Technical Specification Nr:

Date: 02.07.2010

10418
Page 1 (5)

HFO/LFO Feeder Unit for Compact Booster


Technical Specification
Type:
Serial Nr:
Manufacturer:
Site:
Customer:

Feeder AMF-F-180-HFO/LFO (Frequency controlled)


10418
Auramarine Ltd
KPC Unit II
Wrtsil Finland Oy, Power Plants

1. Design Basis
Engine type :
Total power max.:
HFO viscosity max.:
HFO day tank temp min.:
LFO viscosity min.:
Main voltage:
Control voltage:
Trace heating media:
Fuel consumption max.:
Fuel operating / test pressure:
Pressurized air:

7 x W18V46
7 x 17550 kW
380 cSt / 50 C
90 C
2.8 cSt at pump inlet
415 V / 50 Hz
110 VAC
Steam
7 x 3.5 t/h
6 / 9 bar
5-7 bar

2. Technical data
HFO pump capacity
Suction pressure
Electric motor

30 m3/h, 6 bar, 75 cSt, fixed speed


0 bar(g)
15 kW, 4-pole, IEC, F, B5, IP 55
El. Motor equipped with extra fan

LFO pump capacity


Suction pressure
Electric motor

34 m3/h, 6 bar, 7 cSt, fixed speed


0 bar(g)
11 kW, 2-pole, IEC, F, B5, IP 55
El. Motor equipped with extra fan

Certificate

EC Declaration of Conformity

AURAMARINE LTD
Street address:
Keskilntie 1
FIN-20660 LITTOINEN
FINLAND
Internet: www.auramarine.fi

Postal address:
P.O.BOX 849
FIN-20101 TURKU
FINLAND

Tel + 358 204 86 5030


Fax + 358 204 86 5031

Reg. office:
Business ID:
ALV rek/ VAT reg:

Lieto
0684696-3
FI06846963

Technical Specification Nr:


Date: 02.07.2010

10418
Page 2 (5)

3. Main Components
Pos.

Denomination

V015, V017.

Emergency shut off valve


VALPRES
- Electro-pneumatic operation with spring return (N.C.)

B001, B002, B003.

Suction strainer
- Y-type
- Filtration 400 microns nominal

D001, D002.

HFO Feeder pump


IMO ACF 080N5 NVBP
- Rotary self- priming displacement screw pump
- One is stand-by pump while the other is working
- Pump is driven by frequency converter and controlled via PLC
- Electric motor (Pos. M001, M002)

B016.

HFO Viscosity measurement system


- Vibration type viscometer
- 4-20 mA signal from viscometer, corresponding to 0-100 cSt

V011.

HFO Underpressure regulating valve


KRACHT SPVF 25
- Pressure regulating overflow valve
- Setting range 2-5 bar, set point 4 bar

V012A, V012B.

HFO Overpressure regulating valve


KRACHT SPVF 80
- Pressure regulating overflow valve
- Setting range 4-12 bar, set point 8 bar

AURAMARINE LTD
Street address:
Keskilntie 1
FIN-20660 LITTOINEN
FINLAND
Internet: www.auramarine.fi

Postal address:
P.O.BOX 849
FIN-20101 TURKU
FINLAND

Tel + 358 204 86 5030


Fax + 358 204 86 5031

Reg. office:
Business ID:
ALV rek/ VAT reg:

Lieto
0684696-3
FI06846963

Technical Specification Nr:


Date: 02.07.2010

10418
Page 3 (5)

B014.

HFO Automatic filter


BOLL & KIRCH 6.61 DN 150
- Self cleaning automatic filter
- 34 microns absolute

B039.

Sludge tank, 50 l

D012.

Pneumatic sludge pump


DEPA DL 15

B015.

HFO By-pass filter


BOLL& KIRCH 1.03.2 DN150
- Simplex manual filter
- 34 microns absolute

D006.

LFO Feeder pump


IMO ACG070K7 NVBP
- Rotary self- priming displacement screw pump
- Pump is driven by frequency converter and controlled via PLC
- Electric motor (Pos. M006)

V013.

LFO Underpressure regulating valve


KRACHT SPVF 25
- Pressure regulating overflow valve
- Setting range 2-5 bar, set point 4 bar

V014A, V14B.

LFO Overpressure regulating valve


KRACHT SPVF 80
- Pressure regulating overflow valve
- Setting range 4-12 bar, set point 8 bar

AURAMARINE LTD
Street address:
Keskilntie 1
FIN-20660 LITTOINEN
FINLAND
Internet: www.auramarine.fi

Postal address:
P.O.BOX 849
FIN-20101 TURKU
FINLAND

Tel + 358 204 86 5030


Fax + 358 204 86 5031

Reg. office:
Business ID:
ALV rek/ VAT reg:

Lieto
0684696-3
FI06846963

Technical Specification Nr:


Date: 02.07.2010

10418
Page 4 (5)

4. Control Automation and Starters


Equipment:

NOTE:
Feeder pumps are driven by external frequency converters.
Frequency converters or stand-by automatic of feeder pumps are
not included in Auramarines scope of supply.
Signal from local pressure transmitter 0-10 bar = 4-20 mA for
external stand-by automatic is included.

Local Control Cabinet:


- Main switch (0/1) and transformer for supply voltage
- Switches (0/1) for quick closing valves manual operation
- Switches (0/Auto) for fans of feeder pumps el. motors
- Starters for fans of feeder pumps el. motors
- Switches (Run/Stop/Auto) for feeder pumps el. motors
- Switch (1/2) for HFO pump master / stand-by selection
- Indication light (Running) for each feeder pump
- Indication lights (High pressure HFO and LFO)
- Automatic filter control
- Switch (0/1) for viscometer(s)
- Terminal block for instrumentation cables
- Local alarm panel with one common alarm to ECR
Alarm lights at alarm panel:
- Fan of electric motor M001 tripped
- Fan of electric motor M002 tripped
- Fan of electric motor M006 tripped
- Automatic filter B014 clogged
- By-pass filter B015 clogged
- Emergency shut off valve V015 closed
- Emergency shut off valve V017 closed
- Control voltage failure (Signal only)
Safety switches for electric motors.

AURAMARINE LTD
Street address:
Keskilntie 1
FIN-20660 LITTOINEN
FINLAND
Internet: www.auramarine.fi

Postal address:
P.O.BOX 849
FIN-20101 TURKU
FINLAND

Tel + 358 204 86 5030


Fax + 358 204 86 5031

Reg. office:
Business ID:
ALV rek/ VAT reg:

Lieto
0684696-3
FI06846963

Technical Specification Nr:


Date: 02.07.2010

10418
Page 5 (5)

5. Instruments
Pos.

Denomination

PI
PT
PDIS
TT
GS

- Manometers before pumps, filter and at outlet lines (Scale in bar)


- Pressure transmitter 0-10 bar (4-20 mA) for external stand by
- Differential pressure indication switches for filters.
- Temperature transmitter 0-200C (4-20 mA)
- Limit switches for quick closing valves at LFO and HFO inlets
Feeder pumps to be interlocked with these limit switches

6. Materials, miscellaneous
Frame

- Welded of profile steel bars


- Equipped with a bottom for leakage oil
- Painting system ISO 12944-5:2007 A2.06 (EP 120/2 FeSa 2)
- Color RAL 5019

Cabinet

- Color RAL 7035

Oil pipes

- Seamless carbon steel St 35.8 DIN 2448


- Welding according to ISO 3834-2:2005
- Trace heating in two circuits. One for sludge line and other for
HFO piping.
- Insulated with mineral wool, covered by galvanized steel sheet

Flanges

- DIN 2576 or 2633

Instrument pipes

- Hydraulic pipe St 35.4 DIN 2445.2.2

AURAMARINE LTD
Street address:
Keskilntie 1
FIN-20660 LITTOINEN
FINLAND
Internet: www.auramarine.fi

Postal address:
P.O.BOX 849
FIN-20101 TURKU
FINLAND

Tel + 358 204 86 5030


Fax + 358 204 86 5031

Reg. office:
Business ID:
ALV rek/ VAT reg:

Lieto
0684696-3
FI06846963

You might also like