A revolution is taking place in Fire Suppression. Developed from solid
rocket fuel technology, Pyrogen is the world's first commercially available
Aerosol Fire Extinguishing System. Designed as a safe & practical
alternative to Halon, Halocarbons, Chemical Powders and Inert Gases
Pyrogen is available from stock in a wide range of canister sizes. Pyrogen
is an inert non-toxic solid that remains stable until electrically or thermally
activated, where upon it produces a gas-like extinguishing aerosol. The
aerosol attacks the fire chemically and physically, giving virtual instant
extinguishment & preventing re-ignition, and in certain instances,
explosions. For many applications Pyrogen is the only practical
alternative to Halon.
l and military
air
rcia
e
cra
m
m
ft
co
re
da
-s
off
ho
ta roo ms
Benefits of Pyrogen
HALON
HALON
HALON
PYROGEN
PYROGEN
Halon1301
FM-200
FE-13
CO2
Inert gas
Recommended maximum for Class A, B, C, E & F type fires. Refer to table on reverse.
TE DS TE D
TE S TE TESTED
Low Toxicity.
Cost Effective
d automation e
qui
y an
r
e
pm
n
i
h
en
c
a
t
m
plant
ma
ch
i
ry
ne
How it works
Canister construction
Electrical signal
fromcontrol panel
Chemical coolantdecomposesabsorbingheat
Canisterheated500 C
Nakedflamevia
pyrotechnicfuse
Nakedflameor
o
heat175 Cvia
fireconductingcord
Firefightingaerosol rapidlygenerated
Aerosol generated
Decomposedchemical coolant
Aerosol distributed
O2 O2 O2
O2 O2 O2
K
O H OH
HEAT
Stage 1
Fire is propagated by the
'flame chain carriers' O, H & OH
FUEL
(CnHm)
FUEL
(CnHm)
shipp
ing
an
d
es
ts
icl
ic al c a bin e
eh
ctr
ry
ilit a
Stage 3
K radicals attach themselves to O, H & OH
and remove them from the flame chain
without depleting Oxygen
Stage 2
Pyrogen aerosol introduces potassium
radicals (K) into the flame chain reaction
ine
ar
m
le
Flamechainbroken
H OH
HEAT
K
Pyrogen
FUEL
(CnHm)
Technical data
Canister Characteristics
Canister Material:
Surface Treatment:
Max/Min Ambient
Shock:
Vibration:
Corrosion Resistance:
Impact Resistance:
Humidity:
Supervision/Monitoring Circuit:
Activation (Electrical):
Activation (Thermal):
Connector:
Aerosol Characteristics
Classifications
~ 7g/m3
~ 70% by vol.
~ 1.2% by vol
~ 0.4% by vol
40 100 ppm
~ 0.075% by vol
_< 75C
17% to 20% (typical)
_< 60 mins
_<1mA
_>400mA @6/12/24v for 10mS
_>175C
4 pin Military Type 2 PMDT
Analog MIL-C-5015
Packaging Group:
Comparison table
Agent
Formula
TOXICITY
ODP
PYROGEN
KNO 3
Plasticised Nitrocellulose
Carbon
Admixtures
CBrF3
CF 3CHFCF 3
CHCI 2CF 3
CHCIF 2
CHCIFCF 3
CHF 3
CHF 2CF 3
N2
Ar
Ar
N2
Ar
CO 2
CO 2
H2O
62.3%
12.7%
9%
16%
LOW*
LOW
LOW
LOW
10
0
0.036
5600
2900
1450
65
36.5
12
5
7
11.9
330
530
530
Chemical
physical
physical
LOW
LOW
LOW
0
0
0
11700
2800
0
264
32.6
0
16-18
10.9
33.6
470
580
600
physical
physical
physical
LOW
LOW
0
0
0
0
0
0
38
37.5
500
500
physical
physical
HIGH
NIL
LOW
0
0
0
-0
0
-0
0
50
---
900
-1400-1800
Halon 1301
FM-200
NAF S III
FE-13
FE-25
Argonite
Argotec
Inergen
Carbon dioxide
Water
Chemical powders
4.75%
82%
9.5%
50%
50%
100%
52%
40%
8%
100%
Atmospheric
GWP
(100yrs vs lifetimes (yrs)
CO2 =1)
0
0
Extinguishing concentration
(Class B fires)
%v.v.
g/m 3
--100
Mechanism of
fire suppression
chemical
physical
physical
chemical or physical
* Pyrogen has been certified as low toxicity by the Academy of Science & Biophysics Institute, Moscow.
off
ro
eng
ine
icles
veh
ad
ys
ba
bu
s and hgv
Installation data
Available sizes
Parameter
Mass of generator, g
Mass of aerosol forming
composition, g
Max protected volume, m3
@ 100g/m3
Nozzle outlet
Length, mm
Diameter, mm
Discharge time, sec
MAG-02 MAG-1
110
400
20
60
0.2
bi120
25
<2.0
0.6
mono80
75
<3.0
MAG-2
500
100
MAG-3
700
200
MAG-4
4,500
1,000
1
mono95
75
<5.0
2
mono145
75
<7.0
10
bi350
95
<10.0
5
mono190
95
<8.0
12
mono180
247
<12.0
17
mono247
247
<12.0
27
mono235
306
<15.0
46
mono260
402
<15.0
50
mono175
492
<15.0
65
mono227
492
<15.0
85
mono285
492
<15.0
Pyroshield
Pyroshield (UK)
Fire panels
Accessories
Pyroshield Ltd.
tra
i
ansportati
d tr
on
n
a