Professional Documents
Culture Documents
DEWA Latest
DEWA Latest
Description
Approval certificates
Adapted to VDE 0295
Application
In dry and moist rooms for light mechanical stresses. Outdors only when
protected. Not in water. As supply or interconnecting cable for measuring,
controlling regulating and power supply. For control and power equipment
on conveyors and production lines and for regulating and monitoring work
processes in industrial plants and production lines. For flexible use with
light mechanical stress, free motion without periodic recurrence and
without forced guidance. Especial for the use in public areas and buildings
where special requirements regarding fire protection and security are
requested.
Design
Conductor
Copper bare stranded, Class 5 according to DIN VDE 0295:1995-06 or
IEC 60228
Insulation
Standards
International IEC60092-353;
IEC60332-3Cat.A;
IEC60754-1
National VDE(600/1000V);
VDE0295
Halogen
free
IEC
60754-1
+ brown
+ brown + green /yellow
+ brown + black + green /yellow
+ brown + black + grey + green /yellow
Mechanical
resistance to
impacts
Normal industrial
use
Cable
flexibility
Flexible
Smoke
density
IEC 61034
Flame
retardant
IEC 60332-3
Cat. A
Gases
corrosivity
No IEC
60754-2
Gases toxicity
No toxicity to IEC
60754-1
Dynamic operating
temperature, range
-5.0 .. 85.0C
Page 1 / 3
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Control Command Cables
Phone: +49-2166-27-2656
controlcables-sales.nd@nexans.com
Product List
Nexans
ref.
Nb. of
cores
Cross
section
(mm)
Copper
content
(kg/km)
78261202
78261205
2
5
1
1
78261206
78261403
78261404
78261405
IEC 60754-1
Flexible class 5
HFFR (Halogene Free Flame Retartant)
Black
XLPE (Cross-linked Polyethylene)
Bare copper
4000V
1.2kV
0.6/1 kV
Normal industrial use
Flexible
IEC 61034
IEC 60332-3 Cat. A
No IEC 60754-2
No toxicity to IEC 60754-1
-5.0 .. 85.0C
20(xD)
90C
10(xD)
-35.0 .. 85.0C
Yes
Yes
Yes
=Make to order,
With Green/
Yellow core
Approx.
weight
(kg/km)
19
48
Nom.
outer
diam.
(mm)
6.8
8.6
59
100
No
No
58
9.4
117
Yes
3
4
5
2.5
2.5
2.5
72
96
120
8.5
9.3
10.2
118
144
177
Yes
Yes
Yes
78261407
2.5
168
11.2
250
Yes
78261504
78261505
78261604
4
5
4
4
4
6
154
192
230
11.0
12.3
12.4
215
264
299
Yes
Yes
Yes
= Make to order,
=Make to stock
Core
identification
Colours
Colours
Black cores with
white numbers
Colours
Colours
Colours
Black cores with
white numbers
Colours
Colours
Colours
= Make to stock
Page 2 / 3
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Control Command Cables
Phone: +49-2166-27-2656
controlcables-sales.nd@nexans.com
78261605
78261704
78261804
78261805
78261854
78261855
78261904
78261905
78261951
78261955
78261070
78269070
78261957
78261120
78269120
78261958
78261150
78269150
78261240
78269240
78261300
78261400
Nb. of
cores
Cross
section
(mm)
Copper
content
(kg/km)
5
4
4
5
4
5
4
5
4
5
1
1
5
1
1
5
1
1
1
1
1
1
6
10
16
16
25
25
35
35
50
50
70
70
95
120
120
120
150
150
240
240
300
400
288
384
614
768
960
1200
1344
1680
1920
2400
672
672
4560
1152
1152
5760
1440
1440
2304
2304
2880
3840
Nom.
outer
diam.
(mm)
13.7
14.9
18.0
19.8
22.3
24.9
25.2
28.1
29.5
32.8
14.9
14.9
43.2
18.7
18.7
48.5
20.8
20.8
25.9
25.9
28.7
33.0
Approx.
weight
(kg/km)
With Green/
Yellow core
Core
identification
365
469
745
914
1132
1393
1510
1856
2160
2658
728
728
4968
1200
1200
6295
1497
1497
2394
2394
2993
4000
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
No
Yes
No
No
Colours
Colours
Colours
Colours
Colours
Colours
Colours
Colours
Colours
Colours
Black
Green / Yellow
Colours
Black
Green / Yellow
Colours
Black
Green / Yellow
Black
Green / Yellow
Black
Black
= Make to order,
= Make to stock
Page 3 / 3
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.