Professional Documents
Culture Documents
Kathrein 80010666
Kathrein 80010666
Dual Polarization
Half-power Beam Width
Adjust. Electr. Downtilt
790 960
1710 2690
65
65
010
0 6
set by hand or by optional RCU (Remote Control Unit)
80010666
Type No.
Frequency range
Polarization
Average gain (dBi)
Tilt
Horizontal Pattern:
Half-power beam width
Front-to-back ratio, copalar
(18030)
Cross polar ratio
Maindirection
0
Sector
60
Vertical Pattern:
Half-power beam width
Electrical tilt
Min. sidelobe supression for
rst sidelobe above main beam
Impedance
VSWR
Isolation: Intrasystem
Isolation: Intersystem
Intermodulation IM3
Max. power per input
Total power
790 960
1710 2690
790 866 MHz
824 896 MHz
880 960 MHz 1710 1880 MHz 1850 1990 MHz 1920 2170 MHz 2490 2690 MHz
+45, 45
+45, 45
+45, 45
+45, 45
+45, 45
+45, 45
+45, 45
16.8 ... 16.7 ... 16.5 17.0 ... 17.0 ... 16.8 17.1 ... 17.2 ... 17.0 18.5 ... 18.4 ... 18.1 18.5 ... 18.4 ... 18.1 18.8 ... 18.7 ... 18.2 18.2 ... 18.3 ... 18.0
0.5 ... 5 ... 9.5 0.5 ... 5 ... 9.5 0.5 ... 5 ... 9.5
0 ... 3 ... 6
0 ... 3 ... 6
0 ... 3 ... 6
0 ... 3 ... 6
68
67
65
62
63
62
63
> 25 dB
Typically:
> 24 dB
> 10 dB
> 25 dB
Typically:
> 23 dB
> 10 dB
> 25 dB
Typically:
> 22 dB
> 10 dB
> 25 dB
Typically:
> 18 dB
> 10 dB
> 25 dB
Typically:
> 22 dB
> 10 dB
> 25 dB
Typically:
> 23 dB
> 10 dB
> 25 dB
Typically:
> 25 dB
> 10 dB
7.5
7.4
7.1
4.5
4.4
4.1
3.5
0.59.5, continuously adjustable
06, continuously adjustable
0 ... 3 ... 6 T
0 ... 3 ... 6 T
0 ... 3 ... 6 T
0.5 ... 5 ... 9.5 T 0.5 ... 5 ... 9.5 T 0.5 ... 5 ... 9.5 T 0 ... 3 ... 6 T
18 ... 16 ... 14 dB 18 ... 17 ... 15 dB 18 ... 18 ... 16 dB 17 ... 16 ... 16 dB 18 ... 18 ... 17 dB 18 ... 17 ... 17 dB 18 ... 18 ... 17 dB
50
< 1.5
> 30 dB
> 28 dB
> 30 dB (790960 // 17102690 MHz)
< 150 dBc (2 x 43 dBm carrier)
500 W (at 50 C ambient temperature)
200 W (at 50 C ambient temperature)
1000 W (at 50 C ambient temperature)
400 W (at 50 C ambient temperature)
790960
45
790960
+45
17102690
45
17102690
+45
7-16
7-16
7-16
7-16
65
7.4
dB
dB
10
10
Vertical Pattern
010 electrical downtilt
62
Mechanical specifications
Input
Connector position
Adjustment
mechanism
Wind load
4.0
1
0
10
dB
dB
936.4069/b
Subject to alteration.
Horizontal Pattern
3
0
Horizontal Pattern
www.kathrein.de
Vertical Pattern
06 electrical downtilt
80010666 Page 1 of 2
KATHREIN-Werke KG Anton-Kathrein-Strae 1 3 P.O. Box 10 04 44 83004 Rosenheim Germany Phone +49 8031 184-0 Fax +49 8031 184-973
Accessories
General Information
Accessories
Weight
approx.
1 clamp
1.1 kg
1 clamp
1 clamp
1 downtilt kit
2.7 kg
4.8 kg
6.5 kg
Description
738546
85010002
85010003
85010008
Remarks
Type No.
72
64
Material:
Grounding:
The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
2622
2652
2692
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
Low temperature: 55 C
High temperature (dry): +60 C
Ice protection: Due to the very sturdy antenna construction and the
protection of the radiating system by the radome, the antenna remains
operational even under icy conditions.
Environmental tests:
Adjustment mechanism
with integrated scale
49
46
108
173*
152*
Layout of interface:
101
221
As a result of more stringent legal regulations and judgements regarding product liability, we are
obliged to point out certain risks that may arise when products are used under extraordinary operating
conditions.
The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby
respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are
calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional
dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or
even cause it to fall to the ground. These facts must be considered during the site planning process.
The installation team must be properly qualified and also be familiar with the relevant national safety
regulations.
The details given in our data sheets have to be followed carefully when installing the antennas and
accessories.
The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must
be obeyed.
Any previous datasheet issues have now become invalid.
Page 2 of 2 80010666
www.kathrein.de
KATHREIN-Werke KG Anton-Kathrein-Strae 1 3 P.O. Box 10 04 44 83004 Rosenheim Germany Phone +49 8031 184-0 Fax +49 8031 184-973
Subject to alteration.
Please note:
Bottom view
* Dimensions refer to radome
936.4069/b
244
300*