Electrical data Multi-turn actuators for modulating duty

with 3-phase AC motors


Intermittent duty S4 - 25 %, 400 V/50 Hz
Type

Multi-turn actuator
Speed
Torque

SAR 07.2

SAR 07.6

SAR 10.2

SAR 14.2

SAR 14.6

SAR 16.2

rpm
4
5.6
8
11
16
22
32
45
63
90
4
5.6
8
11
16
22
32
45
63
90
4
5.6
8
11
16
22
32
45
63
90
4
5.6
8
11
16
22
32
45
63
90
4
5.6
8
11
16
22
32
45
63
90
4
5.6
8
11
16
22
32
45
63
90

Motor
Type

max. Nm

30

60

120

250

500

1,000

SAR 07.2 SAR 16.2

VD0R063-4-0,02
VD0R063-4-0,02
VD0R063-4-0,04
VD0R063-4-0,04
VD0R063-2-0,06
VD0R063-2-0,06
AD0R063-4-0,10
AD0R063-4-0,10
AD0R063-2-0,20
AD0R063-2-0,20
VD0R063-4-0,03
VD0R063-4-0,03
VD0R063-4-0,06
VD0R063-4-0,06
VD0R063-2-0,12
VD0R063-2-0,12
AD0R063-4-0,20
AD0R063-4-0,20
AD0R063-2-0,40
AD0R063-2-0,40
VD0R071-4-0,06
VD0R071-4-0,06
VD0R071-4-0,12
VD0R071-4-0,12
VD0R071-2-0,25
VD0R071-2-0,25
AD0R071-4-0,40
AD0R071-4-0,40
AD0R071-2-0,70
AD0R071-2-0,70
VD0R090-4-0,12
VD0R090-4-0,12
VD0R090-4-0,25
VD0R090-4-0,25
VD0R090-2-0,45
VD0R090-2-0,45
AD0R090-4-0,75
AD0R090-4-0,75
AD0R090-2-1,40
AD0R090-2-1,40
VD0R090-4-0,20
VD0R090-4-0,20
VD0R090-4-0,40
VD0R090-4-0,40
VD0R090-2-0,80
VD0R090-2-0,80
AD0R090-4-1,60
AD0R090-4-1,60
AD0R090-2-3,00
AD0R090-2-3,00
VD0R112-4-0,40
VD0R112-4-0,40
VD0R112-4-0,80
VD0R112-4-0,80
VD0R112-2-1,50
VD0R112-2-1,50
AD0R112-4-3,00
AD0R112-4-3,00
AD0R112-2-5,00
AD0R112-2-5,00

Speed
PN (kW)
0.02
0.02
0.04
0.04
0.06
0.06
0.10
0.10
0.20
0.20
0.03
0.03
0.06
0.06
0.12
0.12
0.20
0.20
0.40
0.40
0.06
0.06
0.12
0.12
0.25
0.25
0.40
0.40
0.70
0.70
0.12
0.12
0.25
0.25
0.45
0.45
0.75
0.75
1.40
1.40
0.20
0.20
0.40
0.40
0.80
0.80
1.60
1.60
3.00
3.00
0.40
0.40
0.80
0.80
1.50
1.50
3.00
3.00
5.00
5.00

Speed
rpm
1,400
1,400
1,400
1,400
2,800
2,800
1,400
1,400
2,800
2,800
1,400
1,400
1,400
1,400
2,800
2,800
1,400
1,400
2,800
2,800
1,400
1,400
1,400
1,400
2,800
2,800
1,400
1,400
2,800
2,800
1,400
1,400
1,400
1,400
2,800
2,800
1,400
1,400
2,800
2,800
1,400
1,400
1,400
1,400
2,800
2,800
1,400
1,400
2,800
2,800
1,400
1,400
1,400
1,400
2,800
2,800
1,400
1,400
2,800
2,800

Nominal
current1)
IN (A)
0.4
0.4
0.4
0.4
0.6
0.6
0.9
0.9
0.8
0.8
0.4
0.4
0.6
0.6
0.7
0.7
1.6
1.6
1.6
1.6
0.5
0.5
1.0
1.0
1.3
1.3
2.5
2.5
3.0
3.0
0.5
0.5
1.0
1.0
1.5
1.5
2.5
2.5
4.7
4.7
0.9
0.9
1.7
1.7
3.6
3.6
5.3
5.3
9.0
9.0
1.4
1.4
2.8
2.8
4.8
4.8
8.5
8.5
11
11

Current2)
approx. Imax.
(A)
0.4
0.4
0.4
0.5
0.6
0.6
1.1
1.2
1.2
1.3
0.5
0.5
0.6
0.6
0.9
1.0
1.9
2.0
2.3
2.6
0.6
0.6
1.1
1.2
1.7
1.9
2.8
3.2
4.5
5.0
0.8
0.9
1.7
1.8
3.5
3.8
5.4
5.9
8.5
10
1.6
1.7
3.6
3.9
6.0
7.0
9.0
10
16
17
2.7
2.9
5.0
5.5
8.5
9.5
19
22
30
33

Starting
current
IA (A)
1.0
1.0
1.0
1.0
1.9
1.9
2.4
2.4
4.4
4.4
1.0
1.0
1.6
1.6
3.0
3.0
4.6
4.6
9.0
9.0
2.0
2.0
3.0
3.0
4.5
4.5
8.5
8.5
16
16
2.8
2.8
5.2
5.2
9.0
9.0
16
16
38
38
5.2
5.2
9.3
9.3
18
18
38
38
58
58
10
10
22
22
40
40
60
60
120
120

cos
0.40
0.40
0.50
0.50
0.57
0.57
0.42
0.42
0.60
0.60
0.43
0.43
0.38
0.38
0.52
0.52
0.42
0.42
0.53
0.53
0.40
0.40
0.40
0.40
0.52
0.52
0.42
0.42
0.54
0.54
0.60
0.60
0.60
0.60
0.64
0.64
0.62
0.62
0.60
0.60
0.54
0.54
0.56
0.56
0.51
0.51
0.57
0.57
0.60
0.60
0.65
0.65
0.57
0.57
0.60
0.60
0.71
0.71
0.80
0.80

1) Current at average modulating torque (approx. 35 % of maximum torque)


2) Current at max. torque. We recommend to select switchgears according to these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
1/2

Issue

1.09
Y004.878/002/en

Electrical data Multi-turn actuators for modulating duty


with 3-phase AC motors
Intermittent duty S4 - 25 %, 400 V/50 Hz

SAR 07.2 SAR 16.2

Motor data are approximate. Due to usual manufacturing tolerances, there may be deviations from the values given.
The permissible fluctuation of the nominal voltage is 10 %. If the voltage drops below, there is a reduction of the nominal output
torque.
To protect against overheating, thermoswitches or PTC thermistors are embedded in the motor windings. For actuators
without integral controls (AUMA NORM), these have to be connected to the external control circuit (see terminal plan).
If thermoswitches or PTC thermistors are not connected, this voids our warranty for the motor.
Rating of the thermoswitches:
AC

DC

250 V, 50 60 Hz

cos = 1
cos = 0,6

60 V

1.0 A

2.5 A

42 V

1.2 A

1.6 A

24 V

1.5 A

For further details refer to Technical data Multi-turn actuators for modulating duty with 3-phase AC motors SAR 07.2 SAR
16.2.