G5LE- @ @@
1 2 3
1. Number of Poles
1: 1-pole
2. Contact Form
None: SPDT (1c)
A:
SPST-NO (1a)
Home appliances
OA equipments
Vending machines
3. Enclosure rating
None: Flux protection
4:
Fully sealed
G
5
L
E
Ordering Information
Characteristics
Flux protection
Fully sealed
Minimun
Rated coil
Rated coil
packing unit
Model
Model
Classification Contact form
voltage
voltage
5 VDC
5 VDC
SPDT (1c)
G5LE-1
12 VDC G5LE-14
12 VDC
24 VDC
24 VDC
100 pcs/
Standard
tray
5 VDC
5 VDC
SPST-NO (1a) G5LE-1A 12 VDC G5LE-1A4 12 VDC
24 VDC
24 VDC
Enclosure rating
Terminal
Shape
PCB
terminals
Note. When ordering, add the rated coil voltage to the model number.
Example: G5LE-1 DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked
as @@ VDC.
Ratings
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between
coil and
contacts
Dielectric
Between
strength
contacts of
the same
polarity
Impulse
between
withstand coil and
voltage
contacts
Destruction
Vibration
resistance
Coil
Malfunction
Rated
voltage
Rated
current
(mA)
Coil
resistance
()
5 VDC
12 VDC
24 VDC
79.4
33.3
16.7
63
360
1,440
Power
consumption
(mW)
170%
at 23C
Approx. 400
75% max.
10% min.
Shock
resistance
Destruction
Malfunction
Mechanical
Durability
Electrical
100 m max.
10 ms max.
5 ms max.
100 M min.
2,000 VAC, 50/60 Hz
for 1 min
750 VAC, 50/60 Hz
for 1 min
4,500 V (1.250 s)
10 to 55 to 10 Hz,
0.75 mm single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz,
0.75 mm single amplitude
(1.5 mm double amplitude)
1,000 m/s2
100 m/s2
10,000,000 operations min.
(at 18,000 operations/hr)
100,000 operations min.
(at 1,800 operations/hr)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance
of 10%.
2. The operating characteristics are measured at a coil temperature of 23C.
3. The Max. voltage is the maximum voltage that can be applied to the relay coil.
100 mA at 5 VDC
Ambient operating
temperature
-25C to 85C
(with no icing or
condensation)
Contacts
Ambient operating
humidity
Weight
Item
Load
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Resistive load
Single
Ag-alloy (Cd free)
10 A at 120 VAC; 8 A at 30 VDC
5 A at 120 VAC; 4 A at 30 VDC
10 A
250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied)
10 A
5A
35% to 85%
Approx. 12 g
G5LE
Engineering Data
Durability
50
30
AC resistive
load
AC inductive
(cos 0.4)
10
7
5
3
500
300
30 VDC
resistive load
100
70
50
120 VAC
resistive load
30
200
180
160
140
1
0.7
0.5
10
7
5
DC resistive
load
0.3
120
10
30
50
100
500 1,000
100
10
0
25
12
20
30
40
50
60
70
80
90 100
Shock Malfunction
NO contact
1,000
NC contact
G
5
L
E
1,000
X
1,000
Z
500
Z Y
500
Z
1,000
X
1,000
Y
X
X
1,000
Unit: m/s
Shock direction
Dimensions
G5LE-1
G5LE-1A
(21.6)*
22.5 max.
Terminal Arrangement/
Internal Connections
(Bottom View)
(15.6)*
16.5 max.
SPDT (1c)
SPDT (1c)
Five,1.3+0.2
0 dia. holes
(18.56)*
19.0 max.
(2.25)
0.5
12
3.5
0.2
1.2
*Average value
0.4
12.2
(2.55) 2
(5.75)
(2.25)
G5LE-14
G5LE-1A4
(21.6)*
22.5 max.
(15.6)*
16.5 max.
SPST-NO (1a)
SPST-NO (1a)
Four,1.3+0.2
0 dia. holes
(2.25)
(18.5)*
19.0 max.
12
0.5
3.5
12.2
0.2
1.2
*Average value
0.4
(2.55) 2
(5.75)
(2.25)
G5LE
Approved Standards
UL Recognized:
Model
Contact form
Coil
ratings
Contact ratings
G5LE
SPDT-NO (1a)
SPDT (1c)
5 to
24 VDC
10 A, 250 VAC
(general use) at 40C
8 A, 30 VDC
(resistive load) at 40C
TV-3 (N.O only) 40C
CSA Certified:
Model
G5LE
Contact form
SPDT-NO (1a)
SPDT (1c)
Model
Contact form
G5LE
SPDT-NO (1a)
SPDT (1c)
Coil
ratings
Contact ratings
5 to
24 VDC
10 A, 250 VAC
(general use) at 40C
8 A, 30 VDC
(resistive load) at
40C
TV-3 (N.O only) 40C
25,000
Contact form
SPDT-NO (1a)
SPDT (1c)
Number of test
operations
6,000
25,000
Coil
ratings
5, 12, 24
VDC
TV EN/IEC Certified:
G5LE
6,000
Model
Number of test
operations
Contact ratings
10 A, 250 VAC
(cos = 1) 85C
Number of test
operations
50,000
Coil
ratings
Contact ratings
5, 12, 24
VDC
Number of test
operations
G
5
L
E
100,000
50,000
100,000
Precautions
Please refer to PCB Relays Common Precautions for correct use.
G5LE
G
5
L
E
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb