Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Gas Valve Sizing Calculation

Prepared For: OME International


Prepared By: Carlos Sandoval
Kimray Valve: E1HPPR 3/8" IV / Viton Elastomers / D2 Seat / Carbide Ball / 30 HPG Pilot with Sense Line Protector
Trim Size: 3/8"
Fluid: GAS
Comments:

Gas Specific Gravity (G) = 0.6000


Flowing Temperature (T, Deg F) = 100.0000
Upstream Pressure (Pu, psig) = 450.0000
Downstream Pressure (Pd, psig) = 210.0000
Critical Flow Factor (Cf) = 0.6200
Flow Rate (Q, MMCF) = 0.2800
Valve Flow Coefficient (Cv) = 0.8895
The capacity was derived using the following formula:
Flow Rate Equation:
Valve Flow Coefficient:

Where:

2 HPMV REGULATOR DIMENSION


BACK PRESSURE AND PRESSURE REDUCING

KIMRAY, Inc.

HIGH PRESSURE REGULATORS


PRESSURE REDUCING REGULATOR
300 psi Maximum Output Pressure

Assembly includes the following equipment:


2 NPT High Pressure Motor Valve with EP Trim
DP 400 Drip Pot with Bracket
12 SGR Supply Gas Regulator
30 HPG Pilot

Okla. City, OK

You might also like