Professional Documents
Culture Documents
Eclipse Grease Arrestor Fibreglass Manual
Eclipse Grease Arrestor Fibreglass Manual
Eclipse Grease Arrestor Fibreglass Manual
02 27 June 2005
Product manual
Capacity L
Eclipse GA1000F
Eclipse GA1500F
Eclipse GA2000F
Eclipse GA3000F
Eclipse GA4000F
Eclipse GA5000F
1000
1500
2000
3000
4000
5000
1
Page 1 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
PAGE
INTRODUCTION,
APPLICATIONS
SPECIFICATIONS
INSTALLATION INSTRUCTIONS
BELOW GROUND
ABOVE GROUND
MAINTENANCE INSTRUCTIONS
WARRANTY
8
9
DIMENSIONAL DRAWING
10
ENGINEERS CERTIFICATION
11
2
Page 2 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
INTRODUCTION.
Eclipse manufacture a range of boat shaped grease arrestors. These devices are used
for the removal of grease and food particles that are generated in the waste water of
all commercial cooking and food preparation areas.
The Eclipse range includes fibreglass units which are able to be installed above or
below ground.
They feature built in fibreglass legs which are able to support the grease arrestors.
The choice of lids are:
Below ground installation.
NB. Eclipse does not supply cast iron covers, these are available from many concrete
products supply companies. Icon industries and Mascot have a range of suitable
covers and supply the relevant technical information on the installation of their
products.
Arrangement of lids on the 1000 L, 1500 L, 2000 L, 3000 L grease arrestors.
Double lids to be installed on the outlet (deep) end of the grease arrestor.
For the 4000 L and 5000 L grease arrestor, double lids must be installed on both
ends.
3
Page 3 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
APPLICATIONS.
Businesses types suitable for the Eclipse Boat shaped arrestors include:
Bakery
Boarding house
Butchers
Cafe
Cafeteria
Canteen
Cheese Cake Shop (made on
premises)
Chicken shop (charcoal and
fresh)
Child Care Centre
Kebabs
Motel
Nightclub
Nuts
Pasta
Patisserie
Pavlova
Pies
Pizza
Restaurant
Salads
Sandwiches
School Canteen (cooking)
School Home Science
Seafood
Service Station Forecourt caravan
Ship to Shore (galley Waste)
Soup Kitchen
Take away Foods
Club
Coffee shop
Commercial kitchen
Community Hall
Defence Force Mess
Delicatessen
Dessert shop
Doughnut Shop
Fast food shop
Fish and chip Shop
Hot Bread
Yeeros (Yiros)
Function Centre
Hotel
Further requirements.
A dry basket arrestor is necessary if floor wastes are in food preparation and handling areas.
All trade waste water must pass through the grease arrestor.
4
Page 4 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Specifications:
Fibreglass boat shaped arrestor.
TANK MATERIAL
INTERNAL STRUCTURE
LID above ground
Volume L
Weight kg
Weight lid
kg
1000
90
12
2000
180
17
3000
280
21
4000
380
21
5000
500
25
Plumbing fittings.
The arrestors are fitted with pvc connections of the following sizes.
INLET
100 mm SWD (150 mm for 5000 litre arrestor)
OUTLET
100 mm SWD (150 mm for 5000 litre arrestor)
VENT
100 mm SWD
Quality Control for the manufacture of the fibreglass tank.
Resin type:
5
Page 5 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
INSTALLATION INSTRUCTIONS.
All installations should be carried out by a licensed plumber and comply with AS
3500. The boat shaped arrestor should be located so as not to impede access to
personal and consideration is given to the maintenance requirements.
Sydney Water require that a clearance above the arrestor be equal to the height of the
arrestor to facilitate the use of a sludge gauge.
Surcharge point.
The grease arrestor must not be used as a surcharge point. A gully or a reflux valve
must be installed downstream of the arrestor if this is the case.
Outlet from the grease arrestor.
The outlet level must be a minimum of 100 mm below the inlet invert level.
Plumbing fittings and pipes.
PVC pipes are preferred but cast iron is acceptable. Copper pipes must not be used.
Rubber adaptors are available for retrofitting PVC pipe to other types of pipes.
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
7
Page 7 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Maintenance instructions.
The grease arrestor must be pumped out and cleaned at the pumpout frequency set by
Sydney Water.
All grease arrestors should be pumped out every 3 months.
The grease arrestor must have its entire contents removed when it is serviced. Any
undersink unit or pump box must also be serviced at the same time.
The cleaning process includes:
1.
2.
3.
4.
Scraping the sides down as the contents are being pumped out.
The internal surfaces are hosed down
Wiping down the lids and any other pumpout connections etc.
Checking the operation of any pump boxes connected to the arrestor
8
Page 8 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Manufacturers Warranty
Eclipse grease arrestors manufactured by Eclipse Environmental Aust P/L are
guaranteed to be free from defects in materials and workmanship for 60 months from
the date of purchase.
The obligations under this warranty, statutory or otherwise, is limited to replacement
or repair at our factory in Sydney or another depot designated by us, of such
component that we believe to be faulty or defective.
This warranty does not include freight to and from our factory or depot.
No expressed, implied or statutory warranty other than herein is made by Eclipse
Environmental Aust. P/L.
In no event shall Eclipse Environmental Aust. P/L be liable for consequential
damages or contingent liabilities arising out of the failure of any component supplied
by us.
Compliance plate.
The grease arrestors have a compliance plate made from metallic film with plastic
substrate mounted next to the outlet pipe in the above ground unit and internally near
the top on the outlet side of the below ground unit.
The plate is 100 mm by 50 mm in size and is attached with polyurethane adhesive.
9
Page 9 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
10
Page 10 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
11
Page 11 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
12
Page 12 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
13
Page 13 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
14
Page 14 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
15
Page 15 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005
16
Page 16 of 16 Eclipse boat shaped grease arrestor (fibreglass) rev 1.02 27 June 2005