Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 8

XIV.

SPECIFICATIONS
1. ELECTRIC GENERATOR
Total output = 28,000 kW

2. STEAM TURBINE
Type: Multi-stage Impulse Turbine
Mean Wheel Diameter

= 125 cm

Angular Speed

= 3600 rpm

Nozzle Angle

= 15

Indicated Turbine Power

= 33492.823 kW

Number of Stage

= 2 Velocity and 4 Pressure Stages

Shaft Diameter

= 19.9846 inch

3. CONDENSER
Type: Surface Type Condenser
Number of Passes

= 2 pass

Number of tubes

= 1848 Tubes

Type of Tube: No. 18 BWG Admiralty Metal


Outside Diameter

= 2.22 cm

Inside Diameter

= 1.97 cm

Length of Tube

= 11.069 m

Shell Diameter

= 2.011 m

Thickness

= 0.125 cm

Page | 444

4. EVAPORATOR
Type: Single Effect, Submerge Type
Number of Tubes

= 39 tubes

Inside Diameter

= 0.0222 mm

Length of Tube

= 3.92 m

Shell Diameter

= 3.0342 m

5. STEAM BOILER
a. SUPERHEATER
Number of Element

= 178

Length of Element

= 67.43 m/element

Tube Diameter: 20.07 mm ID and 25.4 mm OD


b. ECONOMIZER
Tube Diameter= 77.92 mm ID and 88.90 mm OD
Number of Passes

= 11

Length of Element

= 21.44 m/element

Length per Pass

= 1.9613 m

Tube Spacing

= 128 mm

c. AIR HEATER
Type: Tubular type
Pipe Diameter : 52.5 mm ID and 60.3 mm OD, steel pipe
d. FURNACE
Type: Water-Walls Furnace
Length = 5 m
Width = 4 m
Height = 16.4614 m
Number of Tubes = 120 tubes
Page | 445

Tube Diameter: 88.9 mm ID


Spacing on Centers

= 152.4 mm

e. RISERS
Number of Tubes

= 541 tubes

Diameter of Tubes

= 50.8 mm

Length of Tubes

=6m

f. DOWN COMERS
Number of Tubes

= 50

Diameter of Tubes

= 1.71 in ID and 2 in OD

Length of Tubes

= 7.0 m

g. UPPER STEAM DRUM/HEADER


Diameter = 2 m
Length = 5 m

h. LOWER STEAM DRUM/HEADER


Diameter = 1 m
Length = 5 m
6. HEATERS
Type: Surface/Close Type Heater
a. HEATER No. 1
Number of Tubes

= 498

Tube Diameter

= 0.0222 m

Number of Passes

= 2 pass

Length of Tube

= 1.8 m

Shell Diameter

= 0.737 m

Page | 446

b. HEATER No. 2
Number of Tubes

= 631 tubes

Tube Diameter

= 0.0222 m

Number of Passes

=2

Length of Tube

= 1.8 m

Shell Diameter

= 0.83 m

c. HEATER No. 3
Number of Tubes

= 557 tubes

Tube Diameter = 0.0222 m


Number of Passes

=2

Length of Tube

= 1.8 m

Shell Diameter

= 0.781 m

d. HEATER No. 4
Number of Tubes

= 533 tubes

Tube Diameter

= 0.0222 m

Number of Passes

=2

Length of Tube

= 1.8 m

Shell Diameter

= 0.764 m

e. HEATER No. 5
Number of Tubes

= 518 tubes

Tube Diameter

= 0.0222 m

Number of Passes

=2

Length of Tube

= 1.8 m
Page | 447

Shell Diameter

= 0.752 m

f. HEATER No. 6
Number of Tubes

= 569 tubes

Tube Diameter

= 0.0222 m

Number of Passes

=2

Length of Tube

= 1.8 m

Shell Diameter

= 0.789 m

g. HEATER No. 7
Number of Tubes

= 564 tubes

Tube Diameter

= 0.0222 m

Number of Passes

=2

Length of Tube

= 1.8 m

Shell Diameter

= 0.785 m

h. HEATER No. 8
Number of Tubes

= 660 tubes

Tube Diameter

= 0.0222 m

Number of Passes

=2

Length of Tube

= 1.8 m

Shell Diameter

= 0.837 m

7. PIPE: DIAMETERS
Page | 448

Type: Schedule 40, Seamless Steel Pipe


a.STEAM PIPES
Superheater to Turbine Inlet

= 10.749 in.

Turbine extraction outlet to Separation point of Steam = 6.626 in.


Separation point to Heater No. 1

= 5.563 in

Separation point to evaporator

= 4.5 in.

Turbine Extraction Outlet 2 to Heater No. 2

= 6.626 in.

Turbine Extraction Outlet 3 to Heater No. 3

= 6.626 in.

Turbine Extraction Outlet 4 to Heater No. 4

= 6.626 in

Turbine Extraction Outlet 5 to Heater No. 5

= 8.626 in.

Turbine Extraction Outlet 6 to Heater No. 6

= 10.748 in

Turbine Extraction Outlet 7 to Heater No. 7

= 12.75 in.

Turbine Extraction Outlet 7 to Heater No. 8

= 12.75 in.

Turbine to Condenser

= 12.75 in.

Evaporator to Condenser

= 4.5 in.

b.FEED WATER PIPE


Hot well to Heater 8 = 6.626 in.
Heater 8 to Heater 7 = 8.626 in.
Heater 7 to Heater 6 = 8.626 in.
Heater 6 to Heater 5 = 8.626 in.
Heater 5 to Heater 4 = 8.626 in.
Heater 4 to Heater 3 = 8.626 in.
Heater 3 to Heater 2 = 8.626 in.
Heater 2 to Heater 1 = 8.626 in.
Heater 1 to Boiler Economizer = 8.626 in.

c. CONDENSATE PIPE
Page | 449

Pipeline of Condensate Water:


From Heater 1 to Heater 2 = 1.9
From Heater 2 to Heater 3 = 2.37 in.
From Heater 3 to Heater 4 = 2.87 in.
From Heater 4 to Heater 5 = 3.5 in.
From Heater 5 to Heater 6 = 3.5 in.
From Heater 6 to Heater 7 = 3.5 in.
From Heater 7 to Heater 8 = 4.5 in.
From Heater 8 to Hot well = 4.5 in.

d. MAKE-UP WATER PIPE


Evaporator Make-up water Pipe = 1.05 in.

e. BLOW-DOWN PIPE
Evaporator Blow-Down Pipe = 0.84 in.
Boiler Blow-Down Pipe

= 1.05 in.

8. COOLING TOWER
Type: Induced Draft Cooling Tower
Height = 50 ft
Length = 57.942 ft
Width = 57.942 ft
Fan Power

= 701.6 hp x 2 units

Fan Stack Diameter

= 5m

No. Of rows

= 15 rows

9. CHIMNEY
Page | 450

Height = 21.36 m
Top Inside Diameter = 3.3 m
Top Outside Diameter = 3.71 m
Base Inside Diameter = 3.938 m
Base Outside Diameter = 4.332 m
10. PUMPS
1. Feed Water Pump
= 53 hp
2. Condenser Cooling Water Pump
= 4.4 hp
3. Fuel Pump
= 0.342 hp
4. Induced draft fan capacity
= 701.6 hp

11. FUEL SYSTEM


a. DAY TANK
Diameter

= 6.62 m

Height

= 6.62 m

b. STORAGE TANK
Number of Storage = 5
Diameter

= 12.03 m

Height

= 12.03 m

12. DIESEL GENERATOR SET


Capacity = 760 kW = 1019 hp
13. EXPANSION VALVE
Page | 451