical active substance
Content
SO2
0.30 mg/m
H2S
0.10 mg/m
NO2
0.50 mg/m
NH3
1.00 mg/m
CI2
0.10 mg/m
HCI
0.10 mg/m
HF
0.01 mg/m
O3
0.05 mg/m
6-82
6 Technical Parameters
5. Mechanical Stress
Table 6-82 Requirements for mechanical stress
Item
Subitem
Sinusoidal vibration
Displacement
7.5 mm
Acceleration
20.0 m/s
40.0 m/s
Frequency range
2 Hz9 Hz
9 Hz200 Hz
200 Hz500 Hz
Acceleration spectrum
density
10 m/s
3 m/s
1 m/s
Frequency range
2 Hz9 Hz
9 Hz200 Hz
200 Hz500 Hz
Impact response
spectrum II
300 m/s
Static load
10 kPa
Random vibration
Non-steady impact
Range
Note:
Impact response spectrum: the curve of the maximum acceleration response generated by the
equipment under the stipulated impact motivation. Impact response spectrum II indicates the duration of
semi sinusoidal impact spectrum is 6ms.
Static load: The pressure from upside, that the equipment with package can endure when the
equipment is piled as per stipulation.
6-83
6 Technical Parameters
Equipment
name
Temperature
Relative humidity
Long-term
operation
Short-term
operation
Long-term
operation
Short-term
operation
0C40C
5C45C
10%90%
5%95%
Note:
Testing point of product temperature and humidity: when the cabinet of the
product has no protection board in the front and at the back, the value is
tested 1.5 meter above the floor and 0.4 meter in front of the cabinet.
Short-term working condition means that the successive working time does
not exceed 96 hours and the accumulated time every year does not exceed
15 days.
Item
Range
Altitude
4000 m
Air pressure
70106 kPa
5C /h
Solar radiation
700 W/s
Heat radiation
600 W/s
Wind speed
1 m/s
2. Biologic Environment
6-84
6 Technical Parameters
Content
Dust particle
3 105 /m
Suspending dust
0.4 mg/m
Precipitable dust
15 mg/mh
Sand
100 mg/m
(3) The density of chemical active substance complies with the requirements of Table
6-86.
Table 6-86 Requirements for the density of mechanical active substance
Content
SO2
0.20 mg/m
H2S
0.006 mg/m
NH3
0.05 mg/m
CI2
0.01 mg/m
HCI
0.10 mg/m
HF
0.01 mg/m
O3
0.005 mg/m
CO
5.0 mg/m
6-85
6 Technical Parameters
4. Mechanical Stress
Table 6-87 Requirements for mechanical stress
Item
Subitem
Sinusoidal vibration
Displacement
3.5 mm
Acceleration
10.0 m/s
Frequency range
29 Hz
9200 Hz
100 m/s
Static load
Non-steady impact
Range
Note:
Impact response spectrum: the curve of the maximum acceleration response
generated by the equipment under the stipulated impact motivation. Impact response
spectrum II indicates the duration of semi sinusoidal impact spectrum is 6ms.
Static load: The pressure from upside, that the equipment with package can endure
when the equipment is piled as per stipulation.
6-86
With the increasing transmission rate in the optical fiber system and the cascading of
multiple EDFA in the optical transmission system, the overall dispersion and related
dispersion costs in the transmission link will become higher. This is a serious issue. At
present, dispersion limitation has become a vital element in deciding many system
regeneration section distances. In the single module optical fiber, the dispersion
mainly includes material dispersion and wave-guide dispersion, which might cause
different time delays in different frequencies. In terms of time domain, this might lead
to the extension of optical pulses, which can cause the interference between optical
pulses. The result is the deterioration of transmitted signals.
3. Effect-Reducing Method
A-1
During the DWDM network design, the whole network is divided into several
regeneration sections. Each section should be less than the dispersion-restricted
distance of the optical source. Thus the dispersion of the whole network can be
tolerated.
Tips:
In dispersion calculation, for G.652 fibers, the typical dispersion coefficient in 1550 nm
window is 17 ps/nm.km. In engineering design, the budget should be 20 ps/nm.km.
A-2
S
P
out
R
P
L
Node B
in
If Pout is the output power (dBm) of a single channel at point S, and Pin is the minimum
allowed input power (dBm) of a single channel at point R, then
Regenerator distance = (Pout - Pin) /a
Where a is the accumulative attenuation of optical cables (dB/km) per km (according
to relevant ITU-T recommendation, a=0.275 dB/km).
Power budget calculations are used to determine distance between regeneration
sections.
A-3
The optical amplifier also generates the light signals with broad bandwidth, called
amplified spontaneous emission (ASE). In a transmission system with several
cascaded EDFAs, like original signals, ASE noise of the optical amplifier can be
attenuated and amplified. As the entered ASE noise is amplified in each optical
amplifier and is overlapped on ASE generated by the optical amplifier, the total ASE
noise power is increased in proportion to the number of optical amplifiers. The noise
power might be more than the signal power.
ASE noise spectrum distribution is changed with system length. When ASE noise
from the first optical amplifier is sent to the second optical amplifier, the gain
distribution of the second optical amplifier will cause ASE noise due to gain saturation,
which will cause gain distribution change. Similarly, the valid gain distribution of the
third optical amplifier will also be changed. This effect will be transmitted to the next
optical amplifier towards downstream. Even the implementation of narrow-band filter
cannot avoid this noise, because the noise exists in the same band in which the
original signal exists.
The optical signal-to-noise ratio (OSNR) is defined as:
OSNR =signal optical power per channel/noise optical power per channel
2. Transmission Restriction
ASE noise accumulation affects the systems OSNR, because the receiving signal
OSNR deterioration is mainly related to ASE beat noises. Beat noises are increased
linearly with the increase of optical amplifier number. Therefore, the error rate is
deteriorated together with the increase of optical amplifier number. In addition, noises
are accumulated as exponentially with the gain range of amplifiers.
As a result of optical amplifier gain, ASE noise spectrum with the accumulation of ASE
noises from multiple optical amplifiers will have a wavelength peak caused by the
spontaneous emission effect. It should be noted that in a closed full optical loop
network system equally to innumerable optical amplifiers are cascaded, ASE noises
will be infinitely accumulated. In the system with narrow band filters, the ASE
accumulation will be reduced due to the filter, but the in-band ASE will be increased
with the increase of optical amplifiers. Therefore, OSNR will be smaller for more
optical amplifiers.
3. Consideration of OSNR in DWDM Network Design
(Note: This section contains additional information. You may skip this section).
For different network applications, the OSNR requirements are more or less similar,
as given in Table A-1.
A-4
OSNR (dB)
5 20 dB system (5 72 km)
20
2 24 dB system (2 87 km)
20
20
A-5
A-6
B Technology Introduction
Technology Introduction
B.1 FEC
The optical wavelength conversion units have FEC (Forward Error Correction)
function or EFEC (Enhanced FEC) function.
In fact, the FEC technology is the error correction technology. The OTU adopts
Reed-Solomon Coding. It can correct eight bytes error at most in any location per 255
bytes, and has a fairly powerful capability of error correction. Due to redundancy
codes added, the digital rate is increased. All FEC employed in the OptiX BWS 1600G
is in compliance with ITU-T G.709 or G.975 recommendation and support the
processing of overhead comply with ITU-T G.709 recommendation.
The EFEC technology, compared with FEC, adopts much more predominant
encoding/decoding technology. Two-degree encoding/decoding can evenly distribute
the burst error code, and enable much more powerful error correction capability.
The FEC function can improve the OSNR budget of the DWDM transmission system
and increase the transmission distance. In addition, the FEC function can reduce bit
error rate in line transmission, and alleviate the bad effects on the signal transmission
quality caused by the aging components or deterioration of fiber performance, thereby
improving the communication quality of the DWDM transmission network.
B-1
B Technology Introduction
B.2 SuperWDM
1. Introduction
Improve the optical noise tolerance capability, increasing the receivers OSNR
tolerance by 3 dB (compared to NRZ encoding).
Effectively reduce the non-linear effects due to its adequate spectrum width and
special phase modulation technology.
B-2
B Technology Introduction
Gain
30nm
Fiber Raman amplifier is always used with the EDFA amplifier at the receiving end. It
adopts distributed amplification mechanism for extra long haul and extra long span
applications, as shown in Figure B-2.
Raman amplifier
Signal light
EDFA
Pump light
Fiber
Transmitting end
Pump light
Coupler
EDFA
Laser
Receiving end
Usually the optical fiber Raman amplifier is used at the receiving end of DWDM
system to amplify optical signals. Mainly composed of pumping lasers, the Raman
amplifier works in way of counter pumping.
B-3
B Technology Introduction
Note:
Counter pumping means the pump light is injected at the fiber end and the direction is
opposite to the main signals. This kind of pumping achieves a big phase difference
between the main signals and the pump light. And the Raman pump power vibration is
leveled in the direction reserved to signal transmission, thus effectively suppressing
the noise created by pump.
B-4
Abbreviations
Explanation in English
ADM
AGC
ALC
ALS
APE
APS
ASE
AWG
BA
Booster amplifier
BER
CLNS
CMI
CPU
CRC
CRZ
CSES
DCC
DCF
C-1
Explanation in English
DCM
DCN
DDN
DFB
Distributed feedback
DSP
DSCR
DWDM
ECC
EDFA
EFEC
ELH
EMC
Electromagnetic compatibility
ETSI
FEC
FWM
Four-wave mixing
GE
Gigabit Ethernet
GFF
GUI
IEEE
IPA
ITU-T
International Telecommunication
Union-Telecommunication Standardization Sector
LAN
LCN
LCT
LD
Laser diode
MCF
MD
Mediation device
MPI-R
MPI-S
C-2
Explanation in English
MQW
Multi-quantum well
NE
Network element
NF
Noise figure
NRZ
OA
Optical amplifier
OADM
OAM
OAMS
OD
Optical demultiplexing
ODF
OEQ
Optical equalizer
OHP
Overhead processing
OLA
OM
Optical multiplexing
OMS
ORL
OS
Operations system
OSI
OSNR
OTDR
OTM
OTS
OTT
OTU
PDH
PDL
PIN
PMD
POS
C-3
Explanation in English
RS
Reed-Solomon
RTU
QA
Q adaptation
SBS
SCC
SDH
SLIP
SLM
SONET
SPM
SRS
STM
Super CRZ
TCP/IP
TDM
TEC
Thermoelectric cool
TMN
TTL
Transistor-transistor logic
XPM
WDM
WS
Work station
C-4
Index
Index
channel spacing, 1-6
chromatic dispersion, A-1
clock extraction, 1-10
clock protection
with clock signal add/drop, 5-9
without clock signal add/drop, 5-9
clock transmission, 4-11, 4-12
clock transmission channel, 1-8, 1-9, 4-11
communication protocol
F interface, 2-25
Q3/Qx interface, 2-24
Qecc interface, 2-25
Numerics
1:N (N8) OTU protection, 5-7
1+1 line protection, 5-3
1+1 optical channel protection
client-side protection, 5-5
inter-OTU protection, 5-5
intra-OTU protection, 5-4
1+1 power hot backup, 5-1
A
abbreviation, C-1
access capacity, 1-1
amplified spontaneous emission, A-4
AP4
application and description, 2-13
optical interface parameter, 6-55, 6-56
automatic level control
channel amount detection, 4-9
reference power, 4-9
working principle, 4-8
automatic power equilibrium, 1-11, 4-10
D
D40
application and description, 2-14
parameter, 6-63
DCM
application and description, 2-19
C-band parameter for G.652 fiber, 6-72
C-band parameter for G.655 LEAF fiber, 6-72
L-band parameter for G.652 fiber, 6-72
DGE
application and description, 2-19
parameter, 6-70
dimension
cabinet, 2-2
subrack, 2-4
dispersion compensation, A-1
dispersion limitation, A-1
DSE
application and description, 2-19
parameter, 6-70
DWDM network design
dispersion consideration, A-2
OSNR consideration, A-4
signal power, A-3
DWDM network main optical path, 6-8
B
board
power consumption, 6-2
weight, 6-2
C
cabinet
dimension, 2-2
overview, 2-1
weight, 2-2
centralized power protection, 5-1
channel allocation
C-band, 6-73
C-band with 12-channel for G.653 fiber, 6-76
C-band with 8-channel for G.653 fiber, 6-76
L-band, 6-75
E
EC8
Index
HBA
application and description, 2-16
parameter, 6-30
M40
application and description, 2-14
parameter, 6-62
MB2
application and description, 2-15
parameter, 6-63
MCA
application and description, 2-19
parameter, 6-70
MR2
application and description, 2-15
parameter, 6-64
multi-channel spectrum analyzer, 1-12
MWA
application and description, 2-21
parameter, 6-66
MWF
application and description, 2-21
parameter, 6-66
F
fiber interface unit, 2-13
fiber management, 1-12
FIU
application and description, 2-14
parameter, 6-68
FMU
application and description, 2-21
parameter, 6-65
forward error correction, 1-7, 1-9, B-1
functional unit, 2-5
I
in-service monitoring, 1-11
intelligent power adjustment, 1-11, 4-9
interleaver unit, 2-13
ITL
application and description, 2-15
parameter, 6-69
J
jitter suppression, 1-10
L
LBE
application and description, 2-9
optical interface parameter, 6-41
LBES
application and description, 2-10
optical interface parameter, 6-41
LDG
application and description, 2-12
optical interface parameter, 6-49, 6-50
LGS
application and description, 2-13
optical interface parameter, 6-52, 6-53
long hop, 1-7
N
network element type, 3-1
network management, 1-8
network management channel
backup by DCN, 5-12
interconnection, 5-12
protection, 5-11
network management system, 1-13
networking
chain, 4-2
point-to-point, 4-2
ring, 4-2
Index
jitter generation, 6-61
jitter transfer characteristic, 6-60
list, 2-7
optical tunable transponder, 1-10
OPU
application and description, 2-16
parameter, 6-28
OSC
optical interface parameter, 6-71
OTT module parameter, 6-59
O
OAU
application and description, 2-16
CG/LG parameter, 6-24
CR/LR parameter, 6-25
OAU05, parameter, 6-26
OBU
application and description, 2-16
parameter, 6-27
OCP, application and description, 2-22
OCU
application and description, 2-11
optical interface parameter, 6-35
OCUS
application and description, 2-12
optical interface parameter, 6-37
OLP, application and description, 2-22
operation environment
air clarity, 6-84
biologic environment, 6-84
climate environment, 6-84
mechanical stress, 6-86
optical add/drop and multiplexing, 1-9, 2-13
optical add/drop multiplexer
configuration principle, 3-28
parallel OADM, 3-22
serial OADM, 3-21
signal flow, 3-21
typical configuration, 3-26
optical amplifier, 2-15
optical amplifier list, 2-15
optical automatic monitoring system
configuration plan, 4-15
monitor and test, 4-12
system architecture, 4-13, 4-16
optical channel protection, 5-3
optical demultiplexer, 2-13
optical equalizer
configuration principle, 3-38
signal flow, 3-32, 3-33
structure, 3-34
typical configuration, 3-36
optical equilibrium, 1-7
optical interface, 6-1
optical line amplifier
configuration principle, 3-19
signal flow, 3-15
structure, 3-16
typical configuration, 3-17
optical multiplexer, 2-13
optical multiplexer with VOA, 2-13
optical signal-to-noise ratio, 1-9, A-4
optical supervisory channel, 2-17
optical terminal multiplexer
configuration principle, 3-13
functional unit and board, 3-3
signal flow, 3-2
optical transponder unit
input jitter tolerance, 6-61
P
PBU, application and description, 2-22
performance monitoring and adjustment, 2-18
power backup, 1-12
power backup unit, 5-1
power consumption of board, 6-2
power protection. see also power backup
mutual DC input protection, 5-1
power supply, 6-1
protection
equipment-level unit, 1-12
optical channel, 1-12
optical line, 1-12
protection mechanism, 1-12
protection unit, 2-21
R
Raman amplifier
parameter, 6-31
working principle, B-3
Raman fiber amplification, 1-10
regenerator
configuration principle, 3-31
signal flow, 3-30
structure, 3-31
typical configuration, 3-31
remote optical pumping amplifier, 1-7
RPA,application and description, 2-17
RPC,application and description, 2-17
RPL,application and description, 2-17
S
SC1, application and description, 2-18
SC2, application and description, 2-18
SCC, application and description, 2-23
SCE, application and description, 2-23
SCS, application and description, 2-22
service type, 1-7
signal power budget, A-3
storage environment
air clarity, 6-80
biologic environment, 6-80
climate environment, 6-79
mechanical stress, 6-81
waterproof requirement, 6-79
subrack
dimension, 2-4
Index
C 800G main optical path parameter for G.655, 6-14
C 800G networking capability, 4-4
C+L 800G ELH main optical path parameter, 6-11
C+L 800G main optical path parameter, 6-10
C+L 800G networking capability, 4-4
capacity increment, 1-7
OADM structure, 3-25
OLA structure, 3-16
OTM structure, 3-6
transmission capacity, 1-7
typical OADM configuration, 3-27
typical OLA configuration, 3-18
typical OTM configuration, 3-10
upgrade, 1-7
type III system
capacity increment, 1-7
CRZ networking capability, 4-5
ELH transmission main optical path parameter, 6-17
G.653 fiber link networking capability, 4-5, 4-6
main optical path parameter, 6-16
main optical path parameter for 12-channel G.653
transmission, 6-19
NRZ networking capability, 4-5
OADM structure, 3-25
OLA structure, 3-16
OTM structure, 3-7
transmission capacity, 1-7
typical OADM configuration, 3-27
typical OLA configuration, 3-18
typical OTM configuration, 3-11
type IV system
capacity increment. see type III system capacity
increment
main optical path parameter for G.653 transmission,
6-20
networking capability, 4-6
OADM structure, 3-25
OLA structure, 3-16
OTM structure, 3-7
transmission capacity, 1-7
typical OADM configuration, 3-27
typical OLA configuration, 3-19
typical OTM configuration, 3-11
type V system
capacity increment, 1-7
main optical path parameter, 6-21
networking capability, 4-6
OADM structure, 3-25
OLA structure, 3-16
OTM structure, 3-7
transmission capacity, 1-7
typical OADM configuration, 3-27
typical OLA configuration, 3-18
typical OTM configuration, 3-11
type VI system
10-channel main optical path parameter, 6-22
40-channel main optical path parameter, 6-23
capacity increment, 1-7
networking capability, 4-7
OTM structure, 3-7
typical OTM configuration, 3-13
structure, 2-3
weight, 2-4
subrack structure
board area, 2-3
fan tray assembly, 2-4
fiber cabling area, 2-4
fiber spools, 2-4
front door, 2-4
interface area, 2-3
supervisory channel backup, 5-11
SuperWDM, 1-7, 1-10, B-2
system characteristic, 1-4
system classification, 1-4
system compatibility, 1-8
system control and communication unit, 2-22
system feature, 1-7
system software
board software, 2-25
NE software, 2-25
network management system, 2-26
system software architecture, 2-24
T
TC1, application and description, 2-18
TC2, application and description, 2-18
timing transporting unit, 2-17
TMX
application and description, 2-12
optical interface parameter, 6-38
TMXS
application and description, 2-12
optical interface parameter, 6-40
transmission restriction
dispersion limitation, A-1
OSNR limitation, A-4
transport environment
air clarity, 6-82
biologic environment, 6-82
climate environment, 6-81
mechanical stress, 6-83
waterproof requirement, 6-81
TRC, application and description, 2-10
TRC1, application and description, 2-10
tunable wavelength, 1-10
TWC
application and description, 2-11
optical interface parameter, 6-51
type I system
capacity increment, 1-7
main optical path parameter, 6-9
networking capability, 4-3
OADM structure, 3-24
OLA structure, 3-16
OTM structure, 3-5
transmission capacity, 1-7
typical OADM configuration, 3-27
typical OLA configuration, 3-17
typical OTM configuration, 3-8
upgrade, 1-7
type II system
C 800G main optical path parameter for G.652, 6-12
Index
WBA
application and description, 2-16
parameter, 6-29
weight
cabinet, 2-2
subrack, 2-4