Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Telecom

Aerial

TELECOM AERIALAERO-DF03
Cable structure
1. 3(MDFNHW
2. 5LSFRUG
3. :DWHUEORFNLQJ\DUQV

Last mile
connection outdoor

Aerial

4. &HQWUDO/RRVHWXEH 3%7 
ZLWKwPFRORUHG
EHUVLQOOLQJJHO
5. )53VWUHQJWKPHPEHU

Telecom

Hi-crush

FTTH

TELECOM AERIAL Aero-DF03

Cable variants
Version

AERO-DF03

AERO-DF03

Fiber count





Cable dimensions [mm]

[ s

[ 

Cable weight [kg/km]





Max. installation tension[N]





Applications

QVWDOODWLRQRQSROHVRUZDOOV

&DQEHLQVWDOOHGLQSLSHOLQHV

Mechanical and enviromental characteristics

)XOO\GLHOHFWULFFDEOH

Parameter
Crush performance

5000 N

Bending performance

F\FOHV>['@

Water Penetration

PVDPSOHPKHDGK

Features

8SWREHUVLQDFDEOH

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRFDEOH

3(89UHVLVWDQW-DFNHW

Available colors
T-TELECOM (ACCORDING TO IEC 60304) - Fibers in tube
1-12

/RRVHWXEHZLWKOOLQJFRPSRXQG 3%7

10

11

12

Color

red

JUHHQ

EOXH

ZKLWH

violet

RUDQJH

JUH\

\HOORZ

EURZQ

SLQN

EODFN

DTXD

13-24

13

14

15

16

17

18

19

20

21

22

23

24

7ZR)53VWUHQJWKHOHPHQWV

5LSFRUG\DUQV)RUHDV\MDFNHWUHPRYDO

Code

Operating temperature
+100

Code
ZKLWH

violet

RUDQJH

JUH\

\HOORZ

EURZQ

SLQN

QDWXUDO

QEHUWXEHFRQVWUXFWLRQFRORUVZLOOEHUHSHDWHGWRIDFLOOLWDWHLGHQWLFDWLRQEHUVZLOOKDYHULQJVHYHU\FP
NESC Light

DTXD

-15C

span: 120 m

-40C

sag: 2.4 m

NSC Medium
span: 70 m

sag: 1.4 m

NESC Heavy
span: 40 m

sag: 0.8 m

 | TELECOM AERIAL AERO-DF03

-100

TRANSPORT

EOXH

OPERATION

JUHHQ

INSTALLATION

red

temperature [C]

Color

+70C
+55C

TELECOM AERIALAERO-AS02 2.0 MM

TELECOM AERIAL Aero-AS02 2.0 mm


1

Cable structure

Aerial

Telecom

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

FTTH

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS02 PBT TUBES 2.0 MM


Version

1-6T x 6F

Fibers


1-6T x 12F 

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]







Applications

Tensile load [N]


Crush
allowed

static

















8T x 12F













12T x 12F

















[N/10 cm]



2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG

'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV

Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)


NESC Light
span: 130 m

sag: 2.6 m

NSC Medium
span: 85 m

sag: 1.7 m

NESC Heavy
span: 45 m

sag: 0.9 m

TELECOM AERIAL AERO-AS02 2.0 MM | 

TELECOM AERIALAERO-AS03 2.0 MM

TELECOM AERIAL Aero-AS03 2.0 mm


1

Cable structure

Aerial

Telecom

FTTH

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS02 PBT TUBES 2.0 MM


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Tensile load [N]


Crush
allowed

static

1-6T x 6F













1-6T x 12F















8T x 12F













12T x 12F

















[N/10 cm]

Applications



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG
Available colors
Features

T-TELECOM (ACCORDING TO IEC 60304) - Fibers


1-12

10

11

12

red

JUHHQ

EOXH

ZKLWH

violet

RUDQJH

JUH\

\HOORZ

EURZQ

SLQN

EODFN

DTXD

T-TELECOM (ACCORDING TO IEC 60304) - Tubes


Tube

10

11

12

Code
Color

red

JUHHQ

EOXH

ZKLWH

violet

RUDQJH

JUH\

\HOORZ

EURZQ

SLQN

EODFN

DTXD

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW
'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

Code
Color

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

QFDVHRIORZHUEHUFRXQWVRPHWXEHVFDQEHUHSODFHGE\OOHUV

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70C

-15C

NSC Medium
span: 130 m

sag: 2.6 m

NESC Heavy
span: 75 m

sag: 1.5 m

 | TELECOM AERIAL AERO-AS03 2.0 MM

-40C

-100

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 3.8 m

temperature [C]

span: 190 m

TELECOM AERIALAERO-AS03 2.5 MM

TELECOM AERIAL Aero-AS03 2.5 mm


1

Cable structure

Aerial

Telecom

FTTH

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS03 PBT TUBES 2.5 MM


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F













1-6T x 12F















8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG

Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70C

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 3.8 m

temperature [C]

span: 190 m

-15C

NSC Medium
span: 140 m

-40C

-100
sag: 2.8 m

NESC Heavy
span: 80 m

sag: 1.6 m

TELECOM AERIAL AERO-AS03 2.5 MM | 

TELECOM AERIALAERO-AS04 2.0 MM

TELECOM AERIAL Aero-AS04 2.0 mm


1

Cable structure

Aerial

Telecom

FTTH

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS04 PBT TUBES 2.0 MM


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1T x 12F













2T x 6F











2T x 12F













4T x 6F











3T x 12F













6T x 6F











4T x 12F













8T x 6F











6T x 12F













8T x 12F













12T x 12F

















2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG

Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV

Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NSC Light

+70C

-15C

NSC Medium
span: 170 m

-40C

-100
sag: 3.4 m

NSC Heavy
span: 95 m

sag: 1.9 m

 | TELECOM AERIAL AERO-AS04 2.0 MM

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 5.0 m

temperature [C]

span: 250 m

TELECOM AERIALAERO-AS04 2.5 MM

TELECOM AERIAL Aero-AS04 2.5 mm


1

Cable structure

Aerial

Telecom

FTTH

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS04 PBT TUBES 2.5 MM


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F













1-6T x 12F









99





8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG

Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70C

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 5.2 m

temperature [C]

span: 260 m

-15C

NSC Medium
span: 190 m

-40C

-100
sag: 3.8 m

NESC Heavy
span: 110 m

sag: 2.2 m

TELECOM AERIAL AERO-AS04 2.5 MM | 

TELECOM AERIALAERO-AS06 2.0 MM

TELECOM AERIAL Aero-AS06 2.0 mm


1

Cable structure

Aerial

Telecom

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

FTTH

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS06 PBT TUBES 2.0 MM


Qnt
Version
Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F













1-6T x 12F















8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]

'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV



Features

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70C

-15C

NSC Medium
span: 250 m

-40C

-100
sag: 5.0 m

NESC Heavy
span: 140 m

sag: 2.8 m

 | TELECOM AERIAL AERO-AS06 2.0 MM

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 7.2 m

temperature [C]

span: 360 m

TELECOM AERIALAERO-AS06 2.5 MM

TELECOM AERIAL Aero-AS06 2.5 mm


1

Cable structure

Aerial

Telecom

FTTH

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS06 PBT TUBES 2.5 MM


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F













1-6T x 12F















8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG

Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

'U\\DUQVWRSUHYHQWPRLVWXUHLQWRWKHFDEOH

HOHPHQWV6=VWUDQGHGFDEOHFRUH

)LOOHUV LIDSSOLFDEOH

$UDPLG\DUQVDVVWUDLQUHOLHIDQGZDWHUDEVRUEHQW

/RRVHWXEH 3%7PP ZLWKOLQJFRPSRXQG


2SWLFDOEHUV
:DWHUVZHOODEOHWDSH
89VWDELOL]HG+'3(MDFNHW

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70C

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 7.4 m

temperature [C]

span: 370 m

-15C

NSC Medium
span: 270 m

-40C

-100
sag: 5.4 m

NESC Heavy
span: 150 m

sag: 3.0 m

TELECOM AERIAL AERO-AS06 2.5 MM | 

TELECOM AERIALAERO-AS09 2.5 MM

TELECOM AERIAL Aero-AS09 2.5 mm


1

Cable structure

Aerial

Telecom

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

FTTH

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS09 PBT TUBES 2.5 MM


Qnt
Version
Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F













1-6T x 12F















8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV
89UHVLVWDQW

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG
Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQWPP

2SWLFDOEHUV

HOHPHQWV6=VWUDQGHGFDEOHFRUH

/RRVHWXEHZLWKOOLQJFRPSRXQG 3%7PP
'U\\DUQVWRSUHYHQWPRLVWXUHLQWRFDEOH
$UDPLG\DUQVDVWHQVLOHHOHPHQWV

Operating temperature
+100
+70C

sag: 10.6 m

-15C
-40C

NSC Medium
span: 400 m

-100

sag: 8.0 m

NESC Heavy
span: 230 m

sag: 4.6 m

 | TELECOM AERIAL AERO-AS09 2.5 MM

TRANSPORT

OPERATION

span: 530 m

+55C
INSTALLATION

NESC Light

temperature [C]

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

TELECOM AERIALAERO-AS12 2.5 MM

TELECOM AERIAL Aero-AS12 2.5 mm


1

Cable structure

Aerial

Telecom

FTTH

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS12 PBT TUBES 2.5 MM


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F











9000

1-6T x 12F















8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV
89UHVLVWDQW

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG
Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

2SWLFDOEHUV

HOHPHQWV6=VWUDQGHGFDEOHFRUH

/RRVHWXEHZLWKOOLQJFRPSRXQG 3%7PP
'U\\DUQVWRSUHYHQWPRLVWXUHLQWRFDEOH
$UDPLG\DUQVDVWHQVLOHHOHPHQWV

Operating temperature
+100
+70C

sag: 14 m

TRANSPORT

OPERATION

span: 700 m

+55C
INSTALLATION

NESC Light

temperature [C]

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

-15C
-40C

NSC Medium
span: 530 m

-100

sag: 10.6 m

NESC Heavy
span: 310 m

sag: 6.2 m

TELECOM AERIAL AERO-AS12 2.5 MM | 

TELECOM AERIALAERO-AS14 2.5 MM

TELECOM AERIAL Aero-AS14 2.5 mm


1

Cable structure

Aerial

Telecom

1. +'3(RXWHUMDFNHW
2. $UDPLG\DUQV
3. &HQWUDOVWUHQJWK
PHPEHU )53
4. /RRVHWXEHV 3%7 
ZLWKFRORUHGEHUVLQ
OOLQJJHO
5. :DWHUEORFNLQJ\DUQV

FTTH

6. Fillers
7. :DWHUEORFNLQJWDSH
8. 5LSFRUG

3
4
7

5
8

&RQJXUDWLRQ

AERO-AS14 PBT TUBES 2.5 MM


Qnt
Version
Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1-6T x 6F













1-6T x 12F















8T x 12F













12T x 12F

















Applications
Crush
[N/10 cm]



'XFW SROHPRXQW
+LJKWHQVLOHDQGFUXVKSHUIRUPDQFH
)XOO\GLHOHFWULFFDEOH
6HOIVXSSRUWHGDHULDOFDEOHZLWKDUDPLGUHLQ
IRUFHPHQWV
89UHVLVWDQW

2WKHUEHUFRXQWVDYDLODEOHRQGHPDQG
Features

)53VWUHQJWKDQGDQWLEXFNOLQJHOHPHQW

2SWLFDOEHUV

HOHPHQWV6=VWUDQGHGFDEOHFRUH

/RRVHWXEHZLWKOOLQJFRPSRXQG 3%7PP
'U\\DUQVWRSUHYHQWPRLVWXUHLQWRFDEOH
$UDPLG\DUQVDVWHQVLOHHOHPHQWV

Operating temperature
+100
+70C

sag: 16.0 m

-15C
-40C

NSC Medium
span: 600 m

-100

sag: 12.0 m

NESC Heavy
span: 350 m

sag: 7.0 m

 | TELECOM AERIAL AERO-AS14 2.5 MM

TRANSPORT

OPERATION

span: 800 m

+55C
INSTALLATION

NESC Light

temperature [C]

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)