Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

D-1

C-5
D-5
G-5
C-9
D-9
G-9

B-2

B-11

G-12

H-12

A-11

A-2

A.0-11.4

A.4-11.2

A.2-15

A-4

MARKS

A.4-15

A-10
E-14
F-14
H-14

FLOOR
C
LCOLUMN

HSS POST SEE PLAN

PLATE " W/

STIFF./CONN.}"

4-"$ BOLTS

EACH SIDE

TYP.

S3.01

10'-0"

STAIR ROOF

TYP.
5

3-SIDES

S3.01

ROOF

PLATE " W/
4-"$ BOLTS

14'-0"

W12x40

W12x40

SEE SCHEDULE

W12x45

W12x40

COLUMN -

W12x40

5
W12x40

4TH FLOOR

14'-0"

DETAIL
4

S3.01

14'-0"

1'-8"

W12x40

W12x53

W12x65

W12x96

W12x53

C
L

W12x53

3RD FLOOR

CONNECTOR
VESTIBULE
T/STEEL

PARTIAL
PENETRATION

2ND FLOOR

75%

LOCATION
OF SPLICE

COLUMN FIELD SPLICE DETAIL

C
LCOLUMN

STIFF./CONN.}"

PARTIAL PENETRATION

C
LCOLUMN

NOTES:

BASE PLATE
SEE 1/S3.01
(U.N.O.)

SEE 1/S5.02

2'-0"
U.N.O.

1ST FLOOR
T/FTG.

16'-8"

12'-0"

W10x33

W10x68

W12x40

W12x40

4'-0"

T/STEEL

W10x33

CONNECTOR

1. SEE PLANS FOR STUB COLUMNS & COLUMNS NOT SHOWN.

SEE

2. SEE MOMENT FRAME ELEVATIONS FOR MOMENT FRAME COLUMN SIZES.

1/S5.02

C
L COLUMN

EACH SIDE

COLUMN-

TYP.

SEE SCHED.

P
L"w/4-"

TYP. EA.
FLANGE

Dia. BOLTS

GIRDER/BEAM
SEE PLAN

3-SIDES

dia. BOLTS

1.5 x ROD $

"C"

STIFFENER

COLUMN-SEE PLAN

AT END COL.

TO MATCH COL. WEB.

TYP.

OR SCHEDULE

3-SIDES

AT INTERMEDIATE COL.

EA. SIDE

"D2"

W3

C
L

"D1" "D1"

C
L COLUMN

C
L

"D1"

"D1"

"D1""D1"

TYP. EA.

STIFF./CONN.}"
EACH SIDE

W2

WEB ON WEB BEARING

STRONG AXIS

C
LCOLUMN

C
L

"C"

"D2"

"D2" "D2"

"B"

HOLE DIA.=

C
L BASE PL
& COLUMN

1.5 x ROD $

"C"
W2

1.5 x ROD $

C
L BASE PL
& COLUMN

"D2""D2"

PL 1" w/ 4-"

HOLE DIA.=

"B"

TYP.

C
L BASE PL
& COLUMN

"B"

HOLE DIA.=

C
LCOLUMN

FLANGE

COLUMN-

TYP.

TYPE I

SEE SCHED.

P
L"w/4-"

COLUMN
SIZE

BASE PLATE

ANCHOR RODS

TYPE I
I

TYPE I
II

WELDS
TYPE

No. DIA. EMBED.

D1

D2

7"

7"

W1

W2

W3

"

"

"

"

"

Dia. BOLTS
GIRDER/BEAM

18"

W12x40

1"

20"

20"

8"

8"

W12x53

1"

20"

20"

8"

8"

1"

12"

"

W12x65

1"

20"

20"

8"

8"

1"

12"

"

W12x96

2"

20"

20"

8"

8"

1"

12"

"

"

dia. BOLTS

12"

"

GROUT + BASE PLATE THICKNESS +


ANCHOR ROD DIA. + 2" MIN.
GROUT
(FLOWABLE)

1"

14"

14"

5"

5"

1"

12"

"

III

STIFFENERP
L EA. SIDE
TO MATCH COL. WEB.

5
TYP.
3-SIDES

OR SCHEDULE

AT END COL.

THREADED ANCHOR ROD PROJECTION=

DIA.

COLUMN-SEE PLAN

PERPENDICULAR WEB BEARING

BEAM TO COLUMN CONNECTION


FOR CONTINUOUS BEAMS

BASE PLATE & ANCHOR ROD SCHEDULE

SECTION-COLUMN BEARING ON

TRANSFER GIRDER/BEAM

HEADED ANCHOR RODS w/2 HEAVY HEX


NUTS & 2 " SQUARE PLATE WASHERS
(TYP.) WASHER SIDE DIMENSION=
2 x ROD DIA.

Nashville, TN 37203
615.244.7399 t
615.244.6697 f
lddi-architects.com

ATLANTA
NASHVILLE
TAMPA

REV

REV

REV

REV

REV

REV

14
71
01
Structural Design Group
220 Great Circle Road, Suite 106
Nashville, Tennessee 37228
p. 615.255.5537
f. 615.255.1486

SDG Project No. 2013-124.00

HCA Inc.

South State Street


Draper, Utah 84020

TITLE STEEL COLUMN SCHEDULE


AND DETAILS

STATUS PERMIT SET

AT INTERMEDIATE COL.

WEAK AXIS

1"

HSS5x5

W1

"A"

3-SIDES

PL 1" w/ 4-"

2"

EMBED.

STRUCTURAL DESIGN GROUP


17-JAN-2014 13:14
stuartd
S:\Sdg-dgn\Projects\2013\2013-124\cad\S301.dgn

12"

1"

SEE PLAN

TYP.

18"

1"

W10x33

209 10th Avenue South


Suite 327, Cummins Station

NON-MOMENT FRAME COLUMNS

JOB 213030.00
QC

DRAWN

JP

CSD

S 3.01
DATE 01/17/14

April 9 2014 - Original

C-1

H-3

Speci
al
t
y Cent
r
e

G-3

D-13

Lone Peak

C-13

THI
S DRAW I
NG I
S THE PROPERTY OF LYM AN DAVI
DSON DOOLEY I
NCORPORATED ARCHI
TECTS. I
TI
S NOT TO BE REPRODUCED I
N W HOLE OR I
N PART. I
TI
S NOT TO BE USED ON ANY OTHER PROJECT. I
T SHALL BE RETURNED UPON REQUEST. COPYRI
GHT AS DATED LYM AN DAVI
DSON DOOLEY. NOT VALI
D UNLESS SI
GNED AND SEALED.

COLUMN SCHEDULE