Aerodr X70 FR PDF
Aerodr X70 FR PDF
Aerodr X70 FR PDF
X-ray tube
AeroDR detector
CS-7 console
Generator
Accessories
Patient handgrip for table
Lateral detector /
Others
Grid 40 lp/cm 8:1 100cm
Grid 40 lp/cm 10:1 115cm
Grid 40 lp/cm 10:1 150cm
Grid 40 lp/cm 10:1 180cm
Grid 40 lp/cm 12:1 200cm
Distributed by
21111101EU
W A L L S T A N D B U C K Y
High patient throughput
590mm
Non-tilt:1780mm
(tilt:1710mm)
Non-tilt:
1470mm*
(tilt:1400mm)
X-ray Room
310mm
Non-tilt : 40
0mm
2170mm
( tilt : 750 m
m)
-20
AeroDR
X-ray
Photodiode
photodiode
Top Position
Cross-sectional electron
microscope photograph
of a CsI scintillator
90
Center Position
Landscape
Examination
of extremities
The removable grid and tilting
bucky allow the flat panel detector to easily be used for examinations of extremities or less
mobile patients.
T A B L E B U C K Y
Accommodates patients of all body types
The maximum weight capacity of the table is 295kg and will accommodate
a wide variety of patients. The floating table top enables a default coverage
of 200 cm without having to move the patient. This flexible table ensures
easy positioning and is suitable for all body types.
The table bucky has a built in foot controller and can be equipped with an
extra hand controller* as well as an additional foot controller* to provide an
* Optional
optimal working environment.
5
00m
m
m
50m
1
m
50m
1
* Optional
* Optional
5
00m
m
* Standard
295
kg
Table top
540 to 850 mm
300mm
2400 800
Synchronised movement of the tube and detector is standard. The X-ray tube automatically
tracks the detector during wall stand or table bucky adjustments, also when the tube is placed
in an angled position.
mm
Manual operation
Auto-Tracking
CONSOLE CS-7
Detector
nd
ta
l s ky
al c
W bu
y
ra
X-
S
IU
G
E 0
R 21
le
b
Ta
roo
m
ky
uc
b
You can check the remaining battery level, radio field intensity and panel location through the
panel auto tracing function at a glance on the CS-7 screen in real time.
Scintillator
Pixel size
175m
Image field
Dimensions ( W x D x H)
Dynamic range
4 digits
e
ol
ns
co
-7
x-r
ay
e
b
tu
b
su
S
C
Our CS-7 work station doesn t just control the AeroDR system. It also controls the
generator, the collimator and even all current Konica Minolta CR readers. There is no
need to use the X-ray console to adjust exposure conditions. When the sub console is
installed in the X-ray room, the acquired image can immediately be confirmed.
S
IU
G
E 0
R 11
deAero
tec DR
tor
X-ray System
Generator
Output
50 kW
65 kW
80 kW
Frequency(up to)
240 kHz
240 kHz
240 kHz
Exposure voltage
40 to 150 kVp
mA range
Standard
Input rating
Standard
X-Ray Tube
Varian
Focal spot
0.6 /1.2 mm
kHU
32 / 77 kW
40 /100 kW
40 /100 kW
Anode angle
12
12
12
10000 rpm
10000 rpm
10000 rpm
Ceiling suspension
Standard
Weight
Vertical stroke
1450 mm or 1700 mm
Tube rotation
2500 mm
Height movement
Motorized
Tracking
Patient load
Attenuation equivalent
0.7 mm AL eq.
2400800 mm
300 mm
AEC
Attenuation equivalent
0.6 mm Al eq,
AEC
Grid
Manually exchangeable
Positions detector
90- -20
Attenuation equivalent
0.6 mm Al eq,
AEC
Grid
Manually exchangeable
Options
Collimator
Auto collimator ( APR based ) , Integrated DAP chamber
Integrated Automated filter ( APR based ) , Laser light
Installation cube
3 m 4 m,150 kg ( including transfers)